Bradford-White PDX-65S-65FB-3N User Manual

Size:
245.95 Kb
Download

"Highest in Subcontractor Satisfaction among Water Heater/Boiler Manufacturers"

Light Duty Commercial Power Direct Vent Energy Saver Gas Water Heater

Photo is of PDX-65S-65FB-3N

The LD Power Direct Vent FVIR Defender Safety System® Models Feature:

Closed Combustion Venting System—Power Direct Vent closed combustion system utilizes external air for combustion and exhausts directly to the outside through a separate two-pipe system. The air intake and exhaust vent are 3" connections. The equivalent feet of intake venting cannot be greater than the equivalent feet of exhaust venting.

Flammable Vapor Sensor—Electronicsensor prevents water heater operation if flammable vapors are detected.

Factory Installed Hydrojet® Total PerformanceSystem—Cold water inlet sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.

Vitraglas® Lining—BradfordWhite water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramicporcelain-likecoating.

Electronic Gas Control—Theintegrated, immersion gas control offers more precise temperature control for higher first hour delivery and also allows water temperature adjustment without removing the cover. The control is equipped with an LED display to aid instart-upand diagnostics.

More Precise Temperature Control—Withan adjustable temperature up to 180ºF. (Not recommended for 180ºF sanitization.)

Spark to Pilot Ignition System—Eliminatesthe constant burning pilot used on other water heaters.

Powerful Blower Motor—Ourdesign has higher torque for greater resistance to outside winds and the power to eliminate problems with difficult venting situations. This significantly quieter motor runs cooler for a considerably longer operational life.

Optional Concentric Vent Kit Termination—3" termination fitting provides for only one exit opening through a wall or roof. (Subtract 10ft. for intake pipe and 10ft. for exhaust pipe when calculating total vent length.)

Horizontal and Vertical Venting—With 3" or 4" PVC, ABS, or CPVC (Maximum equivalent vent length for each pipe on reverse side).

Side Connections—3/4"NPT tappings allow easy connections for space heating applications (Potable water only).

2" Non-CFC Foam Insulation—Surroundsthe tank surface, saving energy by retarding loss of heat(PDX-65Shas 1"Non-CFCInsulation).

Water Connections— 3⁄4" NPT factory installed true dielectric fittings extend water heater life and eases installation.

Factory Installed Heat Traps—Designincorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation.

Protective Magnesium Anode Rod—Provides added protection against corrosion for long trouble-free service.

Stainless Steel Flue Baffle—Maximizesthe amount of heat absorbed by the tank and reduces heat loss during standby periods.

Steel Tank—Heavygauge steel automatically formed, rolled and welded.

T&P Relief Valve—Included.

Brass Drain Valve.

Design Certified by CSA International (formerly AGA and CGA).

3 or 5-YearLimited Tank Warranties /1-YearLimited Warranty on Component Parts.

For more information on warranty, please visit www.bradfordwhite.com

For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.

Bradford White received the highest numerical score among water heater/boiler manufacturers in the proprietary J.D. Power and Associates/ McGraw-HillConstruction 2006 HVAC and Water Heater/Boiler Subcontractor Satisfaction StudySM. Study based on 882 responses measuring 3 water heater/boiler manufacturers and measures opinions of subcontractors. Proprietary study results are based on experiences and perceptions of subcontractors surveyed in May through July 2006. Your experiences may vary. Visit jdpower.com

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 B2; 5,954,492; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105.

Defender Safety System®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.

755-B-0807-A

Commercial Power Direct Vent Gas Water Heater

Light Duty Energy Saver Models

 

 

 

 

 

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS AND LIQUID PROPANE GAS

 

 

 

 

 

 

 

 

 

80% Recovery Efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery at

A

B

C

D

E

F

G

H

J

K

L

Approx.

 

 

 

 

100°F Rise*

Floor to

Jacket

Vent

Floor to

Floor

Floor to

Floor to

Floor to

Floor

Depth

Ct. Line

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

Exhaust

Dia.

Size

T&P

to

Space

Space

Air

to

 

Distance

Weight

 

 

Nat.

LP

Nat. Nat. LP

LP

 

 

U.S. Imp.

Outlet

 

 

Conn.

Gas

Heating

Heating

Intake

Water

 

From Intake

 

 

BTU/Hr. BTU/Hr.

U.S. Imp. U.S. Imp.

 

 

 

 

Conn.

Return

Supply

 

Conn.

 

to Exhaust

 

 

Gal. Gal.

Input

Input

GPH GPH GPH GPH

in.

in.

in.

in.

in.

in.

in.

in.

in.

in.

in.

lbs.

PDX-50S-60FB-3N

48 40

60,000

60,000

58

48

58

48

68

22

3

521/4

135/8

153/4

521/4

67

593/4

32

91/4

303

PDX-65S-65FB-3N

65 54

65,000

60,000

63

52

58

48

711/4

22

3

555/8

135/8

153/4

555/8

691/2

63

321/8

91/4

330

PDX-75S-70FB-3N

75 62

70,000

65,000

68

57

63

52

71

26

3

541/4

161/4

19

541/4

693/8

623/4

36

1111/16

375

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery at

A

B

C

D

E

F

G

H

J

K

L

Approx.

 

 

 

 

56°C Rise*

Floor to

Jacket

Vent

Floor to

Floor

Floor to

Floor to

Floor to

Floor

Depth

Ct. Line

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

Exhaust

Dia.

Size

T&P

to

Space

Space

Air

to

 

Distance

Weight

 

 

Nat.

LP

Nat.

 

LP

 

 

 

 

Outlet

 

 

Conn.

Gas

Heating

Heating

Intake

Water

 

From Intake

 

 

Liters

kW

kW

Liters/

Liters/

 

 

 

 

Conn.

Return

Supply

 

Conn.

 

to Exhaust

 

 

Input

Input

Hour

Hour

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

kg.

PDX-50S-60FB-3N

182

17.6

17.6

 

220

220

1727

559

76

1327

346

400

1327

1701

1517

812

235

137

PDX-65S-65FB-3N

246

19.0

17.6

 

238

220

1809

559

76

1489

346

400

1489

1765

1600

816

235

149

PDX-75S-70FB-3N

284

21.0

19.0

 

257

238

1803

660

76

1378

413

483

1378

1762

1594

914

297

170

All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix “B” to “C” and “N” to “X”.

For 5 year model, change suffix “3” to “5”.

*Based on manufacturers rated recovery efficiency.

110 V.A.C Required for Power Venting / 110 V.A.C., 60HZ, 3.1 Amperes.

C

 

 

 

3 3/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

K

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

B

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D & G

 

 

 

 

 

 

 

 

E

F

VENT

EXHAUST

3" Vent Pipe

 

PDX-50S

 

 

 

PDX-65S

PDX-75S

Max. Intake Length

 

60 ft.

50ft.

 

Max. Exhaust Length

 

60 ft.

50ft.

Min. Vent Length

 

7 ft.

7ft.

 

Number

1

55 ft.

45ft

 

of

2

50 ft.

40ft

 

90° Elbows†

3

45 ft.

35ft.

 

4" Vent Pipe

 

PDX-50S

 

 

 

PDX-65S

PDX-75S

Max. Intake Length

 

100 ft.

90ft.

 

Max. Exhaust Length

 

100 ft.

90ft.

Min. Vent Length

 

7 ft.

7ft.

 

Number

1

95 ft.

85ft.

 

of

2

90 ft.

80ft.

 

90° Elbows†

3

85 ft.

75ft.

 

Subtract 5ft. for each additional 90° elbow.

†Consult I&O Manual when using four or more elbows.

Concentric Vent Terminal Kit

INTAKE/

 

COMBUSTION

 

AIR

RAIN CAP

46 3/4"

P/N 239-44069-01

Meets NAECA Requirements

General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections are 1/2" (13mm).

All models design certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z-21.10.1and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potablewater heating appliance.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931Fax 215-641-1670 / Technical Support 800-334-3393Fax 269-795-1089Warranty 800-531-2111Fax 269-795-1089International:Telephone 215-641-9400Telefax 215-641-9750 /www.bradfordwhite.com

Sales / Technical Support 866-690-0961 / 905-238-0100Fax 905-238-0105 / www.bradfordwhite.com

©2007, Bradford White Corporation. All rights reserved.

 

 