SSCOPConfig

Use SSCOPConfig (service-specificconnection-orientedprotocol configuration) to view timers and other parameter values.

SERVER SVC

X X

Operator

show

Parameters

Parameter

Description

Value/Field Size

Default

 

 

 

 

[Port#]

Port number on the switch.

ALL, A1...A4, B1...B3,

ALL

 

 

C1...C4, D1...D4

 

[MaxPD]

Number of SD (switching delay) PDUs (protocol data

5-20

10

 

unit) after which a poll PDU is generated.

 

 

[MaxCC]

Number of begin PDUs sent during line establishment.

4-10

4

[PollTm]

Time between generation of PDUs.

m/seconds/

200

 

 

100-200

 

[KpAliveTm]

Controls poll exchange rate in the absence of SD PDU

m/seconds/

1000

 

traffic.

1000-2000/

 

[NoRespTm]

Maximum time within which a poll has to be

m/seconds/

10000

 

acknowledged by a PDU.

10000-15000

 

[CCTm]

Rate at which begin and end PDUs are generated.

m/seconds/

1000

 

 

1000-2000

 

[TxWindowSz]

Setting of transmit direction window size.

32-256

256

[RxWindowSz]

Setting of receive window size.

32-256

256

SmartCell 6A000/ZX-250Reference Manual2-175

Console Commands

Description

Operator

Parameters/Permissions

Description

 

 

 

show

[PortNumber] <portnumber>

Displays the SSCOP configuration control parameters.

sscopconfig

All

 

 

 

Examples

switch_prompt #

show sscopconfig

 

PortNumber(ALL)

: A1

 

Port# MaxPD MaxCC PollTm KpAliveTm NoRespTm CCTm

TxWindowSz RxWindowSz

===========================================================================

A1

15

5

250

1500

15000

1500

256

256

switch_prompt #

show sscopconfig /d

 

 

 

 

PortNumber(ALL)

 

 

 

 

:

 

 

Port#

MaxPD MaxCC PollTm

KpAliveTm NoRespTm CCTm

TxWindowSz RxWindowSz

===========================================================================

A1

15

5

250

1500

15000

1500

256

256

A2

10

4

500

1000

30000

1000

256

256

A3

10

4

500

1000

30000

1000

256

256

A4

10

4

500

1000

30000

1000

256

256

B1

10

4

500

1000

30000

1000

256

256

B2

10

4

500

1000

30000

1000

256

256

B3

10

4

500

1000

30000

1000

256

256

B4

10

4

500

1000

30000

1000

256

256

switch_prompt #