Cleveland Range CSTK-610 User Manual

Size:
620.92 Kb
Download

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Gas Table Type Models

(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

Model #

Description

CSTK-610

for mounting two 6.10 models

CSTK-610CA

for mounting two 6.10 models (with casters)

 

 

LEFT SIDE VIEW

 

 

 

 

 

39.21"

 

 

 

 

 

 

UNIT A

 

 

HOOD REQUIREMENT)

 

 

 

 

 

 

67.85"

G

D

W1 W2

RC

CS

78.00”(MIN.

 

 

 

 

 

U

 

 

38

 

 

 

 

 

 

 

 

 

 

 

 

4.38"

 

 

36.70"

 

2.52"

1.58"

1.82"

 

 

28.43

UNIT A

 

 

 

5.00"

 

 

28.43

U

 

 

 

6.00"

 

 

G D W1 W2

RC CS

N

Overall height of unit d

not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

 

Electrical Requirements:

120 volt, 60 Hz, single phase, UNIT A - 11.7 amps

 

Do not connect to a G.F.I. outlet.

 

UNIT B - 11.7 amps

 

 

 

 

G

Gas Connection:

3/4" NPT

 

 

Gas Type:

Natural Gas (Propane optional)

 

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

 

 

Propane Gas - Min. 11" WC / Max. 14" WC

 

 

 

 

 

BOILER MODELS

UNIT A -OGB-6.10

UNIT B -OGB-6.10

 

Total Connected Load:

45.400 BTU

45.400 BTU

 

Steam Generator:

45.400 BTU

45.400 BTU

 

Hot Air:

45.400 BTU

45.400 BTU

 

 

 

 

 

BOILERLESS MODELS

UNIT A -OGS-6.10

UNIT B -OGS-6.10

 

Total Connected Load:

45.400 BTU

45.400 BTU

 

Hot Air:

45.400 BTU

45.400 BTU

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

Water Inlets:

3/4" GHT-F(Female Garden Hose Connection)

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

D Drain Connection:

2" Tube

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

CS *Connection for Cleaning Solution

RC *Connection for Rinse Cycle

*Available as an option

Note: For additional connection details, see spec sheet for each individual combi model to be stacked.

SECT. IIB PAGE5A 0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Gas Table Type Models

(OGB 6.10 on OGB 10.10 or OGS 6.10 on OGS 10.10)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

Model #

Description

CSTK-1010

for mounting one 6.10 model on top of one 10.10 model

CSTK-1010CA

for mounting one 6.10 model on top of one 10.10 model (with casters)

LEFT SIDE VIEW

39.21"

U

G

D

W1

W2

RC

CS

 

 

U

 

 

48

4.38"

 

 

 

 

 

 

REQUIREMENT)

 

78.41"

 

80.00”(MIN. HOOD

 

 

 

 

 

36.70"

 

2.52"

1.58"

1.82"

 

 

28.43

U

 

 

 

5.00"

 

 

38.98"

U

 

6.00"

 

 

G D W1 W2

RC CS

N Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

 

Electrical Requirements:

120 volt, 60 Hz, single phase, UNIT A - 11.7 amps

 

Do not connect to a G.F.I. outlet.

 

UNIT B - 11.7 amps

 

 

 

 

G

Gas Connection:

3/4" NPT

 

 

Gas Type:

Natural Gas (Propane optional)

 

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

 

 

Propane Gas - Min. 11" WC / Max. 14" WC

 

BOILER MODELS

UNIT A -OGB-6.10

UNIT B -OGB-10.10

 

Total Connected Load:

45.400 BTU

75,700 BTU

 

Steam Generator:

45.400 BTU

68,200 BTU

 

Hot Air:

45.400 BTU

75,700 BTU

 

 

 

 

 

BOILERLESS MODELS

UNIT A -OGS-6.10

UNIT B -OGS-10.10

 

Total Connected Load:

45.400 BTU

75,700 BTU

 

Hot Air:

45.400 BTU

75,700 BTU

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

Water Inlets:

3/4" GHT-F(Female Garden Hose Connection)

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

D Drain Connection:

2" Tube

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

CS *Connection for Cleaning Solution

RC *Connection for Rinse Cycle

*Available as an option

Note: For additional connection details, see spec sheet for each individual combi model to be stacked.

SECT. IIB PAGE5B 0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Gas Table Type Models

(OGB 6.20 on OGB 6.20 or OGS 6.20 on OGS 6.20)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

byCleveland

LEFT SIDE VIEW

47.72"

UNIT A

G

D

W1

W2

RC

CS

 

 

U

 

 

39

 

 

 

 

 

4.38"

Model #

Description

CSTK-620for mounting two 6.20 modelsCSTK-620CAfor mounting two 6.20 models (with casters)

 

 

 

FRONT VIEW

 

 

 

 

47.92"

 

 

 

2.52"

1.58"

1.82"

 

 

 

 

HOODREQUIREMENT)

 

30.12"

U

 

 

 

 

71.24"

5.00"

 

 

 

 

 

 

78.00”(MIN.

 

30.12"

 

 

 

 

U

 

 

 

 

 

 

 

6.00"

 

 

G D W1 W2

RC CS

N

Overall height of unit d

not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

 

Electrical Requirements:

120 volt, 60 Hz, single phase, UNIT A - 11.7 amps

 

Do not connect to a G.F.I. outlet.

 

UNIT B - 11.7 amps

 

 

 

 

 

G

Gas Connection:

3/4" NPT

 

 

 

Gas Type:

Natural Gas (Propane optional)

 

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

 

 

Propane Gas - Min. 11" WC / Max. 14" WC

 

 

 

 

 

 

BOILER MODELS

UNIT A -OGB-6.20

UNIT B -OGB-6.20

 

Total Connected Load:

75,700 BTU

75,700 BTU

 

Steam Generator:

68,200 BTU

68,200 BTU

 

Hot Air:

75,700 BTU

75,700 BTU

 

 

 

 

 

 

BOILERLESS MODELS

UNIT A -OGS-6.20

UNIT B -OGS-6.20

 

Total Connected Load:

75,700 BTU

75,700 BTU

 

Hot Air:

75,700 BTU

75,700 BTU

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

Water Inlets:

3/4" GHT-F(Female Garden Hose Connection)

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

D Drain Connection:

2" Tube

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

CS *Connection for Cleaning Solution

RC *Connection for Rinse Cycle

*Available as an option

Note: For additional connection details, see spec sheet for each individual combi model to be stacked.

SECT. IIB PAGE5C 0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Gas Table Type Models

(OGB 6.20 on OGB 10.20 or OGS 6.20 on OGS 10.20)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

byCleveland

LEFT SIDE VIEW

47.72"

UNIT A

G

D

W1

W2

RC

CS

 

 

U

 

 

48

4.38"

Model #

Description

CSTK-1020for mounting one 6.20 model on top of one 10.20 modelCSTK-1020CAfor mounting one 6.20 model on top of one 10.20 model (with casters)

 

 

 

F

IEW

 

 

 

 

 

47.92"

 

 

 

2.52"

1.58"

1.82"

 

 

 

 

 

 

30.12"

 

U

 

 

 

 

 

 

REQUIREMENT)

80.09"

5.00"

 

 

 

 

 

 

 

 

HOOD

 

 

 

 

 

81.00”(MIN.

 

38.98"

 

U

 

 

 

 

 

 

 

 

6.00"

 

 

 

G D W1 W2

RC CS

N Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

 

Electrical Requirements:

120 volt, 60 Hz, single phase, UNIT A - 11.7 amps

 

Do not connect to a G.F.I. outlet.

 

UNIT B - 15.9 amps

 

 

 

 

 

G

Gas Connection:

3/4" NPT

 

 

 

Gas Type:

Natural Gas (Propane optional)

 

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

 

 

Propane Gas - Min. 11" WC / Max. 14" WC

 

 

BOILER MODELS

UNIT A -OGB-6.20

UNIT B -OGB-10.20

 

Total Connected Load:

75,700 BTU

132,700 BTU

 

Steam Generator:

68,200 BTU

113,600 BTU

 

Hot Air:

75,700 BTU

132,700 BTU

 

 

 

 

 

 

BOILERLESS MODELS

UNIT A -OGS-6.20

UNIT B -OGS-10.20

 

Total Connected Load:

75,700 BTU

132,700 BTU

 

Steam Generator:

75,700 BTU

132,700 BTU

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

Water Inlets:

3/4" GHT-F(Female Garden Hose Connection)

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

D Drain Connection:

2" Tube

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

CS *Connection for Cleaning Solution

RC *Connection for Rinse Cycle

*Available as an option

Note: For additional connection details, see spec sheet for each individual combi model to be stacked.

SECT. IIB PAGE5D 0707

1333 East 179 St.,

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U.S.A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.10 on OEB 6.10 or OES 6.10 on OES 6.10)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

 

Model #

Description

 

CSTK-610

for mounting two 6.10 models

byCleveland

CSTK-610CA

for mounting two 6.10 models (with casters)

L

 

DE VIEW

 

 

 

 

 

 

37.83"

 

 

 

 

 

 

UNIT A

 

 

 

HOOD REQUIREMENT)

 

 

 

 

 

 

 

67.85"

D

W1

W2

RC

CS

 

78.00”(MIN.

 

 

 

 

 

U

 

 

 

 

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.38"

 

D

W1

W2

RC

CS

N

Overall height of u

 

 

36.70"

 

2.52"

1.58"

1.82"

 

 

28.43

UNIT A

 

 

 

5.00"

 

 

28.43

UNIT B

 

 

 

6.00"

 

 

oes not change for units with c ers.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Electrical Requirements:

Do not connect to a G.F.I. outlet.

 

 

 

BOILER

 

UNIT A -OEB-6.10

 

 

UNIT B -OEB-6.10

 

 

 

 

 

 

 

MODELS

 

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

Total Connected Load:

 

9.9 KW

12.8 KW

11 KW

13.1 KW

9.9 KW

12.8 KW

11 KW

13.1 KW

Hot Air:

 

8.6 KW

11.4 KW

9.1 KW

10.2 KW

8.6 KW

11.4 KW

9.1 KW

10.2 KW

Steam Generator:

 

7.7 KW

10.2 KW

8.6 KW

10.2 KW

7.7 KW

10.2 KW

8.6 KW

10.2 KW

Amps per Phase:

 

27.3

30.8

15.2

16.3

27.3

30.8

15.2

16.3

 

 

 

 

 

 

 

 

BOILERLESS

 

UNIT A -OES-6.10

 

 

UNIT B -OES-6.10

 

 

MODELS

 

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

Total Connected Load:

 

9.9 KW

12.8 KW

11 KW

13.1 KW

9.9 KW

12.8 KW

11 KW

13.1 KW

Hot Air:

 

8.6 KW

11.4 KW

9.1 KW

10.2 KW

8.6 KW

11.4 KW

9.1 KW

10.2 KW

Amps per Phase:

 

27.3

30.8

15.2

16.3

27.3

30.8

15.2

16.3

 

 

 

 

 

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

 

 

Water Inlets:

3/4" GHT-F(Female Garden Hose

 

 

Connection)

 

 

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

 

 

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

 

 

see spec sheet for each individual

 

SECT. IIB PAGE5E

 

combi model to be stacked.

 

 

0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.10 on OEB 10.10 or OES 6.10 on OES 10.10)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

 

Model #

Description

 

CSTK-1010

for mounting one 6.10 model on top of one 10.10 model

byCleveland

CSTK-1010CA

for mounting one 6.10 model on top of one 10.10 model (with casters)

L

DE VIEW

 

37.83"

 

UNIT A

D

W1

W2

RC

CS

 

U

 

 

48

4.38"

 

 

 

 

 

 

REQUIREMENT)

 

78.41"

 

80.00”(MIN. HOOD

 

 

 

 

 

36.70"

 

2.52"

1.58"

1.82"

 

 

28.43

UNIT A

 

 

 

5.00"

 

 

38.98"

UNIT B

 

6.00"

 

 

D W1 W2

RC CS

N

Overall height of u

oes n change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Electrical Requirements: Do not connect to a G.F.I. outlet.

BOILER

UNIT A -OEB-6.10

 

 

UNIT B -OEB-10.10

 

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

 

Total Connected Load:

9.9 KW

12.8 KW

11 KW

13.1 KW

16.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

8.6 KW

11.4 KW

9.1 KW

10.2 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Steam Generator:

7.7 KW

10.2 KW

8.6 KW

10.2 KW

12.8 KW

17.1 KW

14.3 KW

17.1 KW

Amps per Phase:

27.3

30.8

15.2

16.3

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

BOILERLESS

UNIT A -OES-6.10

 

 

UNIT B -OES-10.10

 

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

 

Total Connected Load:

9.9 KW

12.8 KW

11 KW

13.1 KW

6.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

8.6 KW

11.4 KW

9.1 KW

10.2 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Amps per Phase:

27.3

30.8

15.2

16.3

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

 

 

Water Inlets:

3/4" GHT-F(Female Garden Hose

 

 

Connection)

 

 

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

 

 

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

 

 

see spec sheet for each individual

 

SECT. IIB PAGE5F

 

combi model to be stacked.

 

 

0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.20 on OEB 6.20 or OES 6.20 on OES 6.20)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

LEFT SIDE VIEW

46.34"

UNIT A

D

W1

W2

RC

CS

 

U

 

 

 

 

 

 

 

39

4.38"

Model #

Description

CSTK-620for mounting two 6.20 modelsCSTK-620CAfor mounting two 6.20 models (with casters)

 

 

 

FRONT VIEW

 

 

 

 

47.92"

 

 

 

2.52"

1.58"

1.82"

 

 

 

 

 

 

30.12"

U

 

 

 

 

 

REQUIREMENT)

71.20"

5.00"

 

 

 

 

 

 

HOOD

 

30.12"

 

 

78.00”(MIN.

 

U

 

 

 

 

 

 

 

6.00"

 

 

D W1 W2

RC CS

N

Overall height of unit does not change for units with c ers.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Electrical Requirements:

Do not connect to a G.F.I. outlet.

 

 

 

BOILER

 

UNIT A -OEB-6.20

 

 

UNIT B -OEB-6.20

 

 

 

 

 

 

 

MODELS

 

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

Total Connected Load:

 

16.4 KW

21.6 KW

18.5 KW

22 KW

16.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

 

14.7 KW

19.6 KW

16.5 KW

19.6 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Steam Generator:

 

12.8 KW

17.1 KW

14.3 KW

17.1 KW

12.8 KW

17.1 KW

14.3 KW

17.1 KW

Amps per Phase:

 

45.5

51.8

24.2

26.4

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

BOILERLESS

 

UNIT A -OES-6.20

 

 

UNIT B -OES-6.20

 

 

MODELS

 

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

Total Connected Load:

 

16.4 KW

21.6 KW

18.5 KW

22 KW

16.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

 

14.7 KW

19.6 KW

16.5 KW

19.6 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Amps per Phase:

 

45.5

51.8

24.2

26.4

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

 

 

Water Connections:

Flow Pressure:

Water Inlets:

W1

W2

Cold Water (drinking water quality) 30 - 60 PSI

3/4" GHT-F(Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

see spec sheet for each individual

SECT. IIB PAGE5G

 

combi model to be stacked.

 

0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.

Cleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)

Project ________________________________

Item __________________________________

Q tity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

byCleveland

L DE VIEW

46.34"

U

D

W1

W2

RC

CS

 

U

 

 

48

4.38"

Model #

Description

CSTK-1020for mounting one 6.20 model on top of one 10.20 modelCSTK-1020CAfor mounting one 6.20 model on top of one 10.20 model (with casters)

 

 

 

FRONT VIEW

 

 

 

 

47.92"

 

 

 

2.52"

1.58"

1.82"

 

 

 

 

 

 

30.12"

U

 

 

 

 

 

REQUIREMENT)

80.09"

5.00"

 

 

 

 

 

 

(MIN. HOOD

 

38.98"

 

 

81.00”

 

U

 

 

 

 

 

 

 

6.00"

 

 

D W1 W2

RC CS

N Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Electrical Requirements: Do not connect to a G.F.I. outlet.

BOILER

UNIT A -OEB-6.20

 

 

UNIT B -OEB-10.20

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

Total Connected Load:

16.4 KW

21.6 KW

18.5 KW

22 KW

26.3 KW

34.9 KW

29.4 KW

34.9 KW

Hot Air:

14.7 KW

19.6 KW

16.5 KW

19.6 KW

25.8 KW

34.3 KW

28.8 KW

34.3 KW

Steam Generator:

12.8 KW

17.1 KW

14.3 KW

17.1 KW

20.5 KW

27.3 KW

22.9 KW

27.3 KW

Amps per Phase:

45.5

51.8

24.2

26.4

77.8

88.8

41.4

44.9

 

 

 

 

 

 

BOILERLESS

UNIT A -OES-6.20

 

 

UNIT B -OES-10.20

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

Total Connected Load:

16.4 KW

21.6 KW

18.5 KW

22 KW

26.3 KW

34.9 KW

29.4 KW

34.9 KW

Hot Air:

14.7 KW

19.6 KW

16.5 KW

19.6 KW

25.8 KW

34.3 KW

28.8 KW

34.3 KW

Amps per Phase:

45.5

51.8

24.2

26.4

77.8

88.8

41.4

44.9

 

 

 

 

 

 

 

 

 

Water Connections:

Flow Pressure:

Water Inlets:

W1

W2

Cold Water (drinking water quality) 30 - 60 PSI

3/4" GHT-F(Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

see spec sheet for each individual

SECT. IIB PAGE5H

 

combi model to be stacked.

 

0707

1333 East 179 S

T

216-481-4900

W

ite: www.ClevelandRange.

C eland, Ohio, U A. 44110

F

16-481-3782

Em

eam@ClevelandRange.