Remote Data Collection Device CE

Model DCDSS1

Documentation Number DCDSS11702

This product designed and manufactured in Ottawa, Illinois USA of domestic and imported parts by

International Headquarters

B&B Electronics Mfg. Co. Inc.

707 Dayton Road --P.O. Box 1040--Ottawa, IL 61350 USA

Phone (815) 433-5100--General Fax (815)433-5105

Home Page: www.bb-elec.com

Orders e-mail:orders@bb-elec.com --Fax (815)433-5109Technical Supporte-mail:support@bb.elec.com --Fax (815)433-5104

European Headquarters

B&B Electronics Ltd.

Westlink Commercial Park, Oranmore, Co. Galway, Ireland

Phone +353 91-792444--Fax +35391-792445

Home Page: www.bb-europe.com

Orders e-mail: orders@bb-europe.com

Technical Support e-mail:support@bb-europe.com

2002 B&B Electronics July 2001 --Revised May 2002

Documentation Number DCDSS11702 Manual Cover Page

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

B&B Electronics RESERVED. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of B&B Electronics.

B&B Electronics shall not be liable for incidental or consequential damages resulting from the furnishing, performance, or use of this manual.

All brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder.

Table of Contents

 

Chapter 1: Introduction ....................................................

1

Chapter 2: Operation .........................................................

2

Data Storage.........................................................................

2

Data Buffer and Time Stamping ..............................

2

Polling Strings..........................................................

2

Data Delivery Triggers ..........................................................

2

Time-BasedTrigger .................................................

2

Buffer-BasedTrigger ...............................................

3

Digital Input Trigger .................................................

3

Data Delivery Methods .........................................................

3

Error Conditions....................................................................

3

Serial Ports ...........................................................................

4

ISP Account ..........................................................................

4

Email Setup ..........................................................................

5

FTP Setup.............................................................................

5

Pager Setup..........................................................................

5

Time Setup ...........................................................................

6

Bypass Mode ........................................................................

6

Remote Buffer Retrieval (New! May 2002) ...........................

6

Local Buffer Retrieval (New! May 2002)……………………... 8

 

Chapter 3: Setup ................................................................

8

Firmware Updates ................................................................

8

Chapter 4: Specifications..................................................

9

Appendix A: Declaration of Conformity .......................

A-1

Documentation Number DCDSS11702 Manual

Table of Contents

i

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

Chapter 1: Introduction

B&B Electronics iCaddy is a serial data collection device that uses the Internet to automatically deliver your data. Data is emailed or sent using FTP based on a user-programmableschedule or when its buffer level is reached or based on a digital alarm input.

It replaces local or long distance phone calls with an automated Internet connection to your Internet Service Provider. Instead of calling out to remote sites, let the DCDSS1 deliver the data to you, virtually anywhere, anytime!

Once installed, there is no need for human presence at the remote site. You can download cash receipts at midnight or track distant conditions at any time. The DCDSS1 works with a modem to call a local ISP near your remote location. User-friendlysoftware witheasy-to-readscreens allows you to set automaticcall-insfrom multiple locations. You can changecall-intimes and data requests at any time from your central PC.

Documentation Number DCDSS11702 Manual

Appendix A

1

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

Chapter 2: Operation

Data Storage

Data Buffer and Time Stamping

The DCDSS1 has a 60 Kbyte data buffer for storing data collected through the local serial port and time stamp information. The time stamp can be enabled to record the time that the data came into the local serial port. A new time stamp is created when new data is received after one minute of inactivity.

Polling Strings

Many serial devices require data to be requested before responding. The DCDSS1 can be programmed with up to 10 polling strings, each string up to 35 bytes in length. Each polling string is individually configured and sent out of the local serial port on a timebased trigger. In the PC setup software, fields are chosen to schedule the polling interval of each polling string for minutes, hours and days. Instead of a fixed interval, you can also select which day of the month the polling string should be sent to the local device.

Data Delivery Triggers

The DCDSS1 will automatically connect through your ISP to deliver its data and notifications. Three different types of events can trigger the data delivery.

Time-BasedTrigger

The time-basedtrigger can beuser-configuredto deliver data based on time and date. For example, data may be delivered once every hour, at 9:00 p.m. each Sunday, or on the first day of each month. In the PC setup software, fields are chosen to schedule the delivery interval for minutes, hours and days. Instead of a fixed interval, you can also select which day of the month that data should be delivered.

2

Appendix A

Documentation Number DCDSS11702 Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

Buffer-BasedTrigger

The buffer-basedtrigger automatically dials the modem after the data buffer is a determined percentage full. The range is from 10% to 80% in 5% increments. Keeping the buffer trigger below 100% capacity allows for additional data to be stored while the connection is being made.

Digital Input Trigger

The digital input trigger dials the modem when an input signal is detected on the DCDSS1 digital input. It is a +5 volt signal, which can be set to active high or active low. The signal must stay active for at least 5 milliseconds to be detected.

Data Delivery Methods

Data and error logs can be emailed using a MIME attachment or sent using FTP. Additionally, notifications can be configured to allow email or pager notification that data has been delivered.

Error Conditions

The DCDSS1 has a 2.9 Kbyte error log buffer for storing error conditions. Each error condition is time stamped.

 

Error Condition Logged

 

Cause

 

 

 

 

Data received from the local serial

 

BYTE(S) LOST

port during ISP communications or

 

 

when in Bypass Mode is not stored

 

DATA OVERRUN

Onboard UART FIFO overflowed

 

 

 

DATA ERROR

Character received with parity,

 

 

 

framing or break error

 

 

 

 

 

 

 

 

An error occurred in the email

 

 

 

NOTIFICATION FAILED

notification process (mail server

 

 

 

connection, command structure,

 

 

 

 

 

 

 

 

etc.)

 

 

 

 

 

An error occurred in the email data

 

DATA ATTACHMENT FAILED

process (mail server connection,

 

 

 

 

command structure, etc.)

 

 

 

ERROR ATTACHMENT

An error occurred in the email error

 

log process (mail server connection,

 

FAILED

 

command structure, etc.)

 

 

 

 

 

 

 

FTP FAILED

An error occurred in the FTP

 

 

 

process (FTP server connection,

 

 

 

 

 

 

 

 

 

 

 

 

 

Documentation Number DCDSS11702 Manual

Appendix A

3

 

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

 

command structure, etc.)

PAGER FAILED

Unable to contact pager or send

message

 

DATA OVERFLOW

Data buffer filled, most recent data

stored

 

ERROR OVERFLOW

Error buffer filled, most recent errors

stored

 

PRIMARY DIALUP FAILED

Unable to connect to ISP1

PRIMARY AUTHENTICATION

Unable to verify

FAILED

username/password with ISP1

SECONDARY DIALUP

Unable to connect to ISP2

FAILED

 

SECONDARY

Unable to verify

AUTHENTICATION FAILED

username/password with ISP2

Serial Ports

The DCDSS1 has two serial ports. One connects to the modem; the other is for collecting the serial data.

The modem side serial port is always set up for 8 data bits, one stop bit, and no parity bit. The baud rate for the modem side serial port can be set from 600 to 115.2 kbps. A 60-byteinitialization string can be programmed to be sent to the modem before the ISP number is dialed. This port is configured as a DTE device; a standard serial modem cable should be used to connect it to a modem.

The local serial port can be configured for 5 – 8 data bits, 1 or 2 stop bits, and even, odd or no parity. The baud rates for the local serial port can be set from 300 baud to 115.2k baud. This port is set up as DTE and supports TD and RD data lines.

ISP Account

The DCDSS1 allows for a primary and secondary (backup) ISP account. If the DCDSS1 is unable to connect to the primary ISP, three attempts will be made before switching to the secondary ISP for that delivery. Subsequent deliveries will revert back to the primary ISP.

Note: The DCDSS1 supports Password Authentication Protocol (PAP)for logging into the ISP. Challenge Handshake Authentication Protocol (CHAP)is not supported by the DCDSS1. The user must supply a user name and password for each ISP account. The user name and password are limited to 30 bytes each. Note that AOL, Netzero, Juno, MSN, Earthlink, and others use non-standard protocols and cannot be used with the DCDSS1.

4

Appendix A

Documentation Number DCDSS11702 Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

Email Setup

The DCDSS1 allows for a primary and secondary mail server. The primary mail server is used when the primary ISP is dialed. The secondary mail server is used when the secondary ISP is dialed. For the primary and secondary mail servers, the IP address, port number and MIME filename need to be supplied by the user.

The DCDSS1 stores up to ten email addresses for notification and delivering the collected data. The email addresses can be up to 50 bytes each. A user email address for the reply field is also limited to 50 bytes. The subject for the DCDSS1’s email will be <the event> <the trigger> <user defined ID>. The user defined ID can be up to 32 characters long. Some sample subject lines are listed below.

<data><buffer> SWfieldPump#1 <error><time>StorageTank4 <notification><digital>WestEntrance

FTP Setup

The DCDSS1 allows for a primary and secondary FTP server. The primary FTP server is always tried first. If the primary FTP server fails, the secondary FTP server is used. Both the primary and secondary FTP servers require the FTP server’s IP address, port number, FTP username, FTP password, file name, and pathname for the data file. The username and password can be up to 30 bytes each; the pathname can be up to 50 bytes. The filename can be up to 10 bytes long, and can be set to increment each time a file is downloaded by adding a two-digitnumber to the beginning of the filename.

Pager Setup

The DCDSS1 allows for one numeric pager to be dialed. The numbers dialed and message sent, including pauses and spaces, can be up to 50 characters long. The pager can be dialed any time one of the modem triggers has been tripped to notify that an event has occurred.

Documentation Number DCDSS11702 Manual

Appendix A

5

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

Time Setup

The DCDSS1 setup software uses the local clock from the computer to set the time during configuration. You can adjust the time and date using the supplied configuration software. The DCDSS1 keeps track of the hour, minute, day, month, year, and day of the week. It can also be set up to automatically adjust for daylight savings time.

Bypass Mode

The DCDSS1 features a Bypass Mode that allows you to make direct modem connections to the remote device. When the DCDSS1 detects an incoming call from the modem from your software, it automatically switches to bypass mode, allowing you to communicate directly to the remote serial device.

Remote Buffer Retrieval (New! May 2002)

The DCDSS1 now features a remote buffer retrieval mode. This feature allows the user to manually the gather data or error stored in the buffer at any time remotely. This mode usesmodem-to-modemcommunication, so a modem and a simple emulation program (like SimpTerm, downloadable fromwww.bb-elec.com)are necessary. Instructions:

1)Connect the local modem to an available COM port.

2)Open the emulation program of choice.

3)Raise/set DTR and RTS.

4)Dial the number that iCaddy’s modem is on (like “ATDT 18454335100<carriage return>”) and wait for confirmation of connection. If successful, go on to 5. If not, lower DTR and go back to 3.

5)You must know the password in order to go any further. The password must be received within the first 100 bytes to get into this mode. Otherwise, this is a standard bypass mode. Next, type “!RT” (read time command). You should have received 3 bytes if successful. If not, re-enter password.

6)Type “!DA” for the data buffer.

7)Type “!EL” for the error buffer.

8)Type “!##” to exit. Please be sure you receive the initialization string before exiting to confirm the unit has rebooted. If not, try “!##” again.

9)Lower DTR and RTS to disconnect.

6

Appendix A

Documentation Number DCDSS11702 Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445

Local Buffer Retrieval (New! May 2002)

The DCDSS1 also features local buffer retrieval mode. This feature allows the user to manually gather the data or error stored in the buffer at any time locally. This mode is very similar to the remote buffer retrieval method. However, it does not require a modem. It still requires a simple emulation program (like SimpTerm, downloadable fromwww.bb-elec.com).

Instructions:

1)Do not remove power from iCaddy at any time during these steps. Doing so will erase the data and error buffers.

2)Connect an available COM port to the modem side of iCaddy using a null modem cable.

3)Open the emulation program of choice and set the speed the same as iCaddy’s modem port baud rate.

4)Raise/set DTR to set DCD (pin 1) of iCaddy’s modem port.

You must know the password in order to go any further. The password must be received within the first 100 bytes to get into this mode. Otherwise, this is a standard bypass mode. If successful, you should see the modem LED come on solid. Note that the power LED should have been solidly lit already.

5)Type “!DA” for the data buffer.

6)Type “!EL” for the error buffer.

7)Type “!##” to exit. Please be sure you receive the initialization string before exiting to confirm that the unit has rebooted. If not, try “!##” again.

8)Lower DTR to disconnect.

Documentation Number DCDSS11702 Manual

Appendix A

7

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100- Fax815-433-5104B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +35391-792444– Fax +35391-792445