Important Safeguards

Use this appliance only as described in this instruction manual.

As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner.

This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in accordance with the relevant national legislation.

Should repairs be necessary, contact the nearest authorized Repair Service Center. Unauthorized servicing can be dangerous.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

In the case that the power cord becomes damaged, this must be repaired only by specialized personnel authorized by the manufacturer in order to protect against fire.

Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts check with a qualified electrician.

We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-prong grounded extension cord, attachment plug and connector, rated 15A, 125V

Before cleaning or maintenance operations, always unplug the unit from the outlet.

Do not pull on or place strain on the power cord when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.

Do not rest hot or heavy objects on the appliance.

Clean the filters at least once a week.

Avoid using heaters near the unit.

The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.

Beforetransportingtheunit,draintheunit.Aftertransportation,waitatleast6hoursbeforeswitchingtheuniton.

The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection.

This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

ENVIRONMENTAL INFORMATION: This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol. Avoid perforating the refrigerant circuit of the appliance.

Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975).

SAVE THESE INSTRUCTIONS

THIS PRODUCT IS FOR HOUSEHOLD ONLY

DESCRIPTION

10

power cable

1

air outlet grille

11

wall flange

2

control panel

12

air exhaust hose

3

remote control receiver

13

window outlet

4

castor wheels

14

castor locks

5

handles

15

remote control

6

filter

16

window bracket with locking pins

7

air intake grille

17

end of season dust cover

8

air exhaust hose housing

18

end of season accessories bag

9

drainage hose

19

extra locking pins for window bracket

4

Setting up your portable air-conditioner

TO AVOID DAMAGE TO THE UNIT:

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED.

(After the unit has been on its side, oil needs to return to the compressor to ensure proper function. Without allowing the unit this time (6-24 hours) The unit may function for only a short time, and then the compressor will break down from lack of oil).

ELECTRICAL CONNECTIONS

Before plugging the appliance into the outlet, check that:

The outlet’s power supply corresponds to the value indicated on the rating label on the back of the appliance;

The outlet and electrical circuit are adequate for the appliance;

The outlet is a 3-hole grounded outlet. If this is not the case, you must choose another outlet.

Failure to follow these important safety instructions absolves the manufacturer of all liability.

If it becomes necessary, the power cable must be replaced by a qualified professional only.

The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible.

Before use, make sure the air intake and outlet grilles are unobstructed.

AIR CONDITIONING WITHOUT INSTALLATION

NOTE: Keep the air hoses as short and free of curves as possible to avoid constrictions.

FOR OPTIMAL RESULTS SET-UP IN A DOUBLEHUNG WINDOW:

1)Place the bracket in the window sill, extend the bracket fully within the window frame, fix the bracket by using the pin then lower the window onto the bracket. (Should the window bracket be too large for the window. The plastic can be cut with a saw by a qualified professional.)

2)Fit the air exhaust hose in the housing at the back of the appliance. Insert it as shown in figure A.

3) Connect the window outlet 13 to the other end of the exhaust hose.

Other set-up methods:

Thanks to the locking pins, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket so to allow a correct installation of the exhaust hose (see figure C)

C

If you have a casement window (figure D) follow steps 2 & 3 and place the window outlet

13 outside the window to exhaust the hot air.

A

4)window outlet end of the exhaust

slot of the window bracket (fig. B).

B

D

For help with installation, operation, and for all accessories and spare/replacement parts, Please contact our toll free customer service call center at:

1-800-322-3848 [US only]

Monday – Friday 8:30am – 5:00pm ET Or log onto our website at www.delonghiusa.com.

5

DeLonghi PAC-A130HPE User Manual

Semi-permanent installation

SEMI-PERMANENT INSTALLATION

If required, your appliance can also be installed semi-permanently (Fig. E).

 

11,8 in

 

30 cm

11,8 in

E

30 cm

 

Proceed as follows:

Drill a hole ø 5,25 inches (ø 134 mm) in an outside wall or through a window pane. Respect the dimensions and height of the hole given in figure F and G.

134 5,27 in.

in the win-

in the wooden

in the wall: it is

recommended

dow pane

kickboard of

that you insulate

 

 

a French win-

F

 

dow

a section of the

 

wall using suit-

 

 

 

 

 

 

able insulation.

Fit the wall flange

11

 

into the hole.

 

 

 

 

 

 

 

 

 

 

 

Fit the air exhaust hose

 

12

into the air

 

 

 

 

 

 

 

 

 

 

 

 

exhaust hose housing

8

 

located on the

 

rear side of the appliance (fig. A page 5).

 

 

 

 

 

 

 

to the wall

Fit the end of the hose

 

12

 

 

 

 

 

 

 

 

 

 

 

 

flange

11

as shown in fig. G.

G

MAX100 cm

MAX 39,37 inches

MIN 35 cm

MIN 13,77 inches

When the hose 12 is not connected, the

drilled hole can be closed with the flange cap 11 .

NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open as little as 1/2 “ (1 cm) to guarantee correct ventilation and room pressure.

Keep the exhaust hose as short and free of curves as possible to avoid constrictions.

“As special tools are required for installation, we suggest you have the appliance installed by specialized personnel.”

6

Control panel

THE CONTROL PANEL

1 3 5

2 4 6

13

14

15

8 9

7

11

10 12

DESCRIPTION OF THE CONTROL PANEL

1Air conditioning symbol

2Dehumidifying symbol

3Fan symbol

4Heating symbol

5SMART symbol

6BOOST symbol

7Temperature indicator

8Timer symbol

9Alert symbol

10AUTOFAN indicator

11Fan speed indicator

12SLEEP symbol

13MODE button (selects the modes)

14BOOST button

15FAN button

16ON/Standby button

17Increase (+) and decrease (-) temperature button

16

17

OPERATING FROM THE CONTROL PANEL

The control panel enables you to manage all the main functions of the appliance, but some features are present only on the remote control.

TURNING THE APPLIANCE ON

Plug into an outlet. Two lines appear on the display indicating that the appliance is in standby mode.

Press the (16) button until the appliance comes on. The last function active when it was turned off will appear.

Never turn the air conditioner off by unplugging from the outlet. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.

7

Operation

AIR CONDITIONING MODE

Ideal for hot muggy weather when you need to cool and dehumidify the room.

To set this mode:

Press the MODE button a number of times until the air-conditio- ning symbol appears.

Select the target temperature by pressing the or button until the desired temperature is reached.

Select the desired fan speed by pressing the FAN button. Four speeds are available:

Maximum speed: to achieve the target temperature as rapidly as possible

Medium speed: reduces noise levels while maintaining a comfortable temperature

Low speed: for silent operation and maxium energy efficiency

AUTO: the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display.

The most suitable temperature for the room during the summer varies from 75°F to 81°F (24 to 27°C). You are recommended, however, not to set a temperature much below the outdoor temperature.

DEHUMIDIFYING MODE

Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc).

In dehumidifying mode, the appliance MUST be set-up in the same way as for air conditioning, with the air exhaust hose attached to enable the moisture to be discharged outside.

To set this mode:

• Press the MODE button a number of times until the dehumidifying symbol appears.

In this mode, fan speed is selected automatically by the appliance and cannot be set manually.

FAN MODE

When using the appliance in this mode, the air hose does not need to be attached.

To set this mode:

Press the MODE button a number of times until the fan symbol appears.

Select the required fan speed by pressing the FAN button. Three speeds are available:

8

Loading...