Bunn CDBCP User Manual

Size:
1.16 Mb
Download

CDBC, CDBCF

CDBCP, CDBCFP

S/N CDBC020213 & up

SINGLE CD, SINGLE CDF

CAUTION

DISCONTINUED VERSION

The information in this manual

is no longer current.

OPERATING & SERVICE MANUAL

BUNN-O-MATICCORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601

FAX: (217) 529-6644

35582.0000C 02/04 ©2003 Bunn-O-MaticCorporation

www.bunnomatic.com

INTRODUCTION

This equipment will automatically brew a half-gallonbatch of coffee into an awaiting decanter at the press of a button. A hot water faucet is included for allied beverage use. Most functions of the brewer are digitally controlled. It is only for indoor use on a sturdy counter or shelf.

CONTENTS

 

Introduction & Warranty ..................................................................................................................

2

User Notices ....................................................................................................................................

3

Electrical & Plumbing Requirements ...............................................................................................

4

Operating Controls...........................................................................................................................

5

Initial Set-Up& Coffee Brewing .......................................................................................................

6

Pour-OverFeature ............................................................................................................................

7

Cleaning ...........................................................................................................................................

7

CDBC, SINGLE CD Adjustments & Optional Settings .......................................................................

8

CDBC, SINGLE CD Water Sensing Threshold Adjustment Procedure ..............................................

9

CDBC, SINGLE CD Pulse Brew Setup Procedure ...........................................................................

10

Troubleshooting .............................................................................................................................

11

Service...........................................................................................................................................

22

Wiring Diagrams ............................................................................................................................

31

BUNN-O-MATICCOMMERCIAL PRODUCT WARRANTY

 

Bunn-O-MaticCorp. (“BUNN”) warrants equipment manufactured by it as follows:

1)All equipment other than as specified below: 2 years parts and 1 year labor.

2)Electronic circuit and/or control boards: parts and labor for 3 years.

3)Compressors on refrigeration equipment: 5 years parts and 1 year labor.

4)Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601or by writing to Post Office Box 3227, Springfield, Illinois62708-3227;2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.

BUNN, CDBC, and CDBCF, CDBCP, CDBCFP, SINGLE CD, and SINGLE CDF are either trademarks or registered trademarks of Bunn-O-MaticCorporation.

Page 2

35582 08263

 

USER NOTICES

Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels.

# 00986.0000

! WARNING

 

DO NOT OVERLOAD CIRCUIT.

ALWAYS ELECTRICALLY GROUND

THE CHASSIS OR ADAPTOR PLUG.

DO NOT DEFORM PLUG OR CORD.

FOLLOW NATIONAL AND LOCAL

ELECTRICAL CODES.

KEEP COMBUSTIBLES AWAY.

FAILURE TO COMPLY RISKS EQUIPMENT

DAMAGE, FIRE OR SHOCK HAZARD.

READ THE ENTIRE

OPERATING MANUAL BEFORE

USING THIS PRODUCT

00986.0000E 5/98 ©1994 Bunn-O-MaticCorporation

#00656.0000

#00658.0000

!

WARNING

 

 

 

DISCARD DECANTER

 

 

 

IF:

 

 

 

° CRACKED

 

 

 

° SCRATCHED

 

 

 

° BOILED DRY

 

 

 

° HEATED WHEN EMPTY

FUNNEL CONTENTS

 

° USED ON HIGH FLAME

 

OR EXPOSED ELECTRIC

ARE HOT

 

 

ELEMENTS

 

 

 

 

READ THE ENTIRE OPERATING MANUAL

BEFORE USING THIS PRODUCT

FAILURE TO COMPLY RISKS INJURY

PN: 00658.0000F 6/98 © 1985 BUNN-O-MATICCORPORATION

# 12364.0000

# 10044.0000

Page 3

35582 041503

 

ELECTRICAL REQUIREMENTS

CAUTION - The brewer must be disconnected from the power source until specified inInitial Set-Up.

Model 15 has an attached cordset and requires2-wiregrounded service rated 120 volts ac, 15 amp, single phase, 60 Hz.

WHITE

 

L2 RED

 

 

NEUTRAL

 

120V.A.C.

120V.A.C.

WHITE

L1 BLACK

208 or 240V.A.C.

 

 

NEUTRAL

 

 

120V.A.C.

 

 

L1 BLACK

Model 20 requires2-wire,grounded service rated 120 volts ac, 20 amp, single phase, 60 Hz. Proceed as follows:

Model 35 requires3-wire,grounded service rated 120/208 or 120/240 volts ac, 20 amp, single phase, 60 Hz. Proceed as follows:

Electrical Hook-Up

CAUTION – Improper electrical installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.Remove the front panel beneath the sprayhead.

4.Feed the cord through the strain relief and connect it to the terminal block.

5.Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Replace the front panel.

6.If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing has been hooked up, the brewer is ready for Initial Set-Up.

PLUMBING REQUIREMENTS

These brewers must be connected to a cold water system with operating pressure between 5 and 90 psi (34.5 and 620 kPa) from a 12" or larger supply line. Ashut-offvalve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is14" flare.Bunn-O-Maticdoes not recommend the use of areverse-osmosisor deionized water supply to this equipment.

NOTE - Bunn-O-Maticrecommends14" copper tubing for installations of less than 25 feet and38" for more than 25 feet from the12" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer to clean the countertop.Bunn-O-Maticdoes not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.

This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA)

and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).

Plumbing Hook-Up

1.Flush the water line.

2.Securely attach it to the flare fitting at the rear of the brewer.

3.Turn on the water supply.

Page 4

35582 091503

 

OPERATING CONTROLS

P1626

(CDBC models)

ON/OFF SWITCH

Pressing the "ON/OFF" switch (indicator glowing) supplies power to the brew station warmer, enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator not glowing) stops tank refilling and brewing and deenergizes the brew station warmer. Stopping a brew cycle after it has been started will not stop the flow of water into the decanter until the funnel is empty.

NOTE – Hot water will be available at the faucet in a limited amount when the "ON/OFF" indicator is not glowing because the tank will not refill.

TEMP

P 2642

(SINGLE CD models)

BREW SWITCH

Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" indicator is glowing.

NOTE – The "ON/OFF" indicator must be glowing to initiate and complete a brew cycle.

BATCH SLECTORS (SINGLE CD only)

Pressing a batch size switch (1/2 gal. or 1 gal.) so the indicator is glowing will set the brewer to deliver the desired brew volume.

ADDITIONAL WARMER SWITCHES (CDBC only)

Pressing any additional warmer switch so that the indicator is glowing, supplies power to the associated warmer.

READY INDICATOR

This indicator glows when the preset temperature has been achieved. The word "NOT" above "READY" will glow in all other instances.

TEMPERATURE INDICATORS

The indicator glows to communicate the brew water temperature setting. Two indicators will glow when the temperature is between them.

Page 5

35582 041503

 

INITIAL SET-UP

1.Insert an empty funnel into the funnel rails.

2.Place an empty decanter under the funnel.

3.Connect the brewer to the power source.

4.Model CDBC – Press the "ON/OFF" switch (indicator glowing).

Model SINGLE CD - Press the "1 gal" switch (indicator glowing) and the "ON/OFF" switch (indicator glowing).

5.Water will flow into the tank and stop when the tank is filled to its capacity.

6.Wait approximately twenty minutes for the water in the tank to heat to the proper temperature.

7.To remove expansion water, place a small vessel beneath the faucet and open the faucet handle. Release it when you hear the tank refilling. If brewer is not equipped with a faucet, place a empty decanter beneath the funnel and initiate a brew cycle.

8.Place an empty decanter/server beneath the funnel and press the "ON/OFF" switch (indicator glowing) then momentarily press and release the "BREW" switch.

9.Allow the cycle to finish and measure the amount of water in the decanter/server. It should be 64 ounces ± 2 for CDBC models and 128 ounces±2 for SINGLE CD models. Refer to the adjustments section of this manual should the volume need to be increased or decreased.

10.Model SINGLE CD only press the "1/2 gal." switch, place an empty server beneath the funnel and press and

release the "BREW" switch. Allow the cycle to finish and measure the amount of water in the server. It should be 64 ounces ± 2. Refer to the adjustments section of this manual should the volume need to be increased or decreased.

The brewer is now ready for use in accordance with the coffee brewing instructions below.

COFFEE BREWING

1.Insert a BUNN® filter into the funnel.

2.Pour fresh coffee grounds into the filter and level the bed of grounds by gently shaking.

3.Slide the funnel into the funnel rails.

4.Place an empty decanter/server beneath the funnel.

5.Model CDBC – Press the "ON/OFF" switch (indicator glowing) then momentarily press and release the "BREW" switch.

Model SINGLE CD - Select 1/2 or 1 Gallon setting then momentarily press and release the "BREW" switch.

6.When brewing is completed, simply discard the grounds and filter.

Page 6

35582 041503

 

POUR-OVERFEATURE

Models CDBCP & CDBCFP

If the brewer is equipped with a pour-overfeature, follow the instructions below.

1.Remove the thumbscrew and pour-inlid from the top cover of the brewer and set aside.

2.Insert a BUNN® filter into the funnel.

3.Pour fresh coffee grounds into the filter and level the bed of grounds by gently shaking.

4.Slide the funnel into the funnel rails.

5.Place an empty decanter beneath the funnel.

6.Measure 64 ounces of cold water in a container and slowly pour the water into the pour-inopening.NOTE: When usingpour-overfeature to brew a 1 gal. batch, pour in 64 ounces of cold water and wait until drip out of funnel is complete then pour in 64 more ounces of cold water.

7.Press the ON/OFF button to activate the lower warmer (Indicator lamp on).

NOTE: Do not press theBrew Button. It is not necessary when using thepour-overfeature.

8.When brewing is completed, simply discard the grounds and filter.

CLEANING

1.The use of a damp cloth rinsed in any mild, non-abrasive,liquid detergent is recommended for cleaning all surfaces onBunn-O-Maticequipment.

2.Check and clean the sprayhead. The sprayhead holes must always remain open.

Page 7

35582 041503

 

CDBC, SINGLE CD ADJUSTMENTS & OPTIONAL SETTINGS

HIDDEN

SWITCH

P1866

Setting Brew Temperature

The brewer is factory set to brew at 200°F (93˚C). To change this setting, press and hold the "HIDDEN" switch beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature indicators shows the approximate desired temperature. When two indicators are glowing, the temperature is approximately the number between them.

Setting Brew Lockout

The brewer is factory set with the brew lockout disabled. Brew lockout prevents starting a brew cycle if the ready indicator is not glowing. When an attempt at brewing cannot be allowed, the word "NOT" and "LOCKOUT" flash for three seconds to indicate the reason the brew can't begin. To change the condition of the brew lockout, press and hold the "HIDDEN" switch beneath the "®" and momentarily press the "BREW" switch.

Adjusting Automatic Warmer Shut-Off

The brewer is factory set with this feature disabled. The automatic warmer shut-offdeenergizes all warmers after a predetermined time period after the most recent brew cycle. To change the setting, press and hold the "BREW" switch and the "HIDDEN" switch beneath the "®" for five seconds, the entire bank of temperature indicators will flashon-and-off.Release both switches. Pressing and releasing the "BREW" switch will select the number of temperature indicators from none to five. When no indicators are glowing, this feature is disabled and all warmers will be controlled only by their respective switches. When one of five indicators are glowing, it indicates the approximate number of hours of delay before all warmers will be automatically deenergized after the most recent brew cycle.

IMPORTANT: The tank must be full and fill solenoid shut off prior to making these adjustments.

Adjusting Brew Volumes

CDBC models are factory set to deliver 64 ounces ± 2 for each brew cycle.

SINGLE CD models are factory set to deliver 128 ounces ± 2 for each brew cycle when 1 gal. option is selected and 64 ounces± 2 for each brew cycle when 1/2 gal. option is selected.

Page 8

35582 041503

 

ADJUSTMENTS & OPTIONAL SETTINGS (cont.)

BREW VOLUME SET-UP: Use the following steps when the setting is unknown or a different circuit board is being installed.

1.Place an empty funnel in the funnel rails and an empty decanter/server or graduated vessel beneath the funnel.

2.Place the "ON/OFF" switch in the "ON", upper position.

3.Press and hold the brew start button until you hear the brew solenoid click on-and-offthree times (approximately 10 seconds). Release the button.

4.Allow the cycle to continue until the desired amount of water is dispensed and then turn "OFF" the brewer. The brewer is now set to dispense this amount of water for each subsequent brew cycle.

To increase the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty decanter/server or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Press and hold the "BREW" switch until you hear the solenoid clickon-and-offthree times (approximately 10 seconds), then release the "BREW" switch. Momentarily press and release the "BREW" switch once for each ounce (approximate) of water to be added to the prior setting and allow the brew cycle to finish.

To decrease the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty decanter/server or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Momentarily press and release the "BREW" switch once for each ounce (approximate) of water to be removed from the existing setting. Press and hold the "BREW" switch until you hear the solenoid clickon-and-offthree times (approximately 10 seconds), then release the "BREW" switch and allow the cycle to finish.

NOTE: For Model SINGLE CD, set 1/2 gallon and 1 gallon separately.

WATER SENSING THRESHOLD ADJUSTMENT PROCEDURE

1.Make sure the tank is full of water to be used for calibration. The water must be in contact with the refill probe.

2.Unplug the brewer from the power source, then press and hold the BREW button while power is reapplied.

3.Continue pressing the BREW button until the READY indicator begins to flash. Release the BREW button and then press it again momentarily.

4.The new calibration is automatically completed within a few seconds. If the water is too pure for use with the brewer, the READY indicator will flash very rapidly and the old calibration will be retained.

Page 9

35582 021604

 

PULSE BREW SETUP PROCEDURE (CDBC & SINGLE CD)

The pulse brew parameters (initial fill time, off times, and remaining on times) are entered using the following set- by-exampleprocess.

1.First set the brew volume using the standard procedure in Brew Volume Setup.

2.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.

3.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button. This begins the initial on-time setting. When the spray has continued for the desired time, momentarily press the OFF/ON button.

4.The spray is now stopped and the off time setting has begun. Press the OFF/ON button momentarily to end theoff time.

5.The spray is now on again and the remaining on time setting has begun. Press the OFF/ON button momentarily at the end of the desiredremaining on time.

6.The setup is now complete and the parameters are stored in memory. The spray will continue the off and on cycles until the brew volume of step 1 is complete. Pressing the OFF/ON button again will terminate the brewing cycle, with the parameters stored in memory.

7.If only a preinfusion is desired, i.e. an initial on time followed by one off period, use the same procedure, but stop after step 4 and allow the brew to finish the volume set in step 1. This will store the initial on time and off time in memory.

Procedure for Disabling Pulse Brew or Preinfusion:

1.Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY lamp is on, or that the BREW LOCKOUT function is turned off.

2.Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button.

3.Allow the spray to continue and press no buttons until spray stops. The pulse and preinfusion functions are

now disabled.

NOTE: When the brewer has been set up for pulse or preinfusion, the adjustment of brew volume is done the same as always and has no effect on the pulse brew parameters. The pulsing is temporarily disabled while adjusting the brew volume and automatically returns during normal brewing.

Page 10

35582 041503