Cleveland Range PEM-48-3 User Manual

Size:
109.04 Kb
Download

Project ________________________________

 

 

Cleveland

Item __________________________________

 

 

Q

tity _______________________________

 

FCSI Section ____________________________

PRESSURE STEAMERS

Approval _______________________________

Date __________________________________

PRESSURE STEAMERS

2 OR 3 COMPARTMENTS, CABINET MOUNTED ELECTRIC STEAM GENERATOR

24, 36 OR 48 KW, 36” WIDE CABINET BASE

Cleveland Standard Features

5 psi Operating Pressure in cooking compartments

Mechanical interlock prevents unlatching door while compartment is pressurized

Timers, one per compartment, are mechanical style with audible signal

Thermostatic Trap vents cooking compartment automatically

Steam Inlet Valves and Exhaust Valves interlocked for synchronous action

8 psi Compartment Safety Valve

Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans

Heavy Duty, free floating, cast aluminum compartment doors

Compartment Door Hinges have adjustable hinge pins andself-lubricatingbushings

Door Gasket replaceable without tools

Pressure Gauge for compartment operating pressure

Compartment Slide Racks are removable without tools, for easy cleaning

Type 430 Stainless Steel: external enclosure, Table Top and eight gage plate cooking compartments

Modular Cabinet Base with Hinged Doors

High efficiency Electric Steam Generator with Automatic Water Fill onstart-up

Automatic Water Level Control System with Low Water PowerCut-offCircuit

Steam Generator equipped withHigh-limitPressure Safety Switch and Safety Valve

Automatic Steam Generator (boiler) Blowdown allows intermittent control, complete with additional Manual Drain Valve

Steam Generator Pressure Gauge

6” Stainless Steel Legs with level adjustment and flanged feet

Single Cold Water Connection (no hot water required)Secondary Low WaterCut-Off,factory installed (CALE)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)

Standard Voltage 208-240volts, 60 hz, single phase, three wire

All Major Components are serviceable from the front of unit

Options & Accessories

Automatic Steam Inlet and Exhaust Operation (AT-2):includes 60 minute Automatic Timers and Manual Bypass

MODELS:

2 Compartments

3 Compartments

 

c PEM-24-2

c PEM-24-3

 

c PEM-36-2

c PEM-36-3

 

c PEM-48-2

c PEM-48-3

Short Form Specifications

Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model PEM_____ - _____ , Electric Steam Generator, _____ kw,

_____ volts, _____ ph, three wire. Each Cooking Compartment equipped with: 60 Minute Timer; Heavy-duty,free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Solid State Controls operate Water Level and Steam Generator (boiler) Safety Functions. Automatic Steam Generator (boiler) Blowdown with additional Manual Drain Valve.

15 psi for Kettle Operation, includes Power Take-Off(PTO)

Kettle Interconnecting Kit (IMK)

Stainless Steel base Frame (FSS)

Stainless Steel gas flue cover, insulated (SSF)

Special compartment Slide Racks

12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep

Intermediate Pull-OutShelf (POS)

Spray Head with flexible Hose (SH)

Voltages, other than standard

Water Filters

Correctional Packages

SECT. VI PAGE1 0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

ELECTRIC

KW Volts

Watts

Ph Amps Wire

24

208

21,500

1

103.4

2

 

 

 

 

 

 

 

220

24,000

1

109.1

2

 

240

24,000

1

100.0

2

 

 

 

 

 

 

 

440

20,200

1

45.9

2

 

 

 

 

 

 

 

480

24,000

1

50.0

2

 

 

 

 

 

 

 

208

21,500

3

59.7

3

 

220

24,000

3

63.1

3

 

 

 

 

 

 

 

240

24,000

3

57.8

3

 

 

 

 

 

 

 

440

20,200

3

26.5

3

 

480

24,000

3

28.9

3

 

 

 

 

 

 

 

600

24,000

3

23.1

3

 

 

 

 

 

 

 

360

21,500

3

34.5

4

 

 

 

 

 

 

 

380

24,000

3

36.5

4

 

415

24,000

3

33.4

4

 

 

 

 

 

 

KW Volts Watts Ph Amps Wire

36

208

32,200

3

89.5

3

 

 

220

36,000

3

94.6

3

 

 

240

36,000

3

86.7

3

 

 

440

30,200

3

39.7

3

 

 

480

36,000

3

43.4

3

 

 

600

36,000

3

34.7

3

 

 

360

32,200

3

51.7

4

 

 

380

36,000

3

54.8

4

 

 

415

36,000

3

50.1

4

 

48

208

42,900

3

119.2

3

 

 

220

48,000

3

126.1

3

 

 

240

48,000

3

115.6

3

 

 

440

40,300

3

52.9

3

 

 

480

48,000

3

57.8

3

 

 

600

48,000

3

46.2

3

 

 

360

42,900

3

68.9

4

 

 

380

48,000

3

73.0

4

 

 

415

48,000

3

66.9

4

Cleveland Range reserves right of design improvement or modification, as warranted.

Each compartment has capacity for:

Eight,

12˝ x 20˝ x 212˝

Cafeteria Pans or

Six,

12˝ x 20˝ x 4˝

Cafeteria Pans or

Four,

12˝ x 20˝ x 6˝

Cafeteria Pans or

Four,

18˝ x 26˝

Bun Pans

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with those codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards whether untreated or pre-treated,based upon 10 hours of use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.

WATER

DRAINAGE

 

 

CLEARANCE

D

 

 

 

 

 

 

1/4˝ NPT

The Floor Drain must be located

Right - 3”, Left - 3”,

Cold Water Inlet

outside the confines of the

Rear - 3” (12” on control

35 psi minimum

equipment base.

side if adjoining wall or

 

 

 

equipment is over 30” high

60 psi maximum

1 1/2˝ I.P.S. common drain.

for service access)

Do not connect other units to this

 

Contact factory for

 

drain.

 

Do not use PVC pipe for drain.

variances to clearances.

 

 

 

 

 

(NOT TO SCALE) SECT.VI PAGE2 0707