B&B Electronics EIR608-xSFP User Manual

Size:
1.67 Mb
Download

Product Description

Model EIR608-xSFP

Documentation Number: EIR608-xSFP_0708m

707 Dayton Road --P.O. Box 1040--Ottawa, IL 61350 USA

Phone (815) 433-5100--General Fax (815)433-5105

Phone (815)433-5100--General Fax (815)433-5105

Website: www.bb-elec.com

Sales e-mail:orders@bb-elec.com --Fax (815)433-5109

Technical Support e-mail:support@bb.elec.com --Fax (815)433-5104

European Headquarters

B&B Electronics

Westlink Commercial Park --Oranmore, Co. Galway, Ireland

Phone +35391-792444--Fax +35391-792445

Website: www.bb-europe.com

Sales e-mail: sales@bb-europe.com

Technical Support e-mail: support@bb-europe.com

© 2008 B&B Electronics Mfg. Co. Inc. - Revised February 2008

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445www.bb-europe.com

Eight Port Managed Industrial

Ethernet Switches

User Manual

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445www.bb-europe.com

FCC

This Equipment has been tested and found to comply with the limits for a Class-Adigital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

CE

This is a Class-Aproduct. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Manual Documentation Number: EIR608-xSFP_0708M

Table of Contents

vii

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444– Fax +35391-792445www.bb-europe.com

Content

Overview.....................................................................

1

Introduction...............................................................

1

Features ...................................................................

2

Packing List..............................................................

4

Hardware Description................................................

5

Dimensions (W x D x H)...........................................

5

Front Panel...............................................................

5

Top View ..................................................................

6

Wiring the Power Inputs ...........................................

6

LED Indicators..........................................................

7

Ports .........................................................................

8

Cabling .....................................................................

9

Mounting Installation...............................................

13

DIN-RailMounting..................................................

13

Panel Mounting ......................................................

14

Hardware Installation...............................................

15

Installation Steps....................................................

15

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445www.bb-europe.com

X-RingApplication..................................................

16

Coupling Ring Application ......................................

17

Dual Homing Application........................................

17

Console Management..............................................

18

Connecting to the Console Port .............................

18

Pin Assignment ......................................................

18

Login in the Console Interface ...............................

19

CLI Management....................................................

20

Commands Level .............................................................

21

Commands Set List ..........................................................

22

System Commands Set....................................................

22

Port Commands Set .........................................................

24

Trunk Commands Set ......................................................

27

VLAN Commands Set ......................................................

28

Spanning Tree Commands Set ........................................

30

QOS Commands Set........................................................

33

IGMP Commands Set.......................................................

33

Mac / Filter Table Commands Set ....................................

34

SNMP Commands Set .....................................................

35

Port Mirroring Commands Set ..........................................

37

Manual Documentation Number: EIR608-xSFP_0708M

Table of Contents

ix

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444– Fax +35391-792445www.bb-europe.com

802.1x Commands Set.....................................................

38

TFTP Commands Set.......................................................

40

SystemLog, SMTP and Event Commands Set.................

40

SNTP Commands Set ......................................................

42

X-ringCommands Set ......................................................

43

Web-BasedManagement ........................................

45

About Web-basedManagement ............................

45

Preparing for Web Management ............................

45

System Login..........................................................

45

Main interface.........................................................

46

System Information ................................................

47

IP Configuration......................................................

47

DHCP Server – System configuration....................

48

DHCP Client Entries...............................................

48

DHCP Server - Port and IP Bindings .....................

49

TFTP - Update Firmware........................................

49

TFTP – Restore Configuration ...............................

50

TFTP - Backup Configuration.................................

50

System Event Log – Syslog Configuration.............

51

System Event Log - SMTP Configuration ..............

52

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445www.bb-europe.com

System Event Log - Event Configuration

............... 53

Fault Relay Alarm...................................................

54

SNTP Configuration ...............................................

55

IP Security..............................................................

58

User Authentication................................................

59

Port Statistics .........................................................

59

Port Control ............................................................

60

Port Trunk...............................................................

61

Aggregator setting ............................................................

61

Aggregator Information.....................................................

63

State Activity.....................................................................

64

Port Mirroring..........................................................

65

Rate Limiting ..........................................................

66

VLAN configuration ................................................

67

VLAN configuration - Port-basedVLAN ...........................

67

802.1Q VLAN ...................................................................

70

Rapid Spanning Tree .............................................

73

RSTP - System Configuration ..........................................

73

RSTP - Port Configuration................................................

74

Manual Documentation Number: EIR608-xSFP_0708M

Table of Contents

xi

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444– Fax +35391-792445www.bb-europe.com

SNMP Configuration...............................................

75

System Configuration .......................................................

76

Trap Configuration............................................................

77

SNMPV3 Configuration ....................................................

77

QoS Configuration..................................................

81

QoS Policy and Priority Type............................................

81

Port Base Priority .............................................................

82

COS Configuration ...........................................................

82

TOS Configuration............................................................

83

IGMP Configuration................................................

83

X-Ring ....................................................................

84

Security ..................................................................

87

802.1X/Radius Configuration............................................

87

MAC Address Table .........................................................

90

Factory Default.......................................................

92

Save Configuration.................................................

93

System Reboot.......................................................

93

Trouble shooting......................................................

94

Technical Specification...........................................

95

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445www.bb-europe.com

Overview

Introduction

This managed industrial switch comes equipped with a proprietary redundant network protocol—X-Ringwhich provides an easy way to establish a redundant Ethernet network. With ultrahigh-speedrecovery time (less than 300 ms) and a long MTBF (Mean Time Between Failures) the industrial switch will continue to operate until a Gigabit network infrastructure has been established, without requiring extra upgrade costs.

In addition to10/100/1000Base-TXfast Ethernet ports, the switch has SFP(mini-GBIC)ports. TraditionalRJ-45ports can be used for up linking short distance (less than 100 m)wide-bandpaths, while the SFP slots can be used for the application of wideband uploading and long distance transmissions adding flexibility.

Manual Documentation Number: EIR608-xSFP_0708m

1

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444– Fax +35391-792445www.bb-europe.com

Features

4 x 10/100/1000Base-TMbps Ethernet ports

4 x SFP (mini-GBIC)port (support 100/1000 Dual Mode)

Full/half duplex flow control

Auto-negotiation

MDI/MDI-Xauto-crossover

Packet Buffer up to 1Mbits

MAC Address up to 8Kbytes

Surge (EFT) protection (3,000 VDC for power line)

Ethernet EDS protection (4,000 VDC)

Power Supply

¾Wide-rangeRedundant Power Design

¾Reverse Polarity Protection

¾Overload Current Protection

Case/Installation

¾IP-30Protection

¾DIN Rail and Panel Mount Design

Spanning Tree

¾IEEE802.1d Spanning Tree

¾IEEE802.1w Rapid Spanning Tree

VLAN

¾Port Based VLAN

¾802.1 Q Tag VLAN

¾GVRP

¾Double Tag VLAN (Q in Q)*

¾Private VLAN**

X-Ring

¾X-Ring,Dual Homing, Couple Ring and Dual Ring Topology

¾Provide redundant backup feature and the recovery time below 300ms

Port Trunk with LACP

802.1ab LLDP**

QoS (Quality of Service)

¾IEEE 802.1p Class of Service

¾4 Priority queues per port

¾Port Base, Tag Base and Type of Service Priority

Bandwidth Control

¾Ingress Packet Filter and Egress Rate Limit

¾Broadcast/Multicast Packet Filter Control

2

Manual Documentation Number: EIR608-xSFP_0708m

 

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444– Fax +35391-792445www.bb-europe.com