Bradford-White 103-B User Manual

Size:
429.54 Kb
Download

Residential Direct Vent

Energy Saver Gas Water Heater

The Direct Vent FVIR Defender Safety System® Models Feature:

Closed Combustion—Allair for combustion is taken directly from the outside. Theco-axialvent pipe (pipe inside a pipe) draws combustion air in through the outer pipe (5"), and exhausts the products of combustion through the inner pipe (3"). Theco-axialvent pipe at the top of the unit can be rotated for venting flexibility.

Reinforced Seals—Sealssurround the closed combustion chamber and the FVIR inner door, preventing the ignition of flammable vapors outside of the water heater.

Piezo Igniter—Easyand quick lighting of the pilot burner by push button.

Pedestal Base—Ruggedand durable base allows easy transport and positioning, corrosion resistant contact with floor.

Maintenance Free—Theco-axialvent piping and the closed combustion chamber with reinforced seals do not require regular cleaning under normal operating conditions.

Sight Window—Offersa view into the combustion chamber to observe the operation of the pilot and burner.

No Electrical Power Necessary.

Factory installed Hydrojet® Total PerformanceSystem—Cold water inlet sediment reducing device. Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.

Vitraglas® Lining—BradfordWhite water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramicporcelain-likecoating. The Bradford White high silica Vitraglas® lining provides a tough interior surface for our water heater tanks.

Fully Automatic Controls—Built-ingas pressure regulation and energy cutoff switch.

Optional Vent Kits—Allowfor up to 8 foot max vertical and 8 foot max horizontal (2.4 meters). All DS models must be terminated horizontally.

1" Non-CFC Foam Insulation—Surroundsthe tank surface, saving energy by retarding loss of heat.

Water Connections—3/4"NPT factory installed true dielectric fittings extend water heater life and eases installation.

Factory Installed Heat Traps—Designincorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation.

Protective Magnesium Anode Rod—Provides added protection against corrosion for long trouble-free service.

Flue Baffle—Maximizesthe amount of heat absorbed by the tank and reduces heat loss during standby periods.

Steel Tank—Heavygauge steel automatically formed, rolled and welded.

T&P Relief Valve—Included.

Brass Drain Valve.

Design Certified by CSA International (formerly AGA and CGA).

Photo is of

DS1-50S6FBN

6 or 10-YearLimited Tank Warranties /6-YearLimited Warranty on Component Parts.

For more information on warranty, please visit www.bradfordwhite.com

For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534;

7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.

Defender Safety System®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.

103-B-0508-A

Residential Direct Vent Water Heater

Direct Vent Energy Saver Models

 

 

 

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

NATURAL GAS AND LIQUID PROPANE GAS

 

 

 

 

 

 

 

80% Recovery Efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery at

A

B

C

D

E

F

H

K

Approx.

 

 

 

 

 

90°F Rise*

Floor

Jacket

Vent

Floor

Floor

Floor

Floor

Depth

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

to Center

Dia.

Size

to T&P

to Gas

to Top

to Water

 

Weight

 

 

 

Nat.

LP

Nat. Nat. LP

LP

 

 

U.S. Imp.

Line of

 

 

Conn.

Conn.

of Heater

Conn.

 

 

 

BTU/Hr.

BTU/Hr.

U.S. Imp. U.S. Imp.

Vent

 

 

 

 

 

 

 

 

 

Gal. Gal.

Input

Input

GPH GPH GPH GPH

in.

in.

in.

in.

in.

in.

in.

in.

lbs.

DS1-40S6FBN

40

33

38,000

36,000

41

34

39

32

631/4 min.

20

3-5

431/2

147/8

493/4

503/4

299/16

162

DS1-50S6FBN

50

42

42,000

40,000

45

37

43

36

721/4 min.

20

3-5

521/4

147/8

583/4

593/4

299/16

181

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Capacity

 

 

 

Recovery at

A

B

C

D

E

F

H

K

Approx.

 

 

 

 

 

50°C Rise*

Floor

Jacket

Vent

Floor

Floor

Floor

Floor

Depth

Shipping

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

to Center

Dia.

Size

to T&P

to Gas

to Top

to Water

 

Weight

 

 

 

Nat.

LP

Nat.

 

LP

 

 

 

 

 

Line of

 

 

Conn.

Conn.

of Heater

Conn.

 

 

 

Liters

kW

kW

Liters/

Liters/

Vent

 

 

 

 

 

 

 

 

 

Input

Input

Hour

Hour

mm.

mm.

mm.

mm.

mm.

mm.

mm.

mm.

kg.

DS1-40S6FBN

151

11.1

10.5

 

155

148

1607

508

76-127

1105

378

1264

1289

737

73

DS1-50S6FBN

189

12.3

11.7

 

170

163

1835

508

76-127

1327

378

1492

1518

737

82

All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX". For 10 year models, change suffix from “6” to “10”.

*Based on manufacturers rated recovery efficiency.

The water heater is shipped with a standard vent kit. Vent Kit components are: 3" Vent tube and elbow, 5" Air Intake tube and elbow, Vent terminal and hardware, Inner and Outer wall terminal mounting flange, RTV silicone sealant.

 

 

 

 

 

 

Length “X”

 

 

 

 

 

 

 

 

133/4" to 143/16"

15" to 1711/16"

221/4" to 323/16"

36" to 557/8"

585/16" to 1045/16"

 

 

 

“Y”

 

10"

Order Kit A

Order Kit B

 

No Add’l. Kit Req’d.

Order Kit C

Order Kit D

 

 

 

143/4" to 1511/16"

Order (2) Kit A

Order Kit A & B

Order Kit A

Order Kit A & C

Order Kit A & D

 

 

 

 

 

 

 

Height

161/2" to 193/16"

Order Kit A

Order (2) Kit B

Order Kit B

Order Kit B & C

Order Kit B & D

 

 

 

233/4" to 3311/16"

Order Kit A

Order Kit B

 

Order Kit C

Order (2) Kit C

Order Kit D

 

 

 

 

 

 

 

 

 

371/2" to 573/8"

Order Kit C & A

Order Kit C & B

Order (2) Kit C

Order (3) Kit C

Order Kit C & D

 

 

 

 

5913/16" to 10513/16"

Order Kit D & A Order Kit D & B

Order Kit D

Order Kit D & C

Order (2) Kit D

 

 

 

The Vent tube and Air Intake tube provided with the heater telescopes from 1334" to 231116".

 

 

X

The kits found in the bold frame are needed in addition to the vent and air intake tube

 

 

 

provided with the water heater (utilizes the vent tube provided).

 

 

 

 

 

The kits found outside the bold frame do not utilize the vent tube provided with the

 

 

C

standard vent kit.

 

 

 

 

 

 

 

 

Y

For vent distances not found in the selection chart above, please contact the

 

 

 

 

 

 

 

Product Department for sizing recommendations.

 

 

 

 

 

73/4"

Optional vent kit :

 

 

 

 

 

 

 

 

 

Kit “A”

Telescopes from 434" to 51116"

Part No. 243-41260-00

 

 

 

 

Kit “B”

Telescopes from 612" to 9316"

Part No. 243-41331-00

 

 

 

 

Kit “C”

Telescopes from 1334" to 231116"

Part No. 243-41029-00

 

 

 

A

Kit “D”

Telescopes from 491316" to 951316"

Part No. 243-41424-00

F

B

H

K

Horizontal Vent Termination Only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

Please specify part number when ordering optional vent kit.

 

 

 

 

 

For additional information, please reference the installation instructions.

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

Meets NAECA Requirements

General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All gas connections 1⁄2" (13mm).

All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potablewater heating appliance.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales 800-523-2931Fax 215-641-1670 / Technical Support 800-334-3393Fax 269-795-1089Warranty 800-531-2111Fax 269-795-1089International:Telephone 215-641-9400Telefax 215-641-9750 /www.bradfordwhite.com

Sales / Technical Support 866-690-0961 / 905-238-0100Fax 905-238-0105 / www.bradfordwhite.com

©2008, Bradford White Corporation. All rights reserved.

 

 

103-B-0508-A

Printed in U.S.A.