Cisco Systems UCS C220 M3 User Manual

Size:
2.85 Mb
Download

Cisco UCS C220 M3

High-DensityRack Server

(Small Form Factor Disk

Drive Model)

CISCOSYSTEMS

PUBLICATIONHISTORY

170 WESTTASMANDR

 

SAN JOSE, CA, 95134

REV A.16 OCTOBER 9, 2012

WWW.CISCO.COM

 

CONTENTS

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6

CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

STEP

1

VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

STEP

2

SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

STEP

3

SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

STEP

4

SELECT RAID CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

STEP

5

SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . .

22

STEP

6

SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24

STEP

7

ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . .

26

STEP

8

ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

STEP

9

SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30

STEP

10

ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . .

33

STEP

11

ORDER A TRUSTED PLATFORM MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

34

STEP

12

ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . .

35

STEP

13

ORDER OPTIONAL USB 2.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

STEP

14

SELECT OPERATING SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

STEP

15

SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39

STEP

16

SELECT OPTIONAL VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . .

40

STEP

17

SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

41

OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Recommended Memory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Supported DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Low-Voltage DIMM Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

RAID Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Motherboard USB and SD Ports, and RAID Card Backup Location . . . . . . . . . . . . . . . . . . . . 59

TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

2

OVERVIEW

OVERVIEW

The Cisco® UCS C220 M3 rack server is designed for performance and density over a wide range of business workloads from web serving to distributed database.

Building on the success of the Cisco UCS C200 M2 rack server, the enterprise-classUCS C220 M3 server further extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel®E5-2600series product family CPUs that deliver significant performance and efficiency gains. In addition, the UCS C220 M3 server provides 16 DIMM slots, up to 8 drives and 2 x 1 GbELAN-on-motheroard(LOM) ports delivering outstanding levels of density and performance in a compact package.

Figure 1 Cisco UCS C220 M3 High-DensitySFF Rack Server

Front View

Rear View

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

3

DETAILED VIEWS

DETAILED VIEWS

Chassis Front View

Figure 2 shows the Cisco UCS C220 M3High-DensitySFF Rack Server.

Figure 2 Chassis Front View

 

 

 

4

6

8

 

 

 

1

2

3

5

7

 

 

 

 

 

 

 

 

HDD1

HDD2

HDD3

331682

HDD4

 

 

HDD5

HDD6

HDD7

HDD8

 

 

 

 

 

 

 

 

 

 

 

9

 

10

 

 

 

1

Power button/power status LED

6

Power supply status LED

 

 

 

 

2

Identification button/LED

7

Network link activity LED

 

 

 

 

3

System status LED

8

Asset tag (serial number)

 

 

 

 

4

Fan status LED

9

KVM connector (used with KVM cable that

 

 

 

provides two USB, one VGA, and one serial

 

 

 

connector)

 

 

 

 

5

Temperature status LED

10

Drives (up to eight hot-swappable2-5-inch

 

 

 

drives)

 

 

 

 

For more information about the KVM cable connection, see KVM CABLE, page 58.

4

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

DETAILED VIEWS

Chassis Rear View

Figure 3 shows the external features of the rear panel.

Figure 3 Chassis Rear View

1

2

3

PSU1

PCIe2

PCIe1

PSU2

331683

 

 

 

 

4

5

6

7

8

9

 

 

 

 

1

Power supplies (up to two)

6

One 10/100/1000 Ethernet dedicated

 

 

 

management port

 

 

 

 

 

 

 

 

 

2

Slot 2: Low-profilePCIe slot on riser:

7

Dual 1-GbEthernet ports

 

 

 

(half-height,half-length,x16 connector, x8

 

(LAN1 and LAN2)

 

 

 

 

lane width)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Slot 1: Standard-profilePCIe slot on riser:

8

USB ports

 

 

 

 

 

(full-height,half-length,x24 connector, x16

 

 

 

 

 

 

 

lane width)

 

 

 

 

 

 

 

 

 

 

 

4

VGA video connector

9

Rear Identification button/LED

 

 

 

 

 

 

 

 

 

5

Serial port (RJ-45connector)

-

-

 

 

 

 

 

 

 

 

 

 

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

5

BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided inCONFIGURING the SERVER, page 9.

Table 1 Capabilities and Features

Capability/Feature

Description

 

 

Chassis

One rack unit (1RU) chassis

CPU

One or two Intel® E5-2600series processor family CPUs

Chipset

Intel® C600 series chipset

Memory

16 slots for registered ECC DIMMs (RDIMMs) and load-reducedDIMMs

 

(LRDIMMs)

NIC

Embedded dual-portIntel i350PCIe-basedGigabit Ethernet controller,

 

supporting the following:

 

Pre-ExecutionBoot (PXE boot)

 

iSCSI boot

Expansion slots

Two PCIe slots (on a riser card)

 

Onefull-heightprofile,half-lengthslot with x24 connector and x16 lane

 

Onehalf-heightprofile,half-lengthslot with x16 connector and x8 lane

Internal storage devices

Drives are installed into front-paneldrive bays that providehot-pluggable

 

access.

 

Small Form Factor (SFF) drives. Up to eight2.5-inchSAS or SATA

 

hot-swappablehard disk drives (HDDs) or solid state drives (SSDs)

 

The server also contains one internal USB 2.0 port on the motherboard

 

that you can use with a USB thumb drive for additional storage

Cisco Flexible Flash

The server supports one internal Cisco Flexible Flash drive (SD card).

drives

The SD card ispre-loadedwith four virtual drives. The four virtual drives

 

 

contain, respectively, the Cisco Server Configuration Utility, the Cisco

 

Host Upgrade Utility, the Cisco C-Seriesserver drivers set, and a blank

 

virtual drive on which you can install an OS or a hypervisor

 

4 GB is available for general use

Video

The Emulex Pilot 3 Integrated Baseboard Management Controller provides

 

video:

 

Matrox G200e video controller

 

Integrated 2D graphics core with hardware acceleration

 

Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at

 

60 Hz

 

24-bitcolor depth for all resolutions less than 1600x1200

 

Up to 256 MB video memory

 

 

6

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

BASE SERVER STANDARD CAPABILITIES and FEATURES

Capability/Feature

Description

 

 

Storage controller

Embedded RAID (3 Gbs)

 

• Embedded SATA-onlyRAID controller, supporting up to 4SATA-only

 

drives (RAID 0, 1, 10)

 

• ROM5 embedded RAID upgrade, supporting up to 8 SAS/SATA drives

 

(RAID 0, 1, 10). SAS and SATA drives can be mixed.

 

• ROM55 embedded RAID upgrade, supporting up to 8 SAS/SATA drives

 

(RAID 0, 1, 10, 5). SAS and SATA drives can be mixed.

 

2008M-8iMezzanine Cards (6 Gbs) - two versions

 

• Cisco UCSC RAID SAS 2008M-8iMezzanine Card, supporting up to 8

 

SAS/SATA drives supporting RAID 0, 1, 10, 5, and 50. SAS and SATA

 

drives can be mixed. This card has a product ID (PID) of

 

UCSC-RAID-11-C220.

 

• Cisco UCSC RAID SAS 2008M-8iMezzanine Card, supporting up to

 

eight SAS/SATA drives supporting RAID 0, 1, and 10. SAS and SATA

 

drives can be mixed. This card has a product ID (PID) of

 

UCSC-RAID-MZ-220.

 

Plug-inPCIe Cards (6 Gbs)

 

• LSI MegaRAID SAS 9266-8i8-portplug-inPCIe RAID RAID controller

 

card (occupies a half-heightPCIe slot), supporting RAID levels 0, 1,

 

10, 5, 6, 50, 60 and up to 8 internal SAS or SATA drives. SAS and SATA

 

drives can be mixed.

 

• LSI MegaRAID SAS 9266CV-8iRAID8-portPCIeplug-inRAID controller

 

card, supporting RAID 0, 1, 10, 5, 6, 50, and 60 and up to eight

 

internal SAS or SATA drives. SAS and SATA drives can be mixed.

Interfaces

Rear panel

 

• One RJ45 serial port connector

 

• Two USB 2.0 port connectors

 

• One DB15 VGA connector

 

• Two RJ-4510/100/1000 Ethernet port connectors

 

• One RJ-4510/100/1000 Ethernet management port, using Cisco

 

Integrated Management Controller (CIMC) firmware

 

Various PCIe card ports (dependent on which cards are installed)

 

• Converged Network Adapter (CNA) ports

 

• Network Interface Card (NIC) ports

 

• Host Bus Adapter (HBA) ports

 

Front panel

 

• One KVM console connector (supplies two USB, one VGA, and one

 

serial connector)

Front Panel

A front panel controller provides status indications and control buttons

Power subsystem

Up to two 450 W 650 W power supplies. One is mandatory; one more can be

 

added for 1 + 1 redundancy.

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

7

BASE SERVER STANDARD CAPABILITIES and FEATURES

Capability/Feature Description

Fans

Integrated management processor

Chassis:

Five hot-swappablefans forfront-to-rearcooling Power supply:

Each power supply is equipped with a fan.

Cisco Integrated Management Controller (CIMC) firmware.

Depending on your CIMC settings, the CIMC can be accessed through the 1-GbEthernet dedicated management port, the1-GbEthernet LOM ports, or a Cisco P81E or Cisco 1225 virtual interface card (VIC).

8

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

CONFIGURING the SERVER

Follow these steps to configure the Cisco UCS C220 M3 High-DensitySFF Rack Server:

STEP 1 VERIFY SERVER SKU, page 10

STEP 2 SELECT CPU(s), page 11

STEP 3 SELECT MEMORY, page 13

STEP 4 SELECT RAID CONFIGURATION, page 18

STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 22

STEP 6 SELECT PCIe OPTION CARD(s), page 24

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 26

STEP 8 ORDER POWER SUPPLY, page 29

STEP 9 SELECT AC POWER CORD(s), page 30

STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 33

STEP 11 ORDER A TRUSTED PLATFORM MODULE, page 34

STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 35

STEP 13 ORDER OPTIONAL USB 2.0 DRIVE, page 36

STEP 14 SELECT OPERATING SYSTEM, page 37

STEP 15 SELECT OPERATING SYSTEM MEDIA KIT, page 39

STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE, page 40

STEP 17 SELECT SERVICE and SUPPORT LEVEL, page 41

OPTIONAL STEP - ORDER RACK(s), page 45

OPTIONAL STEP - ORDER PDU, page 46

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

9

CONFIGURING the SERVER

STEP 1 VERIFY SERVER SKU

Verify the product ID (PID) of the server as shown in Table 2.

Table 2 PID of the C220 M3 High-DensitySFF Rack Base Server

Product ID (PID)

Description

 

 

UCSC-C220-M3S

UCS C220 M3 SFF, no CPU, memory, HDD, SDD, power supply, SD card, or PCIe

 

cards, with 1 rail kit

 

 

The Cisco C220 M3 server:

Includes one tool-lessrail kit

Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-statedrives (SSDs), SD card, orplug-inPCIe cards.

NOTE: Use the steps on the following pages to configure the server with the components that you want to include.

10

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 2 SELECT CPU(s)

The standard CPU features are:

Intel E5-2600series processor family CPUs

Intel C600 series chipset

Cache size of 10, 15, or 20 MB

Select CPUs

The available CPUs are listed in Table 3.

Table 3 Available Intel CPUs: E5-2600Series Processor Family CPUs

 

Intel

Clock

Power

Cache

 

 

Highest DDR3

Product ID (PID)

Freq

Size

Cores

QPI

DIMM Clock

Number

(W)

 

(GHz)

(MB)

 

 

Support (MHz)1

 

 

 

 

 

UCS-CPU-E5-2690

E5-2690

2.90

135

20

8

8 GT/s

1600

UCS-CPU-E5-2680

E5-2680

2.70

130

20

8

8 GT/s

1600

UCS-CPU-E5-2667

E5-2667

2.90

130

15

6

8 GT/s

1600

UCS-CPU-E5-2665

E5-2665

2.40

115

20

8

8 GT/s

1600

UCS-CPU-E5-2660

E5-2660

2.20

95

20

8

8 GT/s

1600

UCS-CPU-E5-2650

E5-2650

2.00

95

20

8

8 GT/s

1600

UCS-CPU-E5-2650L

E5-2650L

1.80

70

20

8

8 GT/s

1600

UCS-CPU-E5-2643

E5-2643

3.30

130

10

4

8 GT/s

1600

UCS-CPU-E5-2640

E5-2640

2.50

95

15

6

7.2 GT/s

1333

UCS-CPU-E5-2630

E5-2630

2.30

95

15

6

7.2 GT/s

1333

UCS-CPU-E5-2630L

E5-2630L

2.00

60

15

6

7.2 GT/s

1333

UCS-CPU-E5-2620

E5-2620

2.00

95

15

6

7.2 GT/s

1333

UCS-CPU-E5-2609

E5-2609

2.40

80

10

4

6.4 GT/s

1066

Notes . . .

1.If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

11

CONFIGURING the SERVER

Approved Configurations

(1)1-CPUconfigurations:

Select any one CPU listed in Table 3.

(2)2-CPUConfigurations:

Select two identical CPUs from any one of the rows of Table 3 on page 11.

Caveats

You can select either one processor or two identical processors.

For optimal performance, select DIMMs with the highest clock speed for a given processor (see Table 3 on page 11). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.

12

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 3 SELECT MEMORY

The standard memory features are:

DIMMs

Clock speed: 1333 or 1600 MHz

Ranks per DIMM: 1, 2, or 4

Operational voltage: dual voltage capable (1.5 V or 1.35 V)

Registered ECC DDR3 DIMMS (RDIMMS) or load-reducedDIMMS (LRDIMMs)

Memory is organized with four memory channels per CPU, with up to two DIMMs per channel, as shown in Figure 4.

Figure 4 C220 M3 SFF Memory Organization

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

13

CONFIGURING the SERVER

Select DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 4.

NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.

Table 4 Available DDR3 DIMMs

Product ID (PID)

PID Description

Voltage

Ranks/

DIMM

 

 

 

 

 

 

 

DIMM Options

 

 

 

 

 

 

 

UCS-ML-1X324RY-A

32GB DDR3-1600-MHzLRDIMM/PC3-12800/quadrank/x4/1.35v

1.35 V

4

UCS-MR-1X162RY-A

16GB DDR3-1600-MHzRDIMM/PC3-12800/dualrank/x4/1.35v

1.35 V

2

UCS-MR-1X162RX-A

16GB DDR3-1333-MHzRDIMM/PC3-10600/dualrank/x4/1.35v

1.35 V

2

UCS-MR-1X082RY-A

8GB DDR3-1600-MHzRDIMM/PC3-12800/dualrank/x4/1.35v

1.35 V

2

UCS-MR-1X082RX-A

8GB DDR3-1333-MHzRDIMM/PC3-10600/dualrank/x4/1.35v

1.35 V

2

UCS-MR-1X041RY-A

4GB DDR3-1600-MHzRDIMM/PC3-12800/singlerank/x4/1.35v

1.35 V

1

UCS-MR-1X041RX-A

4GB DDR3-1333-MHzRDIMM/PC3-10600/singlerank/x4/1.35v

1.35 V

1

 

 

 

Memory Mirroring Option

 

 

N01-MMIRROR

Memory mirroring option

 

 

 

 

 

 

14

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Approved Configurations

(1)1-CPUconfiguration without memory mirroring:

Select from 1 to 8 DIMMs. Refer to Memory Population Rules, page 50, for more detailed information.

(2)1-CPUconfiguration with memory mirroring:

Select 2, 4, 6, or 8 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table.

Total

CPU 1 DIMM Placement in Channels

Number

 

(for identical DIMMs)

of

Blue Slots

 

Black Slots

DIMMs

 

 

 

 

 

2

(A1, B1)

 

 

4

(A1,B1); (C1,D1)

 

 

6

(A1,B1); (C1,D1)

 

(A2,B2)

8

(A1,B1); (C1,D1)

 

(A2,B2); (C2,D2)

 

 

 

 

Select the memory mirroring option (N01-MMIRROR)as shown inTable 4 on page 14.

(3)2-CPUconfiguration without memory mirroring:

Select from 1 to 8 DIMMs per CPU. Refer to Memory Population Rules, page 50, for more detailed information.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

15

CONFIGURING the SERVER

(4)2-CPUconfiguration with memory mirroring:

Select 2, 4, 6, or 8 identical DIMMs per CPU. The DIMMs will be placed by the factory as shown in the following table.

Number

CPU 1 DIMM Placement in Channels

CPU 2 DIMM Placement in Channels

of

(for identical dual-rank DIMMs)

(for identical dual-rank DIMMs)

DIMMs

 

 

 

 

Blue Slots

Black Slots

Blue Slots

Black Slots

per CPU

 

 

 

 

 

2

(A1, B1)

 

(E1, F1)

 

4

(A1,B1); (C1,D1)

 

(E1,F1); (G1,H1)

 

6

(A1,B1); (C1,D1)

(A2,B2)

(E1,F1); (G1,H1)

(E2,F2)

8

(A1,B1); (C1,D1)

(A2,B2); (C2,D2)

(E1,F1); (G1,H1)

(E2,F2); (G2,H2)

 

 

 

 

 

Select the memory mirroring option (N01-MMIRROR)as shown inTable 4 on page 14.

NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs.

16

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Caveats

The server supports registered DIMMs (RDIMMs) or load-reducedDIMMS (LRDIMMs), however, do not mix RDIMMs and LRDIMMs in a server.

When using mirroring, DIMMs must be installed in identical pairs across paired DDR3 buses. That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B and in C and D can be different.

UDIMMs and non-ECCDIMMs are not supported.

Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring).

When singleand dual-rankDIMMs are populated for 2DPC, always populate the dual rank DIMM in the blue DIMM slot, and thesingle-rankDIMM in the black DIMM slot (only the 4GB DIMMs aresingle-rank).

By default, all DIMMs run at 1.35 V, which yields 1333-MHzmemory speeds. To run the memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM (service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields1600-MHzspeeds, provided:

The DIMMs are 1600-MHzdevices

The CPUs chosen support 1600-MHzoperation.

For more information regarding memory, see CPUs and DIMMs, page 48.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

17

CONFIGURING the SERVER

STEP 4 SELECT RAID CONFIGURATION

The RAID controller choices are:

Embedded RAID (on motherboard)

NOTE: If you do not select a mezzanine card, aplug-inPCIe RAID card, or one of the embedded RAID upgrade options, you will have an embeddedSATA-onlyRAID controller that supports up to fourSATA-onlydrives (RAID 0, 1, 10)

Mezzanine RAID controller cards

Plug-inPCIe RAID controller cards

Cisco can provide factory-configuredRAID systems depending on the RAID controller chosen and the number of drives ordered.Factory-configuredRAID options are listed with each RAID card description.

NOTE: The number of RAID groups (logical drives/ virtual drives) supported per controller is as follows:

Embedded RAID = 8 drives

Cisco UCSC RAID SAS 2008M-8iMezzanine Card = 16 drives

LSI MegaRAID SAS 9266-8iRAID controller card = 64 drives

Select RAID Options

Select as follows:

One embedded RAID upgrade option (see Table 5), or

One mezzanine RAID controller (see Table 6), or

One PCIe RAID controller card (see Table 7 on page 19)

Table 5 Available Embedded RAID Options

Product ID (PID)

PID Description

 

 

RAID Controllers

 

UCSC-RAID-ROM5

Onboard RAID, supporting up to 8 SAS or SATA drives. SAS and SATA drives can

 

be mixed. This option supports RAID 0, 1, and 10, and operates at 3 Gb/s.

 

Operating systems supported are Windows and Linux only (no VMware

 

support).

UCSC-RAID-ROM55

Onboard RAID, supporting up to 8 SAS or SATA drives. SAS and SATA drives can

 

be mixed. This option supports RAID 0, 1, 10, and 5, and operates at 3 Gb/s.

 

Operating systems supported are Windows and Linux only (no VMware

 

support).

 

 

18

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 6 Available Mezzanine Card RAID Options

Product ID (PID)

PID Description

 

 

RAID Controllers

UCSC-RAID-11-C220Cisco UCSC RAID SAS2008M-8iMezzanine Card (RAID 0, 1, 10, 5, and 50 supported), operating at 6 Gbs.

Supports up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed.

Factory-configuredRAID options available: RAID 0, 1, 10, and 5 (see the RAID PIDs section in this table)

No data cache backup

UCSC-RAID-MZ-220Cisco UCSC RAID SAS2008M-8iMezzanine Card (RAID 0, 1, 10 supported), operating at 6 Gbs.

Supports up to eight internal SAS or SATA drives. SAS and SATA drives can be mixed.

Factory-configuredRAID options available: RAID 0, 1, and 10 (see the RAID PIDs section in this table)

No data cache backup

Table 7 Available Plug-InPCIe Card RAID Options

Product ID (PID)

PID Description

 

 

RAID Controllers

 

UCS-RAID-9266NB

LSI MegaRAID SAS 9266-8iRAID controller card with no data cache backup

 

(RAID 0, 1, 10, 5, 6, 50, and 60 supported), operating at 6 Gbs.

 

Supports up to eight internal SAS and/or SATA drives. SAS and SATA drives

 

can be mixed.

 

Includes 1 GB of write cache

 

Factory-configuredRAID options available: RAID 0, 1, 10, 5, and 6 (see the

 

RAID PIDs section in this table)

UCS-RAID-9266CV

LSI MegaRAID SAS 9266CV-8iRAID controller card with data cache backup (RAID

 

0, 1, 10, 5, 6, 50, 60), operating at 6 Gbs.

 

Supports up to eight internal SAS or SATA drives. SAS and SATA drives can

 

be mixed.

 

Includes a 1 GB Transportable Memory Module (TMM) and SuperCap power

 

module for data cache backup

 

Factory-configuredRAID options available: RAID 0, 1, 10, 5, and 6 (see the

 

RAID PIDs section in this table)

 

 

Super Capacitor Option

 

 

 

UCS-RAID-CV-SC=

LSI CacheVault Power Module for SAS 9266CV

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

19

CONFIGURING the SERVER

Table 7 Available Plug-InPCIe Card RAID Options(continued)

Product ID (PID)

PID Description

 

 

 

RAID Configuration Options

R2XX-RAID0

Factory preconfigured RAID striping option

 

 

Enable RAID 0 Setting. Requires a minimum of one hard drive.

R2XX-RAID1

Factory preconfigured RAID mirroring option

 

 

Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,

 

 

capacity.

R2XX-RAID5

Factory preconfigured RAID option

 

 

Enable RAID 5 Setting. Requires a minimum of three drives of the same size,

 

 

speed, capacity.

R2XX-RAID6

Factory preconfigured RAID option

 

 

Enable RAID 6 Setting. Requires a minimum of four drives of the same size,

 

 

speed, capacity.

R2XX-RAID10

Factory preconfigured RAID option

 

 

Enable RAID 10 Setting. Requires a even number of drives (minimum of four

 

 

drives) of the same size, speed, capacity.

 

 

 

 

 

 

 

 

NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown inTable 5

NOTE: No RAID option can be chosen if you have no drives

20

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Approved Configurations

(1)1-CPUConfigurations

Mezzanine cards are not supported for 1-CPUconfigurations, Therefore, only the following RAID controllers are supported forsingle-CPUconfigurations:

Embedded RAID

LSI MegaRAID SAS 9266-8i

LSI MegaRAID SAS 9266CV-8i

(2)2-CPUConfigurations

Select an embedded RAID option from Table 5, one mezzanine RAID controller fromTable 6 on page 19, or one PCIe RAID controller fromTable 7 on page 19. You may also select an appropriate optional RAID configuration listed inTable 7 on page 19.

Caveats

The mezzanine controller is not available for 1-CPUconfigurations.

If you choose a mezzanine card RAID controller or onboard RAID, both the half-heightandfull-heightPCIe card slots are still available for adding optional PCIe cards.

The optional PCIe RAID controllers are all half-heightPCIe cards. If you choose one of these cards, only thefull-heightPCIe card slot will be available for adding an optional PCIe card.

Note that only a single Cisco VIC card (either the full-heightCisco UCS P81E or thehalf-heightCisco VIC 1225 PCIe card) is supported and it must be installed in thefull-heightPCIe slot (slot 1) on riser 1. So take this into account when populating RAID controller cards.

You can choose only one RAID controller (embedded RAID, plug-inPCIe RAID controller, or mezzanine card RAID controller).

You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is preconfigured at the factory. The RAID level you choose must be an available RAID choice for the controller selected. RAID levels 50 and 60 are supported, although they are not available as configuration options.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

21

CONFIGURING the SERVER

STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs)

The standard disk drive features are:

2.5-inchsmall form factor

Hot-pluggable

Sled-mounted

Select Drives

The available drives are listed in Table 8.

Table 8 Available Hot-PluggableSled-MountedHDDs and SSDs

Product ID (PID)

PID Description

Drive

Capacity

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

HDDs

 

 

 

 

 

 

 

 

 

 

 

A03-D1TBSATA

1TB SATA 7.2K RPM SFF HDD

SATA

1 TB

UCS-HDD900GI2F106

900

GB 6Gb SAS 10K RPM SFF HDD

SAS

900 GB

A03-D600GA2

600

GB 6Gb SAS 10K RPM SFF HDD

SAS

600 GB

A03-D500GC3

500

GB SATA 7.2K RPM SFF HDD

SATA

500 GB

UCS-HDD300GI2F105

300

GB 6Gb SAS 15K RPM SFF HDD

SAS

300 GB

A03-D300GA2

300

GB 6Gb SAS 10K RPM SFF HDD

SAS

300 GB

 

 

 

 

 

 

 

SSDs

 

 

 

 

 

 

 

 

 

 

 

UCS-SD300G0KA2-E

300GB Std Height 15mm SATA SSD

SATA

300 GB

UCS-SD200G0KA2-E

200GB Std Height 15mm SATA SSD

SATA

200 GB

UCS-SD100G0KA2-E

100GB Std Height 15mm SATA SSD

SATA

100 GB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: No RAID option can be chosen if you have no drives

NOTE: No virtual drive groupings are allowed if you mix HDDs and SSDs.

22

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Approved Configurations

(1)Onboard RAID, Mezzanine Cards, and all Plug-InRAID Controllers

If you have not selected an onboard RAID upgrade option (ROM5 or ROM55), a mezzanine card, or a plug-inRAID controller, you may select up to 4SATA-onlydrives.

Otherwise, select up to eight SAS/SATA drives listed in Table 8. You can mix SAS and SATA drives.

Caveats

You can mix SATA and SAS drives.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

23

CONFIGURING the SERVER

STEP 6 SELECT PCIe OPTION CARD(s)

The standard PCie card offerings are:

Converged Network Adapters (CNAs)

Network Interface Cards (NICs)

Host Bus Adapters (HBAs)

Select PCIe Option Cards

The available PCIe option cards are listed in Table 9.

Table 9 Available PCIe Option Cards

Product ID (PID)

PID Description

Card

Height

 

 

 

 

Converged Network Adapters (CNAs)

 

 

 

 

N2XX-ACPCI01

Cisco UCS P81E Virtual Interface Card (VIC)/ 2-port10Gbps

Full

UCSC-PCIE-BSFP

Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI

Half

UCSC-PCIE-CSC-02

Cisco VIC 1225 Dual Port 10Gb SFP+ CNA

Half

 

 

Network Interface Cards (NICs)

 

 

 

 

N2XX-ABPCI01-M3

Broadcom 5709 Dual Port 1Gb w/TOE iSCSI for M3 Servers

Half

N2XX-ABPCI03-M3

Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers

Half

N2XX-AIPCI01

Intel X520 Dual Port 10Gb SFP+ Adapter

Half

UCSC-PCIE-IRJ45

Intel i350 Quad Port 1Gb Adapter

Half

UCSC-PCIE-BTG

Broadcom 57712 Dual Port 10GBASE-Tw/TOE iSCSI

Half

 

 

Host Bus Adapters (HBAs)

 

 

 

 

N2XX-AEPCI03

Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA

Half

N2XX-AEPCI05

Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA

Half

N2XX-AQPCI03

Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA

Half

N2XX-AQPCI05

Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA

Half

 

 

 

24

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Approved Configurations

(1)No RAID controller plug-incard

If you did not choose a plug-inRAID controller (for example, you are using embedded RAID or a mezzanine RAID controller), you can select up to two PCie option cards listed in

Table 9.

(2)One RAID controller plug-incard

If you selected a plug-inPCIe RAID controller, you can select only one of the optional PCIe cards listed inTable 9.

NOTE: If aplug-inRAID controller card is installed, any optional PCIe card you select will be installed in thefull-heightslot. RAID controllers are always installed in thehalf-heightslot.

Caveats

For 1-CPUsystems:

Only the full-heightPCIe slot (slot 1) is supported

Neither PCIe slot 2 nor the mezzanine card slot are supported

Only a single VIC card (either the full-heightCisco UCS P81E or the Cisco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (thefull-heightslot).

For 2-CPUsystems:

Both PCIe slots and the mezzanine card slot are supported

Only a single VIC card (either the full-heightCisco UCS P81E or thehalf-heightCisco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full height slot).

All PCIe cards will fit in either slot, except the Cisco UCS P81E Virtual Interface Card (VIC), which must be installed in the full-heightslot (slot 1).

Other considerations for the Cisco VIC 1225:

Supports 10G SFP+ optical and copper twinax connections

Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active.

To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS Manager 2.1(0) or later, the minimum card-firmwareand uboot image level is 2.1(0.306).

To help ensure that your operating system is compatible with the card you have selected, check the Hardware Compatibility List at this URL:

http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

25

CONFIGURING the SERVER

STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES

Copper twinax cables and SFP optical modules may be ordered to support the two-portnetwork cards that are available with the server.

Choose Optional Twinax Cables

Table 10 lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.

Table 10 Available Twinax Cables

Product ID (PID)

PID Description

 

 

SFP-H10GB-CU1MSFP-H10GB-CU3MSFP-H10GB-CU5MSFP-H10GB-ACU7MSFP-H10GB-ACU10M

10GBASE-CUSFP+ Cable (1 M)

10GBASE-CUSFP+ Cable (3 M)

10GBASE-CUSFP+ Cable (5 M)

10GBASE-CUSFP+ Cable (7 M)

10GBASE-CUSFP+ Cable (10 M)

Approved Configurations

(1)Choose Up to Two Twinax Cables for Each Network Card Ordered

You may choose one or two twinax cables for each network card ordered. The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.

Caveats

The twinax cables listed in Table 10 can be ordered only for the following PCIe cards:

N2XX-ACPCI01(Cisco UCS P81E Virtual Interface Card/2-port10Gbps)

UCS-PCIE-BSFP(Broadcom 57712)

N2XX-AEPCI01(EmulexOCe10102-F)

N2XX-AIPCI01(Intel Dual Port Ethernet X520)

UCSC-PCIE-CSC-02(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)

26

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Choose Optional SFP Modules

Optical Cisco SFP+ modules are listed in Table 11.

Table 11 Available SFP Modules

Product ID (PID)

PID Description

 

 

SFP-10G-SR

10GBASE-SRSFP+ Module

 

850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

 

 

DS-SFP-FC8G-SW

8 Gbit SFP+ Module

 

850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

 

 

Approved Configurations

(1)Choose Up to Two SFP+ Modules for Each Network Card Ordered

You may choose one or two SFP+ optical modules cables for each network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.

See Figure 5 on page 28 for typical SFP+ and twinax connections to the network cards.

Caveats

The SFP-10G-SRoptical module listed inTable 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules:

N2XX-ACPCI01(Cisco UCS P81E Virtual Interface Card/2-port10Gbps)

UCSC-PCIE-BSFP(Broadcom 57712)

N2XX-ABPCI02(Broadcom 57711)

N2XX-AEPCI01(EmulexOCe10102-F)

UCSC-PCIE-CSC-02(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)

The DS-SFP-FC8G-SWoptical module listed inTable 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules:

N2XX-AEPCI05(Emulex LPe 12002, 8Gbdual-portFibre Channel HBA)

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

27

CONFIGURING the SERVER

Figure 5 Network Card Connections

28

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 8 ORDER POWER SUPPLY

The C220 M3 SFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply. A fully loaded server might need to be powered with two 450 W or two 650 W power supplies (see Table 12). Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on):

https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

Table 12

Power Supply PIDs

 

 

Product ID (PID)

PID Description

 

 

UCSC-PSU-450W

450 W power supply

UCSC-PSU-650W

650 W power supply

 

 

 

 

 

 

NOTE: In a two power supply server, both power supplies must be identical.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

29

CONFIGURING the SERVER

STEP 9 SELECT AC POWER CORD(s)

Using Table 13, select the appropriate AC power cords. You can select a minimum of no power cords and a maximum of two. If you select the optionR2XX-DMYMPWRCORD,no power cord is shipped with the server.

Table 13 Available Power Cords

Product ID (PID)

PID Description

Images

 

 

 

R2XX-DMYMPWRCORD

No power cord (dummy PID to

 

allow for a no power cord option)

CAB-N5K6A-NA

Power Cord, 200/240V 6A, North

 

America

CAB-AC-250V/13APower Cord, NEMAL6-20250V/20A

plug-IEC320/C13receptacle, North

America,

Not applicable

 

Cordset rating: 10 A, 250 V

Plug: NEMA 6-15P

Length: 8.2 ft

 

Connector:

 

IEC60320/C13

 

186570

 

Cordset rating 13A, 250V

 

 

(6.6 feet) (79±2m)

 

Plug:

Connector:

 

EL 701

 

EL312MoldedTwistlock

 

(IEC60320/C13)

186568

(NEMA L6-20)

 

 

 

CAB-C13-CBN

CABASY,WIRE,JUMPER CORD, 27" L,

 

C13/C14, 10A/250V

CAB-C13-C14-2M

CABASY,WIRE,JUMPER CORD, PWR,

 

2 Meter, C13/C14,10A/250V

CAB-C13-C14-ACCORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M

30

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

Table 13 Available Power Cords

Product ID (PID)

PID Description

Images

 

 

 

SFS-250V-10A-AR

Power Cord, SFS, 250V, 10A,

 

Argentina

CAB-9K10A-AU

Power Cord, 250VAC 10A 3112 Plug,

 

Australia

SFS-250V-10A-CN

Power Cord, SFS, 250V, 10A, China

CAB-250V-10A-CN

AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU

Power Cord, 250VAC 10A CEE 7/7

 

Plug, EU

SFS-250V-10A-ID

Power Cord, SFS, 250V, 10A, India

SFS-250V-10A-IS

Power Cord, SFS, 250V, 10A, Israel

 

2500 mm

 

 

Cordset rating: 10 A, 250/500 V MAX

 

 

Length: 8.2 ft

 

Plug:

 

 

EL 219

 

 

(IRAM 2073)

Connector:

 

 

EL 701

 

 

(IEC60320/C13)

186571

 

 

Cordset rating: 10 A, 250 V/500 V MAX

 

 

Length: 2500mm

 

 

 

Connector:

 

Plug:

EL 701C

 

EL 210

(EN 60320/C15)

186580

(BS 1363A) 13 AMP fuse

 

 

 

Plug:

Cordset rating 10A, 250V

EL 218

(2500 mm)

(CCEE GB2009)

Connector:

 

EL 701

186573

(IEC60320/C13)

 

Cordset rating: 10A/16 A, 250 V

 

Plug:

Length: 8 ft 2 in. (2.5 m)

 

 

 

M2511

 

 

 

Connector:

 

 

VSCC15

186576

 

 

Plug:

Cordset rating 16A, 250V

EL 208

(2500mm)

Connector:

EL 701

187490

EL-212

 

16A

 

250V

 

 

Cordset rating 10A, 250V/500V MAX

 

(2500 mm)

 

Connector:

Plug:

EL 701B

(IEC60320/C13)

EL 212

186574

(SI-32)

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

31

CONFIGURING the SERVER

Table 13 Available Power Cords

Product ID (PID)

PID Description

Images

 

 

 

CAB-9K10A-IT

Power Cord, 250VAC 10A CEI

 

23-16/VIIPlug, Italy

CAB-9K10A-SW

Power Cord, 250VAC 10A MP232

 

Plug, Switzerland

CAB-9K10A-UK

Power Cord, 250VAC 10A BS1363

 

Plug (13 A fuse), UK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cordset rating: 10 A, 250 V

 

Plug:

 

 

Length: 8 ft 2 in. (2.5 m)

Connector

 

 

 

 

 

I/3G

 

 

 

 

 

C15M

(CEI 23-16)

 

 

 

 

 

(EN60320/C15 )

186575

 

Cordset rating: 10 A, 250 V

Plug:

Length: 8 ft. 2 in (2.5 m)

 

MP232-R

Connector:

 

 

IEC 60320 C15

 

186578

Cordset rating: 10 A, 250 V/500 V MAX

 

 

Length: 2500mm

 

 

 

Connector:

 

Plug:

EL 701C

 

EL 210

(EN 60320/C15)

186580

(BS 1363A) 13 AMP fuse

 

 

 

CAB-9K12A-NA

Power Cord, 125VAC 13A NEMA

 

5-15Plug, North America

CAB-JPN-3PIN

Power Cord 3PIN, Japan

Image not available

 

 

 

32

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM

The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use Table 14 to order a cable management arm.

Table 14

Cable Management Arm

 

 

Product ID (PID)

PID Description

 

 

 

UCSC-CMA1

 

Cable Management Arm for C220 rack servers

 

 

 

For more information about the cable management arm, see the Cisco UCS C220 M3 Installation and Service Guide at this URL:

http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/C220.pdf

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

33

CONFIGURING the SERVER

STEP 11 ORDER A TRUSTED PLATFORM MODULE

Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.

The TPM ordering information is listed in Table 15.

Table 15 Trusted Platform Module

Product ID (PID)

PID Description

 

 

UCSX-TPM1-001Trusted Platform Module

34

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL)

You can order one optional 16 GB Cisco Flexible Flash secure digital (SD) card. This SD card contains preloaded software for simplified server operation. The ordering information is listed in Table 16.

Table 16

Secure Digital (SD) Card

 

 

Product ID (PID)

PID Description

 

 

UCSC-SD-16G-C220

16GB SD Card for C220 servers

 

 

 

See Figure 6 on page 47 for the location of the SD cards. There are two locations, SD1 and SD2; however, at present only SD1 is supported.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

35

CONFIGURING the SERVER

STEP 13 ORDER OPTIONAL USB 2.0 DRIVE

You may order one optional USB 2.0 drive. The USB drive ordering information is listed in

Table 17.

Table 17

USB 2.0 Drive

 

 

Product ID (PID)

PID Description

 

 

UCS-USBFLSH-S-4GB

4GB Flash USB Drive (shorter length) for all servers except C260

 

 

 

See Figure 6 on page 47 for the location of the USB connector.

36

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 14 SELECT OPERATING SYSTEM

Several operating systems are available from which to choose. Select one of the operating systems shown in Table 18.

Table 18 Operating Systems

PID Description Product ID (PID)

SUSE Linux Enterprise Server

SLES-1A

SLES/1yr subscription/svcs required/0 media

SLES-3A

SLES/3yr subscription/svcs required/0 media

Red Hat Enterprise Linux

RHEL-2S-1G-1ARHEL/2 Socket/1 Guest/1Yr Svcs Required

RHEL-2S-1G-3ARHEL/2 Socket/1 Guest/3Yr Svcs Required

RHEL-2S-4G-1ARHEL/2 Socket/4 Guest/1Yr Svcs Required

RHEL-2S-4G-3ARHEL/2 Socket/4 Guest/3Yr Svcs Required

RHEL-2S-UG-1ARHEL/2 Socket/U Guest/1Yr Svcs Required

RHEL-2S-UG-3ARHEL/2 Socket/U Guest/3Yr Svcs Required

RHEL Add-Ons

RHEL-HA-2S-1ARHEL-RS-2S-1ARHEL-SFS-2S-1ARHEL-HA-2S-3ARHEL-RS-2S-3ARHEL-SFS-2S-3A

RHEL Option/High-Availability/2Socket/1Yr Svcs Required RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required RHELOption/High-Availability/2Socket/3Yr Svcs Required RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd RHEL Option/Scalable File System/2 Socket/3 Yr Svcs Required

Windows Server

MSWS-08R2-STHVMSWS-08R2-ENHVMSWS-08R2-DCHV2SMSWS-08R2-DCHV4S

Windows Svr 2008 ST media R2 ST (1-4CPU,5CAL) Windows Svr 2008 EN media R2 EN(1-8CPU,25CAL) Windows Svr 2008R2-2CPU-DataCenter

Windows Svr 2008 R2-4CPU-DataCenter

VMWare Server

VMW-VS5-STD-1AVMware vSphere 5 Standard for 1 Processor, 1 Year, Support Required

VMW-VS5-STD-2AVMware vSphere 5 Standard for 1 Processor, 2 Year, Support Required

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

37

CONFIGURING the SERVER

Table 18 Operating Systems (continued)

PID Description

Product ID (PID)

 

 

VMW-VS5-STD-3AVMW-VS5-STD-4AVMW-VS5-STD-5AVMW-VS5-ENT-1AVMW-VS5-ENT-2AVMW-VS5-ENT-3AVMW-VS5-ENT-4AVMW-VS5-ENT-5AVMW-VS5-ENTP-1AVMW-VS5-ENTP-2AVMW-VS5-ENTP-3AVMW-VS5-ENTP-4AVMW-VS5-ENTP-5A

VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Required VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Required VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Required VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Required VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Required VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Required VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Required VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Required

VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Required VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Required VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Required VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Required VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Required

38

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 15 SELECT OPERATING SYSTEM MEDIA KIT

Select the optional operating system media listed in Table 19.

Table 19

OS Media

 

 

 

Product ID (PID)

PID Description

 

 

 

RHEL-6

SLES-11MSWS-08R2-STHV-RMMSWS-08R2-ENHV-RMMSWS-08R2-DCHV-RM

RHEL 6 Recovery Media Only (Multilingual) SLES 11 media only (multilingual)

Windows Svr 2008 R2 ST (1-4CPU,5CAL), Media Windows Svr 2008 R2 EN(1-8CPU,25CAL), Media Windows Svr 2008 R2 DC(1-8CPU,25CAL), Media

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

39

CONFIGURING the SERVER

STEP 16 SELECT OPTIONALVALUE-ADDEDSOFTWARE

You can select from a variety of value-addedsoftware listed inTable 20.

Table 20

Value Added Software

 

 

Product ID (PID)

PID Description

 

 

 

BMC-SE-4C

 

BMC BladeLogic Standard Edition, 4 Cores, Support Required

BMC-SE-6C

 

BMC BladeLogic Standard Edition, 6 Cores, Support Required

BMC-SE-8C

 

BMC BladeLogic Standard Edition, 8 Cores, Support Required

BMC-SE-10C

BMC BladeLogic Standard Edition, 10 Cores, Support Required

BMC-AE-4C

 

BladeLogic Advanced Edition, 4 Cores, Support Required

BMC-AE-6C

 

BMC BladeLogic Advanced Edition, 6 Cores, Support Required

BMC-AE-8C

 

BMC BladeLogic Advanced Edition, 8 Cores, Support Required

BMC-AE-10C

BMC BladeLogic Advanced Edition, 10 Cores, Support Required

BMC-002

 

BMC BladeLogic CM for Physical Cisco Servers

BMC-012

 

BMC BPPM Per Server

VMW-VC5-STD-1A

VMware vCenter 5 Standard for 1 Processor, 1 Year, Support Required

VMW-VC5-STD-2A

VMware vCenter 5 Standard for 1 Processor, 2 Year, Support Required

VMW-VC5-STD-3A

VMware vCenter 5 Standard for 1 Processor, 3 Year, Support Required

VMW-VC5-STD-4A

VMware vCenter 5 Standard for 1 Processor, 4 Year, Support Required

VMW-VC5-STD-5A

VMware vCenter 5 Standard for 1 Processor, 5 Year, Support Required

N1K-VLEM-UCS-1

Nexus 1000V License PAK for 1 Virtual Ethernet module

N1K-CSK9-UCS-404

Nexus 1000V VSM Virtual Appliance Software

 

 

 

40

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

CONFIGURING the SERVER

STEP 17 SELECT SERVICE and SUPPORT LEVEL

A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract

If you have noncritical implementations and choose no service contract, the following coverage is supplied:

Three-yearparts coverage.

Next business day (NBD) parts replacement eight hours a day, five days a week.

90-daysoftware warranty on media.

Downloads of BIOS, drivers, and firmware updates.

UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.

Unified Computing Support Service

For support of the entire Cisco Unified Computing System, Cisco offers the Cisco Unified Computing Support Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to the Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.

For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-timealerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Unified Computing Support Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed inTable 21.

Table 21

UCS Computing Support Service

 

 

 

Product ID (PID)

On Site?

Description

 

 

 

CON-UCS1-C220-M3-W

No

UC Support 8X5XNBD

CON-UCS2-C220-M3-W

No

UC Support 8X5X4

CON-UCS3-C220-M3-W

No

UC Support 24x7x4

CON-UCS4-C220-M3-W

No

UC Support 24x7x2

CON-UCS5-C220-M3-W

Yes

UC Support 8X5XNBD

CON-UCS6-C220-M3-W

Yes

UC Support 8X5X4

CON-UCS7-C220-M3-W

Yes

UC Support 24x7x4

CON-UCS8-C220-M3-W

Yes

UC Support 24x7x2

 

 

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

41

CONFIGURING the SERVER

Unified Computing Warranty Plus Service

For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service. You can choose from several levels of advanced parts replacement coverage, including onsite parts replacement in as little as two hours. Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. See Table 22.

Table 22 UCS Computing Warranty Plus Service

Product ID (PID)

On Site?

Description

 

 

 

CON-UCW2-C220-M3-W

No

UC Warranty Plus 8x5x4

CON-UCW3-C220-M3-W

No

UC Warranty Plus 24x7x4

CON-UCW4-C220-M3-W

No

UC Warranty Plus 24x7x2

CON-UCW5-C220-M3-W

Yes

UC Warranty Plus 8X5XNBD

CON-UCW6-C220-M3-W

Yes

UC Warranty Plus 8X5X4

CON-UCW7-C220-M3-W

Yes

UC Warranty Plus 24x7x4

CON-UCW8-C220-M3-W

Yes

UC Warranty Plus 24x7x2

 

 

 

Unified Computing Drive Retention Service

With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.

Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in Table 23.

NOTE: Cisco does not offer a certified drive destruction service as part of this service.

42

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

 

 

 

 

CONFIGURING the SERVER

 

 

 

 

 

Table 23 Drive Retention Service Options

 

 

 

 

 

 

 

 

 

 

Service Description

Service

Service

Service Level

Product ID (PID)

Program Name

Level GSP

 

 

 

 

 

 

 

 

 

UCS Mission Critical

UC CRIT DR

UCMD7

24x7x4 Onsite

CON-UCMD7-C220-M3-WSFF

Support Service

 

 

 

 

 

With Drive

 

 

 

 

 

Retention

 

 

 

 

 

 

 

UCMD8

24x7x2 Onsite

CON-UCMD8-C220-M3-WSFF

 

 

 

 

 

UCS Support

UC SUPP DR

UCSD1

8x5xNBD

CON-UCSD1-C220-M3-WSFF

Service With Drive

 

 

 

 

 

Retention

 

 

 

 

 

 

 

UCSD2

8x5x4

CON-UCSD2-C220-M3-WSFF

 

 

UCSD3

24x7x4

CON-UCSD3-C220-M3-WSFF

 

 

UCSD4

24x7x2

CON-UCSD4-C220-M3-WSFF

 

 

UCSD5

8x5xNBD

CON-UCSD5-C220-M3-WSFF

 

 

 

Onsite

 

 

 

 

UCSD6

8x5x4 Onsite

CON-UCSD6-C220-M3-WSFF

 

 

UCSD7

24x7x4 Onsite

CON-UCSD7-C220-M3-WSFF

 

 

UCSD8

24x7x2 Onsite

CON-UCSD8-C220-M3-WSFF

 

 

 

 

 

UCS Warranty Plus

UC PLUS DR

UCWD2

8x5x4

CON-UCWD2-C220-M3-WSFF

With Drive

 

 

 

 

 

Retention

 

 

 

 

 

 

 

UCWD3

24x7x4

CON-UCWD3-C220-M3-WSFF

 

 

UCWD4

24x7x2

CON-UCWD4-C220-M3-WSFF

 

 

UCWD5

8x5xNBD

CON-UCWD5-C220-M3-WSFF

 

 

 

Onsite

 

 

 

 

UCWD6

8x5x4 Onsite

CON-UCWD6-C220-M3-WSFF

 

 

UCWD7

24x7x4 Onsite

CON-UCWD7-C220-M3-WSFF

 

 

UCWD8

24x7x2 Onsite

CON-UCWD8-C220-M3-WSFF

 

 

 

 

 

 

Mission Critical Support Service

This service delivers personalized technical account management, expedited technical support, and expert field support engineering for the Cisco Unified Computing System (UCS).

The Mission Critical Support Service provides a designated technical account manager (TAM) who acts as a strategic resource to help ensure that the unified computing environment runs at peak efficiency. If a problem arises that threatens business continuity, the TAM provides crisis management leadership, and your IT staff receives expedited access to Cisco's Technical Assistance Center (TAC).

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

43

CONFIGURING the SERVER

Mission Critical Support Service is a layered service available for all Cisco data center products already support by a UCS Support Service or SMARTnet service contract. For further information about Cisco Mission Critical Support Service, please consult the Service Description that can be found at the following link:

http://www.cisco.com/web/about/doing_business/legal/service_descriptions/index.html

or contact your Cisco account Manager.

For more service and support information, see this URL:

http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf

For a complete listing of available services for Cisco Unified Computing System, see this URL:

http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

44

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

OPTIONAL STEP - ORDER RACK(s)

OPTIONAL STEP - ORDER RACK(s)

The optional R42610 rack is available from Cisco for the C-Seriesservers, including the C220 M3 SFF server. This rack is a standard19-inchrack and can be ordered with a variety of options, as listed inTable 24. Racks are shipped separately from the C220 M3 SFF server.

Table 24

Racks and Rack Options

 

 

Product ID (PID)

PID Description

 

 

 

RACK-UCS1

 

Cisco R42610 expansion rack, no side panels

RACK-UCS21

Cisco R42610 standard rack, w/side panels

RACK-BLANK-001

Filler panels (qty 12), 1U, plastic, toolless

RACK-CBLMGT-001

Cable mgt D rings (qty 10), metal

RACK-CBLMGT-011

Cable mgt straps (qty 10), Velcro

RACK-FASTEN-001

Mounting screws (qty 100), M6

RACK-FASTEN-002

Cage nuts (qty 50), M6

RACK-JOIN-001

Rack joining kit

Notes . . .

1. Use these same base PIDs to order spare racks (available only as next-dayreplacements).

For more information about the R42610 rack, see RACKS, page 55.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

45

OPTIONAL STEP - ORDER PDU

OPTIONAL STEP - ORDER PDU

An optional power distribution unit (PDU) is available from Cisco for the C-Seriesrack servers, including theC220 M3 server. This PDU is available in a zero rack unit (RU) style (seeTable 24).

Table 25

PDU Options

 

 

Product ID (PID)

PID Description

 

 

RP208-30-2P-U-2

Zero RU PDU

 

 

 

For more information about the PDU, see PDUs, page 57.

46

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL

CHASSIS

An internal view of the C220 M3 chassis with the top cover removed is shown in Figure 6.

Figure 6 C220 M3 SFF With Top Cover Off

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

SAS1

 

 

 

11

 

 

 

 

 

SAS2

 

 

 

 

 

 

FAN1

 

 

SAS1

SAS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCIe1

 

 

 

FAN2

 

CPU1

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

PCIe2

13

 

 

 

 

 

 

 

 

14

 

 

FAN3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSU2

15

 

 

 

 

 

 

 

 

 

 

 

FAN4

 

CPU2

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

FAN5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSU1

 

 

 

 

 

 

18

17

 

 

 

1

Drives

10

Trusted platform module socket on

 

(hot-swappable,accessed through front panel)

 

motherboard

 

 

 

 

2

Drive backplane

11

Standard-profilePCIe riser (PCIe slot 1)

 

 

 

 

3

SuperCap backup unit mounting location

12

Low-profilePCIe riser (PCIe slot 2)

 

 

 

 

4

Cooling fans (five)

13

Cisco Flexible Flash SD socket SD2 on PCIe

 

 

 

riser 2

 

 

 

 

5

SCU upgrade ROM header (RAID key).

14

Cisco Flexible Flash SD socket SD1 on PCIe

 

 

 

riser 2

 

 

 

 

6

DIMM slots on motherboard (16)

15

Internal USB port

 

 

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

47

SUPPLEMENTAL MATERIAL

7

CPUs and heatsinks (two)

16

Power supplies (two, hot-swappable

 

 

 

access through rear panel)

 

 

 

 

8

Integrated RAID on motherboard, and mini-SAS

17

RTC battery on motherboard

 

connectors

 

 

 

 

 

 

9

Mezzanine RAID card, mini-SASconnectors

18

Software RAID 5 header (RAID key).

 

SAS1 and SAS2

 

 

 

 

 

 

CPUs and DIMMs

Physical Layout

Each CPU has four DIMM channels:

CPU1 has channels A, B, C, and D

CPU2 has channels E, F, G, and H

Each DIMM channel has two banks: bank 1 and bank 2. The blue-coloredDIMM banks are for bank 1 and theblack-coloredare for bank 2.

As an example, DIMM slots A1, B1, C1, and D1 belong to bank 1, while A2, B2, C2, and D2 belong to bank 2.

Figure 7 shows how banks and channels are physically laid out on the motherboard. The DIMM slots on the right (channels A, B, C, and D) are associated with CPU1, while the DIMM slots on the left (channels E, F, G, and H) are associated with CPU2. The bank 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding bank 2 (black) slots. Bank 1 slots (blue) are populated before bank 2 slots (black).

48

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Figure 7 Physical Layout of CPU DIMM Channels and Banks

C1

C2

D1

D2

CPU1

Front

B2

B1

 

of

A2

A1

G1

Server

H2

 

G2

 

H1

CPU2

F2

F1

E2

E1

331707

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

49

SUPPLEMENTAL MATERIAL

Memory Population Rules

When considering the memory configuration of your server, you should consider the following items:

For optimum performance, populate at least one DIMM per memory channel per CPU. If using 4 GB DIMMs, you must populate 2 DIMMs per CPU memory channel.

The server supports registered DIMMs (RDIMMs) or load-reducedDIMMS (LRDIMMs), however, do not mix RDIMMs and LRDIMMs in a server.

Each channel has two DIMM slots (for example, channel A = slots A1 and A2).

A channel can operate with one or two DIMMs installed.

If a channel has only one DIMM, populate slot 1 first (the blue slot).

When both CPUs are installed, populate the DIMM slots of each CPU identically.

Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1

Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2

Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.

Observe the DIMM mixing rules shown in Table 26

Table 26 DIMM Mixing Rules for C220 M3 Server

DIMM Parameter Mixed

Mix Across a Single Bank?

Mix Across Multiple Banks?

 

 

 

DIMM Size (4, 8, 16 GB)

No—Mustbe same size in the

 

same bank

Yes—Differentbanks can use different DIMM sizes (as long as all DIMMs in a single bank use the same DIMM size).

DIMM Speed

No—Mustbe same speed in

(1066, 1333, or 1600 MHz)1

the same bank.

DIMM Type (R-DIMM)

No—AllDIMMs in a bank must

 

be same type.

No—AllDIMMs in the server must be same speed.

No—AllDIMMs in the server must be same type.

Notes . . .

1. Only 1333 and 1600 MHz DIMMs are currently available for the C220 M3 server.

50

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Recommended Memory Configuration

This section explains the recommended DIMM population order rules for the C220 M3 server.

All DIMMs must be DDR3 DIMMs.

Do not mix:

DIMMs with different sizes or clock rates in a bank

RDIMMs and LRDIMMs

ECC and non-ECCDIMMs

There are blue and black DIMM slots. Populate blue slots first.

When singleand dual-rankDIMMs are populated for 2DPC, always populate thedual-rankDIMM in the blue DIMM slot and thesingle-rankDIMM in the black DIMM slot.

Many memory configurations are possible. For best results, follow Table 27 when populating DIMMs.

Table 27 Recommended Memory Configurations

Total

CPU 1 DIMMs

CPU 2 DIMMs

DIMM Max

Total

 

 

 

 

System

Blue Slots

Black Slots

Blue Slots

Black Slots

Operating

DIMMs in

Memory

Bank 1

Bank 2

Bank 1

Bank 2

Speed

the

Size

(A1, B1,

(A2, B2,

(E1, F1,

(E2, F2,

(MHz)

System1

 

C1, D1)

C2, D2)

G1, H1)

G2, H2)

 

 

32 GB

4x4 GB

4x4 GB

1600

8

 

 

 

 

 

 

 

 

2x8 GB

2x8 GB

1600

4

 

 

 

 

 

 

 

64 GB

4x4 GB

4x4 GB

4x4 GB

4x4 GB

1600

16

 

 

 

 

 

 

 

 

4x8 GB

4x8 GB

1600

8

 

 

 

 

 

 

 

 

1x32 GB

1x32GB

1600

2

 

 

 

 

 

 

 

96 GB

4x8 GB

2x8 GB

4x8 GB

2x8 GB

1600

12

 

 

 

 

 

 

 

 

3x16 GB

3x16 GB

1600

6

 

 

 

 

 

 

 

 

4x8 GB

4x4 GB

4x8 GB

4x4 GB

1600

16

 

 

 

 

 

 

 

 

1x32 GB

1x16 GB

1x32 GB

1x16 GB

1600

4

 

 

 

 

 

 

 

128 GB

4x8 GB

4x8 GB

4x8 GB

4x8 GB

1600

16

 

 

 

 

 

 

 

 

4x16 GB

4x16 GB

1600

8

 

 

 

 

 

 

 

 

1x32 GB

1x32GB

1x32 GB

1x32GB

1600

8

 

 

 

 

 

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

51

SUPPLEMENTAL MATERIAL

Table 27 Recommended Memory Configurations (continued)

Total

CPU 1 DIMMs

CPU 2 DIMMs

DIMM Max

Total

 

 

 

 

System

Blue Slots

Black Slots

Blue Slots

Black Slots

Operating

DIMMs in

Memory

Bank 1

Bank 2

Bank 1

Bank 2

Speed

the

Size

(A1, B1,

(A2, B2,

(E1, F1,

(E2, F2,

(MHz)

System1

 

C1, D1)

C2, D2)

G1, H1)

G2, H2)

 

 

192 GB

4x16 GB

2x16 GB

4x16 GB

2x16 GB

1600

12

 

 

 

 

 

 

 

 

4x16 GB

4x8 GB

4x16 GB

4x8 GB

1600

16

 

 

 

 

 

 

 

 

2x32 GB

1x32 GB

2x32 GB

1x32 GB

1600

6

 

 

 

 

 

 

 

256 GB

4x16 GB

4x16 GB

4x16 GB

4x16 GB

1600

16

 

 

 

 

 

 

 

 

2x32 GB

2x32 GB

2x32 GB

2x32 GB

1600

8

 

 

 

 

 

 

 

512 GB

4x32 GB

4x32 GB

4x32 GB

4x32 GB

1600

16

 

 

 

 

 

 

 

Notes . . .

1. Rows marked in yellow indicate best performance

52

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Supported DIMM Populations

The supported DIMM populations are listed in Table 28.

Table 28 Supported DIMM Configurations

 

Total DIMMs

CPU 1

 

Total DIMMs

CPU 2

Total

CPU 1 DIMMs

CPU 2 DIMMs

Capacity for

for CPU 1

Capacity

for CPU 2

Capacity

 

 

 

 

 

 

2 CPUs

 

 

 

 

 

 

 

1 x 8 GB

1

8 GB

1 x 8 GB

1

8 GB

16 GB

 

 

 

 

 

 

 

1 x 16 GB

1

16 GB

1 x 16 GB

1

16 GB

32 GB

 

 

 

 

 

 

 

2 x 4 GB

2

8 GB

2 x 4 GB

2

8 GB

16 GB

 

 

 

 

 

 

 

4 x 4 GB

4

16 GB

4 x 4 GB

4

16 GB

32 GB

 

 

 

 

 

 

 

2 x 8 GB

2

16 GB

2 x 8 GB

2

16 GB

32 GB

 

 

 

 

 

 

 

6 x 4 GB

6

24 GB

6 x 4 GB

6

24 GB

48 GB

 

 

 

 

 

 

 

8 x 4 GB

8

32 GB

8 x 4 GB

8

32 GB

64 GB

 

 

 

 

 

 

 

4 x 8 GB

4

32 GB

4 x 8 GB

4

32 GB

64 GB

 

 

 

 

 

 

 

8 x 4 GB

8

32 GB

8 x 4 GB

8

32 GB

64 GB

 

 

 

 

 

 

 

1 x 32 GB

1

32 GB

1 x 32 GB

1

32 GB

64 GB

 

 

 

 

 

 

 

5 x 8 GB

5

40 GB

5 x 8 GB

5

40 GB

80 GB

 

 

 

 

 

 

 

3 x 16 GB

3

48 GB

3 x 16 GB

3

48 GB

96 GB

 

 

 

 

 

 

 

6 x 8 GB

6

48 GB

6 x 8 GB

6

48 GB

96 GB

 

 

 

 

 

 

 

4x8 GB + 4x4 GB

8

48 GB

4x8 GB + 4x4 GB

8

48 GB

96 GB

 

 

 

 

 

 

 

7 x 8 GB

7

56 GB

7 x 8 GB

7

56 GB

112 GB

 

 

 

 

 

 

 

4 x 16 GB

4

64 GB

4 x 16 GB

4

64 GB

128 GB

 

 

 

 

 

 

 

8 x 8 GB

8

64 GB

8 x 8 GB

8

64 GB

128 GB

 

 

 

 

 

 

 

2 x 32 GB

2

64 GB

2 x 32 GB

2

64 GB

128 GB

 

 

 

 

 

 

 

5 x 16

5

80 GB

5 x 16

5

80 GB

160 GB

 

 

 

 

 

 

 

4x16 GB + 4x4 GB

8

80 GB

4x16 GB + 4x4 GB

8

80 GB

160 GB

 

 

 

 

 

 

 

6 x 16 GB

6

96 GB

6 x 16 GB

6

96 GB

192 GB

 

 

 

 

 

 

 

4x8 GB + 4x16 GB

8

96 GB

4x8 GB + 4x16 GB

8

96 GB

192 GB

 

 

 

 

 

 

 

7 x 16 GB

7

112 GB

7 x 16 GB

7

112 GB

224 GB

 

 

 

 

 

 

 

8 x 16 GB

8

128 GB

8 x 16 GB

8

128 GB

256 GB

 

 

 

 

 

 

 

4 x 32 GB

4

128 GB

4 x 32 GB

4

128 GB

256 GB

 

 

 

 

 

 

 

8 x 32 GB

8

256 GB

8 x 32 GB

8

256 GB

512 GB

 

 

 

 

 

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

53

SUPPLEMENTAL MATERIAL

Low-VoltageDIMM Considerations

The C220 M3 server can be ordered with dual-voltage(1.5/1.35 V) DIMMs only. Note the following considerations:

Low-voltageDIMMs within the server must have the identical manufacturer, type, speed, and size.

Low-voltageDIMMs andstandard-voltageDIMMs can be mixed in the same server. Note that this causes the system BIOS to default tostandard-voltageoperation (Performance Mode). That is, the server cannot operate in Power Saving Mode unless all DIMMs arelow-voltageDIMMs.

CPUs that have a maximum memory frequency less than 1333 MHz support low-voltageDIMMs operating in Power Saving Mode only, and do not support Performance Mode.

RAID Summary

The C220 M3 SFF server has an 8-drivebackplane.

ROM5 and ROM55 embedded RAID upgrade options support up to 8 drives

Mezzanine card (UCSC-RAID-11-C220)supports up to 8 drives

Mezzanine card (UCSC-RAID-MZ-220)supports up to 8 drives

SAS 9266-8iand SAS9266CV-8iPCIe cards support up to 8 drives

NOTE: If you do not select a mezzanine card, aplug-inPCIe RAID card, or one of the embedded RAID upgrade options, you will have an embeddedSATA-onlyRAID controller that supports up to fourSATA-onlydrives (RAID 0, 1, 10)

54

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

RACKS

The Cisco R42610 rack (see Figure 8) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment:

Cisco UCS B-Seriesservers and fabric interconnects

Cisco UCS C-Seriesand select Nexus switches

The rack is compatible with hardware designed for EIA-standard19-inchracks. Rack specifications are listed inTable 29.

Table 29 Cisco R42610 Rack Specifications

Parameter

Standard Rack

Expansion Rack

 

 

 

 

Dimensions (H x W x D)

78.74 x 24 x 43.38 in.

78.74 x 23.58 x 43.38 in.

 

 

(2000 x 610 x 1102 mm)

(2000 x 599 x 1102 mm)

Dimensions (H x W x D)

89 x 33 x 47 in.

89 x 33 x 47 in.

with packaging

(2261 x 838 x 1194 mm)

(2261 x 838 x 1194 mm)

Distance from front

29.2 in (741 mm)

29.2 in (741 mm)

mounting rail to rear

 

 

mounting rail

 

 

Weight

299.83 lb (136 kg)

231. 49 lb (105 kg)

Weight with packaging

354 lb

284 lb

 

 

(161 kg)

(129 kg)

Side panels included

Yes

No

Equipment mounting

42RU

42RU

capacity

 

 

Static load capacity

2100 lb

2100 lb

 

 

(954 kg)

(954 kg)

Dynamic load capacity

Not applicable

Not applicable

 

 

 

 

 

 

 

 

NOTE: The AC input connector is an IEC 320C-1415 A/250 VAC power inlet.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

55

SUPPLEMENTAL MATERIAL

Figure 8 Cisco R42610 Rack

 

 

 

Front view - door closed

 

Front view - door removed

Front view - door open

56

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

PDUs

Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.

Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.

With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floordistribution. Your IT equipment is then powered by PDU outlets in the rack using short,easy-to-managepower cords.

The C-seriessevers accept thezero-rack-unit(0RU) PDU. SeeFigure 9).

Figure 9 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)

1

Breakers

3

C19 plugs

 

 

 

 

2

Ground connection

4

C13 plugs

 

 

 

 

Cisco RP Series PDU models provide two 20-ampere(A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

57

SUPPLEMENTAL MATERIAL

KVM CABLE

The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server.

The KVM cable ordering information is listed in Table 30.

Table 30

KVM Cable

 

 

 

Product ID (PID)

PID Description

 

 

N20-BKVM

KVM cable for B-SeriesBlade Server console port

 

 

 

Figure 10

KVM Cable

 

1

Connector (to server front panel)

3

VGA connector (for a monitor)

 

 

 

 

2

DB-9serial connector

4

Two-portUSB connector (for a mouse and

 

 

 

keyboard)

 

 

 

 

58

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

SUPPLEMENTAL MATERIAL

Motherboard USB and SD Ports, and RAID Card Backup Location

The C220 M3 SFF motherboard has a general-purposeUSB socket, and two SD sockets as shown inFigure 11. The mounting location for the RAID SuperCap data cache power backup module is also shown.

Figure 11 Motherboard USB and SD Ports and RAID Card Super Capacitor Location

 

 

 

4

 

 

 

 

 

 

SAS1

 

 

 

 

 

SAS2

 

 

 

FAN1

 

SAS1

SAS2

 

 

 

 

 

 

 

 

 

 

PCIe1

 

 

FAN2

CPU1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

PCIe2

 

 

FAN3

 

 

 

 

 

 

 

 

1

 

 

 

 

 

PSU2

 

 

FAN4

CPU2

 

 

 

 

 

 

3

 

 

 

 

 

 

 

FAN5

 

 

 

 

 

 

 

 

PSU1

 

 

 

 

 

331714

1

SD1 socket

 

3

USB connector

2

SD2 socket

 

4

SuperCap module mounting location

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

59

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Dimensions and Weight

Table 31 UCS C220 M3 Dimensions and Weight

Parameter

Value

 

 

Height

1.7 in. (4.32 cm)

Width

16.92 in.(43.0 cm)

Depth

28.5 in. (72.4cm)

Front Clearance

3 in. (76 mm)

Side Clearance

1 in. (25 mm)

Rear Clearance

6 in. (152 mm)

Weight

 

Maximum (8 HDDs, 2 CPUs, 16 DIMMs, 2 power supplies)

35.6 lbs (16.2 kg)

Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply)

26.8 lbs (12.1 kg)

Bare (0 HDD, 0 CPU, 0 DIMM, 1 power supply)

22 lbs (10 kg)

 

 

Power Specifications

The general power specifications for the C220 M3 SFF server 450 W power supply are listed in Table 32.

Table 32 UCS C220 M3 SFF 450 W Power Supply Specifications

Description

Specification

 

 

AC input voltage

90 to 264 VAC self-ranging,

 

100 to 120 VAC nominal

 

200 to 240 VAC nominal

AC input frequency

Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)

Maximum AC input current

7.6 A peak at 100 VAC

 

3.65 A peak at 208 VAC

Maximum AC inrush current

11 A

Maximum output power for each

450 W

power supply

 

Power supply output voltage

Main power: 12 VDC

 

Standby power: 12 VDC

 

 

60

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

TECHNICAL SPECIFICATIONS

Table 32 UCS C220 M3 SFF 450 W Power Supply Specifications

Description

Specification

 

 

 

Power supply efficiency

CSCI Platinum

 

 

 

 

 

 

NOTE: AC input connector is an IEC 320C-1415A/250VAC power inlet.

The general power specifications for the C220 M3 SFF server 650 W power supply are listed in Table 32.

Table 33 UCS C220 M3 LFF 650 W Power Supply Specifications

Description

Specification

 

 

 

AC input voltage

90 to 264 VAC self-ranging,

 

 

100 to 120 VAC nominal

 

 

200 to 240 VAC nominal

AC input frequency

Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)

Maximum AC input current

7.6 A peak at 100 VAC

 

 

3.65 A peak at 208 VAC

Maximum AC inrush current

11 A

Maximum output power for the

650 W

power supply

 

Power supply output voltage

Main power: 12 VDC

 

 

Standby power: 12 VDC

Power supply efficiency

CSCI Platinum

 

 

 

 

 

 

NOTE: AC input connector is an IEC 320C-1415A/250VAC power inlet.

For configuration-specificpower specifications, use the Cisco UCS Power Calculator at this URL:

https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

61

TECHNICAL SPECIFICATIONS

Environmental Specifications

The power specifications for the C220 M3 server are listed in Table 34.

Table 34 UCS C220 M3 Environmental Specifications

Parameter

Minimum

 

 

Temperature operating

41 to 104° F (5 to 40° C)

 

derate the maximum temperature by 1°C per every 305m of

 

altitude above sea level

Temperature nonoperating

–40to 149°F(–40to 65°C)

Humidity (RH) nonoperating,

10 to 90%

non-condensing

 

Altitude operating

Altitude nonoperating

Sound Power level, Measure A-weightedper ISO7779 LWAd (Bels)Operation at 73°F (23°C)

0 to 3,000 m (0 to 10,000 ft.)

0 to 12,192 m (0 to 40,000 ft.)

5.4

Sound Pressure level, Measure

37

A-weightedper ISO7779 LpAm (dBA)Operation at 73°F (23°C)

62

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

TECHNICAL SPECIFICATIONS

Compliance Requirements

The regulatory compliance requirements for C-Seriesservers are listed inTable 35.

Table 35 UCS C-SeriesRegulatory Compliance Requirements

Parameter

Description

 

 

Regulatory Compliance

Products should comply with CE Markings per directives

 

2004/108/EC and 2006/95/EC

Safety

UL 60950-1Second Edition

 

CAN/CSA-C22.2No.60950-1Second Edition

 

EN 60950-1Second Edition

 

IEC 60950-1Second Edition

 

AS/NZS 60950-1

 

GB4943 2001

EMC - Emissions

47CFR Part 15 (CFR 47) Class A

 

AS/NZS CISPR22 Class A

 

CISPR22 Class A

 

EN55022 Class A

 

ICES003 Class A

 

VCCI Class A

 

EN61000-3-2

 

EN61000-3-3

 

KN22 Class A

 

CNS13438 Class A

EMC - Immunity

EN55024

 

CISPR24

 

EN300386

 

KN24

 

 

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)

63

TECHNICAL SPECIFICATIONS

64

Cisco UCS Cisco UCS C220 M3 High-DensityRack Server (Small Form Factor Disk Drive Model)