PRESSURE STEAMERS

Approval _______________________________

Date __________________________________

PRESSURE STEAMERS

2 OR 3 OR 4 COMPARTMENTS

DIRECT STEAM, OPEN STAND PEDESTAL BASE OR WALL MOUNTED

Cleveland Standard Features

5 psi Operating Pressure in cooking compartments

Mechanical interlock prevents unlatching door while compartment is pressurized

Timers, one per compartment, are mechanical style with audible signal

Thermostatic Trap vents cooking compartment automatically

Steam Inlet Valves and Exhaust Valves interlocked for synchronous action

8 psi Compartment Safety Valve

Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans

Heavy Duty, free floating, cast aluminum compartment doors

Compartment Door Hinges have adjustable hinge pins and self-lubricatingbushings

Door Gasket replaceable without tools

Pressure Gauge for compartment Operating Pressure

Compartment Slide Racks are removable without tools, for easy cleaning

Type 430 Stainless Steel: external enclosure, Table Top and eight gauge plate cooking compartments

Moisture Separator for incoming steam

Pressure Reducing Valve for 12 to 50 psi steam supply pressure

6” Adjustable Legs with flanged feet

MODELS:

2 Compartments

3 Compartments

4 Compartments

 

c PDL-2

c PDL-3

c PDL-4

 

c PDW-2

c PDW-3

c PDW-4

Short Form Specifications

Shall be _____ Compartments, CLEVELAND, Pressure Steamer, Model PD_____ - _____ , for Direct Steam operation,; _____ volts, single phase. Each Cooking Compartment equipped with: 60 Minute Timer; Pressure Safety Valve; Heavy-duty,free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Compartments are mounted to a Low Cabinet type base or Wall Mounted. Includes a Pressure Reducing Valve and Moisture Separator.

Options & Accessories

Automatic Steam Inlet and Exhaust Operation (AT-2):

 

 

 

 

 

 

includes 60 minute Automatic Timers and Manual Bypass

 

 

 

 

 

Second Pressure Reducing Valve for 50 to 120 psi supply

 

 

 

 

 

 

pressure (PRV)

 

 

 

 

 

 

 

Special Compartment Slide Racks

 

 

 

 

 

 

 

12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep

 

 

 

 

 

 

Intermediate Pull-OutShelf (POS)

 

 

 

 

 

 

 

In-WallCarrier, for wall mounted units only(IWC-PDW)

 

 

 

 

 

Clean, non toxic, uncontaminated steam is required for all

 

 

 

 

 

SECT. VI PAGE9

 

“Direct Steam” steamers

 

 

 

 

 

 

 

 

0707

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1333 East 179 S

T

216-481-4900

 

 

 

 

 

W

ite: www.ClevelandRange.

 

 

 

 

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

 

 

 

 

 

 

 

 

 

 

 

 

Each compartment has capacity for:

Eight,

12˝ x 20˝ x 212˝

Cafeteria Pans or

Six,

12˝ x 20˝ x 4˝

Cafeteria Pans or

Four,

12˝ x 20˝ x 6˝

Cafeteria Pans or

Four,

18˝ x 26˝

Bun Pans

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with those codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, ULC, NSF, and CSA.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards whether untreated or pre-treated,based upon 10 hours of use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.

WALL MOUNTED

LOW-CABINETTYPE

1” IPS common drain.

Do not connect other units to this drain.

Do not use PVC pipe for drain.

Cleveland Range reserves right of design improvement or modification, as warranted.

Right - 3”, Left - 3”, Rear - 3”

(12” on control side if adjoining wall or equipment is over 30” high for service access)

Contact factory for variances to clearances.

(NOT TO SCALE) SECT. VI PAGE10 0707