LogAlarmMask

Use LogAlarmMask to determine—bysetting maskingflags—whichlog messages generate alarms.

SERVER SVC

X X

Operators

modify, show

Parameters

For more options see [FilterFlags] input parameter under “LogTrace”.

Parameter

Description

Value/Field Size

Default

 

 

 

 

[Emergency]

Emergency class flag set.

y/n

n

[Alert]

Alert class flag set.

y/n

n

[Critical]

Critical class flag set.

y/n

n

[Error]

Error class flag set.

y/n

n

[Warning]

Warning class flag set.

y/n

n

[Notice]

Notice class flag set.

y/n

n

[Info]

Information class flag set.

y/n

n

[Debug]

Debug class flag set.

y/n

n

[Trace]

Trace class flag set.

y/n

n

[ALARM]

Alarm class flag set.

y/n

n

2-104SmartCell6A000/ZX-250Reference Manual

Console Commands

Descriptions

Operator

Parameters/Permissions

Description

 

 

 

modify Emergency] <y/n>

logalarmmask [Alert] <y/n>

[Critical] <y/n>

[Error] <y/n>

[Warning] <y/n>

[Notice] <y/n>

[Info] <y/n>

[Debug] <y/n>

[Trace] <y/n>

[ALARM] <y/n>

Controls which log messages are accepted into the alarm message buffer. The log alarm mask enables you to specify which alarms you want in the alarm message buffer by typing y orn at the relevant parameter field.

 

Administrator

 

show

All

Displays the current settings of the flags within the alarm

logalarmmask

 

message buffer. If no flags are on, all log messages are

 

 

accepted into the alarm message buffer. If one flag is on, only

 

 

those log messages that have the flag set are accepted into the

 

 

alarm message buffer. You can “ell if a particular masking

 

 

flag is active or not by whether “ON” or “OFF” is visible next

 

 

to it.

Examples

switch_prompt # modify logalarmmask

Emergency(n):y

Alert(n) :

Critical(n) :

Error(n) :

Warning(n) :y

Notice(n) :

Info(n) :

Debug(n) :

Trace(n) :

ALARM(n) : switch_prompt #

switch_prompt # show logalarmmask

SwitchNameFlags generating alarms for following log types

-----------------------------------------------

Emergency Flag

: ON

Alert Flag

: OFF

Critical Flag

: OFF

Error Flag

: OFF

Warning Flag

: ON

Notice Flag

: OFF

Info Flag

: OFF

Debug Flag

: OFF

Trace Flag

: OFF

Alarm Flag

: OFF

switch_prompt #

 