Cabletron Systems 6A000-ZX-250 User Manual
Size:
1.27 Mb
Download

Console Commands

LECSELAN

Use LECSELAN (LAN emulation configuration server emulated LAN) to manage the LECS entries on the ELAN.

SERVER SVC

X

Operators

add, delete, modify, show

Parameters

Parameter

Description

Value/Field Size

Default

 

 

 

 

[ELANNumber]

Number of the ELAN to which LECS belongs.

0 - 127

0

[ELANName]

Name of ELAN to which LECS belongs.

Up to 32 characters

ELAN000

[LESAddress]

LES address of the ELAN to which LECS belongs.

13-20bytehex-based/

NONE

 

 

59 characters

 

[ELANType]

The data-linktype used by the ELAN.

802.3 (Ethernet)

802.3

 

 

802.5 (TokenRing)

 

[MTU]

Maximum transfer unit for the clients joining this

1516 or 9234 (Ethernet)

1516 or 4544

 

ELAN.

4544 (Token Ring)

 

[TLVSet]

The TLV (type, length, and value) set number (set of

1-32767

n/a

 

TLV parameters) corresponding to the members

 

 

 

joining this ELAN.

 

 

2-72SmartCell6A000/ZX-250Reference Manual

add buselan, add

Console Commands

Descriptions

Operator

Parameters/Permissions

Description

 

 

 

add [ELANNumber] <elannumber> lecselan[ELANName] <elanname>

[LESAddress] <lesatmaddress>

[ELANType] <elantype>

[MTU] <maxframesize>

[TLVSet] <tlvsetid>

Administrator

delete [ELANNumber] <elannumber>

lecselan

Administrator

modify [ELANNumber] <elannumber> lecselan[ELANName] <elanname>

[LESAddress] <lesatmaddress>

[ELANType] <elantype>

[MTU] <maxframesize>

[TLVSet] <tlvsetid>

Administrator

Creates a specified ELAN on the LECS. Enter add lecselan to add an ELAN the longway—withthe

leselan, and add lecselancommands. Enter show elan

before this command to display the LES address to be added to the LECS.

Removes an existing ELAN from the LECS.

Modifies the parameters of a specified ELAN on the LECS by deleting and then recreating the ELAN. Enter modify lecselan if you are moving an ELAN and have a new LES and BUS ATM address to assign to the ELAN, or if you want to change the ELAN type. The [ElanNumber] parameter is the key field for finding the correct ELAN.

show

[ELANNumber] <elannumber>

Displays a specified ELAN configuration on the LECS.

lecselan

All

 

 

 

Examples

switch_prompt #

add lecselan

 

ELANNumber(0)

 

: 4

ELANName(ELAN004)

:

LESAddress(39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:04:02):

ELANType(802.3)

 

:

MTU(1516)

 

:

TLVSet()

 

:

switch_prompt #

 

 

switch_prompt #

delete lecselan

 

ELANNumber(0)

 

: 4

ELAN 4 Configured on LECS

============================================================================

ELAN Number

: 4

ELAN Name

: ELAN004

LES Address

: 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:04:02

ELAN Type

: 802.3

MTU

: 1516

Confirm(y/n)?:y

 

switch_prompt #

 

SmartCell 6A000/ZX-250Reference Manual2-73

Console Commands

switch_prompt # modify lecselan

 

ELANNumber(0)

:

ELANName(elan1)

:

LESAddress(39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:02):

39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:04

ELANType(802.3)

:

MTU(1516)

:

TLVSet()

:

switch_prompt #

 

switch_prompt #

show lecselan

ELANNumber(ALL)

:

All the ELANs Configured on the LECS

============================================================================

ELAN Number

: 0

ELAN Name

: elan1

LES Address

: 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:04

ELAN Type

: 802.3

MTU

: 1516

switch_prompt #

 

2-74SmartCell6A000/ZX-250Reference Manual