Cabletron Systems 6A000-ZX-250 User Manual
Size:
1.27 Mb
Download

Console Commands

SwitchConfig

Use SwitchConfig (switch configuration) to manage switch-relatedparameters, like switchname and IP address.

SERVER SVC

X X

Operators

modify, show

Parameters

Input Parameter

Description

Value/Field Size

Default

 

 

 

 

[SwitchName]

Name of the switch.

1-19characters

switch_1

[IPAddress]

IP address of Ethernet port on the switch.

dot decimal/

1.1.1.200

 

 

7-15characters

 

[IPNetMask]

IP netmask of the client. Defaults to the

dot decimal/

255.0.0.0,

 

appropriate netmask, based on IP address

7-15characters

255.255.0.0 or

 

class. Calculated from the first two high

 

255.255.255.0

 

bits of the IP address. Must be specified

 

 

 

only if IP subnets are being used.

 

 

Output Parameter

Description

Value/Field Size

 

 

 

[CPU Model]

Model of the i960 CPU.

Up to 7 characters

[CPUSpeed]

Speed of the CPU.

25 (CA) - 33 (CF) MHz

[CPU Board ID]

Hardware version level of the CPU

1 character

 

board.

 

[Secondary Flash Type]

Type of secondary flash.

ASYNCHRONOUS, SYNCHRONOUS

[CPU DRAM]

CPU DRAM memory size.

megabytes/Up to 4 characters

2-184SmartCell6A000/ZX-250Reference Manual

Console Commands

Output Parameter

Description

Value/Field Size

 

 

 

[Common DRAM]

Common DRAM memory size.

megabytes/Up to 4 characters

[SAR Control SRAM]

SAR control memory size.

kilobytes/Up to 5 characters

Power Mode

Type of power modules used by the

Redundant, Non-Redundant

 

switch

 

[Number of Switch

Number of switch boards on the system.

1, 2

Boards]

 

 

[Switch Board 1 ID]

Revision number of Board 1.

kilobytes/1-16

[Switch Board 2 ID]

Revision number of Board 2.

kilobytes/1-16

[Cell Memory Size]

Total cell buffer size.

bytes

[Number of Quad

Number of quad boards on the system.

1, 2, 3, 4.../

Boards]

 

n/a

[Number of Ports]

Number of installed ports, less CPU (for

1, 2, 3, 4.../

 

example, if 8 ports are installed, 7 ports

n/a

 

are listed). One port (B4) is reserved for

 

 

CPU.

 

[Quad Board Type]

Bandwidth of ports on each installed I/O

155 Mbps, 622 Mbps

 

module. Bandwidth used to distinguish

 

 

between four port (155 Mbps) and single

 

 

port boards (622 Mbps).

 

[IP Address]

IP address of the switch.

0.0.0.0 - 255.255.255.255

[MAC Address (Base)]

Base MAC (media access control)

00:20:d4:XX:XX:XX

 

address for the board. There are 128

 

 

addresses, starting at this base address.

 

 

The first is used for the Ethernet port.

 

 

The ATM stack uses all the addresses

 

 

(including the first).

 

[Switch Software Type]

Type of switch software package.

SVC, Server

[Software Version]

Version of the software.

X.X

[Build Number]

The build number for this version of

XX

 

switch software.

 

SmartCell 6A000/ZX-250Reference Manual2-185

Console Commands

Output Parameter

Description

Value/Field Size

 

 

 

[Build Date]

The date which the code was loaded on

day/month/date/ hr:min:sec year

 

the switch.

 

[Software Image Size]

Binary image size.

bytes

[Heap Space

Total heap space used, total memory

bytes/bytes/%

Used/Total/%Free]

allocated to heap, and percent of free

 

 

memory.

 

2-186SmartCell6A000/ZX-250Reference Manual

Console Commands

Descriptions

Operator

Parameters/Permissions

Description

 

 

 

modify [SwitchName] <switchname> switchconfig[IPAddress] <ipaddress>

[IPNetMask] <ipnetmask>

Administrator

Runs automatically when you first configure the switch, then prompts you for the required input. Enter modify switchconfig if you want to change any of the above parameters after the initial switch configuration. Unless you are experienced with configuring IP subnets, it is recommended that you accept the IP netmask default.

show All switchconfig

Displays hardware and software configuration information about the switch. It also includes auto-detecthardware configuration information, such as number of switch boards and memory, and software information such as the type and version. Any future hardware or software changes will be detected automatically when the switch is rebooted.

Examples

switch_prompt

# modify switchconfig

 

SwitchName(switch_1)

: switch_2

IPAddress(200.30.72.122)

: 1.1.1.202

IPNetMask(255.255.255.0)

: 255.255.255.128

switch_prompt

#

 

switch_prompt # show switchconfig

Switch Configuration

==============================================================================

Switch Name

:switch 1

CPU Model

: i960 CX

CPU Speed

: 33 MHz

CPU Board ID

: 2

Secondary Flash Type

: Asynchronous

CPU DRAM

: 8 MB

Common DRAM

: 8 MB

SAR Control SRAM

: 128 KB

Power Mode

: Non-Redundant

Number of Switch Boards

: 1

Switch Board 1 ID

: 5

Cell Memory Size

: 32768 cells

Switch Configuration

 

Number of Quad Boards

: 2

Number of Ports

: 4

Quad Board A Type

: 622 MBps

Quad Board B Type

: 155 MBps

IP Address

: 204.95.77.254

MAC Address (Base)

: 00:20:D4:14:41:80

Switch Software Type

: Server

Software Version

: 1.2RQA

Build Number

: 9

Build Date

: Tue Sep 23 16:39:36 PDT 1997

Software Image Size

: 2676256 bytes

Heap Space (Used/Total/%Free)

: 2473888/5712288/56.69%

switch_prompt #

 