Datalogic Scanning CBX500 User Manual

4 (2)

CBX500

INSTALLATION MANUAL

1

2

3

 

 

 

4

 

 

 

5

 

 

Figure A

1

Indicator LEDs

4

Compression Connectors (5)

2

Cover Screws (4)

5

25-pin Device Connector

3

Fieldbus Interface Panel

 

 

Datalogic Scanning CBX500 User Manual

CBX500 INSTALLATION MANUAL

6 7 8 9

 

10

5

11

 

4

12

3

13

2

1

14

Figure B

1Power switch (ON/OFF)

2Device Chassis Grounding Selector

3Mounting Holes (2)

4I/O Extension Module Connector

5Backup Module Connector

6Indicator LEDs

7RS485 Termination Resistance Switch

8ID-NET™ Termination Resistance Switch 9 Auxiliary Port Connector

10IP65 Fieldbus Module Connector

11Standard Fieldbus Module Connector

12Spring Clamp Terminal Blocks

13Shield to Protection Earth Selector

14Power Source Selector

2

CBX500 INSTALLATION MANUAL

UPDATES AND LANGUAGE AVAILABILITY

UK/US

The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com

I

Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana.

Collegarsi a: www.automation.datalogic.com

F

Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française.

Cliquez sur : www.automation.datalogic.com

D

Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar.

Adresse : www.automation.datalogic.com

E

En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual.

Dirección Internet : www.automation.datalogic.com

SERVICES AND SUPPORT

Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information including:

PRODUCTS

Search through the links to arrive at your product page where you can download specific Manuals and

Software & Utilities:

SERVICES & SUPPORT

-Datalogic Services - Warranty Extensions and Maintenance Agreements

-Authorised Repair Centres

CONTACT US

E-mail form and listing of Datalogic Subsidiaries

3

CBX500 INSTALLATION MANUAL

DESCRIPTION

The CBX500 is a connection box which can be used as an accessory to facilitate system connections for installation and device replacement of several Datalogic family reading devices.

System cabling is made through spring clamp terminal blocks inside the CBX500 while the reading device is connected to the CBX500 through a 25-pin connector on the housing.

A 9-pin connector placed inside the CBX500 facilitates connection between an external PC and the auxiliary serial interface of the reading device for configuration or data monitoring.

CBX500 can also house several accessories which make the system highly flexible. These include:

Backup Module - to backup and restore system configuration parameters making system maintenance extremely quick and easy.

Display Module – to show reading device menu and diagnostic messages at the CBX500.

Several Host Interface Modules - to interface the scanner with the most popular Fieldbus network types: Ethernet, Profibus; DeviceNet, etc., including IP65 protection versions.

Mounting Adapters – to provide easy mounting to DIN rails and Bosch profiles.

ACCESSORIES

The following accessories are available on request for the CBX500:

Name

Description

Part Number

BM100

Backup Module

93ACC1808

BM150

Display Module

93ACC1809

BM300/310

Profibus Module STD/IP65

93ACC1810, 93ACC1811

BM400

DeviceNet Module IP65

93ACC1814

BM500/510/520

Ethernet/IP Module STD/IP65/IP54

93ACC1812, 93ACC1813, 93ACC1840

BM600

CANopen Module STD

93ACC1815

BM700

Profinet Module STD

93ACC1816

BM1100

CC-Link Module STD

93ACC1845

BM1200/1210

Modbus TCP STD/IP65

93ACC1848, 93ACC1849

BA100

DIN Rail Adapters

93ACC1821

BA200

Bosch Adapters

93ACC1822

BA900

Two Cable Glands Panel

93ACC1847

SAFETY PRECAUTIONS

ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT

POWER SUPPLY

This product is intended to be installed by Qualified Personnel only.

This device is intended to be supplied by a UL Listed NEC Class 2 power source.

Total power consumption is given by adding the CBX500 power consumption to that of all the devices powered through the CBX500 (reading device, P.S., I/O). Refer to the manual of the connected devices for details about minimum/maximum supply voltage and power

consumption.

CAUTION

Each CBX500 supports only 1 single reading device + system accessories.

4

CBX500 INSTALLATION MANUAL

SUPPORTED READING DEVICE MODELS

The CBX500 can be directly connected to the following readers through the 25-pin connector illustrated in Figure A.

 

Linear Scanners

 

2D Readers

 

 

 

 

 

 

DS2100N

DS2400N

DS4800

DS6300

MATRIX-1000

MATRIX-2000

 

 

 

 

 

 

DS6400

DX6400

DS8100A

DX8200A

 

MATRIX 400

 

 

 

 

 

 

CBX500 is backward compatible with DS4600A, DS2100N/DS2400N (black body), and DS1100/DS2200 10-30 Vdc model reading devices using the ADP-MM1 25-pin gender changer. See the Gender Changer documentation for the relative CBX500 pinout.

NOTE

OPENING THE CBX500

To install the CBX500 or during normal maintenance, it is necessary to open it by unscrewing the four cover screws:

The CBX500 must be disconnected from the power supply during this operation.