C H A P T E R 4

Storage/Control I/O Module

The Storage/Control I/O Module performs two functions: to connect outside interfaces to the system controller and to house the hard disk drive. It plugs into the back of the VCO/4K system and provides the I/O interfaces for system peripheral devices and host communication links using four serial ports, one Ethernet port, one printer port and one SCSI connector. Figure 4-1 shows the front panel of the Storage/Control I/O Module.

Physical interfaces to host computers and peripheral devices are provided on the front panel of the Storage/Control I/O Module. Two serial ports are available for SIO host links, and another two are dedicated to supporting the local system administration console and a remote maintenance modem. An Ethernet Transceiver interface and parallel printer connector are also located on the Storage/Control I/O Module.

Specifications

 

Part Number

Contact your Cisco Systems sales representative

 

Interfaces

Four EIA/TIA-232serial ports (master console, remote maintenance modem,

 

 

and two SIO host links)

 

 

 

 

 

 

One Ethernet transceiver interface

 

 

One Centronics-typeparallel interface (system printer)

 

 

One SCSI connector (reserved for future use)

 

Power Requirements:

 

Maximum

Typical

 

Hard Disk Drive

+5 VDC

0.4A

0.33A

 

 

+12 VDC

1.0A

0.17A

 

Ethernet

+5 VDC

0.5A

0.5A

 

 

+12 VDC

0A

0A

 

EIA/TIA-232

+5 VDC

0A

0A

 

 

+12 VDC

0.1A

0.05A

 

 

 

 

Cisco VCO/4K Mechanical Assemblies

 

 

 

 

 

 

 

 

 

78-10334-03

 

 

 

 

4-1

 

 

 

 

 

 

 

Chapter 4 Storage/Control I/O Module

Description

Total Current

+5 VDC

0.9A

0.85A

 

+12 VDC

1.1A

.22A

Total Power

+.5 VDC

7.7 Watts

 

 

+12 VDC

6.89 Watts

 

Operating Temperature

10 to 40°C (50 to 104°F)

 

Relative Humidity

20 to 80% (noncondensing)

 

Physical Dimensions

Height:

14.4 inch (36.6 cm)

 

 

Depth:

5.6 inch (14.2 cm)

 

 

Width:

1.6 inch (4.1 cm)

 

Description

The Storage I/O Module is two card slots wide and slides into the back of the VCO system where it plugs into the control midplane. All outside connections are mounted on the faceplate of the module. All internal connectors are mounted on the board itself for easy access to system internals (for example, SCSI and Ethernet).

The VCO/4K system hard drive is mounted on the upper portion of the I/O Module. The board is built to accommodate a 3.5-inchhard drive. Physical mounting points are provided for the hard drive as well as a50-pinSCSI interface to the system controller. There is also a provision for an external SCSI connection on the front panel. The SCSI connection is reserved for future use.

Front Panel Indicators and Ports Assignments

Figure 4-1 shows the front panel of the Storage/Control I/O Module.

Cisco VCO/4K Mechanical Assemblies

4-2

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

 

 

 

 

 

 

Description

Figure 4-1Storage/Control I/O Module Front Panel

ST /CTRL - I/O

SCSI TRM PWR

 

 

 

ENET PWR

 

 

 

 

 

INTERFACE

 

 

SCSI

 

 

 

ETHERNET

 

 

PRINTER

PORT

 

 

1

 

CONSOLE

 

3

PORT

 

 

4

 

2

PORT

 

PORT

 

 

TTY01

 

 

 

50165

Power is supplied to the Storage/Control I/O Module via the midplane from the Combined Controller card. The hard drive LED signal is brought to the system controller board via the midplane and brought out to the front panel to show hard drive activity. It is located on the Combined Controller in the front of the VCO (see Figure 4-3).

SCSI terminations are provided as an option to be populated on the Storage/Control I/O Module depending on the system configuration. They are currently not being used.

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-3

 

 

 

Chapter 4 Storage/Control I/O Module

Description

The connectors mounted on the front pane are:

:

4 serial ports

DB-25

SCSI port

50-pinmini-SCSIconnector

Ethernet

DB-15

Printer

36-pinCentronics

The connectors mounted on the board are:

SCSI

DIN 64

MODEM

20-pinIDC connector

MODEM power

5-pinheader

The LEDs mounted on the board are:

 

ENET

If illuminated, shows that power is available to the

 

Ethernet

SCSI

If illuminated, shows that there is SCSI termination

 

power

Hard Disk Drive

The hard disk drive is a SCSI-compatibledrive that is used as the system controller’s main data storage facility. The hard disk drive requires +5 volts and +12 volts DC to operate. The hard disk drive is shown inFigure 4-2.The Storage/Control I/O Module supports the hard disk drive LED. The LED is located on the Combined Controller and is visible from the front of the system (seeFigure 4-3).

Cisco VCO/4K Mechanical Assemblies

4-4

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Description

Figure 4-2Location of the Hard Disk Drive on the Storage/Control I/O Module

Hard disk drive

50166

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-5

 

 

 

Chapter 4 Storage/Control I/O Module

Description

Figure 4-3Location of Hard Disk Drive LED on the Combined Controller

CI S COSYSTE MS

R

Hard disk drive LEDs

 

 

 

A

B

ACO

A

B

MAJORMINORAUX

1

AUX

2

 

 

 

 

 

AUTO

 

ACO

 

 

 

 

 

RESET

 

 

 

 

 

 

 

AAC

 

 

 

 

A

B

 

 

 

 

 

 

 

 

 

 

SELECT

ACTIVE

ALARMS

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

INSERT ONLY CARDS DESIGNATED BELOW

 

 

 

 

 

 

 

 

 

 

For Non-Redundantconfiguration use slots1,3-4

 

 

 

 

 

 

 

 

 

 

 

For Redundant configuration use slots 1,2, 3-4,5-6

 

 

 

 

 

 

 

 

 

 

NBC

NBC

COMBINED

COMBINED

 

 

 

 

 

 

 

 

CONNECT ESD

CONTROLLER

CONTROLLER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRIST STRAP HERE

 

 

CPU

CPU

 

 

 

 

 

 

 

 

 

 

 

FAIL

FAIL

 

 

 

 

 

 

 

 

 

 

 

STATUS

STATUS

 

 

 

 

 

 

 

 

 

 

 

RUN

RUN

 

 

 

 

 

 

 

 

 

 

 

SCON

SCON

 

 

 

 

 

 

 

 

 

 

 

RMT RST

RMT RST

 

 

 

 

 

 

 

 

 

 

 

ABORT

ABORT

 

 

 

 

 

 

 

 

 

 

 

RESET

RESET

 

 

 

 

 

 

 

 

 

 

 

MOTOROLA

MOTOROLA

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

RING

 

 

POWER

RING

 

 

 

 

 

 

 

 

GEN.

 

 

 

GEN.

50167

Midplane Connectors

The Storage/Control I/O Module plugs into the midplane through standard DIN 41612 triple-row,96-pinmale connectors.Figure 4-4 shows the control midplane connectors.

Cisco VCO/4K Mechanical Assemblies

4-6

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Description

Figure 4-4Control Midplane

A-sideconnector for the

Storage/Control I/O module

B-sideconnector for the

Storage/Control I/O module

50168

Serial Ports 1 and 2

Serial Port 1/Console and Serial Port 2/TTY01 are dedicated ports for connecting the system master console and remote maintenance modem, respectively. These standard female DB-25ports connect to the console and modem viaEIA/TIA-232cables.Table 4-1 shows the pin and signal assignments for these ports. For additional information on connecting peripheral equipment, refer to theCisco VCO/4K Hardware Installation Guide.

Table 4-1Serial Ports 1 and 2 Pin and Signal Assignments1

Pin

Signal Name

Description/Direction

 

 

 

2

TxD

Transmit Data (terminal to modem)

 

 

 

3

RxD

Receive Data (modem to terminal)

 

 

 

4

RTS

Request to Send (terminal to modem)

 

 

 

5

CTS

Clear to Send (modem to terminal)

 

 

 

6

DSR

Data Set Ready (modem to terminal)

 

 

 

7

GND

Chassis Ground

 

 

 

8

DCD

Data Carrier Detect (modem to terminal)

 

 

 

20

DTR

Data Terminal Ready (terminal to modem)

 

 

 

1. All pins not identified are no-connection.

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-7

 

 

 

Chapter 4 Storage/Control I/O Module

Description

Master console and remote maintenance modem operating parameters (Baud Rate, Stop Bits, Bits per Character and Parity) are defined in the system database via the Peripheral Configuration screen. Wiring for serial port connection to the Master Console is shown in Figure 4-5.Wiring for the remote maintenance modem connection is shown inFigure 4-6.Refer to theCisco VCO/4K System Administrator’s Guide for more information.

Figure 4-5I/O Module to MasterConsole—CableWiring Diagram

Serial Port 1/Console

VT220/320 Console

(DB-25P)

(DB-25S)

Male (3-Conductor,Straight-Thru)Female

Pin 2

 

 

 

TxD

 

Pin 2

 

 

 

 

 

RxD

 

Pin 3

 

 

 

 

Pin 3

 

 

 

 

 

 

GND

Pin 7

 

 

 

 

Pin 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50169

Note You can use a25-conductor,straight-throughcable to connect a master console to the Storage/Control I/O Module. However, only the conductors shown inFigure 4-5 are used.

Figure 4-6I/O Module to Remote MaintenanceModem—CableWiring Diagram

 

Remote Maintenance

Serial Port 2/TTY01

Modem

(DB-25P)

(DB-25P)

Male

 

 

(7-conductor,Straight-thru)

 

 

 

Male

 

 

 

TxD

 

 

 

 

Pin 2

 

 

 

 

Pin 2

Pin 3

 

 

 

RxD

 

 

Pin 3

 

 

 

 

 

 

 

 

CTS

 

 

Pin 5

 

 

 

 

 

Pin 5

 

 

 

 

 

 

 

 

DSR

 

 

Pin

6

 

 

 

 

 

Pin 6

 

 

 

 

 

 

 

GND

 

 

 

Pin

7

 

 

 

 

 

Pin 7

 

 

 

DCD

 

 

Pin 8

 

 

 

 

 

Pin 8

 

 

 

 

 

DTR

 

 

 

Pin 20

 

 

 

Pin 20

 

 

 

 

 

 

50170

Note You must use a9-pinconnector (available from Cisco Systems). A25-pinconnector can be used after the switch box.

Cisco VCO/4K Mechanical Assemblies

4-8

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Description

Serial Ports 3 and 4

Serial Ports 3 and 4 are available for Serial I/O (SIO) links between the system and a host computer. These standard female DB-25ports carry Asynchronous Data Link Control (ADLC) protocol signals between the host and the system overEIA/TIA-232cables. Pin and signal assignments for port 3 is the same as Serial Ports 1 and 2. Refer toTable 4-2 for port 4 pin and signal assignments.

Wiring conventions for physically connecting a host computer to a SIO port are provided in the Cisco VCO/4K Hardware Installation Guide. Jumpers on the Storage/Control I/O Module allow Serial Ports 3 and 4 to be configured as modem (DCE) terminations for connection to a terminal or configured as terminal (DTE) terminations for connection to a modem. Refer to the“Serial Ports 1 Through 4 and Jumper Settings” section on page 4-11 for more information on jumper configurations.

Data communication parameters for each host link must be defined in the system database using the Host Configuration screen following system power-on.Refer to theCisco VCO/4K System Administrator’s Guide for instructions on defining host links.

Table 4-2Serial Ports 3 and 4 Pin and Signal Assignments1

Pin

Signal Name

Description/Direction

 

 

 

2

TxD

Transmit Data (terminal to modem)

 

 

 

3

RxD

Receive Data (modem to terminal)

 

 

 

4

RTS

Request to Send (terminal to modem)

 

 

 

5

CTS

Clear to Send (modem to terminal)

 

 

 

6

DSR

Data Set Ready (modem to terminal)

 

 

 

7

GND

Chassis Ground

 

 

 

8

DCD

Data Carrier Detect (modem to terminal)

 

 

 

15

RTxC

Tx Clock to output data (terminal to modem)

 

 

 

17

RRxC

Rx Clock to input data (terminal to modem)

 

 

 

20

DTR

Data Terminal Ready (terminal to modem)

 

 

 

24

TTxC

Tx Clock to output data (terminal to modem)

 

 

 

1. All pins not identified are no-connection.

Ethernet Interface

The CPU employs a Local Area Network Controller for Ethernet (LANCE) to implement an Ethernet transceiver interface. The balanced transceiver signal lines from the CPU are coupled to an onboard transformer to signal lines that go through the SWI, Outer B/P and control midplane cards, and terminate on the industry-standardDB-15connector on the Storage/Control I/O Module faceplate. Pin and signal assignments for thisDB-15port are listed inTable 4-3.

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-9

 

 

 

Chapter 4 Storage/Control I/O Module

Description

Table 4-3Ethernet Port Pin and Signal Assignments

Pin

Signal

Signal Name

 

 

 

2

C+

Collision + (Input)

 

 

 

3

T+

Transmit + (Output)

 

 

 

5

R+

Receive + (Input)

 

 

 

6

GND

Ground

 

 

 

9

C–

Collision – (Input)

 

 

 

10

T–

Transmit – (Output)

 

 

 

12

R–

Receive – (Input)

 

 

 

To implement Ethernet links, you must purchase the optional Ethernet Communications Package available from Cisco Systems. This package contains supporting software and the Cisco VCO/4K Ethernet Guide which covers the cabling requirements and implementation strategies. You must provide cables, transceivers and other components to establish Ethernet links.

Printer Interface

The printer interface on the Storage/Control I/O Module front panel supports parallel system printers through a 36-pinCentronics-typeconnector.Figure 4-7 shows the cable wiring diagrams for connecting the Storage/Control I/O Module parallel port to the system printer.

Note The End of Line (EOL) terminator for the system printer must be defined in the system database via the Peripheral Configuration screen prior to use (refer to theCisco VCO/4K System Administrator’s Guide for more information).

Figure 4-7I/O Module to SystemPrinter—CableWiring Diagram

 

Printer

 

Parallel Printer

(36-pinCentronics)

 

 

(36-pin)

 

Male

(29-conductor,Straight-thru)

 

 

 

Male

 

 

 

 

 

 

 

 

 

 

 

Pin 1

 

 

 

 

 

Pin 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 13

 

 

 

 

 

Pin 13

 

GND

 

 

Pin 16

 

 

 

 

 

Pin 16

 

 

 

 

 

 

 

Pin 19

 

 

 

 

 

Pin 19

 

 

 

 

Pin 32

Pin 32

50171

Cisco VCO/4K Mechanical Assemblies

4-10

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Hardware Configuration

Note You can use a36-conductor,straight-throughparallel cable to connect a printer to the system controller. However, only the conductors shown inFigure 4-7areused. For more information on the parallel36-pinCentronics cable available from Cisco Systems, refer to theCisco VCO/4K Hardware Planning Guide.

SCSI Interface

The SCSI mass storage bus interface on the Storage/Control I/O Module is not used in system operation.

Hardware Configuration

This section outlines hardware configuration options.

SCSI Termination Configuration

The SCSI Interface connector is reserved for future use.

Serial Port Configuration

Serial Ports 1 Through 4 and Jumper Settings

Serial ports 1 through 4 on the Storage/Control I/O Module can be configured as modem (DCE) terminations for connection to a terminal or configured as terminal (DTE) terminations for connection to a modem. (Refer to the “Serial Ports 1 Through 4” section on page 4-12 for more information.)

Jumpers are positioned in J1 for Serial Port 1 (master console), JP17 for Serial Port 2 (remote maintenance modem, and JP13 and JP18 for Serial Ports 3 and 4 (SIO host links), respectively.

For Serial Ports 1 and 2, these jumper settings assume that straight-throughEIA (DCE to DTE) cables are used to connect the system to the master console and remote maintenance modem. If the jumpers are moved to position JP11 (for the master console) and JP16 (for the remote modem), crossover cables can be used.

Note Straight-throughcables directly link the connector pinouts fromend-to-end.In crossover cables, Pins 2 and 3 are crosswired; Pin 2 at one end is wired to Pin 3 at the opposite end, and vice versa.

Jumper settings for Serial Ports 3 and 4 (SIO host links) are determined by two factors: the type of cable employed (straight-throughor crossover) and the host termination at the end of the cable (terminal or modem).

The default jumper settings for Serial Ports 3 and 4 configure the CPU as a DTE termination. This configuration supports the following arrangements:

Straight-throughcables connecting the system to a modem (DTE to DCE)

Crossover (null modem) cables connecting the system to a terminal (DTE to DTE)

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-11

 

 

 

Chapter 4 Storage/Control I/O Module

Hardware Configuration

You can position the jumpers in locations JP13 and JP18 (under the “To Terminal” etching) to configure the CPU as a DCE termination. Moving the jumpers to these locations supports the following SIO connections:

Straight-throughcables connecting the system to a host terminal (DCE to DTE)

Crossover (null modem) cables connecting the system to a modem (DCE to DCE)

Refer to the Cisco VCO/4K Hardware Installation Guide for more information on serial cable requirements.

Note When modifying jumper positions on Storage/Control I/O Module boards, you must move all seven jumpers to the new location to ensure operation.

Serial Ports 1 Through 4

Serial ports 1 through 4 can be configured as a modem (DCE) for connection to a terminal, or terminal (DTE) for connection to a modem. The Storage/Control I/O Module card’s serial ports are configured for shipment in the DCE configuration. Table 4-4 illustrates jumper positions for DCE and DTE.

Table 4-4Jumper Positions for DCE and DTE Modem Connections

Port

DTE Operation

DCE Operation

 

 

 

1

Jumper –TOMODEM JP11

Jumper—JP1TO TERMINAL

 

 

 

2

Jumper – TO MODEM JP17

Jumper—JP16TO TERMINAL

 

 

 

3

Jumper – TO MODEM JP14

Jumper—JP13TO TERMINAL

 

 

 

4

Jumper – TO MODEM JP19

Jumper—JP18TO TERMINAL

 

 

 

Refer to Figure 4-8 for the jumper locations on the Storage/Control I/O Module card.

Figure 4-8Jumper Locations on the Storage/Control I/O Module Card

TO MODEM

 

TO MODEM

TO MODEM

TO MODEM

JP19

 

JP17

JP14

JP11

PORT 4

 

PORT 2

PORT 3

PORT 1

JP18

 

JP16

JP13

JP1

TO TERMINAL

TO TERMINAL

 

Hard disk drive

TO TERMINAL

TO TERMINAL

JP15

J21

 

 

 

 

J20

 

 

 

 

 

 

50172

Seven jumpers are installed at jumper locations JP1, JP11, JP13, JP14, JP16, JP17, JP18 and JP19,

connecting pins 1-2,3-4,5-6,7-8,9-10,11-12,13-14as shown inFigure 4-9.

Cisco VCO/4K Mechanical Assemblies

4-12

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Removal and Replacement Information

Figure 4-9Jumper Configuration for DCE/DTE, Serial Ports1-4

pins

2

4

6

8

10

12

14

50173

pins

1

3

5

7

9

11

13

Serial port 4 can be configured to use clock signals by the TRXC4 and RTXC4 signal lines. Jumper JP15 configurations of the clock lines are shown in Figure 4-10. The module is shipped without clock lines connected.

Figure 4-10Jumper 15 Configuration of Clock Lines, Serial Port 4

JP15

1

3

5

7

9

11

connects TRXC4 to Port 4 Pin 15connects TRXC4 to Port 4 Pin 17

connects TRXC4 to Port 4 Pin 24

connects RTXC4 to Port 4 Pin 24

connects RTXC4 to Port 4 Pin 17

connects RTXC4 to Port 4 Pin 15

50174

Removal and Replacement Information

Figure 4-11 shows the location of the Storage/Control I/O Module cards in the rear of the VCO system. The card is located in slots 3 to 4 in nonredundant systems, and in slots 3 to 4 and 5 to 6 in redundant systems. The label at the base of the card cage identifies where the card(s) is located.

There is a soft start circuit on the card which allows for the Storage/Control I/O Module to be removed and replaced while the system is running. This should only be done when the system contains redundant Storage/Control I/O Modules, and when the module to be removed is in standby mode.

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-13

 

 

 

Removal and Replacement Information

Figure 4-11Storage/Control I/O Module Location

Fan Unit

Slot 21

Alarm

Connector

A/B Switch

Connector

REMOTE

ALARMS

REMOTE

SWITCH A/B

FAN ALARM

PORT 8

PORT 8

PORT 7

PORT 7

PORT 6

PORT 6

PORT 5

PORT 5

PORT 4

PORT 4

PORT 3

PORT 3

PORT 2

PORT 2

PORT 1

PORT 1

 

 

 

 

 

 

 

 

 

 

 

 

Chapter 4 Storage/Control I/O Module

 

 

 

 

 

 

 

 

 

 

 

 

Slot 1

 

 

 

 

ST /CTRL - I/O

ST /CTRL - I/O

 

 

 

 

 

SCSI

 

 

SCSI

 

NBC

NBC

 

 

 

 

TRIM

 

 

TRIM

 

CLK

CLK

 

 

 

 

PWR

 

 

PWR

 

I/O

I/O

 

 

 

 

ENET

 

ENET

 

 

 

 

 

 

 

PWR

 

 

PWR

 

 

 

 

 

 

 

 

INTERFACE

 

INTERFACE

 

 

 

 

 

 

SCSI

 

 

 

SCSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage/Control

 

 

 

 

 

 

ETHERNET

 

 

ETHERNET

I/O Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRINTER

 

 

PRINTER

 

 

 

 

 

PORT

 

 

1

PORT

 

 

1

 

 

 

 

 

 

CONSOLE

 

CONSOLE

 

 

 

 

 

 

3

PORT

 

 

3

PORT

 

 

 

 

 

 

 

 

 

 

 

 

 

EXT

EXT

 

 

 

 

 

 

 

 

 

 

 

CLK

CLK

 

 

 

 

PORT

4

PORT

2

PORT

4

PORT

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TTY01

 

 

TTY01

 

DC

MODEL: VCO SERIES /20

P/N: S/N: ELECTRICAL RATING:

-40/-60V30/20A

31043300100

 

 

 

 

 

 

 

 

SYS T E M S

 

 

 

 

 

 

 

 

 

 

 

 

CI S CO

 

 

 

 

 

 

 

 

 

 

 

50175

 

 

 

 

 

 

 

 

 

 

 

 

Power Switch

PEM

Cisco VCO/4K Mechanical Assemblies

4-14

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Removal and Replacement Information

Removal Procedures

Caution Follow ESD rules when removing a system component. Use a wrist strap for grounding.

To remove a Storage/Control I/O Module in a nonredundant system, do the following.

Caution In a nonredundant system, power down the system before removing the card.

Step 1 Remove the Combined Controller that is connected to the Storage/Control I/O Module to be serviced. Refer to theCisco VCO/4K Card Technical Descriptions for information on how to remove the Combined Controller.

Step 2 Use a1/8-inchbladed screwdriver to loosen the captive mounting screws at the top and bottom of card. Do not remove the screws from the cards.

Step 3 Grasp the screws at the top and bottom of the card and pull the card away from the midplane.

The card fits tightly into the midplane connectors and some force is required to pull it away from the midplane. However, do not exert excessive force on the card to remove it.

Step 4 When the card is free of the connector, grasp the sides of the front panel and pull the card free of the card slot.

Step 5 Grasp the card on its bottom edge as it is removed from the card rack.

Step 6 When you have removed the card from the slot, place it on an antistatic mat or in an antistatic envelope.

Note Do not replace the Combined Controller until the Storage/Control I/O Module is replaced. If the Storage/Control I/O Module is not replaced at the time of removal, do not replace the Combined Controller.

To remove and replace a Storage/Control I/O Module card in a redundant system:

Step 1 If servicing an active Storage/Control I/O Module, switch the active side to standby. Refer to the maintenance chapter in theCisco VCO/4K System Administrator’s Guide for information about how to switch the active side to standby.

Step 2 When the transition to standby is complete, remove and replace the Storage/Control I/O Module.

If you are permanently removing the Storage/Control I/O Module from a nonredundant system, back up the database before powering down the system and removing the module. Refer to the Cisco VCO/4K System Administrator’s Guide for information on backing up the database.

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-15

 

 

 

Chapter 4 Storage/Control I/O Module

Troubleshooting

Replacement Procedures

Caution Follow ESD rules when removing a system component. Use a wrist strap for grounding.

To replace the Storage/Control I/O Module:

Step 1 Place the replacement Storage/Control I/O Module on the antistatic mat or envelope.

Step 2 Verify that the Combined Controller that is to be connected to the Storage/Control I/O Module isnot plugged into the backplane.

Step 3 Verify that all the jumpers on the replacement card correspond with those on the removed Storage/Control I/O Module.

Verify that the jumper configuration is appropriate for the system configuration.

Refer to the “Serial Ports 1 Through 4 and Jumper Settings” section on page 4-11 for details on jumper settings for the Storage/Control I/O Module.

Step 4 Grasp the replacement card by the sides of the front panel and align it with the top and bottom card guides.

Step 5 Push the card inward until it makes contact with the midplane.

Step 6 Firmly push the card toward the midplane. The card fits tightly into the midplane connectors and some force is required to seat the card back firmly into the midplane connectors.

Step 7 Use a1/8-inchbladed screwdriver to tighten the mounting screws at the top and bottom of each card into the tapped holes on the mounting rail.

Step 8 Plug the Combined Controller into the backplane.

Step 9 If installing in a nonredundant system, make sure the system is powered on.

Step 10 If the hard disk drive does not contain the Generic software, install the software. Refer to the system release notes for instructions on installing the Generic software, backing up and restoring the database, and licensing.

Troubleshooting

Note More extensive troubleshooting information is contained in theCisco VCO/4K

Troubleshooting Guide.

LEDs Not Illuminated

If either of the LEDs on the Storage/Control I/O Module is not illuminated, corrective action should be taken. These LEDs are fused powered sources. The fuses are on the Combined Controller and are not field replaceable. Call Cisco Systems for technical support.

Cisco VCO/4K Mechanical Assemblies

4-16

78-10334-03

 

 

Chapter 4 Storage/Control I/O Module

Troubleshooting

Note The ENET PWR LED should be illuminated only when Ethernet is being used. If the ENET PWR LED is not illuminated and Ethernet is being used, contact Cisco Systems Technical Support.

Troubleshooting Reference Materials

For detailed information covering all troubleshooting areas, refer to the Cisco VCO/4K Troubleshooting Manual.

The Cisco VCO/4K System Maintenance Manual describes corrective maintenance procedures for host communications links. In addition to this manual, refer to theCisco VCO/4K Ethernet Guide, and the

Cisco VCO/4K Standard Programming Reference and Cisco VCO/4K Extended Programming Referencefor details relating to communication protocols and command/report formats. Cisco VCO/4K System Messagesdescribes the network messages associated with problems detected with the host communications links.

Additional reference materials include the OEM manuals provided with any other peripheral devices connected to the Storage/Control I/O Module. This includes the printer and the serial terminal.

Cisco VCO/4K Mechanical Assemblies

 

78-10334-03

4-17

 

 

 

Chapter 4 Storage/Control I/O Module

Troubleshooting

Cisco VCO/4K Mechanical Assemblies

4-18

78-10334-03