Cleveland Range KDL-25-T, KDL-60-T, KDL-40-T User Manual

Size:
218.15 Kb
Download

Project ________________________________

 

 

Cleveland

Item __________________________________

 

 

Q

tity _______________________________

 

F

ction ____________________________

DIRECT STEAM KETTLES

Approval _______________________________

Date __________________________________

TRI-LEG,DIRECT STEAM

TILTING, 2⁄3 STEAM JACKETED

25, 40 or 60 GALLONS (100, 150 or 225 LITERS)

Cleveland Standard Features

Kettle legs of 158˝ OD, type 304 Stainless Steel, with 3 level adjustable feet, withthree-boltflanges for floor bolting

Type 304 Stainless Steel construction, with #4 finish on kettle and supports

Tilting Mechanism with permanently lubricated, self-locking,Worm Drive of space saving design

50 psi Steam Jacket Rating

50 psi chrome plated Safety Valve

High Capacity Pouring Lip

Condensate Drain Valve with insulated handle

Steam Control Valve mounted on console

Typical approvals include NSF and ASME

Options & Accessories

Type 316 Stainless Steel Kettle Liner for high acid food products (316)

Lift-offCovers (CL)

Steam Control Kit includes: Steam Trap, Condensate Strainer, Check Valve, nipples and fittings, factory assembled and mounted on kettle (SCK2)

Spring-assisted,hinged, rotatable, domed Stainless Steel Cover(CHS-)

Hot and Cold Water Faucet, comes with Swing Spout (DPK)

2˝ or 3" diameter Tangent Draw-OffValve (TD2 or TD3*), *TD3 for 60 gallon only and will raise height of kettle by5-5/8"(143mm)

3" diameter Butterfly Valve (BV3)

Cooking Baskets and Tri-BasketSupports (BS and TBS)

Pan Carrier (PCK)

Measuring Strips (MS)

Gallon Markings (KM)

Kettle Accessory Kit (KAK) includes:

Clean-upBrush (CB) 36˝ Kettle Paddle (KP)

36˝ Kettle Whip (KW) 36˝ Kettle Brush (KB)

Draw-offBrush (DB) 24 oz. Ladle (KL)

Swing Funnels for drain (SF)

Faucet Mounting Bracket (FBKT)

Pressure Reducing Valve for regulating incoming

steam pressure of over 45 psi (PRV-K)

Hot and cold, or cold only, Kettle Filler with 60˝ Hose (DKF-KorSKF-K)

MODELS:c KDL-25-T

c KDL-60-T

c KDL-40-T

 

Shown with optional Spring-AssistedCover, 2" TangentDraw-OffValve

Short Form Specifications

Shall be CLEVELAND, Direct Steam Kettle, Tri-legmounted, Model KDL - _____ - T, _____ gallons, Tilting (hand or power) 2 3 Steam Jacketed. Type 304 Stainless Steel kettle and support legs. 50 psi Steam Jacket Rating; Steam Control Valve; heavyre-enforcedRolled Rim. To operate, connect directly to a steam source supplying 10 to 45 psi steam.

Automatic Water Cooling* (AWC-1)

*requires Console Mounting Option

Alternate Mounting Systems - Console Mounting

Automatic Water Meter (GMF or LMF)

Water Meter Stand (SWM)

Food Strainer (FS)

Flow Diverter (FD)

Drain Strainers (DS-)

Pre-RinseSpray Head and Hose (PRSK)

Heat Deflector Shield (HS001)

Correctional Packages

SECT. X PAGE9 0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.com

 

 

 

 

 

CAPACITIES: (in 8 oz. servings,

 

 

A1

 

 

 

other sizes may be calculated.)

 

 

MANUAL TILT

 

 

 

 

25 Gallon / 100 liters . . . 400 servings

 

 

A2

 

 

 

 

40 Gallon / 150 liters . . . 640 servings

 

 

EXTENDED FOR

 

 

 

60 Gallon / 225 liters . . . 960 servings

 

 

POWER TILT OPTION

 

 

 

 

 

 

 

 

 

 

 

POWER TILT

 

 

 

 

 

 

 

 

 

 

 

 

 

L

K

 

 

C

S

 

 

 

 

2 3/4

B

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

7/16" (11 mm) Ø

4 7/8"

 

 

 

 

 

 

3 HOLES ON

124 Ø mm

 

 

 

 

 

 

3 1/8" (80 mm) Ø

 

 

N

 

 

 

 

 

B.C.D.

 

 

 

 

 

 

D

 

120º

 

 

 

 

 

 

 

TYP

 

 

 

 

 

 

 

1 5/8" (42 mm) Ø

 

 

 

 

 

 

NOTE: TD3, 3" tangent draw off will

 

 

 

 

 

 

 

raise height of kettle by 5-5/8"(143mm).

 

 

 

 

 

 

 

Available on 60 gallon models only.

MAX. ADJUSTMENT

14 mm

 

 

FLOOR DRAIN

 

 

1" (25 mm)

 

9/16"

 

 

 

 

 

 

FLANGED FOOT DETAIL

 

 

(18" WIDE)

 

 

 

 

O

 

 

 

HANDWHEEL REPLACED BY

 

 

 

 

 

 

 

 

SWITCH FOR POWER

4" (102 mm)

RECOMMENDED

 

 

 

 

 

TILT OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

T (I.D.)

RECOMMENDED

FLOOR SLOPE

 

 

 

 

 

 

1" (26 mm) per 4' (1220 mm)

 

 

H

C

 

 

 

 

 

 

 

E

 

 

PIPE DRAIN RECOMMENDED

 

 

 

 

 

 

min. valve size plus 1" (26 mm)

 

 

 

 

 

 

F

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFFVALVE,

SPRING ASSIST COVER, HOT AND COLD WATER FAUCED AND STEAM CONTROL KIT.

DIMENSIONS

GALS./

 

A1

A2

B

C

D

E

F

G

H

J

K

L

M

N

0

S

T I.D.

LITERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

IN

37 5/8

35 1/2

33 3/8

28 5/8

15 3/8

61 7/8

36 5/8

14

18 1/2

15 1/2

14 1/2

14 1/4

21 5/8

49 1/4

3 7/8

29 5/8

21

100

mm

957

902

848

728

391

1572

931

356

470

394

369

362

550

1251

99

753

534

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

IN

41 5/8

39 1/2

34 3/4

30

17 7/8

65 7/8

36 7/8

12 1/4

19

16 1/2

17

16 3/4

23 3/8

51 1/8

6 3/8

32 3/8

26

150

mm

1058

1004

883

762

455

1674

937

312

483

420

432

426

594

1299

162

823

661

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

IN

45 1/8

43

38

33 3/8

19 5/8

74 1/8

40 7/8

12 3/4

20 1/4

18 1/2

18 3/4

18 1/2

26 5/8

56 3/8

8 1/8

36 1/4

29 1/2

225

mm

1147

1093

966

848

499

1883

1039

324

515

470

477

470

677

1432

207

921

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

(NOT TO SCALE) SECT.X PAGE10 0707

Litho in U.S.A.