ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,
Document # PG08-001 |
|
|
|
|
|
PRV30, PRV36, PRV48 |
|
Revised 02/28/14 Page 1/7 |
|||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Renaissance® Slim Chassis |
|
PLANNING |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Downdraft Vents |
|
|
|
GUIDE |
||
Dimensions - models ERV3015, ERV3615 |
|
|
|
|
|
|
|
|
|||||||||||||||||||||||||
|
|
|
|
|
|
warning |
|||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
2 3/16” |
|
|
|
|
• |
Observe all governing codes and ordinances |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
(5.6 cm) |
|
|
|
|
|
|
|
|
during planning and installation. Contact your |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||
|
|
5/16” (8 mm) |
|
|
|
|
2 1/8” |
|
|
|
|
|
|
|
|
|
|
|
local building department for further information. |
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Top cap with |
|
||||||||||||||||||
|
|
thick stiffener |
|
|
(5.4 cm) |
|
|
|
|
|
vent down |
|
• |
This appliance must be installed in accordance |
|||||||||||||||||||
|
|
|
|
|
|
|
|||||||||||||||||||||||||||
|
|
across back |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
with the accompanying installation instructions. |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3/16” |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
(5 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
3” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
(7.6 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9/16” |
|
All tolerances: ±1/16” (±1.6 mm) |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1.4 cm) |
|
unless otherwise stated |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* Total chassis depth with |
|
|
|
|
|
|
|
1 15/16” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
optional CABP3 blower |
|
|
|
|
||||||
|
|
(4.9 cm) |
|
|
|
|
|
|
2 9/16”* |
|
|
|
|
|
|
installed is 10 3/8” (26.3 cm). |
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
(6.5 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Vent shown |
|
|
15" |
|
|
|
|
|
|
|
||
|
|
(38.1 cm) |
|
|
|
|
|
|
||||
in raised |
|
|
|
|
|
|||||||
position |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3/8”
(1.0 cm)
2 1/8” (5.4 cm)
Top cap - side view
20” |
(50.8 cm) |
3 3/4” |
(9.5 cm) |
1 1/8” |
(2.9 cm) |
|
|
B |
Product |
|
|
|
|
|
|
|
data label |
30 1/4” |
30" |
6” |
|
(76.2 cm) |
|
||
(76.8 cm) |
(15.2 cm) |
|
|
to |
|
Motor |
|
37 1/4” |
|
|
|
|
cover |
|
|
(94.6 cm) |
|
28" 3 prong |
|
|
|
||
|
|
Front of unit |
grounded |
|
|
power cord |
|
|
|
Adjustable |
|
|
|
anchor legs |
|
Side View
Model No. |
A |
B |
Circuit |
|
Requirement** |
||||
|
|
|
||
ERV3015 |
30” |
27 3/8” |
Three prong electri- |
|
(76.2 cm) |
(69.5 cm) |
cal outlet connected |
||
|
||||
|
|
|
to 120 Vac, 60 Hz., |
|
|
36” |
33 3/8" |
||
ERV3615 |
15 Amp. grounded, |
|||
(91.4 cm) |
84.8 cm) |
|||
|
dedicated, circuit |
|||
|
|
|
||
** Includes power supply requirements for blower |
|
Front View
NOTES:
1.Maximum installed height must not exceed the maximum specified countertop height of cooking appliance.
2.Install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3.This appliance must be install in conjunction with a single, Dacor approved blower. See page 4/7 for approved blowers.
4.Local building codes may require the use of makeup air systems. Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance.
All specifications subject to change without notice. |
www.dacor.com |
Phone: (800) 793-0093 |
ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,
Document # PG08-001 |
|
|
|
|
|
|
|
|
|
|
|
PRV30, PRV36, PRV48 |
|
Revised 02/28/14 Page 2/7 |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Renaissance Slim Chassis |
|
PLANNING |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Downdraft Vents |
|
GUIDE |
||||
Dimensions - models ERV48, PRV30, prv36, PRV48 |
|
|
|
||||||||||||||||||||||||||
|
warning |
||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Observe all governing codes and ordinances |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
during planning and installation. Contact your |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
local building department for further information. |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• This appliance must be installed in accordance |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
with the accompanying installation instructions. |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All tolerances: ±1/16” (±1.6 mm) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
unless otherwise stated |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3/8" (1.0 cm)
|
|
|
|
|
|
|
|
|
|
A |
|
|
|
|
|
2 1/8" (5.4 cm) |
|
|
|
|
|
|
|
|
|
||||
|
|
ERV top cap - side view |
|||||||
|
|||||||||
|
|
|
|
|
|
|
|
|
|
7/16"
(1.1 cm) 2 1/8" (5.4 cm)
PRV top cap - side view
B |
Side View
Model No. |
A |
B |
Circuit |
|
Requirement** |
||||
|
|
|
||
PRV30 |
30” |
27 3/8” |
|
|
(76.2 cm) |
(69.5 cm) |
|
||
|
|
|||
PRV36 |
36” |
33 3/8” |
Three prong electri- |
|
(91.4 cm) |
84.8 cm) |
cal outlet connected |
||
|
to 120 Vac, 60 Hz, |
|||
|
46” |
43 3/8” |
||
PRV46 |
15 Amp. grounded, |
|||
(116.8 cm) |
(110.2 cm) |
|||
|
dedicated, circuit |
|||
ERV48 |
48” |
43 3/8” |
|
|
(121.9 cm) |
(110.2 cm) |
|
||
|
|
** Includes power supply requirements for external blower
Front View
NOTES:
1.Maximum installed height must not exceed the maximum specified countertop height of cooking appliance.
2.Install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3.This appliance must be install in conjunction with a single Dacor approved blower. See page 4/7 for approved blowers.
4.Local building codes may require the use of makeup air systems. Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance.
All specifications subject to change without notice. |
www.dacor.com |
Phone: (800) 793-0093 |
ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER,
Document # PG08-001 |
PRV30, PRV36, PRV48 |
Revised 02/28/14 Page 3/7 |
|
||
|
Renaissance Slim Chassis |
PLANNING |
|
Downdraft Vents |
GUIDE |
Dimensions - models ERV36-er, ERV48-er
|
|
|
|
|
|
|
|
|
1/4" |
|
|
|
|
|||
5/16” (8 mm) |
|
|
|
(6 mm) |
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
thick stiffener |
|
|
|
|
|
|
|
|
|
2 13/16" |
||||||
|
across back |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(7.1 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 1/2" |
|
|
|
|
|
|
|
|
|
|
|
|
|
Top cap with |
||
(6.4 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
vent down |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 15/16" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
(4.9 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
2 9/16" |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
(6.5 cm) |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
warning
•Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
•This appliance must be installed in accordance with the accompanying installation instructions.
All tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated
Model Number |
A |
B |
ERV36-ER |
36” (91.4 cm) |
33 3/8” (84.8 cm) |
|
|
|
ERV48-ER |
48” (121.9 cm) |
43 3/8” (110.2 cm) |
NOTE: See the appliance planning guide page for cutout dimensions
A
Vent shown |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
in raised |
10" |
|
|
|
|
|
|
|
||||
position |
(25.4 cm) |
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18 5/8” |
(47.3 cm) |
3 3/4" |
(9.5 cm) |
1" |
(2.5 cm) |
|
|
B |
Product |
|
|
|
|
|
|
|
data label |
30 ¼" |
30" |
6" |
|
(76.2 cm) |
|
||
(76.8 cm) |
(15.2 cm) |
|
|
to |
|
Motor |
|
37 ¼" |
|
|
|
|
cover |
|
|
(94.6 cm) |
|
28" 3 prong |
|
|
|
||
|
|
|
grounded |
|
|
Front of unit |
power cord |
|
|
Adjustable |
|
|
|
anchor legs |
|
NOTES:
1.Maximum installed height must not exceed the maximum specified countertop height of cooking appliance.
2.Install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information.
3.This appliance must be install in conjunction with a single Dacor approved blower. See page 4/7 for approved blowers.
4.Local building codes may require the use of makeup air systems. Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance.
Circuit Requirement (all models)*
Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, circuit
* Includes power supply requirements for external blower.
All specifications subject to change without notice. |
www.dacor.com |
Phone: (800) 793-0093 |