Cabletron Systems 6A000-ZX-250 User Manual
Size:
1.27 Mb
Download

Console Commands

ClientVC

Use ClientVC (client virtual circuit) to view which VCs are associated with a particular local LANE or IP over ATM client's ARP (address resolution protocol) entries. ClientVC is similar to ClientARP, except that it also includes details of VPI/VCI numbers.

SERVER SVC

X X

Operator

show

Parameters

Input Parameter

Description

Value/Field Size

Default

 

 

 

 

[ClientNumber]

Number of the client.

0-127

ALL

Output Parameter

Description

 

 

[MAC Address]

MAC address of the client.

[VPI/VCI]

VPI/VCI (virtual path/channel identifier) values of control direct VCC (virtual channel

 

connection) or multicast send VCC.

[ATM Address]

ATM address of the client.

SmartCell 6A000/ZX-250Reference Manual2-35

Console Commands

Description

Operator

Parameters/Permissions

Description

 

 

 

show [ClientNumber] <clientnumber>

clientvc

All

Displays VC details for local IP/ATM or LANE clients in addition to client ARP mapping details. For IP/ATM, the associated IP address appears, while for LANE, the associated MAC address appears. The associated address is what is located at the other end of the VC.

Example

switch_prompt # show clientvc

ClientNumber(ALL) :

LANE Client 0 VC Table

MAC Address

VPI/VCI

 

ATM Address

===========================================================================

00:02:D4:14:22:80

0/2453

 

39:00:00:00:00:00:00:00:20:D4:14:15:00:00:20:D4:14:22:80:00

IP/ATM Client 50 VC Table

IP Address

VPI/VCI

ATM Address

============================================================================

10.1.1.20/130

39:00:00:00:00:00:00:00:20:D4:14:22:80:00:00:0A:01:01:02:00

switch_prompt #

2-36SmartCell6A000/ZX-250Reference Manual