SERVICE SUPPLEMENT

TO 39132.0000

BUNN-O-MATICCORPORATION

POST OFFICE BOX 3227

SPRINGFIELD, ILLINOIS 62708-3227

PHONE: (217) 529-6601FAX: (217)529-6644

39132.0003A 04/12 ©2010 Bunn-O-MaticCorporation

BUNN-O-MATICCOMMERCIAL PRODUCT WARRANTY

Bunn-O-MaticCorp. (“BUNN”) warrants equipment manufactured by it as follows:

1)Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor.

2)All other equipment - 2 years parts and 1 year labor plus added warranties as specified below:

a)Electronic circuit and/or control boards - parts and labor for 3 years.

b)Compressors on refrigeration equipment - 5 years parts and 1 year labor.

c)Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and labor for 4 years or 40,000 pounds of coffee, whichever comes first.

These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601or by writing to Post Office Box 3227, Springfield, Illinois62708-3227;2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon.

If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.

THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.

In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.

392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic,BUNN, BUNN with the stylized red line, BUNNlink,Bunn-OMatic,Bunn-O-Matic,BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design,Safety-Fresh,savemycoffee.com,Scale-Pro,Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, Velocity Brew, A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer Control, Nothing Brews Like a BUNN, Pouring Profits, Signature Series, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks ofBunn-O-MaticCorporation.

Page 2

39132.3 030912

 

INTRODUCTION

This equipment will brew a half-gallonbatch of coffee into an awaiting dispenser. It can be easily configured for 120V 15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf.

CONTENTS

Warranty...............................................................................................

2

Contents ..............................................................................................

3

Programming.......................................................................................

4

Schematic Wiring Diagram...............................................................

10

Page 3

39132.3 040312

 

PROGRAMMING

PROGRAMMING THE BREWER

The information in this manual covers only the differences between this model and the standard Axiom. Access to service level 4 is same as standard Axiom.

The following function screens are in order of appearance. Each screen will have instructions on how to access, and the procedures to program the various functions of the brewer.

IMPORTANT PROGRAMMING NOTES

- READ CAREFULLY -

To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch located on the front switch panel. The display will return to the MAIN SCREEN.

If none of the programming switches are pressed within one minute during the setup of the brewer, the programming of the function screen that is being set will be exited and the display will return to the MAIN SCREEN.

Always remember to place an empty server and funnel under the sprayhead when operating the brewer during the set-upof PULSE BREW, CALIBRATE FLOW and testing the brew valve in TEST OUTPUTS.

PROGRAMMING LOCKOUT SWITCH (Mounted on main control board)

This switch can be set to prevent access to the programming settings of the brewer. Once all the correct brew settings are programmed, the operator can set the switch to the "LOCK" position to prohibit anyone from changing the settings. With the switch in the "LOCK" position, the programming menus can still be accessed to view the current settings. However, no changes will be saved.

LOCK

SET

Disconnect brewer from power source before removing any panel!

REVERSE

FORWARD

READY TO BREW

WATER TEMP: 200°

Push and hold left "hidden" button to access service program modes.

Page 4

39132.3 040312

 

SERVICE PROGRAMMING

Freq&AdjustCaps?

 

DISPLAY BREW TIMES

 

TEST RFID BOARD

NO

YES

 

NO

YES

 

NO

YES

FRESHNESS TIMEOUT

 

GLASS FRESH HRS

 

ThermalFresh HRS

NO

YES

 

 

 

.5

(+)

 

 

 

 

 

(-)

(-)

2.0

(+)

 

 

 

 

 

 

 

 

 

 

 

WARMER MINs PAST

 

FRESHNESS SCAN

 

EXPIRATION ALARM

FRESHNESS:

5

 

NO

DONE YES

 

DISABLE ENABLE

 

 

EXPIRATION SECS

 

ADJUST ALARM

 

SET DATE/TIME ?

(-)

10

(+)

 

NO VOLUME ? YES

 

NO

YES

 

 

 

 

 

 

Return To Main Screen

PRE-EXPIREALARM

 

 

AXIOM

DISABLE ENABLE

 

VERSION xx.xx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displays Model &

 

 

 

 

Software Version

Page 5

39132.3 040312

 

SERVICE PROGRAMMING

Freq&AdjustCaps?

This allows you to monitor the frequency of the warmer(s) sensing

coils.

NO

YES

 

125.0

0000

* TOP F

125.0

0000

* TOP R

125.0 0000

* MAIN

Also allows you to monitor the adjustment capacitors, which are used to keep the coil frequency at it's nominal value (125.0 khz)

Use the "Brewer" button to toggle between screens.

Press right hidden button to advance to next function.

DISPLAY BREW TIMES

NO YES

MAY

10

2010

MAIN

10:00:00 AM

TEST RFID BOARD

NO YES

RFID CIRCUIT BOARD VERSION # xx.xx

This allows you to read the "age" of any brewed batch in a particular carafe (as long as it is equipped with an RFID chip). The sensor coil will read the chip and brewer will display time of day it was brewed.

This screen will automatically scroll through all warmers.

Press right hidden button to advance to next function.

This allows you to monitor individual sensing coils and RFID board.

CONTINUED

Page 6

39132.3 040312

 

SERVICE PROGRAMMING

PRESS ANY SWITCH

TO EXIT

 

10:00:00 AM

M

TF

 

TR

 

GLASS FRESH HRS

(-) .5(+)

ThermalFresh HRS (-)2.0 (+)

WARMER MINs PAST

FRESHNESS: 5

FRESHNESS SCAN NO DONE YES

EXPIRATION ALARM DISABLE ENABLE

If a carafe is placed on a particular warmer, a "box" will appear next to it's indicator. If the box is filled (solid) it's not expired yet. If the box is empty, the time is expired. See example: MAIN = expired; Top Front = not expired; Top Rear = expired.

Press right hidden button to advance to next function.

Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the glass decanter before an alert message is displayed. DEFAULT: .5

Range: OFF/0.5 - 4.0 hrs

Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the thermal server before an alert message is displayed. DEFAULT: 2.0

Range: OFF/0.5 - 4.0 hrs

Sets the amount of time the warmers will turn off after an alert message is displayed. DEFAULT: 5

Range: OFF/1 - 30 min

Allows brewer to continually scan the warmer sensor coils and display freshness times.

Enable/Disable beeper.

CONTINUED

Page 7

39132.3 040312

 

EXPIRATION SECS (-)10 (+)

ADJUST ALARM NO VOLUME ? YES

ADJUST ALARM

5

-

+

SET DATE/TIME ?

NO YES

SERVICE PROGRAMMING

Sets the amount of delay between alarm beeps.

Select "YES" to adjust beeper volume.

Press "+" to increase volume, or "-"to decrease.

Select "YES" to set date and/or time.

YEAR 2010

(-)DONE (+)

MONTH MAY

(-)DONE (+)

 

DAY

10

(-)

DONE

(+)

Press "+" to scroll year forward, or "-"to scroll year back.

Press "+" to scroll month forward, or "-"to scroll month back.

Press "+" to scroll day forward, or "-"to scroll day back.

CONTINUED

Page 8

39132.3 040312

 

SERVICE PROGRAMMING

Press "+" to scroll hour forward, or "-"to scroll hour back.

HOUR 10 AM

(-)DONE (+)

MINUTE 00

(-)DONE (+)

SECOND 00

(-)DONE (+)

Press "+" to scroll minute forward, or "-"to scroll minute back.

Press "+" to scroll seconds forward, or "-"to scroll seconds back.

PRE-EXPIREALARM

Enable/disable the 5 minute warning beep for a carafe about to expire.

DISABLE ENABLE

EXIT

Page 9

39132.3 040312

 

SCHEMATIC WIRING DIAGRAM

AXIOM BrewWISE-DV

 

Earth Ground

 

 

 

 

 

 

GRN

 

Chassis Ground

 

MAIN ON/OFF SWITCH

 

 

(Late Models only)

L1

L2

 

N

BLK

 

35

 

20

35

 

 

 

 

RED Model

 

WHI Model

Model 15 &

 

 

 

 

 

WHI

 

 

 

 

 

 

BLK-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT

 

 

SELECTOR

 

 

 

 

 

 

 

 

 

 

 

SWITCH

WHI-14

 

 

 

 

 

 

THERMOSTAT

BLU-14

TANK HEATER

 

 

 

 

 

 

BLK-14

 

BLK-14

BLU-14

 

TANK HEATER

 

 

 

 

 

 

 

 

1425W

 

RED-14

 

 

 

 

 

 

WHI/VIO-14

 

 

 

 

WHI

 

 

OPTIONAL FAUCET HEATER

 

2268W

 

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

BREW STATION WARMER

 

 

 

 

 

 

 

 

WHI/RED

(CONTROLLED BY ENABLE BREW SW)

 

WHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFILL

 

 

 

 

 

 

 

 

 

WHI/BLU

SOL

WHI

 

 

 

 

 

 

DISPENSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

RELAY

BLU-14

 

 

 

WHI/GRN

SOL

 

 

 

 

WHI

BLK-14

 

 

 

 

 

 

 

 

 

O

 

WHI

 

 

 

 

 

 

 

 

 

WHI

N

J1-1

 

 

 

 

 

(TOP WARMERS)

 

 

 

T

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

BRN/BLK P2

 

FRONT WARMER

 

P1

 

 

O

 

BRN/BLK

 

 

 

BRN/BLK

WHI

 

WHI

L

J1-5

WHI/BLU

 

 

 

 

 

 

 

 

 

 

P

WHI/RED

 

 

 

 

 

 

W

 

P1, P2, &

 

 

 

 

 

 

 

 

C

 

YEL

 

 

 

 

 

 

H

 

P3 ARE

B

 

WHI/VIO

 

 

 

P3

 

REAR WARMER

I

 

 

 

 

 

VIO

 

PINS OF A

O

 

VIO

 

 

 

 

 

 

 

 

 

 

 

 

POLARIZED

A

J1-10

WHI/GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE-PIN

R

 

 

 

 

 

 

(LEFT WARMER)

 

D

 

 

 

 

 

 

 

 

CONNECTOR.

 

 

 

 

 

 

 

 

 

 

 

BRN

 

J5-1

 

P2

YEL

FRONT WARMER

WHI

P1

 

WHI

 

J13-1

J1-1

 

 

 

 

 

 

TOP REAR WARMER SENSOR

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

ORN

 

J6-1

 

 

 

 

W

 

 

 

 

 

YEL

 

LOWER WARMER SENSOR

P3

 

REAR WARMER

H

 

 

 

 

J13-5

GRN

J1-5

 

WHI/VIO

I

 

 

 

 

 

BLU

 

J7-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RFID

TOP FRONT WARMER SENSOR

BOARD

 

 

J12-1

 

 

RED

 

BEEPER

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL SWITCH ASSY

J2-1

 

STATIC

 

(NOTE – ALL WARMERS ARE NOT

 

SHIELD

 

AVAILABLE ON ALL MODELS!)

 

 

 

 

 

J2-5

 

 

 

 

 

 

 

 

 

 

 

 

B1

A6

D1

A3

D2

A4

D3

A5

B2

A2

A1

J2-10

 

 

 

 

 

 

 

 

 

 

 

J3-1

BRN

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3-3

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J9-1

WHI

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

LEVEL PROBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SHORT)

 

 

 

 

 

 

 

 

t°

 

LEVEL PROBE

 

 

 

 

 

 

 

 

 

 

(LONG)

 

CONTROL SWITCH ASSY CODES

 

2 WARMERS

2 WARMERS

2 WARMERS

 

ON LEFT

ON TOP

ON RIGHT

BREW STATION

A3

A3

A3

LEFT FRONT

A2

 

 

LEFT REAR

A1

 

 

TOP FRONT

 

A5

 

TOP REAR

 

A6

 

RIGHT FRONT

 

 

A5

RIGHT REAR

 

 

A6

START BREW

A4

A4

A4

LEFT HIDDEN

B1

B1

B1

RIGHT HIDDEN

B2

B2

B2

“DIGITAL”

D1

D1

D1

“BREWER”

D2

D2

D2

“CONTROL”

D3

D3

D3

120V AC 2 WIRE

120/208V AC 3 WIRE

120/240V AC 3 WIRE

SINGLE PHASE

29077.0021A 06/10 ©2010 BUNN-O-MATICCORPORATION

Page 10