Notice

NOTICE

Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

In no event shall Cabletron Systems be liable for any incidental, indirect, special, or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this manual or the information contained in it, even if Cabletron Systems has been advised of, known, or should have known, the possibility of such damages.

© Copyright February 1996 by:

Cabletron Systems, Inc.,

35 Industrial Way

Rochester, NH 03867-0505

All Rights Reserved

Printed in the United States of America

Order Number: 9031672-01

LANVIEW is a registered trademark of Cabletron Systems, Inc.

MMAC andMMAC SmartSWITCH are registered trademarks of Cabletron Systems, Inc.

Ethernet is a trademark of Xerox Corp.

CompuServe is a registered trademark of CompuServe, Inc.

i

Notice

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

DOC NOTICE

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

ii

Notice

VCCI NOTICE

This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.

Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.

Read the instructions for correct handling.

iii

CONTENTS

CHAPTER 1 INTRODUCTION

1.1

USING THIS MANUAL .........................................................................

1-1

1.2

THE 7F06-02 MODULE...........................................................................

1-2

 

1.2.1 Cable Type and FPIMs ..................................................................

1-2

 

1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch

 

and the 7C04-R Workgroup SmartSwitch ..................................

1-3

1.3

FEATURES ................................................................................................

1-4

 

1.3.1 FPIMs...............................................................................................

1-4

 

1.3.2 LANVIEW LEDs ............................................................................

1-4

 

1.3.3 Connectivity....................................................................................

1-4

1.4

RELATED MANUALS ............................................................................

1-5

1.5

GETTING HELP.......................................................................................

1-5

CHAPTER 2 NETWORK REQUIREMENTS

2.1 FPIM MODULE SPECIFICATIONS......................................................

2-1

2.1.1 FPIM-00 and FPIM-01 ...................................................................

2-1

2.1.2 FPIM-02 and FPIM-04 ...................................................................

2-3

2.1.3 FPIM-05 and FPIM-07 ...................................................................

2-4

CHAPTER 3 INSTALLATION/REMOVAL

3.1

UNPACKING THE 7F06-2 MODULE...................................................

3-1

3.2

INSTALLING FPIMS...............................................................................

3-1

3.3

INSTALLING/REMOVING THE 7F06-02 MODULE.......................

3-2

 

3.3.1 Installing in the 7C03 SmartSwitch .............................................

3-2

 

3.3.2 Removing from the7C03 SmartSwitch........................................

3-3

 

3.3.3 Installing in the 7C04 or 7C04-R Workgroup SmartSwitch .....

3-5

 

3.3.4 Removing from the 7C04 or 7C04-R Workgroup SmartSwitch.3-

 

7

 

CHAPTER 4 TROUBLESHOOTING

CHAPTER 5 TECHNICAL SPECIFICATIONS

5.1

STANDARDS............................................................................................

5-1

5.2

EMI.............................................................................................................

5-1

5.3

EMC ...........................................................................................................

5-1

5.4

NETWORK INTERFACES......................................................................

5-1

5.5

SAFETY......................................................................................................

5-2

5.6

SERVICE ....................................................................................................

5-2

v

Contents

5.7 PHYSICAL ................................................................................................

5-2

5.7.1

Dimensions .....................................................................................

5-2

5.7.2

Weight..............................................................................................

5-2

vi

CHAPTER 1

INTRODUCTION

Welcome to Cabletron Systems 7F06-02FDDI SmartSwitch Interface Module User’s Guide. This guide is a simple reference for installing and using the 7F06-02 Module. Before installing this module, you should carefully read through this manual to gain a full understanding of its capabilities.

The 7F06-02Module is a two port FDDI module. This module connects to a network and the 7X00 SmartSwitch™ Control Module in the 7C03,7C04 or7C04-RMMAC SmartSwitch via a SmartSwitch bus.

1.1 USING THIS MANUAL

Chapter 1, Introduction, discusses the capabilities and special features of Cabletron Systems7F06-02Module. This chapter also includes a list of related manuals.

Chapter 2, Network Requirements, contains a list of available FPIMs and the network requirements that should be considered before installing the7F06-02Module.

Chapter 3, Installation/Removal, contains instructions for installing and removing the7F06-02in the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the7C04-RWorkgroup SmartSwitch.

Chapter 4, Troubleshooting, contains instructions for using LANVIEW® (Cabletron Systemsbuilt-indiagnostic and status monitoring system).

Chapter 5, Technical Specifications, provides detailed information about the physical characteristics of the7F06-02Module.

1-1

INTRODUCTION

1.2 THE 7F06-02MODULE

The 7F06-02Module provides two Fiber Optic ports via front panel FPIM modules.

1.2.1 Cable Type and FPIMs

The 7F06-02module has two front panel connectors that interface to the 7X00 Smart Switch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs. There are two FPIMs for each channel. These FPIMs allow the use of single mode or multimode fiber cable with MIC or SC type connectors and twisted pair cable, either shielded or unshielded.

1-2

INTRODUCTION

7F06-02

SP

A

F

D

SN

 

D

P

A

I

S

B

1

 

 

 

 

B

A

F

D

D PA SB

I

2

B

Figure 1-1.7F06-02Module

1.2.27C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-RWorkgroup SmartSwitch

The 7F06-02Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the7C04-RWorkgroup SmartSwitch.

The modular design of the 7C03 MMAC SmartSwitch allows other modules that support Ethernet, Fast Ethernet, ATM, FDDI, or

1-3

INTRODUCTION

Token Ring to be used with the 7F06-02Module. These modules provide the capability to share data without the use of external bridges or routers.

The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis. The 7C04 Workgroup SmartSwitch and the 7C04-RWorkgroup SmartSwitch are standalone chassis that provide the same functions.

1.3 FEATURES

The 7F06-02Module provides two FDDI ports via front panel FPIMs. The7F06-02Module includes the following features:

1.3.1 FPIMs

The front panel connections are standard Cabletron FPIMs. These FPIMs allow the use of single mode or multimode fiber cable with MIC or SC type connectors.

1.3.2 LANVIEW LEDs

The 7F06-02uses LANVIEW, Cabletron Systemsbuilt-invisual diagnostic and status monitoring system. With LANVIEW LEDs, you can quickly identify, at a glance, the status of the device connected to a port on the7F06-02Module.

1.3.3 Connectivity

The 7F06-02Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection provides power to the7F06-02Module and a channel for communication with the 7X00 SmartSwitch Control Module. The two front panel FPIMs provide FDDI connections, allowing the use of single mode or multimode fiber cable with MIC or SC type connectors.

1-4