Cisco Systems 8510 User Manual

Size:
1.97 Mb
Download

QU I C KRE F E R E N C E

CATA LY S T8510

A N D LI G H TST R E A M1010 HA R D WA R EIN F O R M AT I O N

 

 

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

100 Base Fx

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

100Mbps Tx

100Mbps Tx

 

FAST ETHERNET MODULE

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

LINK Rx

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

100Mbps Tx

2

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

100Mbps Tx

3

100Mbps Tx

4

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

5

100Mbps Tx

6

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

7

100Mbps Tx

8

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

LINK Rx

 

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

100 Base Fx

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

100Mbps Tx

100Mbps Tx

 

FAST ETHERNET MODULE

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

LINK Rx

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

4

STATUS

100Mbps Tx

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

3

100Mbps Tx

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

5

100Mbps Tx

6

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

7

100Mbps Tx

8

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installing and Grounding the Chassis

WARNING: Before you install, operate, or service the system, read the Site Preparation and Safety Guide. This guide contains important safety information you should know before working with the system.

Installing the Rack

Attaching the Brackets and Guides

Cable guide

STATUS

1

 

STATUS

 

L bracket

10.36" (26.31 cm)

2

3

 

 

 

 

 

 

4

5

 

 

 

 

 

 

6

7

 

 

 

 

 

 

8

RESET

18.40"

(46.74 cm)

17.25" (43.82 cm)

WARNING: Three people are required to lift the chassis. To prevent damage to the chassis and components, never attempt to lift the chassis by the handles on the power supplies or on the interface modules, or by the plastic panels on the front of the chassis.

Installing the Chassis in a Rack

Grounding the System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 Base Fx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAST ETHERNET MODULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

STATUS

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

 

 

5

6

 

 

2

 

RESET

 

 

 

 

 

 

 

 

 

 

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

 

RESET

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

Grounding lug

Grounding

pad

Screws (M4)

Wire

Ports and Cabling

Slots 0-1:Port adapters/

0

 

100Mbps Tx

 

100Mbps Tx

 

 

 

100Mbps Tx

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

Interface modules

 

100 Base Fx

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

100Mbps Tx

 

100Mbps Tx

 

 

1

 

 

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

 

 

 

 

LINK Rx

 

 

FAST ETHERNET MODULE

 

 

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

 

 

1

100Mbps Tx

2

100Mbps Tx

3

100Mbps Tx

4

 

 

100Mbps Tx

6

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

100Mbps Tx

8

100Mbps Tx

 

 

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

 

 

Slot 2: Route processor

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

100Mbps Tx

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

Slots 3-4:Port adapters/

 

 

 

 

 

 

 

100Mbps Tx

 

100Mbps Tx

 

 

 

 

 

 

 

100 Base Fx

LINK Rx

 

 

 

 

 

 

 

 

100Mbps Tx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

 

 

 

FAST ETHERNET MODULE

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

100Mbps Tx

 

 

 

 

 

 

 

 

LINK Rx

 

 

 

 

 

 

Interface modules

4

STATUS

1

2

 

 

 

 

 

 

 

6

100Mbps Tx

7

100Mbps Tx

8

100Mbps Tx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

100Mbps Tx

3

100Mbps Tx

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

5

100Mbps Tx

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROUTE PROCESSOR

CABLE

PORTS

CONNECTORS

Ethernet port

RJ-45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Console port

EIA/TIA-232(maleDB-25)

CONSOLE

 

Auxiliary port

EIA/TIA-232(femaleDB-25)

AUX

 

PORT ADAPTER/ INTERFACE MODULE PORTS

10/100BASE-T,T1/E1,

CES, CE1 Frame Relay

100BASE-FX

or

155 Mbps, 622 Mbps

Gigabit Ethernet

E1, CES, DS3/E3, CDS3

TX

RX

CABLE CONNECTORS

RJ-45,RJ-48c

MT-RJfiber

SC-typefiber

BNC

25 Mbps

 

 

 

 

 

96-pinMolex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replacing Components

Securing an ESD Strap

Installing an Interface Module

 

or Carrier Module

POWER SUPPLY 0

WARNING: Always connect the ESD wrist strap to the ESD strap connection at the top left side of the chassis before removing any component.

Replacing a Power Supply

AC Power Supply

DC Power Supply

Captive

 

On/off

Captive

 

 

installation

switch

installation

On/off

 

screw

LED

AC power

screw

switch

Terminal

 

 

LED

 

 

inlet

 

 

block

 

 

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

48/60

 

 

 

 

 

14.0/8.0 A

STATUS

1

2

 

 

 

 

 

 

 

3

4

 

6

7

8

 

 

 

5

 

 

 

 

 

 

STATUS

 

STATUS

1

2

 

 

 

 

 

 

3

4

 

 

 

 

 

 

5

6

7

8

Insert module

 

3

 

 

 

between

 

 

module guides

 

4

STATUS

1

 

 

100Mbps Tx 2 100Mbps Tx

3

100Mbps Tx

 

 

 

 

LINK Rx

 

LINK Rx

 

 

 

STATUS

1

2

 

 

 

100Mbps Tx

100Mbps Tx

3

 

 

 

 

 

 

100Mbps Tx

 

 

 

LINK Rx

 

LINK Rx

Installing a Fan

STATUS

1

2

3

 

 

 

7

8

 

 

4

5

 

 

 

 

 

 

6

 

 

STATUS

 

 

 

 

 

 

 

 

WARNING: Always turn off the power supply unit before removing it. While holding the AC or DC power supply handle with one hand, place your other hand underneath to support the bottom of the supply.

Captive

screws

100 Base Fx

FAST ETHERNET MODULE

STATUS

1

2

 

 

STATUS

 

RESET

Fan assembly

Installing a Port Adapter

Port adapter slot 1

Port adapter slot 0 Port

adapter

Carrier

Tighten the captive

 

 

module

installation screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Insert module

 

3

 

 

 

 

 

between

 

 

module guides

 

4

STATUS

1

2 100Mbps Tx

 

 

100Mbps Tx

3

100Mbps Tx

 

 

 

 

 

LINK Rx

LINK Rx

 

LINK Rx

STATUS

1

2

 

 

 

100Mbps Tx

100Mbps Tx

3

 

 

 

 

 

 

100Mbps Tx

 

LINK Rx

 

LINK Rx

 

LINK Rx

Top View of the Route Processor

Replacing the Feature Card

Replacing an ACL Daughter Card

Edge connectors

Press Here

Press Here

Screws

Feature card

Press Here

Screws

Press Here

Route

Processor

DRAM

SIMMs

Flash

memory

SIMM

Replacing a SIMM

SIMM socket

Spring

clip

A

Protective

Mounting

guard

brackets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C85GE-2F-16K

 

-DET

RX

SYNC

TX

 

 

OP

 

100Mbps Gigabit

-DUP

LINK

 

RX

 

ETHERNET Module

 

 

 

FULL

 

 

 

 

Remove the screws and replace them with the mounting standoffs

B

 

Mounting

ACL daughter

 

 

 

standoff

 

card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C85GE-2F-16K

 

 

-DET

RX

SYNC

TX

 

 

 

OP

 

100Mbps Gigabit

 

-DUP

LINK

 

RX

 

ETHERNET Module

FULL

 

 

 

 

Align and position correctly over the mounting standoffs

Mounting

brackets

C

C85GE-2F-16K

-DET

SYNC

TX

OP

RX

 

100Mbps Gigabit

-DUP

LINK

RX

ETHERNET Module

 

FULL

 

 

Install and secure the ACL daughter card to the interface module standoffs

Route Processor LEDs

 

FAN

RESET

TX

 

1

STATUS

PS1

 

RX

 

SLOT

PS0

 

LINK

 

0

 

 

 

SLOT

 

 

 

 

 

 

 

 

 

Enet

PCMCIA

 

 

 

 

 

AUX

CONSOLE

EJECT

STATUS

FAN

 

PS1

 

PS2

System operating

STATUS

FAN

 

PS1

 

PS2

System failed

STATUS

FAN

 

PS1

 

PS2

System booting

TX

RX

LINK

No signal

TX

RX

LINK

Receiving signal

TX

RX

LINK

Transmitting signal

TX

RX

LINK

Transmitting and

Receiving

SLOT

1

0

SLOT

 

Slot 1 accessed

SLOT

1

0

SLOT

 

Slot 0 accessed

STATUS

 

RX

SLOT 0

 

RESET

TX

1

 

 

LINK

SLOT

STATUS

 

RX

SLOT 0

 

RESET

TX

1

 

 

LINK

SLOT

STATUS

 

RX

SLOT0

 

RESET

TX

1

 

 

LINK

SLOT

Installing and Removing Flash PC Cards

: Flashing LED

Route Processor Port Pinouts

STATUS

FAN

RESET

TX

PS1

RX

 

PS0

 

LINK

Enet

1

 

SLOT

 

0

 

SLOT

 

PCMCIA

EJECT

AUX

CONSOLE

Ethernet Port (RJ-45)Pinouts

Pin

Signal

Direction

Description

1

TX+

—>

Transmit data +

 

 

 

 

2

TX–

—>

Transmit data –

 

 

 

 

3

RX+

<—

Receive data +

 

 

 

 

6

RX–

<—

Receive data –

 

 

 

 

Auxiliary Port (DB-25)Pinouts

Pin

Signal

Direction

Description

1

GND

Shield ground

 

 

 

 

2

TXD

—>

Transmit data

 

 

 

 

3

RXD

<—

Receive data

 

 

 

 

4

RTS

—>

Request to send (used for

 

 

 

hardware flow control)

 

 

 

 

5

CTS

<—

Clear to send (used for

 

 

 

hardware flow control)

 

 

 

 

6

DSR

<—

Data set ready

 

 

 

 

7

Signal

Signal ground

 

ground

 

 

 

 

 

 

8

CD

<—

Carrier detect (used for modem

 

 

 

control)

 

 

 

 

20

DTR

—>

Data terminal ready (used for

 

 

 

modem control only)

 

 

 

 

22

RI

<—

Ring indicator

 

 

 

 

Console Port (DB-25)Pinouts

Pin

Signal

Direction

Description

1

GND

Ground

 

 

 

 

2

TXD

<—

Transmit data

 

 

 

 

3

RXD

—>

Receive data

 

 

 

 

4

RTS

<—

Ready to send1

5

CTS

—>

Clear to send1

6

DSR

—>

Data set ready

 

 

 

(always on)2

7

GND

Ground

 

 

 

 

8

DCD

—>

Data carrier detect

 

 

 

(always on)2

20

DTR

<—

Data terminal ready

 

 

 

 

Shield

GND

Shield ground

 

 

 

 

1.Pins 4 and 5 are connected

2.Pins 6 and 8 are connected

Port Adapter Modules

4-port25-Mbps

 

 

 

2

 

 

 

1

 

 

3

0

ATM25-4PORT

 

 

 

 

96-pinMolex connector

Available Versions

 

 

Product Number

 

 

Product Description

C85MS-ATM25-4P

 

4-portATM25 Port Adapter Module

12-port25-Mbps

11

8

5

2

10

7

4

1

9

6

3

0

ATM25-12PORT

 

 

 

96-pinMolex connector

Available Versions

 

 

Product Number

 

 

Product Description

C85MS-ATM25-12P

 

12-portATM25 Port Adapter Module

155-Mbps

TX

0

TX

1

2

TX

3

TX

 

 

 

 

RX

UTP5

RX

UTP5

UTP5

RX

UTP5

RX

155 UTP5

 

 

 

 

 

Available Versions

 

Product Number

Product Description

WAI-OC3-4U5

4-portSTS-3c/STM-1unshieldedtwisted-pair(UTP-5)Port Adapter Module

 

TX

0

 

TX

1

 

 

2

 

 

TX

3

 

TX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

 

 

RX

 

MM

RX

 

 

MM

 

 

MM

RX

MM

 

 

 

155 MM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available Versions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Number

 

 

 

 

Product Description

 

 

 

 

 

 

 

 

 

 

 

 

 

WAI-OC3-4MM

 

 

 

 

4-portSTS-3c/STM-1multi-modefiber (MMF) Port Adapter Module

 

 

 

 

 

WAI-OC3-4SS

 

 

 

 

4-portSTS-3c/STM-1single-modefiber (SMF) Port Adapter Module

 

 

 

 

 

WAI-OC3-1S3M

 

 

 

 

OC-3mix Port Adapter Module,1-portsingle-mode(SM)intermediate-reach(IR) and3-portmulti-mode

 

 

 

 

 

 

(MM) ports

 

 

 

 

 

 

 

 

 

 

 

 

 

WAI-OC3-4SSLR

 

 

 

 

4-portSTS-3c/STM-1single-mode(SM)long-reach(LR) Port Adapter Module

 

 

 

622-Mbps

 

 

 

 

 

TX

 

622 SM

 

 

 

CD

RX

SM

 

 

 

 

 

 

 

 

 

 

Available Versions

 

 

 

 

 

 

Product Number

 

 

Product Description

 

 

 

WAI-OC12-1SS

 

 

1-portSTS-12c/STM-4csingle-mode(SM) Port Adapter Module

 

 

 

TX

 

 

 

 

622 MM

CD

RX

MM

 

 

 

 

 

 

 

 

 

Available Versions

 

 

 

 

 

 

Product Number

 

 

Product Description

 

 

 

WAI-OC12-1MM

 

 

1-portSTS-12c/STM-4cmulti-modefiber (MMF) Port Adapter Module

 

WAI-OC12-1SSLR

 

 

1-portSTS-12c/STM-4csingle-mode(SM)long-reach(LR) Port Adapter Module

T1

 

 

 

 

 

 

 

0

 

1

2

 

3

S1

 

S1

 

S1

 

S1

S2

 

S2

 

S2

 

S2

CD

 

CD

 

CD

 

CD

T1 DSX1

 

 

 

 

 

 

Available Versions

 

 

 

 

 

 

Product Number

 

 

Product Description

 

 

 

WAI-T1-4RJ48

 

 

4-portT1 (ATM) withRJ-48interface Port Adapter Module

 

 

E1

 

 

 

 

 

 

 

0

 

1

2

 

3

TX

 

TX

 

TX

 

TX

RX

 

RX

 

RX

 

RX

CD

 

CD

 

CD

 

CD

E1 DSX1

 

 

 

 

 

 

Available Versions

 

 

 

 

 

 

Product Number

 

 

Product Description

 

 

 

WAI-E1-RJ48

 

 

4-portE1 (ATM) withRJ-48interface Port Adapter Module

 

 

TX

0

RX

 

TX

1

RX

 

TX

2

RX

 

TX

3

RX

 

 

 

 

 

 

 

 

 

TX

 

RX

CD

TX

 

RX

CD

TX

 

RX

CD

TX

 

RX

CD

E1 75Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available Versions

 

Product Number

Product Description

WAI-E1-4BNC

4-portE1 (ATM) with BNC interface Port Adapter Module

8-portT1 and E1 IMA

 

0

 

1

 

 

2

 

3

 

4

 

5

 

6

 

7

PWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAIL

TX

RX

TX

CD

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

TX

RX

8T1-IMA

CD

 

 

 

CD

 

CD

 

CD

 

CD

 

CD

 

CD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available Versions

 

 

Product Number

Product Description

C85MS-8T1-IMA

C8500MSR/LS1010

8-portT1 IMA Port Adapter Module

C85MS-8E1-IMA-120

C8500MSR/LS1010

8-portE1120-ohmIMA Port Adapter Module

4-portCES E1 and T1

 

 

 

 

 

 

 

 

 

 

 

TX

0

RX

 

TX

1

RX

 

TX

2

RX

 

TX

3

RX

 

 

 

 

 

 

 

 

 

TX

 

RX

CD

TX

 

RX

CD

TX

 

RX

CD

TX

 

RX

CD

CES E1 75Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available Versions

 

Product Number

Product Description

WAI-E1C-4BNC

4-portE1 (circuit emulation) with BNC interface Port Adapter Module

 

0

1

2

3

TX

TX

 

TX

TX

RX

RX

 

RX

RX

CD

CD

 

CD

CD

CES T1

 

 

 

 

Available Versions

 

 

 

 

Product Number

 

Product Description

 

 

WAI-E1C-4RJ48

 

4-portE1 (circuit emulation) withRJ-48interface Port Adapter Module

WAI-T1C-4RJ48

 

4-portT1 (circuit emulation) withRJ-48interface Port Adapter Module

CDS3 Frame Relay Port Adapter

 

 

 

TX

RX

 

POWER/

 

 

 

 

 

TX

 

 

RESET

 

 

 

 

 

RX

 

 

 

 

CD

 

 

 

DS3FR

 

 

 

 

CE1 Frame Relay

 

 

0

 

1

2

 

 

3

PWR

TX

 

TX

 

 

TX

 

TX

RESET

RX

 

RX

 

 

RX

 

RX

 

CD

 

CD

 

 

CD

 

CD

E1 120Ω FR

 

 

 

 

 

 

 

Available Versions

 

 

 

 

 

 

 

Product Number

 

 

 

Product Description

 

 

 

 

C85MS-4E1-4BNC

 

 

 

C8540 4-portChannelized E1 Frame Relay Port Adapter Module

 

 

2-portDS3

 

 

 

 

 

 

 

 

 

TX

0

RX

TX

1

RX

 

 

TX

 

 

TX

 

 

 

 

 

 

 

 

RX

 

-3

 

 

-3

 

RX

DS 3

 

 

DS

 

 

DS

 

 

Available Versions

 

 

 

 

 

 

 

Product Number

 

 

 

Product Description

 

 

 

 

WAI-T3-2BNC

 

 

 

2-portDS3 Port Adapter Module

 

 

 

 

WAI-E3-2BNC

 

 

 

2-portE3 Port Adapter Module

 

 

 

 

4-portDS3

TX

0

RX

 

TX

1

RX

 

TX

2

RX

 

TX

3

RX

 

 

 

 

 

 

 

 

 

TX

 

RX

CD

TX

 

RX

CD

TX

 

RX

CD

TX

 

RX

CD

DS-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available Versions

 

Product Number

Product Description

WAI-T3-4BNC

4-portDS3 Port Adapter Module

WAI-E3-4BNC

4-portE3 Port Adapter Module

Available Versions

 

Product Number

Product Description

C85MS-1DS3-FRBNC

C8540 1-portChannelized DS3 Frame Relay Port Adapter Module

Interface Modules

ATM Router Module

C8510-ARM-64K

STATUS

C8510 ATM Router Module 64K

Gigabit Ethernet

1-port

C85GE-1X-16K

100Mbps Gigabit ETHERNET Module

-SYNC

TX

-LOSS

RX

 

Rx

LINK

RX

-FULL

 

 

 

 

Rx

 

 

Available Versions

 

 

 

Product Number

Product Description

 

 

C8510-ARM-64K

C8510 ATM Router Module 64K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C85GE-1X-16K

C8510 1-portGigabit Ethernet 16K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C85GE-1X-64K

C8510 1-portGigabit Ethernet 64K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast Ethernet

8-port

 

 

 

 

 

 

 

 

C85FE-16T-16K

C8540

16-port10/100 UTP 16K

 

 

 

 

 

 

 

 

C85FE-16T-64K

C8540

16-port10/100 UTP 64K

 

 

 

 

 

 

 

 

 

C85FE-8T-16K

 

 

 

 

 

 

 

 

C85FE-16TACL-16K

C8540 16-port10/100 UTP 16K w/ACL

 

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

C85FE-16TACL-64K

C8540 16-port10/100 UTP 64K w/ACL

 

 

 

 

 

 

 

 

 

C85FE-16F-16K

C8540

16-port100-FXMT-RJ16K

 

 

 

 

 

 

 

 

 

C85FE-16F-64K

C8540

16-port100-FXMT-RJ64K

 

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

C85FE-16FACL-16K

C8540

16-port100-FXMT-RJ16K

10/100 BASE-FX

0

1

2

3

4

5

6

7

 

w/ACL

 

 

 

 

 

 

 

 

 

 

 

FAST ETHERNET MODULE

 

 

 

 

 

 

 

 

C85FE-16FACL-64K

C8540

16-port100-FXMT-RJ64K

 

 

 

 

 

 

 

 

 

C85FE-8T-64K

 

 

 

 

 

 

 

 

 

w/ACL

 

 

 

 

 

 

 

 

 

 

 

 

 

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

100Mbps Tx

 

 

 

 

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

LINK Rx

 

 

 

10/100 Base Tx

0

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAST ETHERNET MODULE

 

 

 

 

 

 

 

 

 

 

 

Distance and Pinout Information

Maximum Transmission Distances

 

 

Max. Distance

Transceiver Speed

Cable Type

Between Stations

 

 

 

10/100-MbpsEthernet

Category 5 UTP

328 feet (100 m)

 

 

 

100-MbpsEthernet

Multimode fiber

1640 feet (500 m)

 

 

 

1000-MbpsEthernet

Multimode fiber

1640 feet (500 m)

 

 

 

1000-MbpsEthernet

Single-modefiber

16404 feet (5 km)

 

 

 

25-MbpsATM

Category 5 UTP

328 feet (100 m)

 

 

 

155-MbpsATM

Single-modefiber, long reach

25 miles (40 km)

 

 

 

155-MbpsATM

Multimode fiber

1.2 miles (2 km)

 

 

 

622-MbpsATM

Single-modefiber

9 miles (15 km)

 

 

 

622-MbpsATM

Single-modefiber, long reach

25 miles (40 km)1

622-MbpsATM

Multimode fiber

1640 feet (500 m)

 

 

 

T1, 1.544-MbpsATM

Category 5 twisted-pair

650 feet (198 m)

 

 

 

E1, 2.048-MbpsATM

Category 5 twisted-pairand FTP (120 ohm)

650 feet (198 m)

 

 

 

E1, 2.048-MbpsATM

Coaxial cable (75 ohm)

650 feet (198 m)

 

 

 

CDS3, 45-Mbps

Coaxial cable

450 feet (137 m)

 

 

 

CE1, 2.048-MbpsATM

Category 5 twisted-pair

650 feet (198 m)

 

 

 

CES T1

Category 5 twisted-pairand FTP

650 feet (198 m)

 

 

 

CES E1

Category 5 twisted-pairand FTP (120 ohm)

820 feet (250 m)

 

 

 

CES E1

Coaxial cable (75 ohm)

650 feet (198 m)

 

 

 

DS3, 45-Mbps

Coaxial cable

450 feet (137 m)

 

 

 

E3, 34-Mbps

Coaxial cable

1299 feet (396 m)

 

 

 

1.If you are attaching a short cable to the 622-Mbpslong-reachport adapter, you must add 10 dB of attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors.

Pinouts to RJ-45Connectors

The 10/100 Mbps Ethernet interface module with unshielded twisted-pair(UTP) ports supportsRJ-45connectors. The following table lists the signals forRJ-45cable connectors.

Pin

Signal

Description

1

RxD+

Receive data +

 

 

 

2

RxD–

Receive data –

 

 

 

3

NC

No connection

 

 

 

4

NC

No connection

 

 

 

5

NC

No connection

 

 

 

6

NC

No connection

 

 

 

7

TxD+

Transmit data +

 

 

 

8

TxD–

Transmit data –

 

 

 

Pinouts to RJ-48cConnectors

The T1, E1, CES T1, and CES E1 port adapters support RJ-48cconnectors. The following table lists the signals forRJ-48cconnectors.

Pin Description

1Receive ring

2Receive tip

3No connection

4Transmit ring

5Transmit tip

6No connection

7No connection

8No connection

Pinout Information

96-PinMolex to 12 UnshieldedRJ-45Connectors

The 25-Mbpsport adapter supports a96-pinMolex to 4 unshieldedRJ-45connectors. The following table lists the signals for the96-pinMolex connector.

Signal

Molex Pin No.

RJ-45Port No.

RJ-45Pin No.

Description

RXA3

1

3

1

Receive data +

 

 

 

 

 

RXB3

2

3

2

Receive data –

 

 

 

 

 

GND

3

NC

NC

No connection

 

 

 

 

 

GND

4

NC

NC

No connection

 

 

 

 

 

TXA3

5

3

7

Transmit data +

 

 

 

 

 

TXB3

6

3

8

Transmit data –

 

 

 

 

 

GND

7

NC

NC

No connection

 

 

 

 

 

GND

8

NC

NC

No connection

 

 

 

 

 

RXA7

9

7

1

Receive data +

 

 

 

 

 

RXB7

10

7

2

Receive data –

 

 

 

 

 

GND

11

NC

NC

No connection

 

 

 

 

 

GND

12

NC

NC

No connection

 

 

 

 

 

TXA7

13

7

7

Transmit data +

 

 

 

 

 

TXB7

14

7

8

Transmit data –

 

 

 

 

 

GND

15

NC

NC

No connection

 

 

 

 

 

GND

16

NC

NC

No connection

 

 

 

 

 

RXA11

17

11

1

Receive data +

 

 

 

 

 

RXB11

18

11

2

Receive data –

 

 

 

 

 

GND

19

NC

NC

No connection

 

 

 

 

 

GND

20

NC

NC

No connection

 

 

 

 

 

TXA11

21

11

7

Transmit data +

 

 

 

 

 

TXB11

22

11

8

Transmit data –

 

 

 

 

 

GND

23

NC

NC

No connection

 

 

 

 

 

GND

24

NC

NC

No connection

 

 

 

 

 

RXA10

25

10

1

Receive data +

 

 

 

 

 

RXB10

26

10

2

Receive data –

 

 

 

 

 

GND

27

NC

NC

No connection

 

 

 

 

 

GND

28

NC

NC

No connection

 

 

 

 

 

TXA10

29

10

7

Transmit data +

 

 

 

 

 

Signal

Molex Pin No.

RJ-45Port No.

RJ-45Pin No.

Description

TXB10

30

10

8

Transmit data –

 

 

 

 

 

GND

31

NC

NC

No connection

 

 

 

 

 

GND

32

NC

NC

No connection

 

 

 

 

 

RXA6

33

6

1

Receive data +

 

 

 

 

 

RXB6

34

6

2

Receive data –

 

 

 

 

 

GND

35

NC

NC

No connection

 

 

 

 

 

GND

36

NC

NC

No connection

 

 

 

 

 

TXA6

37

6

7

Transmit data +

 

 

 

 

 

TXB6

38

6

8

Transmit data –

 

 

 

 

 

GND

39

NC

NC

No connection

 

 

 

 

 

GND

40

NC

NC

No connection

 

 

 

 

 

TXB2

41

2

8

Transmit data –

 

 

 

 

 

TXA2

42

2

7

Transmit data +

 

 

 

 

 

GND

43

NC

NC

No connection

 

 

 

 

 

GND

44

NC

NC

No connection

 

 

 

 

 

RXB2

45

2

2

Receive data –

 

 

 

 

 

RXA2

46

2

1

Receive data +

 

 

 

 

 

GND

47

NC

NC

No connection

 

 

 

 

 

RXA6

48

NC

NC

No connection

 

 

 

 

 

RXA1

49

1

1

Receive data +

 

 

 

 

 

RXB1

50

1

2

Receive data –

 

 

 

 

 

GND

51

NC

NC

No connection

 

 

 

 

 

GND

52

NC

NC

No connection

 

 

 

 

 

TXA1

53

1

7

Transmit data +

 

 

 

 

 

TXB1

54

1

8

Transmit data –

 

 

 

 

 

GND

55

NC

NC

No connection

 

 

 

 

 

GND

56

NC

NC

No connection

 

 

 

 

 

RXA4

57

4

1

Receive data +

 

 

 

 

 

RXB4

58

4

2

Receive data –

 

 

 

 

 

GND

59

NC

NC

No connection

 

 

 

 

 

GND

60

NC

NC

No connection

 

 

 

 

 

TXA4

61

4

7

Transmit data +

 

 

 

 

 

TXB4

62

4

8

Transmit data –

 

 

 

 

 

Signal

Molex Pin No.

RJ-45Port No.

RJ-45Pin No.

Description

GND

63

NC

NC

No connection

 

 

 

 

 

GND

64

NC

NC

No connection

 

 

 

 

 

RXA9

65

9

1

Receive data +

 

 

 

 

 

RXB9

66

9

2

Receive data –

 

 

 

 

 

GND

67

NC

NC

No connection

 

 

 

 

 

GND

68

NC

NC

No connection

 

 

 

 

 

TXA9

69

9

7

Transmit data +

 

 

 

 

 

TXB9

70

9

8

Transmit data –

 

 

 

 

 

GND

71

NC

NC

No connection

 

 

 

 

 

GND

72

NC

NC

No connection

 

 

 

 

 

RXA8

73

8

1

Receive data +

 

 

 

 

 

RXB8

74

8

2

Receive data –

 

 

 

 

 

GND

75

NC

NC

No connection

 

 

 

 

 

GND

76

NC

NC

No connection

 

 

 

 

 

TXA8

77

8

7

Transmit data +

 

 

 

 

 

TXB8

78

8

8

Transmit data –

 

 

 

 

 

GND

79

NC

NC

No connection

 

 

 

 

 

GND

80

NC

NC

No connection

 

 

 

 

 

TXB5

81

5

8

Transmit data –

 

 

 

 

 

TXA5

82

5

7

Transmit data +

 

 

 

 

 

GND

83

NC

NC

No connection

 

 

 

 

 

GND

84

NC

NC

No connection

 

 

 

 

 

RXB5

85

5

2

Receive data –

 

 

 

 

 

RXA5

86

5

1

Receive data +

 

 

 

 

 

GND

87

NC

NC

No connection

 

 

 

 

 

GND

88

NC

NC

No connection

 

 

 

 

 

TXB0

89

0

8

Transmit data –

 

 

 

 

 

TXA0

90

0

7

Transmit data +

 

 

 

 

 

GND

91

NC

NC

No connection

 

 

 

 

 

GND

92

NC

NC

No connection

 

 

 

 

 

Signal

Molex Pin No.

RJ-45Port No.

RJ-45Pin No.

Description

RXB0

93

0

2

Receive data –

 

 

 

 

 

RXA0

94

0

1

Receive data +

 

 

 

 

 

GND

95

NC

NC

No connection

 

 

 

 

 

GND

96

NC

NC

No connection

 

 

 

 

 

MT-RJEthernet Cable Connectors

The Ethernet ports on the 100BASE-FXinterface module areMT-RJreceptacles. The following table lists the signals for theMT-RJEthernet cable connector.

Pin

Signal

Direction

Description

1

VeeRX

Receiver signal ground

 

 

 

 

2

VccRX

<—

Receive power supply

 

 

 

 

3

SD

Signal Detect

 

 

 

 

4

RD-

<—

Receiver data-

 

 

 

 

5

RD+

<—

Receiver data+

 

 

 

 

6

VccTX

—>

Transmit power supply

 

 

 

 

7

VeeTX

—>

Transmit signal ground

 

 

 

 

8

Tdis

Transmit disable

 

 

 

 

9

TD+

—>

Transmit data+

 

 

 

 

10

TD-

—>

Transmit data-

 

 

 

 

Specifications and Regulatory Compliance Information

Description

Specifications

Switch and processor

10-Gbpsshared memory, nonblocking switch fabric up to32-KB

capacity

frames

 

 

 

Dimensions (H x W x D)

Chassis: 10.4 x 17.25 x 18.4 in (26.4 x 43.8 x 46.7 cm)

 

Processor, switch processor, carrier module, and interface module:

 

1.2 x 14.4 x 16 in (3.0 x 36.6 x 40.6 cm)

 

Port adapter: 1.2 x 6.5 x 10 in (3.0 x 16.5 x 25.4 cm)

 

Power supply: 2.7 x 6.0 x 15.3 in (6.9 x 15.2 x 38.9 cm)

 

 

Weight

Empty chassis: 32 lb (14.51 kg)

 

Fully populated chassis: approximately 130 lb (58.97 kg)

 

AC power supply: 11 lb (4.99 kg)

 

DC power supply: 10 lb (4.54 kg)

 

 

Airflow

95 cfm through the system fan assembly

 

 

Operating temperature

32 to 122°F (0 to 50°C)

 

 

Nonoperating temperature

40to 167°F(40to 75°C)

 

 

Humidity

10 to 90%, noncondensing

 

 

Altitude

500to 6,500 ft(152to 2000 m)

 

 

Microprocessor

100-MhzMIPS R4700

 

 

AC total output

388W maximum

 

 

AC-inputvoltage

100-127/200-240VAC wide input with power factor correction

 

 

AC frequency

Auto sensing limits: 100 to 127/200 to 240 VAC, 8/4A, 50/60 Hz

 

 

AC current rating

8/4A with the chassis fully populated

 

 

Power supply load

376W maximum configuration, 200W typical with max configuration

 

 

 

DC voltages supplied and

System:

+5V @ 70A

steady-statemaximum

 

+12V @ 2A

current ratings

 

+24V @ 0.12A

 

Processor:

+5V @ 15A

 

 

+24V @ 25mA

 

 

+12V @ 500mA

 

 

 

Description

Specifications

Memory

8-MBFlash memory SIMM (upgradable to 16 MB)

 

64-MBDRAM

 

256-KBboot EPROM

 

128-KBSRAM

 

No Flash PC card installed by default (accepts 8-,16-,or20-MBIntel

 

Series 2+ Flash PC cards)

 

 

Regulatory Compliance

CE Marking (European Union)1

 

UL 1950 (U.S.A.)

 

CSA C22.2 No. 950 (Canada)

 

EN60950 (European Union)

 

IEC60950 (International)

 

AS/NZS 3260 (Australia/New Zealand)

 

TS001 (Australia)

 

21CFR1040 (Laser - U.S.A.)

 

EN60825 (Laser - European Union)

 

IEC60825 (Laser - International)

 

FCC Part 15 (CFR 47) Class A (U.S.A.)

 

VCCI Class A with UTP and Class B with FTP cables (Japan)

 

EN55022 Class A with UTP and Class B with FTP cables (European

 

Union)

 

CISPR 22 Class A with UTP and Class B with FTP cables

 

(International)

 

AS/NZS 3548 Class A with UTP and Class B with FTP cables

 

(Australia/New Zealand)

 

EH 55024

 

EH 50082-1

 

ET5300 386-2

 

ICES 003 Class A

 

 

1.Products bear CE Marking indicating compliance with the 99/5/EC directive, which includes the following safety and EMC standards.

Product Documentation

Corporate Headquarters

 

 

 

 

 

European Headquarters

Americas Headquarters

Asia Pacific Headquarters

Cisco Systems, Inc.

Cisco Systems Europe

Cisco Systems, Inc.

Cisco Systems Australia, Pty., Ltd

170 West Tasman Drive

11, Rue Camille Desmoulins

170 West Tasman Drive

Level 9, 80 Pacific Highway

San Jose, CA 95134-1706

92782 Issy-les-Moulineaux

San Jose, CA 95134-1706

P.O. Box 469

USA

 

Cedex 9

USA

North Sydney

www.cisco.com

France

www.cisco.com

NSW 2060 Australia

Tel:

408 526-4000

www-europe.cisco.com

Tel: 408 526-7660

www.cisco.com

 

800 553-NETS(6387)

Tel: 33 1 58 04 60 00

Fax: 408 527-0883

Tel: +61 2 8448 7100

Fax:

408 526-4100

Fax: 33 1 58 04 61 00

 

 

Fax: +61 2 9957 4350

 

Cisco Systems has more than 200 offices in the following countries and regions. Addresses, phone numbers, and fax numbers are listed on the

 

 

C i s c o W e b s i t e a t w w w . c i s c o . c o m / g o / o f f i c e s

 

Argentina • Australia • Austria • Belgium • Brazil • Bulgaria • Canada • Chile • China PRC •

Colombia • Costa Rica • Croatia

Czech Republic • Denmark • Dubai, UAE • Finland • France • Germany • Greece • Hong Kong SAR • Hungary • India • Indonesia

Ireland • Israel • Italy • Japan

• Korea • Luxembourg • Malaysia

• Mexico • The Netherlands

• New Zealand • Norway • Peru

Philippines • Poland • Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Scotland • Singapore • Slovakia • Slovenia • South Africa Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • Ukraine • United Kingdom • United States • Venezuela • Vietnam • Zimbabwe

Copyright © 2001, Cisco Systems, Inc. All rights reserved. Printed in the USA. AccessPath, AtmDirector, Browse with Me, CCDE, CCIP, CCSI, CD-PAC,CiscoLink, the Cisco NetWorks logo, the CiscoPowered Network logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, Fast Step, Follow Me Browsing, FormShare, FrameShare, GigaStack, IGX, Internet Quotient, IP/VC, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ logo, iQ Net Readiness Scorecard, MGX, the Networkers logo,Packet, RateMUX, ScriptBuilder, ScriptShare, SlideCast, SMARTnet, TransPath, Unity, Voice LAN, Wavelength Router, and WebViewer are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That’s Possible, and Empowering the Internet Generation, are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastSwitch, IOS, IP/TV, LightStream, MICA, Network Registrar, PIX,Post-Routing,Pre-Routing,Registrar, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.

All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0105R)

DOC-7810519=78-10519-03

Catalyst 8510 CSR Documentation http://www.cisco.com/univercd/cc/td/doc/product/l3sw/8510/index.htm

Catalyst 8510 MSR Documentation http://www.cisco.com/univercd/cc/td/doc/product/atm/c8510/index.htm

LightStream 1010 Documentation http://www.cisco.com/univercd/cc/td/doc/product/atm/ls1010s/index.htm

Related Web Pages

Catalyst 8500 Series http://www.cisco.com/warp/public/cc/pd/si/casi/ca8500/index.shtml

LightStream 1010 ATM Switches http://www.cisco.com/warp/public/cc/pd/si/lsatsi/ls1010

Layer 3 Backbone http://www.cisco.com/warp/public/779/largeent/design/L3_backbone.html

Catalyst 8510 CSR Software

(requires CCO authorization) http://www.cisco.com/cgi-bin/tablebuild.pl/cat8510c

Catalyst 8510 MSR Software

(requires CCO authorization) http://www.cisco.com/cgi-bin/tablebuild.pl/cat8510m

LightStream 1010 Software

(requires CCO authorization) http://http://www.cisco.com/cgi-bin/tablebuild.pl/ls1010

Cisco Interactive Quick Start Guides

http://www.cisco.com/mm/quickstart/