INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS

MODEL 125FX LP and 125FX NG

(Flow Modulated with Electronic Ignition and Power Venting – a Type III Category Appliance) Suitable for heating potable water only

Not approved for space heating purposes

Intended for variable flow applications with steady cold water inlet temperatures

WARNING

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Upon completion of the installation, these instructions should be handed to the user of the appliance for future reference.

In the Commonwealth of Massachusetts this product must be installed by a licensed plumber.

FEATURING: Automatic Variable Power Modulating Gas Valve, Electronic Ignition and Power Venting

If the information in this manual is not followed exactly. A fire or explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable, combustible or corrosive vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

-Close gas valve. Open windows.

-Do not try to light any appliance.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency or the gas supplier.

TABLE OF CONTENTS

Specifications ....................................................

Page 2

Rules for safe operation ....................................

Page 4

Locating the Heater ............................................

Page 4

Combustion Air Requirements ............................

Page 5

Mounting the Heater ...........................................

Page 5

Venting the Heater .............................................

Page 6

Gas Connections ...............................................

Page 9

Water Connections ..........................................

Page 10

Electrical Connections ......................................

Page 11

Safety before turning on the heater ...................

Page 12

Lighting and Operating instructions ..................

Page 12

Setting water temperature ................................

Page 12

Maintenance & Service.....................................

Page 13

Trouble Shooting ..............................................

Page 14

Diagram of AquaStar.........................................

Page 17

Components and Parts List ..............................

Page 18

Principle of Operation:

When a hot water faucet is opened, the flow of water through the heater causes the gas valve to open. At the same time a microswitch is activated which sends a spark to the pilot. The flame sensor confirms that the pilot has been lighted and allows the first two burners to ignite. The flame sensor confirms correct activation and all burners ignite. The pilot goes out. The power exhaust system runs as long as the burners are on. The heat exchanger coils absorb the heat generated by the burners and transfer heat to the water. When the hot water faucet is shut off, the gas valve automatically closes and the burners turn off, followed immediately by the exhaust system. Your hot water faucet is an ignition key to turn on the water heater, giving you control over your hot water energy use. Every time you turn off your hot water faucet, the energy consumption for hot water returns to zero.

FEATURES

-Electronic Pilot Ignition

-On/Off switch to activate system

-Power Venting with safety shutoff

-High Quality Materials for Long Working Life.

-Copper heating coils for endless supply of hot water.

-Burner output proportional to hot water flow demand for maximum energy efficiency.

-Safety flame sensor at pilot burner.

-Automatic overheating protection shut-off sensor.

-Stainless steel burners with stabilized blue flame.

-Built-in corrosion resistant power venter.

-Compact space saver: mounts on a wall with two hooks.

-Easily removable one-piece cover.

-Easy one person installation.

-Adjustable water flow restrictor to ensure that water flow demand will not exceed the heating capacity of the heater.

BOSCH is constantly improving our products, therefore specifications are subject to change without prior notice.

AquaStar 125FX LP and 125FX NG Specifications

 

AQ125FXNG

AQ125FXLPG

 

 

 

max.

130 000 Btu/hr

125 000 Btu/hr

Gas input

 

 

 

 

min.

28 000 Btu/hr

28 000 Btu/hr

 

 

 

Water Connection 1/2” Thread fitting NPT

H x W x D 29 3/4” x 18 1/4” x 8 3/4"

 

Vent 4” (Category III Gas Appliance)

 

Gas Connection 1/2” NPT thread

 

Min. Water Pressure 18 Psi

 

Max. Water Pressure 150 Psi

 

Shipping Weight 50.6 LB

 

Net Weight 44 LB

 

2.0 GPM at 90° rise

 

4.0 GPM at 45° rise

 

Min. Water Flow 1/2 gal/min

 

120V/60Hz 1.2 Amps

 

LP GAS Supply Pressure

min. 11” W.C.

(before Aquastar regulator)

max.14” W.C.*

Required LP GAS pressure at inlet

 

tap while Aquastar is operating:

10.5” W.C.

LP GAS Burner Manifold pressure while

Aquastar is operating at maximum input: 9.9” W.C.

Natural Gas Supply Pressure

 

(before Aquastar regulator)

min.: 7” W.C.

 

max.: 14”W.C.*

Required Natural Gas Pressure at

 

inlet tap while Aquastar is operating:

5.7”W.C.

Natural Gas Burner Manifold pressure while Aquastar is operating at maximum input: 5.38” W.C.

* Inlet gas pressure before Aquastar regulator must not exceed this value. Pressure may need to be adjusted for high altitudes, see page 10.

UNPACKING THE AQUASTAR HEATER

This heater is packed securely. The box includes two water connection fittings, a control knob, a gas pressure regulator, a pressure relief valve, an incandescent particle tray, two hooks for hanging the heater, this manual, a warranty statement and a warranty registration card. Do not lose this manual as there is a charge for replacement. Please complete and return the enclosed warranty registration card. The FXHOOD horizontal vent terminator is supplied separately from the 125FX water heaters. There is a set of installation instructions in the FXHOOD box.

2

Bosch 125FX LP, 125FX NG User Manual

D084_089

FRONT VIEW

SIDE VIEW

MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS

 

MODEL 125FX

 

 

 

TOP (A)

12

"

FRONT (B)

4

"

BACK

0

" *

SIDES

4

"

FLOOR (C)

12

" **

VENT DIAMETER

4

"

*On a combustible wall surface the unit should be mounted away from the wall to provide adequate clearance of the vent pipe.

See page 5 for instructions.

**Some local codes require 18” in garage installations

AQUASTAR MODEL 125FX

3

GENERAL RULES TO FOLLOW

FOR SAFE OPERATION

1.You should follow these instructions when you install your heater. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54.

In Canada: The Installation should conform with CGA B149.(1,2) INSTALLATION CODES and /or local installation codes.

2.Carefully plan where you install the heater. Correct combustion air supply and flue pipe installation are very important. If not installed correctly, fatal accidents can be caused by lack of air, carbon monoxide poisoning or fire.

3.The place where you install the heater must have enough ventilation. The National Fire Codes do not allow gas fired water heater installation in bathrooms, bedrooms or any occupied rooms normally kept closed. See the section below on locating the heater.

4.You must install your heater so that the venting complies with all requirements. Venting must comply with all requirements for Category III gas appliances. See section on Venting the Heater, pages 6 and 7.

5.The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa).

The appliance must be isolated from the gas supply piping during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 Psig (3.5Kpa). The appliance and its gas connection must be leak tested before placing the appliance in operation.

6.Keep water heater area clear and free from combustibles and flammable liquids. Do not locate the heater over any material that might burn. Do not install heater over carpeting.

7.Correct gas pressure is critical for the optimum operation of this heater (see specifications on page 2 and chart on page 9). Gas piping must be sized to provide the required pressure at the maximum output of the heater. Check with your local gas supplier, and see the section on connecting the gas supply.

8.Should overheating occur or the gas supply fail to shut off, turn off the gas supply at the manual gas shut off valve on the gas line.

9.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

10.When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code ANSINFPA 70 and/or the CSA 22.1 Electrical Code.

PROPER LOCATION FOR INSTALLING YOUR HEATER

Carefully select the location of your new heater. For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation.

The heater may still operate even when improperly vented. It will, however, be less efficient and could eventually damage the heater. It could even result in human sickness or death due to oxygen deprivation and carbon monoxide poisoning. Before installing the unit, be certain you have the correct heater for your type of Gas – Propane or Natural Gas. Identification labels are found on the shipping box, and on the rating plate which is located on the right side panel of the cover.Also, each burner orifice is stamped with a number (79 for LPG and 120 for Natural Gas).

Follow the guidelines below:

1.National building codes require that you do not install this appliance in bathrooms, bedrooms, unvented closet or any occupied rooms normally kept closed.

2.Simultaneous operation of other appliances such as exhaust fans, ventilation systems, clothes dryers, fireplaces or wood stoves could create a vacuum effect in your home which could cause dangerous combustion by-products to spill back into your home rather than venting to the outside through the flue. Confirm that your Aquastar is venting properly when all these other appliances are running. See page 6 to test venting performance.

Do not obstruct the flow of combustion air to the appliance. This appliance is power vented and uses room air. Note: Electrical power is required to operate the power exhaust. Proper air supply to the appliance is essential.

If installed near a clothes dryer it is very important that the dryer be properly vented. Failure to properly vent a dryer could result in a gradual accumulation of lint on the water heater fin coils and burners, leading to a dangerous condition of vent blockage and poor, unsafe combustion.

3. Your hot water lines should be kept short to save energy. It is always best to have hot water lines insulated.

WARNING: DO NOT INSTALL IN AN AREA WHERE IT COULD FREEZE. This heater is neither designed for nor approved for outside installation. Drain the heater entirely if freezing temperatures are anticipated in area where heater is installed by disconnecting both the inlet and outlet elbow connections at the rear of heater. Additionally, remove the drain plug under the water valve. See Fig 0.”

Fig. 0 - Water heater drain plug

WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are potentially fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids.

4

COMBUSTION AIR REQUIREMENTS

CLEARANCES

The AquaStar water heater holds cold water in its copper heat exchanger and brass water valve when not in use. Because of this, any cold air that comes in through the unit’s vent pipe is capable of freezing these components. This Installation Manual specifies the vent length requirements and the amount of combustion air required for this unit. When all requirements are followed, the unit will operate properly and safely. However, there may still be a risk of freezing due to negative draft if all the combustion appliances in the area are not being supplied with a sufficient amount of make-up air. A wood stove or furnace can rob the make-up air in the AquaStar’s vent pipe, leaving the cold infiltrating air capable of freezing the cold water in the AquaStar heat exchanger. To prevent this the FXHOOD horizontal vent terminator, which is supplied separately with the water heater, needs to be installed on the end of the horizontal vent run (see page 7). The FXHOOD is a CSA approved vent terminator for the Aquastar 125FX and has a built in back draft flapper.

Observe the following instructions concerning combustion air.

Appliances located in unconfined spaces:

a)An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 6500 cubic feet for the AquaStar 125FX alone.

b)In unconfined spaces in buildings of conventional frame, masonry, or metal construction, infiltration is normally adequate to provide air for combustion, ventilation, and dilution of flue gasses.

Appliances located in confined spaces: The confined space must be provided with two permanent openings, one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure. Each opening must have a minimum free area of one square inch per:

1000 Btu/hr if all air is taken from inside the building.

2000 Btu/hr if all air is taken from the outside by horizontal ducts.

4000 Btu/hr if all air is taken from the outside by direct openings or vertical ducts.

Or the confined space must be provided with one permanent opening or duct that is within 12 inches of the ceiling of the enclosure. This opening must have a minimum free area of one square inch per:

3000 Btu/hr if all air is taken from the outside by a direct opening or vertical duct.

Louvers, grills and screens have a blocking effect. If the effective free area is not known, assume it is 20 % to 25% of the total opening for wood louvers and 60 % to 75% for metal louvers. Refer to the National Fuel Gas Code for complete information. In buildings of tight construction all air should be taken from outside.

This product is not approved for manufactured homes (mobile home), recreational vehicles (RV) or boats. Reference ANSI Z21.10.3.

This product is neither designed or approved for outside installations.

The Aquastar 125FX is design certified for installation on a combustible wall and for installation in an alcove or closet with the minimum clearances to combustible and non - combustible construction listed below

A.Top 12 inches (305 mm)

B.Front 4 inches (102 mm)

C.Back 0 inches*

D.Sides 4 inch (102mm)

E.Bottom 12 inches (305 mm)**

*On a combustible wall surface the unit should be mounted away from the wall to provide adequate clearance of the vent pipe. See mounting instructions below.

**Some local codes require 18” in garage installations.

Clearance from vent pipe is dependent upon the clearance rating of the venting material used. Single wall flue pipe should be used and it is approved for 3” clearance for this appliance. NOTE: See mounting instructions below to properly maintain a 3” clearance from the vent pipe to a combustible surface.

Note: this clearance can be reduced if combustible material are protected as per table VI of the National Fuel Gas Code.

MOUNTING INSTALLATION

The Aquastar 125FX is design certified for mounting on a wall.

Secure the two L shaped hooks, which are provided with heater, to a wall surface. Place them 13 ¼” apart as shown in Fig 2.

Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet. The heater must be mounted on a wall using appropriate anchoring materials. If wall is a stud wall sheathed with plasterboard, it is recommended that support board(s) either 1x4’s or 1/ 2" (minimum) plywood first be attached across a pair of studs and then the heater should be attached to the support boards. See Fig 2.

NOTE: Additionally the 125FX should be spaced away from any combustible wall surface by a minimum of 1 ½” to provide the needed 3” clearance between the vent pipe and the wall surface. Review the FXHOOD horizontal vent terminator instruction sheet (provided with the FXHOOD) prior to heater installation.

In earthquake-prone zones, CEC recommends that installers use a large washer and lag screw through the existing holes used to hang the heater to affix the upper third of the heater to the mounting board. To affix the lower third of the heater, CEC recommends that two new holes be drilled in the heater’s frame, each one 16 inches below the top two holes, and that washers and lag screws be used to secure the lower portion of the heater to a spacing board.

Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which, if mounted directly to a brittle, friable board, such as plasterboard, can cause failure of mounting.

5

WALL STUDS

13 ¼”

SUPPORT BOARD

1” X 4”

SPACE BOARD

Fig. 2 - Mounting the Heater

The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided. See figure 3.

SCREWS

INCANDESCENT PARTICLE TRAY

Fig. 3 - Incandescent Particle Tray Illustration

VENTING

WARNING: Do not reduce the vent pipe size.

This appliance must be vented horizontally to the outside with sealed 4” single wall vent pipe following all local ordinances and specifications for installing a power vented Category III appliance. The 4” single wall vent pipe can be either stainless steel (AL29-4C) or galvanized vent of at least 26 gauge. Stainless steel is preferred. All connections must be properly sealed. The vent system must be installed by a qualified installer in accordance with all applicable local gas codes. The venting system must be designed and constructed so as to develop a positive flow adequate to remove flue gases to the outdoors.

CAUTION: Aquastar power vent system must be installed by a qualified agency in accordance with these instructions. If improperly installed a hazardous condition such as an explosion or Carbon Monoxide poisoning could result. Controlled Energy Corporation will not be responsible for improperly installed appliances.

Plan the vent system so that code and manufacturer’s clearances are maintained.

The minimum clearance from the top of the heater is 12 inches. Single wall vent pipe when mounted to the 125FX requires a 3-inch clearance from combustibles. In all cases, follow local codes:

-In Canada, CAN/CGA-B149 Installation Code for detailed requirements.

-In USA, ANSI Z223.1 – latest edition, National Fuel Gas Code for detailed.

Minimum vent size diameter must be 4”. The appliance must be located as close as practicable to a vent terminal.

Maximum vent length is 15 feet (4.6m) with two 90degree elbows. This unit may be directly connected to an approved vent termination with a 90-degree elbow. The vent pipe connections must be secured to each other with a minimum of 4 sheet metal screws per connection, and all seams must be sealed with an approved high temperature silicone sealant and aluminum duct tape. The vent system must be gas tight. See Fig 4 for suggested venting installation diagrams.

For best results, the horizontal vent system should be as short and straight as possible. Vent pipe must be single wall stainless steel (AL29-4C) or galvanized vent pipe of 26 minimum gauge. The maximum allowable horizontal length of vent pipe is 15 feet. 2 elbows are allowable within this maximum vent length. For each additional elbow deduct 5 feet from maximum vent length. Any vertical portion of the vent pipe that is part of the horizontal vent system must be considered part of the allowable 15 foot maximum. When the horizontal vent run exceeds 5 feet the following criteria must be observed:

-Support the vent run at 4-foot intervals with overhead hangers.

-Horizontal sections of vent connectors must rise ¼” for every foot of horizontal length. Any vent section greater than 45 degrees from vertical is considered horizontal.

Note: Single wall vent pipe cannot be used in any concealed locations and should not be used in any unheated space without an insulated chase. Unsealed 5” or 6” size double wall B-Vent may be used as a chase for straight lengths (no elbows) of the 4” single wall vent pipe. All connections of the 4” single wall vent inside the 5” or 6” B-Vent must be properly sealed. A 1” clearance is required from the B-Vent pipe to combustibles.

Freeze Warning:

As mentioned on Page 5, negative air pressure in cold climates will cause a reverse airflow in the vent system that can freeze and damage the Aquastar heat exchanger when not in use. To prevent this the FXHOOD horizontal vent terminator, which was supplied separately with the water heater, needs to be installed on the end of the horizontal vent run (see page 7). The FXHOOD is a CSA approved vent terminator for the Aquastar 125FX and has a built in back draft flapper.

Spill Switch Safety:

The 125FX is equipped with a Spill Switch; it’s mounted on the left side of the draft diverter (Flue gas safety device - #9 on page 19). Before leaving the installation site verify proper Spill Switch operation by temporarily blocking termination outlet. Once blocked then operate the heater, the unit should shut down within 1-3 minutes when the flue gases are blocked. You must reset the electrical power to the heater after this safety test has been conducted, otherwise the unit will not operate.

6