Cabletron Systems 6A000-ZX-250 User Manual
Size:
1.27 Mb
Download

Console Commands

ELAN

Use ELAN (emulated local area network) to create or delete ELANs on the switch. This is a quick configuration method of managing ELAN server entries within one command. For details of how to create or delete these entries individually, see “BUSELAN”, “LECSELAN”, and “LESELAN”.

SERVER SVC

X

Operators

add, delete, show

Parameters

Input Parameter

Description

Value/Field Size

Default

 

 

 

 

[ELANNumber]

Number of ELAN to which the BUS (broadcast

0-127

0

 

and unknown server), LECS (LAN emulation

 

 

 

configuration server) or LES (LANE server)

 

 

 

belong.

 

 

[ELANName]

Name of ELAN to which the LES or BUS

Up to 32 characters

ELAN000

 

belongs.

 

 

[ConnectMethod]

Type of connection used.

PVC, SVC

SVC

[ELANType]

Data-linktype used by the ELAN.

802.3 (Ethernet)

802.3

 

 

802.5 (TokenRing)

 

[Multipoint]

Indicates whether control distribute VCC is

YES: VCC is PMP NO:

YES

 

PMP (point-to-multipoint)or PTP

VCC is PTP

 

 

(point-to-point).

 

 

[MTU]

Maximum transfer unit for the clients joining

1516 or 9234 (Ethernet),

1516

 

this ELAN.

4544 (Token Ring)

 

[Distribute]

LES establishes control distribute VCC to all

ALL, PROXY

PROXY

 

the clients if distribute is ALL. If distribute is

 

 

 

PROXY, LES establishes control distribute

 

 

 

VCC only to proxy clients.

 

 

SmartCell 6A000/ZX-250Reference Manual2-41

Console Commands

Output Parameter

Description

 

 

[LES Address]

ATM address of the LANE server.

[Distribute VPI/VCI]

VPI/VCI values of the control direct VCC or multicast send VCC.

[Distribute Method]

Indicates whether the control distribute VCC is established for ALL clients or only

 

PROXY clients.

[LAN Type]

Type of ELAN.

[BUSATMAddress]

ATM address of the BUS (specify when the LES and BUS are not co-located).

Descriptions

Operator

Parameters/Permissions

Description

 

 

 

add elan [ELANNumber] <elannumber>

[ELANName] <elanname>

[ConnectMethod] <connectmethod>

[ELANType] <elantype>

[Multipoint] <distributevcctype>

[MTU] <maximumframesize>

[Distribute]

<controldistributevccoption>

Quickly configures the switch. This command adds the ELAN entry in all three databases (BUSELAN, LESELAN, and LECSELAN) and activates the ELAN.

Administrator

delete elan [ELANNumber] <elannumber>

Administrator

show elan [ELANNumber] <elannumber>

All

Quickly configures the switch. This removes a specific ELAN. This command first checks that all servers (LECS, LES, and BUS) exist before deleting any of them.

Displays an ELAN created by either the quick add elanor the multiple set of commands to add an ELAN. There might not be LECS information (as seen in the first example) if the ELAN was created by add buselan, and add leselanand add lecselanhad not been completed. The LECS information is displayed if you use add elanor if not, after you enter add lecselan(as seen in the following B example below).

2-42SmartCell6A000/ZX-250Reference Manual

Console Commands

Examples

switch_prompt #

add elan

 

ELANNumber(0)

 

: 11

ELANName(ELAN011)

:

ConnectMethod(SVC)

:

ELANType(802.3)

 

:

Multipoint(YES)

 

:

MTU(1516)

 

:

Distribute(PROXY)

:

switch_prompt #

 

 

switch_prompt #

delete elan

 

ELANNumber(0): 11

Confirm(y/n)?: y switch_prompt #

A

switch_prompt # show elan 0

There is no LECS

Record. Retrieving LES Information

ELAN

Number

: 0

ELAN

Name

: ELAN000

LES

Address

: 39:00:00:00:00:00:00:00:20:D4:14:22:80:00:20:D4:14:22:80:02

Max

Frame Size

: 1516

Connection Method : SVC

Distribute VPI/VCI: 0/32

Distribute Method: PROXY

LAN Type

: 802.3

Multipoint

: YES

switch_prompt #

 

SmartCell 6A000/ZX-250Reference Manual2-43

Console Commands

B

switch_prompt # add leselan 4

 

ELANName(ELAN004)

:

ConnectMethod(SVC)

:

ELANType(802.3)

:

Multipoint(YES)

:

MTU(1516)

:

Distribute(PROXY)

:

BUSATMAddress()

:

switch_prompt #

 

switch_prompt # add buselan 4

 

ELANName(ELAN004)

:

ConnectMethod(SVC)

:

ELANType(802.3)

:

Multipoint(YES)

:

MTU(1516)

:

switch_prompt #

 

switch_prompt #

add lecselan 4

 

ELANName(ELAN004)

:

LESAddress(39:00:00:00:00:00:00:00:20:D4:14:22:80:00:20:D4:14:22:84:02):

ELANType(802.3)

 

:

MTU(1516)

 

:

switch_prompt #

 

 

switch_prompt #

show elan 4

 

ELAN 4

 

 

===========================================================================

ELAN Number

: 4

LECS Address

: 39:00:00:00:00:00:00:00:20:D4:14:22:80:00:20:D4:14:22:80:01

LES Address

: 39:00:00:00:00:00:00:00:20:D4:14:22:80:00:20:D4:14:22:84:02

ELAN Name

: ELAN004

ELAN Type

: 802.3

MTU

: 1516

Connection Method: SVC

Distribute VPI/VCI: 0/147

Distribute

Method:

PROXY

Multipoint

:

YES

switch_prompt #