Briggs & Stratton 030235-01 User Manual

4.3 (3)
SAVE THESE INSTRUCTIONS
Model / Modelo
030235-01
5550 WATTS
8550 STARTING WATTS
Operator’s Manual
Manual del Operario
Manual No. 199408GS
Failure to read and follow the operator’s manual and all
operating instructions can result in death, bodily injury,
and/or property damage.
WARNING
Si no se leen y siguen las indicaciones del Manual del
Operario y todas las instrucciones de uso, se pueden
producir daños materiales, lesiones o incluso la muerte.
ADVERTENCIA
Briggs & Stratton Power Products Group, LLC
900 North Parkway
Jefferson, WI 53549
Copyright © 2006 Briggs & Stratton Power Products Group, LLC.
All rights reserved. No part of this material may be reproduced or
transmitted in any form by any means without the express written
permission of Briggs & Stratton Power Products Group, LLC.
Generator
Model Number 030235
Revision _______
Serial Number __________________
Engine
Model Number _______________________________
Serial Number _______________________________
Date Purchased
Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that you’ve placed your
confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual,
your Briggs & Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generator products
and how to avoid them. Because Briggs & Stratton does not necessarily know all the applications this generator could be
used for, it is important that you read and understand these instructions. Keep this manual near the generator for
convenient reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final
assembly procedures. Follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages.
There are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also
contact Briggs & Stratton Customer Service by phone at 1-800-743-4115 or on the Internet at
www.briggsandstratton.com.
1
Table of Contents
Safety Rules.................................................................2
Equipment Description..............................................................................4
Assembly .....................................................................4
Unpack Generator......................................................................................4
Shipment Contents.....................................................................................4
Install Wheel Kit .........................................................................................4
Verify Engine Oil Level ..............................................................................5
Add Fuel........................................................................................................5
System Ground............................................................................................6
Connecting to a Building’s Electrical System........................................6
Generator Location....................................................................................6
Features and Controls................................................7
Receptacles...................................................................................................8
Generator Adapter Cord Set ..................................................................8
Operation ....................................................................9
Starting the Engine......................................................................................9
Connecting Electrical Loads...................................................................10
Stopping the Engine..................................................................................10
Don’t Overload Generator....................................................................11
Maintenance..............................................................12
Oil ................................................................................................................13
Service Air Cleaner..................................................................................15
Service Spark Plug.....................................................................................15
Clean Spark Arrester Screen.................................................................15
Engine Air Cooling System.....................................................................16
Check Valve Clearance ...........................................................................16
Storage ........................................................................................................17
Troubleshooting........................................................18
Specifications ............................................................19
Warranties ................................................................20
2
www.briggsandstratton.com
SAVE THESE INSTRUCTIONS
Safety Rules
This is the safety alert symbol. It is used to
alert you to potential personal injury
hazards. Obey all safety messages that
follow this symbol to avoid possible injury or
death.
The safety alert symbol ( ) is used with a signal word
(DANGER, WARNING, CAUTION), a pictorial
and/or a safety message to alert you to hazards.
DANGER indicates a hazard which, if not avoided, will
result in death or serious injury. WARNING indicates a
hazard which, if not avoided, could result in death or
serious injury. CAUTION indicates a hazard which, if not
avoided, might result in minor or moderate injury.
CAUTION, when used without the alert symbol,
indicates a situation that could result in equipment
damage. Follow safety messages to avoid or reduce the
risk of injury or death.
The manufacturer cannot possibly anticipate every
possible circumstance that might involve a hazard. The
warnings in this manual, and the tags and decals affixed to
the unit are, therefore, not all-inclusive. If you use a
procedure, work method or operating technique that the
manufacturer does not specifically recommend, you must
satisfy yourself that it is safe for you and others. You must
also make sure that the procedure, work method or
operating technique that you choose does not render the
generator unsafe.
Hazard Symbols and Meanings
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through windows,
doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
When using generator for backup power, notify utility company.
Use approved transfer equipment to isolate generator from
electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces hazardous voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Fire
Explosion
Toxic Fumes
Hot Surface
Electrical Shock
Kickback
Operator’s Manual
Flying Objects
Using a generator indoors WILL KILL YOU
IN MINUTES.
Exhaust contains carbon monoxide, a
poison gas you cannot see or smell.
NEVER use in the home
or in partly enclosed
areas such as garages.
ONLY use outdoors and
far from open windows,
doors, and vents.
3
When adjusting or making repairs to your
generator:
Disconnect the spark plug wire from the spark plug and place the
wire where it cannot contact spark plug.
When testing for engine spark:
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat. Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
When adding or draining fuel:
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
When starting equipment:
Ensure spark plug, muffler, fuel cap and air cleaner are in place.
DO NOT crank engine with spark plug removed.
When operating equipment:
DO NOT tip engine or equipment at angle which causes fuel to
spill.
This generator is not for use in mobile equipment or marine
applications.
When transporting or repairing equipment:
Transport/repair with fuel tank EMPTY or with fuel shutoff valve
OFF.
Disconnect spark plug wire.
When storing fuel or equipment with fuel in tank:
Store away from furnaces, stoves, water heaters, clothes dryers or
other appliances that have pilot light or other ignition source
because they can ignite fuel vapors.
Fuel and its vapors are extremely flammable
and explosive.
Fire or explosion can cause severe burns or
death.
WARNING
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in death or serious injury and/or property
damage.
WARNING
When starting engine, pull cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and
turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains
could result.
WARNING
See Don’t Overload Generator.
Start generator and let engine stabilize before connecting electrical
loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
Use generator only for intended uses.
If you have questions about intended use, ask dealer or contact
Briggs and Stratton.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect them
from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
Assembly
Your generator requires some assembly and is ready for
use after it has been properly serviced with the
recommended fuel and oil level is verified.
If you have any problems with the assembly of your
generator, please call the generator helpline at
1-800-743-4115. If calling for assistance, please have the
model, revision, and serial number from the data tag
available. See Generator Controls and Features for data tag
location.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from
top to bottom.
4. Leave generator on carton to install wheel kit.
Shipment Contents
The generator is supplied with:
Operator’s manual
Adapter cord set
Wheel kit
Install Wheel Kit
NOTE: Wheel kit is not intended for over-the-road use.
You will need the following tools to install these
components:
13 mm wrench
Socket wrench with a 13 mm socket
Pliers
Safety glasses
Refer to Figure 1 and install the wheel kit as
follows:
1. Tip generator so that engine end is up.
2. Slide axle (A) through both mounting brackets.
3. Place a wheel (B) on each side as shown in Figure 1a.
4. Place a washer (C) on axle and then place an e-ring
(D) in axle groove.
1a
E
G
D
B
F
A
C
A
B
Figure 1 — Install Wheel Kit
A - Axle
B - Wheel
C - Flat Washer
D - E-Ring
E - Support Leg
F - M8 x 16 mm Capscrews
G - Hex Nuts
4
www.briggsandstratton.com

Equipment Description

Read this manual carefully and become
familiar with your generator. Know its
applications, its limitations and any hazards
involved.
The generator is an engine–driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads. The generator’s
revolving field is driven at about 3,600 rpm by a single-
cylinder engine.
Every effort has been made to ensure that the information
in this manual is both accurate and current. However, the
manufacturer reserves the right to change, alter or
otherwise improve the generator and this documentation
at any time without prior notice.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency and the California Air Resources Board.
DO NOT exceed the generator’s wattage/amperage capacity. See
Don’t Overload Generator in the Operation section.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
Always wear eye protection when installing/removing e-rings.
E-rings can cause eye injury.
E-rings can spring back and become airborne
when installing or removing.
CAUTION
5. Install e-ring with pliers, squeezing from top of e-ring
to bottom of axle.
6. Repeat steps 4 and 5 to secure second wheel.
7. Tip generator so that engine side is down.
8. Line up holes in support leg (E) with holes in
generator frame.
9. Attach support leg using 2 capscrews (M8 x 16 mm)
(F) and 2 hex nuts (G). Tighten with a 13 mm socket
wrench and 13 mm wrench.
10. Return generator to normal operating position
(resting on wheels and support leg).
Verify Engine Oil Level
The generator engine is shipped from the factory filled
with oil (API SJ or higher 10W-30). This allows for
generator operation in the widest range of temperature
and climate conditions. Before starting the engine, check
oil level and ensure that engine is serviced as described in
Maintenance.
NOTE: See Oil in the Maintenance section to review oil
recomendations. Verify provided oil in engine is the
correct viscosity for current ambient temperature.
Add Fuel
All fuel is not the same. If a starting or performance
problem is encountered immediately after new fuel has
been used, try another service station or change brands.
NOTE: This engine is certified to operate on gasoline.
Exhaust Emissions Control System: EM (Engine
Modifications).
Type of Fuel
1. Always use clean, fresh, unleaded gasoline with a
minimum of 87 octane/87 AKI (91 RON) with
equipment. DO NOT mix oil with fuel. DO NOT
modify the engine fuel system or carburetor to run on
alternative fuels.
NOTE: Fuel with up to 10% ethanol (gasohol) or up to
15% MTBE (methyl tertiary butyl ether) is acceptable.
IMPORTANT: Use of any fuel other than those
approved above will void warranty. Some areas require
that fuel pumps be marked if the fuel contains alcohols or
ethers. If you are not sure if your fuel contains alcohol or
ethers that are different than those approved above, then
check with the service station operator.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add unleaded gasoline (A) to fuel tank (B). Be
careful not to overfill. Allow at least 1.5" (38 mm) of
tank space (C) for fuel expansion, as shown in Figure 2.
4. Install fuel cap and let any spilled fuel evaporate before
starting engine.
To avoid engine problems, the fuel system should be
treated with a fuel preserver or emptied before storage of
30 days or longer. To protect the fuel system from gum
formation, use Briggs & Stratton FRESH START™ fuel
stabilizer plus. If fuel preserver is not used, drain the fuel
tank, start the engine and let it run until the fuel lines and
carburetor are empty. Use fresh fuel next season. See
Storage in the Maintenance section for additional
information.
NEVER use engine or carburetor cleaner products in the
fuel tank as permanent damage may occur.
High-altitude use
Operation at high altitudes (over 5,000 feet [1524 m]),
may require a high-altitude carburetor jet kit to improve
performance and decrease fuel consumption. See your
local authorized Briggs & Stratton dealer for more
information.
5
When adding fuel:
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
Fuel and its vapors are extremely flammable
and explosive.
Fire or explosion can cause severe burns or
death.
WARNING
Refer to Maintenance for oil fill information.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
Any attempt to crank or start the engine without
verifying it has been properly serviced with the
recommended oil will result in equipment failure.
CAUTION
Figure 2 — Fuel Expansion
A - Fuel
B - Fuel Tank
C - Tank Space
A
B
C
6
www.briggsandstratton.com
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles. The system ground is
connected to the AC neutral wire (the neutral is bonded
to the generator frame).
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the
generator. Please consult a qualified electrician, electrical
inspector, or the local agency having jurisdiction:
In some areas, generators are required to be
registered with local utility companies.
If the generator is used at a construction site, there
may be additional regulations which must be
observed.
Connecting to a Building’s Electrical
System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician. The
connection must isolate the generator power from utility
power and must comply with all applicable laws and
electrical codes.
Generator Location
Clearances and Air Movement
Place generator in a well ventilated area, which will allow
for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows, doors,
ventilation intakes, or other openings that can allow
exhaust gas to collect in a confined area (Figure 3).
Prevailing winds and air currents should be taken into
consideration when positioning generator.
When using generator for backup power, notify utility company.
Use approved transfer equipment to isolate generator from
electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces hazardous voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
A
Using a generator indoors WILL KILL YOU
IN MINUTES.
Exhaust contains carbon monoxide, a
poison gas you cannot see or smell.
NEVER use in the home
or in partly enclosed
areas such as garages.
ONLY use outdoors and
far from open windows,
doors, and vents.
Figure 3 — Generator Clearance for Typical Generator
A - Exhaust Port
7
A - 120 Volt AC, 20 Amp, Duplex Receptacles
May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical, lighting, appliance, tool, and motor
loads.
B - 120/240 Volt AC, 30 Amp Locking Receptacle
— May be used to supply electrical power for the
operation of 120 and/or 240 Volt AC, 30 Amp, single
phase, 60 Hz electrical, lighting, appliance, tool, and
motor loads.
C - Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
D - Choke Lever — Used when starting a cold engine.
E - Data Tag — Provides model, revision, and serial
number of generator. Please have these readily
available when calling for assistance.
F - Double Pole Circuit Breaker (AC) — A double
pole circuit breaker is provided to protect all the
receptacles and generator against electrical overload.
G - Fuel Tank — Capacity of five (5) U.S. gallons (18.9 l).
H - Fuel Valve — Used to turn fuel supply on and off to
engine.
I - Grounding Fastener — Consult your local agency
having jurisdiction for grounding requirements in your
area.
J - Oil Fill — Add engine oil here.
K - Recoil Starter — Used to start the engine.
L - Engine Rocker Switch — Set this switch to “On
before using recoil starter. Set switch to “Off” to stop
engine.
M - Spark Arrester Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrester
screen.
Features and Controls
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
C
B
I
F
J
E
D
K
L
A
G
M
H
www.briggsandstratton.com
8
Receptacles
120/240 Volt AC, 30 Amp, Locking Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set (A) rated for 250 Volt AC loads at
30 Amps (or greater) (Figure 4). You can use the same
4-wire cord if you plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 5,550 watts of power
(5.55 kW) at 23.1 Amps for 240 Volts or two independent
120 Volt loads at 23.1 Amps each. The outlet is protected
by a double pole rocker switch circuit breaker.
120 Volt AC, 20 Amp, Duplex Receptacles
Both duplex receptacles (Figure 5) are protected against
overload by a double pole rocker switch circuit breaker.
Use each receptacle to operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater). Inspect cord
sets before each use.
Generator Adapter Cord Set
The generator comes with a 25' generator adapter cord
set designed to provide two sets of 120 Volt, 20 Amp
outlets from one 120 Volt, 20 Amp duplex receptacle
(Figure 6).
The maximum load on each outlet is 20 Amps. The
maximum total load on both black wire outlets or white
stripe wire outlets is 20 Amps.
NOTE: Follow all safety precautions when connecting any
extension cord or device to the generator.
Figure 5 — 120 Volt, 20 Amp Duplex Receptacle
NEVER attempt to power a device requiring more amperage than
generator or receptacle can supply.
DO NOT overload the generator. See Don’t Overload Generator in
the Operation section.
Receptacles may be marked with rating value greater
than generator output capacity.
CAUTION
Figure 4 — 120/240 Volt AC, 30 Amp Receptacle
A - 4-Wire Cord Set
B - W (Neutral)
C - X (Hot)
D - Y (Hot)
E - Ground (Green)
A
240V
120V
120V
NEMA L14-30
Figure 6 — Generator Adapter Cord Set
B
C
D
E
9
Operation
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate the unit on a
level surface will cause the unit not to start or shut down
during operation.
2. Turn red fuel valve from “Off” position (A) to “On
position (B) (Figure 7).
3. Push choke lever to “Choke” position (Figure 8).
4. Push engine rocker switch to “On” (Figure 9).
5. Grasp recoil handle and pull slowly until slight
resistance is felt. Then pull handle rapidly to overcome
compression, prevent kickback, and start engine.
IMPORTANT: If excessive fuel is present in the air/fuel
mixture causing a “flooded” condition, move the choke
lever to “Run” ( ) position and pull the handle
repeatedly until the engine starts.
6. Move choke lever to “Run” ( ) position a short
distance at a time over several seconds in warm
weather or minutes in cold weather. Let engine run
smoothly before each change. Operate with choke in
Run” position.
NOTE: If the engine starts after 3 pulls but fails to run, or
if the unit shuts down during operation, make sure the unit
is on a level surface and check for the proper oil level in
the crankcase. This unit may be equipped with a low oil
protection device.
Figure 8 — Choke Lever
Figure 7 — Fuel Valve
A - “Off” Position
B - “On” Position
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat. Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
When starting engine, pull cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and
turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains
could result.
WARNING
Figure 9 — Engine Rocker Switch
B
A
10
www.briggsandstratton.com
Connecting Electrical Loads
1. Let engine stabilize and warm up for a few minutes
after starting.
2. Plug in and turn on the desired 120 and/or 240 Volt
AC, single phase, 60 Hz electrical loads.
NOTE:
DO NOT connect 240 Volt loads to the 120 Volt
duplex receptacles.
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See Don’t
Overload Generator.
Stopping the Engine
1. Turn OFF and unplug all electrical loads from
generator panel receptacles. NEVER start or stop
engine with electrical devices plugged in and turned
ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and
generator.
3. Push engine rocker switch to “Off” position (Figure 9).
4. Move fuel valve to “Off” position (A) (Figure 7).
See Don’t Overload Generator.
Start generator and let engine stabilize before connecting electrical
loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
DO NOT stop engine by moving choke lever to “Choke” position.
Backfire, fire or engine damage could occur.
WARNING
11
Don’t Overload Generator
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is
the amount of power your generator must produce to
keep your items running. See Figure 10.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator. There should be nothing connected to the
generator outlets before starting its engine. The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the
largest load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity,
as described above.
* Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance Watts (Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500
Light (75 Watts) 75
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge (Starting)
Watts
Essentials
Light Bulb - 75 watt 75 -
Deep Freezer 500 500
Sump Pump 800 1200
Refrigerator/Freezer - 18 Cu. Ft. 800 1600
Water Well Pump - 1/3 HP 1000 2000
Heating/Cooling
Window AC - 10,000 BTU 1200 1800
Window Fan 300 600
Furnace Fan Blower - 1/2 HP 800 1300
Kitchen
Microwave Oven - 1000 Watt 1000 -
Coffee Maker 1500 -
Electric Stove - Single Element 1500 -
Hot Plate 2500 -
Family Room
DVD/CD Player 100 -
VCR 100 -
Stereo Receiver 450 -
Color Television - 27” 500 -
Personal Computer w/17” monitor 800 -
Other
Security System 180 -
AM/FM Clock Radio 300 -
Garage Door Opener - 1/2 HP 480 520
Electric Water Heater - 40 Gallon 4000 -
DIY/Job Site
Quartz Halogen Work Light 1000 -
Airless Sprayer - 1/3 HP 600 1200
Reciprocating Saw 960 960
Electric Drill - 1/2 HP 1000 1000
Circular Saw - 7 1/4” 1500 1500
Miter Saw - 10” 1800 1800
Table Planer - 6” 1800 1800
Table Saw/Radial Arm Saw - 10” 2000 2000
Air Compressor - 1-1/2 HP 2500 2500
Figure 10 — Wattage Reference Guide
12
www.briggsandstratton.com
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized Briggs
& Stratton dealer for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To
receive full value from the warranty, the operator must
maintain the generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the Maintenance
Schedule chart above.
NOTE: Once a year you should clean or replace the
spark plug and replace the air filter. A new spark plug and
clean air filter assure proper fuel-air mixture and help your
engine run better and last longer.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual. See
Emissions Control System Warranty in the Warranties section.
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in
adverse conditions noted below.
¹ Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter.
Change oil sooner when operating under dirty or dusty conditions.
² Replace more often under dirty or dusty conditions.
Maintenance Schedule - Fill in Dates as You Complete Regular Service
Service Dates Service Dates
Maintenance Task
Before Each
Use
Every 25 Hours
or Yearly
Every 50 Hours
or Yearly
Every 100 Hours
or Yearly
Clean debris
X
Check oil level
X
Change engine oil
Service air cleaner
Service spark plug
X
Service spark arrester
X
Clean cooling system
Check valve clearance
X
Prepare for storage
If unit is to remain idle for longer than 30 days.
13
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture, or any corrosive vapors. Cooling air
slots in the generator must not become clogged with
snow, leaves, or any other foreign material.
NOTE: DO NOT use water or other liquids to clean
generator. Liquids can enter engine fuel system, causing
poor performance and/or failure to occur. In addition, if
liquid enters generator through cooling air slots, some of
the liquid will be retained in voids and cracks of the rotor
and stator winding insulation. Liquid and dirt buildup on
the generator internal windings will eventually decrease the
insulation resistance of these windings.
Cleaning
Daily or before use, look around and underneath the
generator for signs of oil or fuel leaks. Clean accumulated
debris from inside and outside the generator. Keep the
linkage, spring and other engine controls clean. Keep the
area around and behind the muffler free from any
combustible debris. Inspect cooling air slots and openings
on generator. These openings must be kept clean and
unobstructed.
Engine parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris:
Use a damp cloth to wipe exterior surfaces clean.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Oil
Oil Recommendations
NOTE: When adding oil to the engine crankcase, use only
high quality detergent oil classified “For Service SF, SG, SH,
SJ” or higher. DO NOT use special additives.
1. Choose a viscosity according to the following table:
* Check oil level frequently at higher temperatures.
NOTE: Synthetic oil meeting ILSAC GF-2, API
certification mark and API service symbol with “SJ/CF
ENERGY CONSERVING” or higher, is an acceptable oil at
all temperatures. Use of synthetic oil does not alter
required oil change intervals.
When adjusting or making repairs to your
generator:
Disconnect the spark plug wire from the spark plug and place the
wire where it cannot contact spark plug.
When testing for engine spark:
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
Improper treatment of generator can damage it and
shorten its life.
CAUTION