Black Box 39005 User Manual

Size:
184.28 Kb
Download

MARCH 2000 39004 39005

T1 Fiber Optic Line Extender/Simulator

TX

RX

FO

TX

 

RX

 

FO/S

 

 

 

 

 

C

 

 

I/F

 

 

 

LL

DL

 

 

LOOP

 

 

 

 

 

CUSTOMER

Order toll-free in the U.S. 24 hours, 7

A.M. Monday to midnight Friday: 877-877-BBOX

SUPPORT

FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax724-746-0746

INFORMATION

Mail order: Black Box Corporation,

1000 Park Drive, Lawrence, PA 15055-1018

 

Web site: www.blackbox.comE-mail: info@blackbox.com

FCC INFORMATION

FEDERAL COMMUNICATIONS COMMISSION

AND

INDUSTRY CANADA

RADIO FREQUENCY INTERFERENCE STATEMENTS

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.

1

T1 FIBER OPTIC LINE EXTENDER/SIMULATOR

NORMAS OFICIALES MEXICANAS (NOM)

ELECTRICAL SAFETY STATEMENT

INSTRUCCIONES DE SEGURIDAD

1.Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.

2.Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3.Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4.Todas las instrucciones de operación y uso deben ser seguidas.

5.El aparato eléctrico no deberá ser usado cerca del agua—porejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc..

6.El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.

7.El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.

8.Servicio—Elusuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.

9.El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.

10.El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.

11.El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.

2

NOM STATEMENT

12.Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.

13.Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.

14.El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.

15.En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.

16.El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.

17.Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.

18.Servicio por personal calificado deberá ser provisto cuando:

A:El cable de poder o el contacto ha sido dañado; u

B:Objectos han caído o líquido ha sido derramado dentro del aparato; o

C:El aparato ha sido expuesto a la lluvia; o

D:El aparato parece no operar normalmente o muestra un cambio en su desempeño; o

E:El aparato ha sido tirado o su cubierta ha sido dañada.

3

T1 FIBER OPTIC LINE EXTENDER/SIMULATOR

General Safety Precautions

Transport, Installation, and Operation

Avoid excessive vibration and shocks.

Avoid contact with water and dust.

Avoid excessive direct sunlight.

Ensure sufficient cooling.

Prevent loose items from falling into the device.

Fiber Optics

Looking into the fiber optic output can cause injury to the eyes. When observation is necessary, avoid exceeding the limits recommended in ANSI Z136.1-1981.

Mains Power

Disconnect the power cord before opening the device.

Use exclusively the included power supply with an approved power cord.

The power plug must be plugged into a properly grounded receptacle. An improperly wired receptacle could place hazardous voltage on accessible metal parts of the device.

The mains supply must match the Simulator’s power specification.

Replace blown fuses with fuses of the exact type and rating.

Do not work on the equipment during periods of lightning activity.

4

TRADEMARKS

TRADEMARKS USED IN THIS MANUAL

ST® is a registered trademark of American Telephone and Telegraph Company.

Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.

5

T1 FIBER OPTIC LINE EXTENDER/SIMULATOR

Contents

1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.2 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.3 Typical Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3. Connectors, Indicators, and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4. Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

5. Data Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Appendix: Fiber Optic Planning Guidelines . . . . . . . . . . . . . . . . . . . . . . . . 16

A.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

A.2 Fiber Optic Calculation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

A.3 Operation Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

6

CHAPTER 1: Specifications

1. Specifications

Maximum Distance—39004:3 mi. (4.8 km) @ 16 dB; 39005: 24 mi. (38.6 km) @ 16 dB

Speed—1.544Mbps

Interface—DTE:T1, G.703/DS1; Fiber: Dual ST® multimode orsingle-mode

Connectors—DB15for DTE, dual ST for fiber

Indicators and Buttons—(6)LEDs: TX, RX, FO/S, C, LL, DL; (1) Loop mode button

Optical*—Standard:1300-nmSM LED; Pulse width: 648 ns; Transmitter output power:-13or-18dBm**; Pairs optical power budget: 9/125 µm, 18 dB; Receiver operation range:-15through-31dBm

G.703—Transmitlevel: 15.7 dBm; Maximum attenuation: 6 dB; Line impedance: 100 or 120**

Temperature Tolerance—Operating:41 to 104°F (5 to 40°C); Storage:-22to +176°F(-30to +80°C)

Humidity—10to 90% noncondensing

Power—115-VACexternal power supply, 60 Hz, 12 W

Size—1.5"Hx 5.8"W x 8.8"D (3.8 x 14.7 x 22.4 cm)

Weight—3.3lb. (1.5 kg)

*Optical specifications are valid at 77°F (25°C).

**Depends on setup.

7

T1 FIBER OPTIC LINE EXTENDER/SIMULATOR

2. Introduction

2.1 Description

The T1 Fiber Optic Line Extender/Simulator lets you combine fiber optic technology with standard interfaces at 1.544 Mbps. The advantages are increased transmission distances and immunity to electrical interference. Connections between buildings become possible since no lightning currents can arise.

2.2 Features

Extend or interconnect T1 lines, PBXs, or T1 muxes across distances up to 3 miles (4.8 km) via a pair of these devices.

For line simulation, the device is transparent to equipment, framing, and encoding—PBXsand multiplexors act like they’re directly connected to a T1 circuit.

EMI/RFI and lightning-hazardimmunity is provided by the fiber link.

2.3 Typical Application

T1 Fiber Optic Line

Extender/Simulator

T1 Fiber Optic Line

Extender/Simulator

8

CHAPTER 3: Connectors, Indicators, and Controls

3. Connectors, Indicators, and

Controls

 

 

 

10

 

9

 

 

1

 

 

 

 

 

 

TX RX

 

 

 

I/F

 

 

FO/S

RX

FO

TX

 

 

 

 

 

 

C

 

 

 

 

 

LL DL

 

 

 

 

 

 

LOOP

 

 

 

2

3

4

5

6

7

8

 

A

 

Figure 3-1.Front and Rear Panels.

 

Table 3-1.Connectors, Indicators, and Controls

 

 

No.

Connector, Indicator, or Control

 

 

1

TX LED: Transmitting binary 0 via fiber optic

2

G.703 connector

3

FO/S LED: Power/FO Link/sync

4

LL LED: Unit in line loop mode*

5

DL LED: Unit in digital loop mode*

6

Loop mode button

7

ST connector for fiber optic receiver

8

ST connector for fiber optic transmitter

9

C LED: G.703 signal present

10

RX LED: Receiving binary 0 via fiber optic

 

 

A

Power connector

 

 

*Both LEDs lit: Unit is in remote loop mode.

9