Cabletron Systems 6A000-ZX-250 User Manual
Size:
1.27 Mb
Download

Console Commands

IPATMClient

Use IPATMClient (IP over (/) ATM client) to manipulate either local IP/ATM clients or IP/ATM clients acting as an IP/ATM server, or if you want to configure an IP/ATM client on the IP/ATM server itself.

SERVER SVC

X X

Operators

add, modify, (show client)

SmartCell 6A000/ZX-250Reference Manual2-57

Console Commands

Parameters

Input Parameter

Description

Value/Field Size

Default

 

 

 

 

[ClientNumber]

Number of the client.

0-127

ALL

[ServerType]

IP/ATM server type.

LOCAL,

NONE

 

 

EXTERNAL, NONE

 

[ServerAddress]

ATM address of the IP/ATM server. If

13-20bytehex-based/

NONE

 

[ServerType]states NONE or LOCAL, then

Up to 59 characters

 

 

accept the default. LOCAL means the client

 

 

 

also acts as an IP/ATM server for that VLAN

 

 

 

(virtual LAN). If [ServerType]states

 

 

 

EXTERNAL, enter the ATM address of the

 

 

 

external server.

 

 

[IPAddress]

IP address of the client.

dot decimal/

NONE

 

 

7-15characters

 

[NetMask]

IP netmask of the client. This parameter defaults

dot decimal/

255.0.0.0,

 

to the appropriate netmask, based on the class of

7-15characters

255.255.0.0 or

 

IP address. Must be specified only if IP subnets

 

255.255.255.0

 

are being used. Calculated from the first two

 

 

 

high bits of the IP address, so it is either

 

 

 

255.0.0.0, 255.255.0.0, or 255.255.255.0. With

 

 

 

less address left, you have fewer bits to use to

 

 

 

define subnets.

 

 

[MTU]

Maximum transfer unit assigned for this client.

64 to 10160

9180

2-58SmartCell6A000/ZX-250Reference Manual

Console Commands

Descriptions

Operator

Parameters/Permissions

Description

 

 

 

add [ClientNumber] <clientnumber> ipatmclient[ServerType] <servertype>

[ServerAddress]

<serveraddress>

[IPAddress] <ipaddress>

[NetMask] <netmask>

[MTU] <maxtransferunit>

Administrator

modify [ClientNumber] <clientnumber> ipatmclient[ServerType] <servertype>

[ServerAddress]

<serveraddress>

[IPAddress] <ipaddress>

[NetMask] <netmask>

[MTU] <maxtransferunit>

Administrator

show client [ClientNumber] <clientnumber>

All

Creates a new IP/ATM client to the switch. If the circuits in this VLAN (virtual LAN) are SVCs, (switched virtual circuits) and you want to use this client as the ARP server, enter local for the server type. If you do not want to use this client as the ARP server, enterexternal as the server type, and use the address of any configured ARP server as the server address. If adding an IP/ATM client in aPVC-onlyenvironment, enternone for the server type.

Modifies an existing local IP/ATM client on the switch.

Displays all or specified clients on the switch. Enter show client to establish the activity of all the different client types on the switch. See “Client” for details.

Examples

switch_prompt #

add

ipatmclient

ClientNumber(0)

 

:

50

ServerType(NONE)

 

: local

ServerAddr()

 

:

 

IpAddr()

 

: 101.1.1.50

NetMask(255.0.0.0):

 

MTU(9180)

 

:

 

switch_prompt #

 

 

 

switch_prompt #

add

ipatmclient

ClientNumber(0)

:

1

 

ServerType(NONE): external

ServerAddress()

:39:00:00:00:00:00:00:00:20:D4:14:2F:00:00:00:0A:01:01:02:00

IPAddress()

: 10.1.1.1

NetMask(255.0.0.0):

 

MTU(9180)

:

 

 

switch_prompt #

 

 

 

switch_prompt #

add

ipatmclient

ClientNumber(0)

 

:

60

ServerType(NONE)

 

:

 

ServerAddr()

 

:

 

IpAddr()

 

: 101.1.1.60

SmartCell 6A000/ZX-250Reference Manual2-59

Console Commands

NetMask(255.0.0.0):

MTU(9180) : switch_prompt #

switch_prompt # modify ipatmclient

ClientNumber(0) : 50

ServerType(LOCAL) :

ServerAddr() :

IpAddr(101.1.1.50): 101.1.1.150

NetMask(255.0.0.0):

MTU(9180) :

switch_prompt # show client

switch_prompt #

2-60SmartCell6A000/ZX-250Reference Manual