Barco MIVD 1218 User Manual

Size:
667.37 Kb
Download

B4100337 / 02

November 2003

© 2003 BARCO NV. All rights reserved

MIVD 1218

BarcoView

Theodoor Sevenslaan 106

8500 Kortrijk, Belgium

Phone: +32(0)56 23 32 44

Fax: +32(0)56 23 33 74

E-mail:sales.medical@barco.com

http://www.barcoview.com

User Manual

BarcoView Inc

3059 Premiere Parkway

Duluth, Georgia, 30097,USA

Phone: +1 678 475 8000

Fax: +1 678 475 8100

E-mail:sales.medical@barco.com

http://www.barcoview.com

BarcoView LTD

16F-1,Cheng Loong Plaza 33, Min Sheng Road

Section 1, Pan Chiao, Taipei Hsien, Taiwan, R.O.C.

Phone: +886 2 2957 8357

Fax: +886 2 2957 4080

Safety instructions

Read the safety and operating instructions before operating the apparatus.

Retain safety and operating instructions for future reference.

Adhere to all warnings on the apparatus and in the operating instructions manual. Follow all instructions for operation and use.

This apparatus conforms to: CE, IEC601-1,UL2601-1,

CAN/CSA-C22.2No.601.1-M90(c UL)

Usage in Hazardous locations Class I equipment

Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.

FCC notice

This equipment has been tested and found to comply with the limits of a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

!Power connection

Power cord: Utilize a UL-listeddetachable power cord,3-wire,type SJ or equivalent, 18 AWG min., rated 300 V min., provided

with a hospital-gradetype plug5-15Pconfiguration for 120V application, or6-15Pfor 240V application.

Warning: This apparatus must be earthed! Power requirements: connect the apparatus to an AC voltage as indicated at its back. Using a lower voltage, the apparatus will not be able to operate. Using a higher voltage may damage the apparatus.

If you are not sure of the type of power supplied, consult the power company.

Do not overload wall outlets and extension cords as this may result in fire or electric shock.

Mains lead protection (U.S.: Power cord): Supply cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them, paying particular attention to cords at plugs and receptacles.

Water and moisture

Never expose the apparatus to rain or moisture.

Never use the apparatus near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry tub or in a wet basement.

Ventilation

Do not cover or block the ventilation openings in the cover of the set. When installing the apparatus in a cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard.

Installation

Place the apparatus on a flat, solid and stable surface that can bear the weight of at least 3 monitors. If you use an unstable cart or stand, the set may fall, causing serious injury to a child or adult, and

serious damage to the equipment.

More warnings in the Installation chapter.

User manual MIVD 1218

3

Contents

 

Safety instructions ..............................................................................................

3

Contents.............................................................................................................

4

1.

Overview.......................................................................................................

6

 

1.1. Introduction .............................................................................................

6

 

1.2. Package contents ...................................................................................

7

 

1.3. Controls and connectors .........................................................................

7

2.

Installation ....................................................................................................

9

 

2.1. Precautions .............................................................................................

9

 

2.2. Mounting the display (model without tilt & swivel foot option) ................

9

 

2.3. Portrait or landscape position (model with tilt & swivel foot option).........

9

 

2.4. Connecting the signals..........................................................................

10

 

2.5. Routing the signal cables (model with tilt & swivel foot option) .............

12

 

2.6. Tilt and swivel positioning (model with tilt & swivel foot option).............

13

 

2.7. Starting up.............................................................................................

13

3.

Operation....................................................................................................

14

 

3.1. Introduction ...........................................................................................

14

 

Navigating through the menus .................................................................

14

 

Saving changes .......................................................................................

14

 

3.2. Controlling contrast and brightness.......................................................

15

 

3.3. Controlling the light output ....................................................................

16

 

3.4. Calibrating the display...........................................................................

17

 

3.5. Getting information................................................................................

19

 

General information .................................................................................

19

 

Timing information ...................................................................................

20

 

3.6. Adjusting Geometry...............................................................................

20

 

3.7. Settings .................................................................................................

21

 

Input Selection .........................................................................................

22

 

Test Pattern .............................................................................................

22

 

Lookup Tables .........................................................................................

22

 

Filter.........................................................................................................

23

 

Power Led................................................................................................

23

 

ALC active ...............................................................................................

23

 

DPMS ......................................................................................................

23

 

De-interlacing...........................................................................................

23

 

3.8. Advanced settings.................................................................................

24

User manual MIVD 1218

4

 

OSD.........................................................................................................

24

 

ALC..........................................................................................................

25

 

Scan mode...............................................................................................

26

 

Control wheel...........................................................................................

26

 

3.9. Service ..................................................................................................

27

4.

Maintenance ...............................................................................................

28

 

Panel........................................................................................................

28

 

Cabinet ....................................................................................................

28

 

To remove the glass panel:......................................................................

28

 

Cleaning instructions:...............................................................................

28

5.

Troubleshooting..........................................................................................

29

 

Calibration not successful ........................................................................

29

 

Pixel Faults ..............................................................................................

29

6.

Technical specifications..............................................................................

30

 

GEOMETRY ............................................................................................

30

 

VISUAL PERFORMANCE .......................................................................

30

 

INPUTS....................................................................................................

30

 

SCANNING SYSTEM ..............................................................................

30

 

CONTROLS.............................................................................................

31

 

POWER SUPPLY ....................................................................................

31

 

APPROVALS ...........................................................................................

31

 

DIMENSIONS ..........................................................................................

31

User manual MIVD 1218

5

1. Overview

1.1. Introduction

Flat panel displays are quickly becoming the standard in modalities such as interventional radiology, endoscopy, laparoscopy and ultrasound applications.

Barco’s 18" MIVD 1218 grayscale flat panel display module offers flexibility and digital scan conversion for use in modalities.

The panel, featuring an RS232 interface, has a resolution of 1280 x 1024 and complies with worldwide medical approvals.

The accurate signal conversion and wide range of interfacing options of the MIVD’s dedicated circuitry guarantee image fidelity.

The MIVD 1218 further offers LUT correction, which allows setting the panel’s transfer curve to viewing standards like DICOM or CRT.

Options

Portrait Accelerator (PA)

The Portrait Accelerator automatically adapts the orientation of the image to the physical orientation of the display panel. The system makes it possible to display a portrait resolution image on a portraitoriented display without additional software.

Tilt & swivel foot

The tilt & swivel foot allows ideal positioning of the panel, in height and viewing angle.

Most of the photos in this manual show the model with the tilt & swivel foot option.

Memory scan modes

The memory of the display contains maximum 200 fixed and 28 programmable scan modes.

When you connect a video signal, the display checks in the memory for a matching scan mode.

If it finds one, it selects the corresponding settings and parameters from the memory. If it does not find a matching scan mode, the display uses default settings to display the image.

When you make adjustments and save the changes, the current scan mode is saved as programmable scan mode. If this happens while all programmable scan modes are occupied, the oldest programmable scan mode is overwritten automatically.

User manual MIVD 1218

6

1.2. Package contents

The package should include the following items, please check. If some of the items are missing, please contact the reseller from whom you have purchased the unit.

-The MIVD 1218 display

-4 screws to mount the display to a bracket

-European power cord

-American power cord

-This user manual

1.3.Controls and connectors

1

2

(1)Ambient Light Compensation (ALC) sensor

(2)Power LED

-The LED is off when the display is off or disabled in the on-screenmenus.

-The LED is green when the display is on (when enabled in the onscreen menus).

-The LED is orange when the display is in Stand-bypower-savingmode.

User manual MIVD 1218

7

Connector not used

3

(3)Control wheel for navigating through the on-screendisplay (OSD) menus and changing values in the menus

RS232

DVI

VIDEO

CS/HS

VS

Power

(SERVICE ONLY)

Input panel at the rear

4

5

6

7

8

9

(4)Control (rs-232)connector

Note: To comply to EMC regulations, the used RS-232cable must be provided with a ferrite core.

(5)DVI (video and data) input

(6)Composite video input

(7)Composite / Horizontal sync input

(8)Vertical sync input

(9)AC power input

User manual MIVD 1218

8

2.Installation

2.1.Precautions

Keep your original packaging. It is designed for this display and is the ideal protection during transport.

Avoid reflections in the flat panel to reduce eye strain.

Place the display on a strong and stable table or desk.

Keep the display away from heat sources and provide enough ventilation in case it is built in a rack or console.

Make sure all equipment is switched off before connecting the signals.

2.2.Mounting the display

(model without tilt & swivel foot option)

The standard display comes without tilt & swivel foot.

It is provided with 4 holes in the rear cover to mount the display to a “Vesa 100 mm” standard mounting bracket.

100 mm

Screws: 4 screws M4 x 8 mm

100mm

2.3.Portrait or landscape position (model with tilt & swivel foot option)

You can change the orientation of the panel at any time, but it is more convenient to select landscape or portrait orientation before connecting the cables.

Important:

In the factory, the height-positioningsystem in the display foot is blocked with a strap to prevent damage during transportation.

Before installing the display, you must remove this strap.

User manual MIVD 1218

9

To remove the strap:

1Position the display with its rear side facing you.

2If the foot cover is mounted on the foot, lift up the 2 clips of the foot cover to release the cover from the foot.

3Pull the lower side of the cover towards you and simultaneously slide the cover downward.

4Pull the red strap out of the fixation holes in the foot.

Strap

To change the panel orientation:

1Stand at the front side of the panel and take the panel at both sides.

2Very important: Tilt the panel before changing the orientation.

Should you change the panel orientation without tilting it first, you might irreversibly damage the tilt & swivel mechanism.

3To change from portrait to landscape, turn the panel counterclockwise while tilting it slightly.

To change from landscape to portrait, turn clockwise.

2.4.Connecting the signals

To get access to the connectors, open the cover of the connector compartment by pulling down the 2 clips of the cover.

To connect DVI signals:

1Connect one end of the DVI cable to the DVI input (5) of the display.

2Connect the other end of the DVI cable to the video output of your DVI signal source.

3Rout the cable so that it enters the connector compartment at the place where the cover is bulged.

User manual MIVD 1218