Prior to installation, this air-conditioningunit must be submitted for approval by the utility service which provides electricity (EN6055-3Norm).

IMP OR T ANT

€ P leas e read this owner's manual carefully and thoroughly before ins talling and operating your room air conditioner.

P leas e retain this owner's manual for future reference after reading it thoroughly.

Room Air Conditioner Owner’s Manual

TABLE OF CONTENTS

Safety Precautions.........................

3

Prior to Operation ..........................

9

Introduction ..................................

10

Electrical Safety ...........................

11

Operating Instructions.................

12

Maintenance and Service ............

26

FOR YOUR RECORDS

Write the model and serial numbers here:

Model #

Serial #

You can find them on a label on the side of each unit.

Dealer's Name

Date Purchased

Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call for service at all.

PRECAUTION

Contact the authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

The air conditioner is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.

Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.

2 Room Air Conditioner

Safety Precautions

Safety Precautions

To prevent the injury of the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

■ The meanings of the symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

Installation

Do not use damaged power cords, plugs, or a loose socket.

There is risk of fire or electric shock.

For electrical work, contact

Always use the power plug

the dealer, seller, a qualified

and socket with the ground

electrician, or an Authorized

terminal.

Service Center.

• There is risk of fire or electric

• There is risk of electric shock.

shock.

 

Install the panel and the

Do not modify or extend the

Do not install, remove, or

cover of control box

power cord.

re-installthe unit by

securely.

 

yourself (customer).

• There is risk of fire or electric

• There is risk of fire or electric

• There is risk of fire, electric

shock.

shock.

shock, explosion, or injury.

ENGLISH

Owner's Manual 3

Safety Precautions

Be cautious when

For installation, always

unpacking and installing

contact the dealer or an

the product.

Authorized Service Center.

• Sharp edges could cause injury.

• There is risk of fire, electric

Be especially careful of the

shock, explosion, or injury.

case edges and the fins on the

 

condenser and evaporator.

 

Be sure the installation area

Do not let the air conditioner

does not deteriorate with

run for a long time when the

age.

humidity is very high and a

 

 

 

 

 

 

door or a window is left open.

• If the base collapses, the air

• Moisture may condense and

conditioner could fall with it, causing

wet or damage furnishings.

property damage, product failure,

 

 

 

 

 

 

and personal injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not install the product on a defective installation stand.

It may cause injury, accident, or damage to the product.

Operation

Take care to ensure that power cords could not be pulled out or damaged during operation.

There is risk of fire or electrical shock.

Do not place anything on the power cord.

There is risk of fire or electric shock.

Do not turn the air-conditionerON or OFF by plugging or unplugging the power plug.

There is risk of fire or electrical shock.

4 Room Air Conditioner

Safety Precautions

Use a dedicated outlet for this appliance.

There is risk of fire or electrical shock.

Do not allow water to run into electric parts.

It may cause There is risk of fire, failure of the product, or electric shock.

Grasp the plug to remove the cord from the outlet. Do not touch it with wet hands.

There is risk of fire or electrical shock.

Do not store or use flammable gas or combustibles near the air conditioner.

There is risk of fire or failure of product.

Do not place a heater or other appliances near the power cable.

There is risk of fire and electric shock.

Do not use the product in a tightly closed space for a long time.

• Oxygen deficiency could occur.

ENGLISH

Wax

Thinner

When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. DO NOT use the telephone or turn switches on or off.

Unplug the unit if strange sounds, odors, or smoke comes from it.

• There is risk of explosion or fire. • There is risk of electrical shock or fire

Stop operation and close the window in storm or hurricane. If possible, remove the air conditioner from the window before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

Owner's Manual 5

Safety Precautions

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product failure.

Unplug the appliance before performing cleaning or maintenance.

When the product is soaked

Ventilate the product from

(flooded or submerged),

time to time when operating

contact an Authorized

it together with a stove, etc.

Service Center.

 

• There is risk of fire or eletric

• There is risk of fire or electrical

shock.

shock.

When the product is not be

Take care to ensure that

used for a long time,

nobody could step on or fall

disconnect the power supply

onto the outdoor unit.

plug or turn off the breaker.

 

• There is risk of electrical shock. • There is risk of product damage or failure, or unintended operation.

This could result in personal injury and product damage.

Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

Low refrigerant levels may cause failure of product.

 

 

 

 

 

 

 

 

 

Install the drain hose to

Keep level even when

ensure that water is drained

installing the product.

away properly.

 

• A bad connection may cause

• To avoid vibration or water

water leakage.

leakage.

90˚

6 Room Air Conditioner

Safety Precautions

Do not install the product

Use two or more people to

where the noise or hot air

lift and transport the air

from the outdoor unit could

conditioner.

damage the neighborhoods.

• It may cause a problem for your • Avoid personal injury. neighbors.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Operation

Do not direct airflow at room occupants. (Don't sit in the draft.)

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

• This could damage your health. • There is risk of damage or loss of property.

Use a soft cloth to clean. Do

Do not touch the metal

not use harsh detergents,

parts of the product when

solvents, etc.

removing the air filter. They

 

are very sharp!

• There is risk of fire, electric

• There is risk of personal injury.

shock, or damage to the plastic

 

parts of the product.

 

Do not block the inlet or outlet of air flow.

• It may cause product failure.

Do not step on or put anyting on the product. (outdoor units)

There is risk of personal injury and failure of product.

ENGLISH

Owner's Manual 7

Safety Precautions

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.

Do not insert hands or other

Do not drink the water

objects through the air inlet

drained from the unit.

or outlet while the air

 

conditioner is plugged in.

 

• There are sharp and moving

• It is not sanitary and could

parts that could cause personal

cause serious health issues.

injury.

 

Use a firm stool or ladder when cleaning or maintaining the air conditioner.

• Be careful and avoid personal injury.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

• There is risk of fire or explosion

Disuse

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

8 Room Air Conditioner

Prior to Operation

Prior to Operation

PreparingforOperation

1.Contact an installation specialist for installation.

2.Plug in the power plug properly.

3.Use a dedicated circuit.

4.Do not use an extension cord.

5.Do not start/stop operation by plugging/unplugging the power cord.

6.If the cord/plug is damaged, replace it with only an authorized replacement part.

Usage

1.Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time.

2.Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with stoves or other heating devices.

3.Do not use this air conditioner for non-specifiedspecial purpose (e.g. preserving precision devices, food, pets, plants, or art objects). Such use may damage your properties.

CleaningandMaintenance

1.Do not touch the metal parts of the unit when removing the filter. Injury can occur.

2.Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.

3.When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is triggered while cleaning inner parts of the unit.

Service

For repair and maintenance, contact your authorized service dealer.

ENGLISH

Owner's Manual 9

Introduction

Introduction

SymbolsusedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.

Indoor

Air Inlet

Front Panel

Air Filter

Signal Receptor

Outdoor

Air Intake Vents

Connecting

Wires

Piping

Air Outlet Vents

Base Plate

Drain Hose

 

10 Room Air Conditioner

Electrical Safety

Electrical Safety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• This appliance must be properly grounded.

ENGLISH

 

To minimize the risk of electric shock, you must alway plug into a grounded oulet.

 

 

 

• Do not cut or remove the grounding prong from the power plug.

 

 

• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance

 

 

unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the

 

 

house wiring.

 

 

• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and

 

 

circuit checked by a qualified electrician.

 

 

 

 

Temporary

 

Use

 

 

of

 

an

 

Adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,

 

use only a UL-listedadapter, available from most local hardware stores. Ensure that the large slot in the

 

adapter is aligned with the large slot in the receptacle for a proper polarity connection.

 

To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground

 

terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Never use the appliance with a broken adapter.

 

 

 

 

 

 

Temporary

 

Use

 

of

 

an

 

Extension

Cord

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

We strongly discourage the use of an extension cord due to potential safety hazards. For temporary

 

situations, use only CSA certified and UL listed 3-wiregrounded extension cords, rated 15 A, 125 V.

 

Owner's Manual 11

Operating Instructions

Operating Instructions

HowtoinserttheBatteries

1. Remove the battery cover by pulling it according to the arrow

direction.

2. Insert new batteries making sure that the (+) and (-)of battery are installed correctly.

3. Reattach the cover by sliding it back into position.

NOTICE

Use 2 AAA(1.5volt) batteries.

Do not use rechargeable batteries.

StorageandTipsforusingtheRemoteController

The remote controller may be stored by mounting it on a wall.

To operate the room air conditioner, aim the remote controller at the signal receptor.

Signal Receptor

Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)

Operation Indication Lamps

On/Off

Sleep Mode

Timer

Defrost Mode

OUT OUTDOOR UNITDOOR OPERATION

88 Display

PLASMA Plasma

:Lights up during the system operation.

:Lights up during Sleep Mode Auto operation. (Without plasma model only)

: Lights up during Timer operation. Lights up during Sleep Mode Auto operation.

(Plasma model only)

: Lights up during Defrost Mode or *Hot Start operation (Heat pump model only)

: Lights up during outdoor unit operation.

(Cooling model only)

 

: Indicates the setting temperature

Operation indicating

 

lamps

: Lights up during plasma operation (Plasma model only)

 

*Hot Start operation: Stops the indoor fan in Heating Operation to prevent cold air from blowing out from unit.

12 Room Air Conditioner

Operating Instructions

RemoteControlOperations

The controls will look like the following.

Controls

Signal transmitter

5 1 6

 

 

 

3

4

 

 

 

2

 

CANCEL

10

 

 

 

 

9

7

OFF

SET

ON

12

11

 

AUTO CLEAN

 

 

 

8

 

 

17

13

 

 

14

 

 

 

15

 

 

16

Flip-updoor (opened)

1.START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

2.OPERATION MODE SELECTION BUTTON

Used to select the operation mode.

3. ROOM TEMPERATURE SETTING BUTTONS

Used to select the room temperature.

4. INDOOR FAN SPEED SELECTOR

Used to select fan speed in four steps low, medium, high and CHAOS.

5. JET COOL

Used to start or stop the speed cooling.(speed cooling operates super high fan speed in

cooling mode.)

6. CHAOS SWING BUTTON

Used to stop or start louver movement and set the desired up/down airflow direction.

7.ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping operation. (See page 22)

8.TIME SETTING BUTTONS

Used to adjust the time. (See page 22)

9.TIMER SET/CANCEL BUTTON

Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 22)

10.SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation. (See page 22)

11.AIR CIRCULATION BUTTON

Used to circulate the room air without cooling or heating. (See page 23)

12.ROOM TEMPERATURE CHECKING BUTTON

Used to check the room temperature.

Operation Mode

Cooling Operation

Auto Operation or Auto Changeover

Healthy Dehumidification Operation

Heating Operation

13.NEO PLASMA(OPTIONAL)

Used to start or stop the plasma-purificationfunction. (See page 20)

14.HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL)

Used to set the desired horizontal airflow direction.

15.RESET BUTTON

Used prior to resetting time.

16.2nd F Button

Used prior to using modes printed in blue at the bottom of buttons. (See page 21)

• Cooling Model( ), Heat Pump Model( )

17. AUTO CLEAN (OPTIONAL)

 

Used to set Auto Clean mode.

ENGLISH

Owner's Manual 13

Operating Instructions

Cooling operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Cooling

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification

(Heat pump model only)

3

Close the door of the remote controller. Set the temperature

lower than the room temperature. The temperature can be

 

set within a range of 18°C~30°C at intervals of 1°C.

ON

To raise the temperature

 

 

To lower the temperature

4

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low,medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Natural wind by the CHAOS logic

For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

14 Room Air Conditioner

Auto operation (Optional)

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instructions

ENGLISH

2

Open the door of the remote controller. To select Auto

Operation, press the operation mode selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification

(Heat pump model only)

ON

3

The temperature and fan speed are automatically set by the

electronic controls based on the actual room temperature. If

you want to change the set temperature, press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will be changed automatically.

To raise the temperature

To lower the temperature

For this operation A1 appears on the display (Cooling plasma model only)

During Auto Operation

You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.

If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting.

During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing,press the chaos swing button again.

Owner's Manual 15

Operating Instructions

Auto changeover operation(Optional)

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Auto Changeover

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification

(Heat pump model only)

Close the door of the remote controller. Set the temperature 3 lower than the room temperature. The temperature can be

set within a range of 18°C~30°C at intervals of 1°C.

To raise the temperature

ON

 

To lower the temperature

4

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low,medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

During Auto changeover Operation

The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room temperature within ±2°C with respect to setting temperature by auto changeover mode.

16 Room Air Conditioner

Operating Instructions

Healthy dehumidification operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Healthy

Dehumidification Operation, press the Operation Mode

Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

ENGLISH

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification

(Heat pump model only)

ON

3

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low,medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Natural wind by the CHAOS logic

For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the

CHAOS logic.

During Healthy Dehumidification Operation

If you select the dehumidification mode on the operation selection button, the product starts to run the dehumidification function. It automatically sets the room temp. and airflow volume to the best condition for dehumidification, based on the sensed current room temp.

In this case, however, the setting temp. is not displayed on the remote controller and you are not able to control the room temp. either.

During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status, so that the room condition is kept healthy and comfortable even in the very humid season.

Owner's Manual 17

Operating Instructions

Heating operation (Heat pump model only)

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Open the door of the remote controller. To select Heating

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

Changeover

Dehumidification (Heat pump model only)

3

Close the door of the remote controller.

Set the temperature higher than the room temperature.

 

The temperature can be set within a range of 16°C~30°C at

 

intervals of 1°C.

ON

To raise the temperature

 

 

To lower the temperature

4

Set the fan speed again with the door of the

remote controller still closed. You can

select the fan speed in four steps–low,medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Natural wind by the CHAOS logic

For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

18 Room Air Conditioner

Operating Instructions

Jet cool operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2

Press the Jet Cool button to operate

the speed cooling mode and the unit

 

will operate at super high fan speed

 

on cooling mode for 30 minutes.

 

For this operation P0 appears on the

 

display. (Plasma model only)

3

To cancel the Jet Cool mode, press theJet Cool button, the

fan speed button or the room temperature setting button

again and the unit will operate at high fan speed on cooling mode.

or or

ENGLISH

NOTICE

During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. quickly in a hot summer.

In heat pump mode or auto changeover mode, however, the JET COOL function is not available.

In order to return to the normal cooling mode from the JET COOL mode, just press the operation mode selection button, airflow volume selection, temp. setting button or the JET COOL button again.

Owner's Manual 19

Operating Instructions

NEO PLASMA purification operation(Optional)

1

Press the Start/Stop button.

The unit will respond with a

beep.

2

Open the door of the remote

controller. Press the PLASMA

button.

Operation will start when the button is pressed and stop when the button is pressed again.

Make sure the plasma led lights up.

Set the fan speed again with the door of the remote

3 controller closed. You can select the fan speed in foursteps-low,medium, high or CHAOS.

Each time the button is pressed, the fan speed mode is shifted.

Air purifying operation (NEO PLASMA) can be with cooling, Heating or any other operations.

NEO PLASMA Air Purifying Operation only

If you press the only PLASMA button, only

PLASMA purification function operates.

Then, fan speed is low. You can select the fan speed in four steps-low,medium, high or

CHAOS.

Each time the Indoor Fan Speed Selector button is pressed, the fan speed mode is shifted.

20 Room Air Conditioner

2nd F operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instructions

ENGLISH

2

Open the door of the remote controller and press the 2nd

Function button to operate functions printed blue color under

buttons.

(Check the indication of 2nd function on the display of the remote controller.)

CANCEL

ONOFFSET

AUTO CLEAN

3

2nd function disappears in a short time automatically or when

the button is pressed again.

For more details, refer to functions next pages.

Owner's Manual 21

Operating Instructions

AdditionalFeatures

Sleep mode

1.Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.

2.The Timer is programmed in one-hourincrements by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.

3.Make sure the Sleep Mode Auto LED lights up.

To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star () disappears from the operation display.

NOTICE

The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump only) for a comfortable sleep.

In cooling mode or healthy dehumidification mode:

The setting temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for a comfortable sleep.

Setting the time

1.Time can be set only when you press the Reset button. Having replacing the batteries, you should press the reset buttons to reset the time. Press the Start/Stop button.

2.Press 2nd F button and check if 2nd F icon is on.

3.Press the Time Setting buttons until the desired time is set.

CANCEL

4. Press the Timer SET button.

NOTICE

Check the indicator for A.M. and P.M.

Delay start/Pre-setstop

1.Make sure the time is set correctly on the display of the remote controller.

2.Press 2nd F button.

3. Press the ON/OFF Timer buttons to turn Timer on or off.

ON OFF

4. Press the Time Setting buttons until the desired time is set.

CANCEL

5. To set the selected time, press the Timer setting button aiming the remote controller at the signal receptor.

To cancel the timer setting

Check if 2nd F icon is off. CANCEL Press the Timer Cancel button aiming the remote controller at the signal receptor.(The timer lamp on the air conditioner and the display will go out.)

NOTICE

Select one of the following four types of operation.

with the unit running

 

Delay OFF Timer

Delay ON Timer

Delay OFF and ON Timer Delay ON and OFF Timer

22 Room Air Conditioner

Operating Instructions

Vertical Airflow Direction Control

The up/down airflow (Vertical Airflow) can be adjusted by using the remote control.

1.Press the Start/Stop button to start the unit.

2.Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.

NOTICE

If you press the Chaos Swing button, the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze.

Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner.

When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.

ENGLISH

Horizontal Airflow Direction Control (Optional)

The left/right(Horizontal Airflow) can be adjusted by using the remote control.

Press the Start/Stop button to start the unit.

Open the door on the remote control. Press the Horizontal Airflow Direction button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.

Air circulation mode

Circulates the room air without cooling or heating.

1.Press the Start/Stop button. the unit will respond with a beep.

2.Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector button, the fan speed is shifted from low to CHAOS and back to low again.

CHAOS Air

Fan speed is on low. Fan speed is on medium. Fan speed is on high.

NOTICE

CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

Owner's Manual 23

Operating Instructions

Auto clean (Optional)

AUTO CLEAN

NOTICE

1.Whenever you press the AUTO CLEAN button, Auto Clean Function will be reserved and cancelled.

2.Auto Clean function works before and after cooling or dehumidification mode.

For details, refer to the below points.

3.When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.

4.When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditionercirculates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation. It lasts for 30 minutes.

5.If you press the AUTO CLEAN button again during the product operation , Auto Clean function will be cancelled.

During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed.

During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are available.

Forced operation

Operation procedures when the remote control can't be used.

The operation will be started if the ON/OFF button is pressed.

If you want to stop operation, re-pressthe button.

 

 

 

 

ON/OFF

 

 

 

 

button

 

Cooling Model

 

Heat pump Model

 

 

Room Temp. 24°C

21°C Room Temp. < 24°C

Room Temp. < 21°C

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

Setting Temperature

22°C

22°C

23°C

24°C

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep".

If you want to stop the operation, re-pressthe button.

24 Room Air Conditioner

Operating Instructions

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

So there is no need of activating this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.

Helpful information

 

Fan speed and cooling capacity.

 

The cooling capacity indicated in the specification is the value

 

when the fan speed is set to high, and the capacity will be lower

High

at low or medium fan speed.

Speed

High fan speed is recommended when you wish to cool the room

 

quickly.

 

ENGLISH

NOTICE

Auto restart function has set enable as factory default.

But customer can set up by following this instruction.

To be disable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times.

To be enable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times.

Owner's Manual 25

Maintenance and Service

Maintenance and Service

Before performing any maintenance, turn off the main power to the system.

IndoorUnit

Grille, Case, and Remote Control

Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTICE

Air inlet vent Air outlet vent

Air filters

Supply power must be disconnected before cleaning the indoor unit.

 

 

(behind front panel)

Air filters

Vertical louver

Horizontal louver

 

 

 

The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary.

1.Pull the both sides and remove front panel.

2.Pull the filter tab slightly forward to remove the filter.

3.Clean the filter with a vacuum cleaner or warm, soapy water.

If dirt is conspicuous, wash with a solution of detergent in lukewarm water.

If hot water (40°C or more) is used, it may be deformed.

4.After washing with water, dry well in the shade.

5.Re-installthe air filter.

NEO PLASMA filter (Optional)

The NEO PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary.

1.After removing the air filters, pull slightly forward to remove the NEO PLASMA filter.

2.Clean NEO PLASMA filter with the vacuum cleaner.

If it is very dirty, wash it with water.

3.Note the cuts of electric discharge lines.

4.Re-installthe NEO PLASMA filter to the original position.

TRIPLE DEODORIZINGFilter

NEO PLASMA Filter

TRIPLE DEODORIZER filter (Optional)

1.After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZER filter.

2.Dry in the sunlight for two hours.

3.Re-installthe TRIPLE DEODORIZER filter to the original position.

Don't touch this NEO PLASMA Filter within 10 seconds after opening he inlet grille, it may cause an electric shock.

Never use any of the followings:

Water hotter than 40°C

Could cause deformation and/or discoloration.

Volatile substances

Could damage the surfaces of the air conditioner.

s

o

line

26 Room Air Conditioner

Maintenance and Service

Replacement of purifying filter (Optional)

Recomended use period : About 2 years

1. Remove front panel and air filters.

2.Remove air purifying filters.

3.Insert new air purifying filters.

Air filter

TRIPLE DEODORIZINGFilter

2

3

4. Reinsert air filters and close front panel.

ENGLISH

OutdoorUnit

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.

If clogged with dirt or soot, the heat exchanger

and panel vents may be professionally steam cleaned.

NOTICE

Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

(Rear)

Air intake (Side) vents

Air outlet vents

Piping

Drain Hose

Owner's Manual 27

Maintenance and Service

CommonProblemsandSolutions

Before calling for service

If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.

Air conditioner does not operate

1.Ensure that the air conditioner is plugged into a proper outlet.

2.Check the fuse or circuit breaker.

3.Check whether the voltage is unusually high or low.

Air does not feel cold enough on the cooling setting

1.Ensure that the temperature settings are correct.

2.Check to see if the air filter is clogged with dust. If so, replace the filter.

3.Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20" between the back of the air conditioner and the wall or fence behind it.

4.Close all doors and windows and check for any source of heat in the room.

Before calling for service, please review the following list of common problems and solutions.

The air conditioner is operating normally when:

You hear a pinging noise. This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.

You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit.

You hear the fan running while the compressor is silent. This is a normal operational feature.

28 Room Air Conditioner

Maintenance and Service

Troubleshooting

The air conditioner may be operating abnormally when:

Problem

 

Possible Causes

 

What To Do

 

 

 

 

 

 

 

 

 

 

Air conditioner does not start

The air conditioner is unplugged.

The fuse is blown/circuit breaker is tripped.

Power failure.

Make sure the air conditioner plug is pushed completely into the outlet.

Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.

If power failure occurs, turn the mode control to Off.

When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

Air conditioner does not cool as it should

Airflow is restricted.

The air filter is dirty.

The room may have been hot.

Cold air is escaping.

Cooling coils have iced up.

Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.

Clean the filter at least every 2 weeks. See the care and Maintenance section.

When the air conditioner is first turned on, you need to allow time for the room to cool down.

Check for open furnace floor registers and cold air returns.

See Air Conditioner Freezing Up below.

ENGLISH

Owner's Manual 29