Broan 410, 418, EC62, 437, 441 User Manual

0 (0)
EC62 SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 12.
Broan-NuTone Canada Inc.; Mississauga, Ontario www.broan.ca 877-896-1119
www.broan.ca
REGISTER YOUR PRODUCT ON LINE AT: www.broan.ca
SV08970 rev. 05
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
WARNING WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off
at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. To reduce the risk of fire or electric shock, do not
use this unit with any additional solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10.
When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food (i.e. Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not
be allowed to accumulate
on fan, filters or in exhaust
ducts
.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may
be burned.
3. DO NOT USE WATER, including wet dishcloths or
towels – This could cause a violent steam explosion.
4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and
you know how to operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department has been called. D. You can fight the fire with your back to an exit.
*Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Your power pack motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the power pack serviced.
5. The minimum hood distance above cooktop must not be less than 24”. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. For a gas range, the bottom of the hood MUST NOT BE LESS than 30” above cooktop.
6. Two installers are recommended because of the large size and weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside – Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the Broan Elite EC62 Series models must be installed only with their own built-in blower(s). Other blowers cannot be substituted.
10. Please read specification label on product for further information and requirements.
!
!
- 3 -
- EC62 SERIES POWER PACK SYSTEM -
3¼” X 10” ADAPTER/DAMPER
(SUPPLIED WITH SINGLE BLOWER
POWER PACK
)
SINGLE BLOWER
(600 CFM, SUPPLIED
WITH POWER PACK
)
D
UAL BLOWER
(1000 CFM, SUPPLIED WITH
POWER PACK
)
L6230SS,
L6236SS
OR L6242SS
CUSTOM HOOD LINER
(OPTIONAL)
S
TANDARD
3¼” X 10” DUCT
(NOT INCLUDED)
EC622301SS
POWER PACK
EC621306SS
POWER PACK
STANDARD
3¼” X 10” ROOF CAP
(NOT INCLUDED)
STANDARD
3¼” X 10” WALL CAP
(NOT INCLUDED)
MODEL 437
HIGH CAPACITY ROOF CAP
(NOT INCLUDED)
MODEL 441
10” ROUND WALL CAP
(NOT INCLUDED)
MODEL 418 10” ROUND ADJUSTABLE ELBOW (NOT INCLUDED)
M
ODEL 410
10” ROUND DUCT — 2 FT. SECTIONS (NOT INCLUDED)
10” R
OUND VERTICAL
IN-LINE DAMPER (SUPPLIED WITH 1000 CFM
DUAL BLOWER POWER PACK
)
10” R
OUND ADAPTER
(SUPPLIED WITH 1000 CFM
DUAL BLOWER POWER PACK
)
L6230SS,
L6236SS
OR L6242SS
CUSTOM HOOD LINER
(OPTIONAL)
HL0126
- 4 -
1. PREPARE THE INSTALLATION
2. INSTALL DUCTWORK AND ELECTRICAL WIRING
Plan where and how the ductwork will be installed. Access to the top of the power pack is preferred for connection of ductwork. Install proper-sized ductwork, elbows and roof or wall cap for the type of power pack you are installing. If installing EC621306SS
single blower power pack, use 3¼” x 10” ductwork. If installing EC622301SS double blower power pack, use 10” round ductwork. Use 2” metal foil duct tape to seal duct joints.
We recommend to install the power pack at a minimum distance of 24” from an electric range and at 30” from a gas range.
Distances over 30” are at the installer and users discretion. Run 3-wire power supply cable to installation location. Its length should extend at least 4 feet below the bottom of the custom
hood.
Power pack
Roof cap
Wall cap
HH0116A
3¼ x 10 adapter & damper
24 minimum above cooking surface (30 for gas range)
3¼ x 10 duct
MODEL EC621306SS
(SINGLE BLOWER) TYPICAL DUCTWORK
Power pack
Roof cap
Wall cap
HH0117A
10 round duct
10 round adapter
10 round elbow
10 in-line vertical damper
24 minimum above cooking surface (30 for gas range)
MODEL EC622301SS
(DUAL BLOWER) TYPICAL DUCTWORK
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the
manufacturer.
Make sure that the following items are included
:
- Power Pack
- Accessories: • 2 Filters
• 2 Filter knobs with screws, taped inside the hood
• 2 Shielded halogen lamps (120 V, 50 W max., MR16 with GU10 base)
• 3¼” x 10” adapter and damper (supplied with 600 CFM single blower power pack)
• 10” round in-line vertical damper (supplied with 1000 CFM dual blower power pack)
• 10” round adapter (supplied with 1000 CFM dual blower power pack)
• Bag of parts including: 1 wire clamp, 2 wire connectors, 4 no. 8 x 3/8” screws, 9 no. 8 x 1/2” chrome plated screws, 10 no. 8-32 x 1/4” screws. If need be, discard extra screws.
Parts sold separately:
- Custom hood liner Model L6230SS, L6236SS or L6242SS (optional)
- Ducts, elbows, wall and roof caps. Refer to page 3 for a complete list of venting options and model numbers. NOTE: During installation, protect countertop and/or cooktop.
NOTE: Although the horizontal discharge installation is feasible with EC621306SS power pack model, this installation
type should be performed in specific situation only since it requires particular knowledge and technical skills from the installers.
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: The dual blower model has the same dimensions than the single blower model, but does not have a horizontal discharge.
Refer to single blower power pack illustration for back and side views, and discard horizontal discharge measurements.
3. PREPARE CUSTOM HOOD
The custom hood must be constructed to fit the shape and total weight of the EC62 power pack model. The recommended minimum thickness for the custom hood base is 5/8”. If an optional custom hood liner will be installed, we recommend the sides and front of the custom hood to be 3/4” thick. If the optional custom hood liner will not be installed, the custom hood sides and front thickness are at the installer’s discretion. See chart and illustration for details.
POWER PACK
TYPES
TOTAL
WEIGHT
SINGLE BLOWER 33 LB DUAL BLOWER 45 LB
- 5 -
SINGLE BLOWER POWER PACK
DUAL BLOWER POWER PACK
HK0114A
13 5/16
7/8”
ø10
TOP VIEW
WARNING
When building a custom hood, always follow all applicable construction codes and standards. The custom hood must be positively secured to wall studs or other wooden framework behind the drywall. Make sure it is capable of supporting its own weight and the weight of the power pack. Failure to do so may cause personal injury or damage to countertop or cooktop.
!
7/8”
15
2
/16
13 5/16
TOP VIEW
5/8”
16
3 ³/
10 1/8
10½
5/8”
3 ³/
16
10
15
/16
HK0104A
5
/8
26 28 1/8
BACK VIEW SIDE VIEW
11/16
13¼ 14¾
Loading...
+ 9 hidden pages