The Back-UPS ES indicates operating status using a combination of visual and audible indicators. Use the following table to identify the status of the Back-UPS ES.
Status Indicators

®

Back-UPS® ES 350/550

www.apc.com

User Guide

 

Connect Battery

1For safety, the Back-UPS ES is shipped with one battery wire disconnected. The Back-UPS ES will not operate until the wire is connected to the touch safe battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.

1

TURN the Back-UPS ES over and

slide the battery compartment

cover off of the battery housing.

2

LIFT the battery out of the compartment and connect the black wire to the negative (-) battery

terminal. Ensure the batteries are installed as shown below.

Slide the battery compartment cover 3 completely onto the Back-UPS ES.

Back-UPS ES 350

Back-UPS ES 550

2

Battery Backup Surge Protection

These outlets are powered whenever the Back-UPS ES is switched ON. During a power outage or other utility problems

Connect Equipment

Place the Back-UPS ES to avoid:

- Direct sunlight - Excessive heat - Excessive humidity or contact with fluids

Plug the Back-UPS ES power cord directly into a wall outlet; not a surge protector or power strip.

(brownouts, over-voltages), these outlets will be powered for a limited time by the Back-UPS ES. Plug your computer, monitor, and two other data-sensitive devices (external disk or tape drive) into these outlets.

®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

w w w.apc.com

 

 

 

 

 

 

 

 

AC LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CORD

 

 

 

 

 

Battery Backup

Surge Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect FAX/Modem/Phone

Back-UPS ES protects a single line (2-wire) fax, modem or phone from surges when it is connected through the Back-UPS ES as shown.

Connect Computer Cable

The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage.

Connect the cable to the Data Port of the Back-UPS ES. Connect the other end of the cable to the USB port on your computer. The software will automatically find the USB Port of your computer.

 

Surge Protection Only

 

 

 

POWER ON/

Back-UPS ES

BUILDING WIRING

 

 

5 5 0

 

 

 

 

 

 

REPLACE BATTERY

 

FAULT INDICATOR

Wiring

CAUTION - Refer to bottom

INDICATOR

Replace Battery

 

 

Power On

 

Building

 

 

 

FROM WALL JACK

Fault

of unit for safety markings.

 

 

Wall

 

 

Push to Reset

 

 

 

 

Circut Breaker

 

 

 

Outlet

 

 

 

DATALINE OUTPUT TO

Phone/Fax

 

 

 

DSL MODEM or PHONE

Modem/

 

 

 

 

 

 

 

 

Data Port

 

Surge Protection Only

TO COMPUTER

CIRCUIT BREAKER

These outlets provide full-time protection from surges even if

USB PORT

PUSH TO RESET

 

 

 

the Back-UPS ES is switched OFF. Plug your printer, fax

 

 

 

machine, scanner, or other peripherals that do not need

 

 

 

battery power into these outlets.

 

 

 

3Power On and

Install Software

Press the ON/OFF switch to power the unit ON.

A single short beep and the green “Power On” indicator confirms that Back-UPS ES is on and ready to provide protection.

The Back-UPS ES should charge for at least 16 hours to ensure sufficient runtime. The unit is being charged whenever it is connected to utility power, whether the unit is turned ON or OFF.

If the red Building Wiring Fault indicator (located on the end near the power cord) is lit, your building wiring presents a shock hazard that should be corrected by a qualified electrician.

Install the PowerChute Personal® Edition software

Place the PowerChute Personal Edition CDROM into your computer and follow the installation instructions on the screen.

Status

Visual Indications

Audible Indication

Alarm Terminates

 

(Power On - Green)

 

When

 

(Replace Battery - Red)

 

 

 

 

 

 

Power On - UPS is supplying conditioned

Power On LED - ON

None

Not applicable.

utility power to the load.

 

 

 

 

 

 

 

 

 

On Battery - UPS is supplying battery

Power On LED

- ON (off

Beeping 4 times every

UPS transfers back to

power to the load connected to the Battery

during beep)

 

30 seconds

Power On operation, or

outlets.

 

 

 

when UPS is turned off.

 

 

 

 

 

Low Battery Warning - UPS is supplying

Power on LED

- flashing

Rapid beeping (every

UPS transfers back to

battery power to the load connected to the

 

 

1/2 second)

normal operation, or

Battery outlets and the battery is near

 

 

 

when UPS is turned off.

exhaustion.

 

 

 

 

 

 

 

 

Replace Battery - The battery is

Replace Battery LED -

Constant tone

UPS turned off with the

disconnected.

flashing

 

 

power switch.

The battery is in need of charging or is at

Power On and Replace

Constant tone

 

the end of its usual life and must be

Battery LEDs-

Flashing

 

 

replaced.

(alternating)

 

 

 

 

 

 

 

 

Overload Shutdown - During On Battery

None

 

Constant tone

UPS turned off with the

operation a battery power supplied outlet

 

 

 

power switch.

overload was detected.

 

 

 

 

 

 

 

 

 

Sleep Mode - During On Battery operation

None

 

Beeping once every 4

Utility power is restored,

the battery power has been completely

 

 

seconds

or if utility power is not

exhausted and the UPS is waiting for utility

 

 

 

restored within 32

power to return to normal.

 

 

 

seconds, or the UPS is

 

 

 

 

turned off.

 

 

 

 

Building Wiring Fault - Your building

Building Wiring Fault LED

None

UPS is unplugged, or is

wiring presents a shock hazard that should

(red) - ON

 

 

plugged into a properly

be corrected by a licensed electrician.

 

 

 

wired outlet.

 

 

 

 

 

See the Troubleshooting section for additional assistance.