Cabletron Systems 6A000-ZX-250 User Manual
Size:
1.27 Mb
Download

Console Commands

PortAutoDetect

Use PortAutoDetect to manage the automatic-detectionfeatures of the switch on an individual port basis.

SERVER

SVC

X

X

Operators modify, show

Parameters

Input Parameter

Description

Value/Field Size

Default

 

 

 

 

[AutoDetectType]

Signaling type auto-detectioncapability of the

sigtype, vpivcibits,

ALL

 

port.

ALL

 

[PortNumber]

Port number on the switch.

ALL, A1...A4, B1...

ALL

 

 

B3, C1...C4, D1...D4

 

[Value]

Status of auto-detectionflag.

on/off

on

Output Parameter

Description

 

 

[AutoDetectSigType]

Current setting of the auto-detectionflag for signaling type.

[AutoDetectVpiVciBits]

Current setting of the auto-detectionflag for VPI and VCI bits.

2-130SmartCell6A000/ZX-250Reference Manual

Console Commands

Descriptions

Operator

Parameters/Permissions

Description

 

 

 

modify [AutoDetectType]portautodetec <signalingtype>

t[PortNumber] <portnumber> [Value] <value>

Administrator

Modifies the flag settings that control auto-detectionof signaling type and VPI and VCI bits. This function can be enabled or disabled for each port, but signaling type and VPI and VCI bits are default enabled. You should disableauto-detectionif the device at the other end does not supportauto-detection(for example, if the other device is a PVC switch.)

show

[AutoDetectType]

portautodetec

<signalingtype>

t

[PortNumber] <portnumber>

 

All

Examples

Displays the current flag settings that control the auto-detectionof signaling type and VPI and VCI bits.

switch_prompt #

modify portautodetect

 

AutoDetectType(ALL)

: sigtype

PortNumber(ALL)

 

: a1

Value(on)

 

: off

switch_prompt #

 

 

switch_prompt #

show portautodetect

 

AutoDetectType(ALL)

:

PortNumber(ALL)

 

:

PortNumber

AutoDetectSigType

AutoDetectVpiVciBits

===========================================================================

A1

off

on

A2

on

on

A3

on

on

A4

on

on

B1

on

on

B2

on

on

B3

on

on

switch_prompt #

 

 

SmartCell 6A000/ZX-250Reference Manual2-131