APC 990-5520B User Manual

Broadband CTEP/G Series
Zero, Three, Six Battery Pole/Ground Mount Enclosures
Four, Eight Battery Pole Mount Enclosures
120 V/240 V
User Manual

Chapter 1 General Information
The CTEP/G Series Enclosures provide power sourcing for broadband cable operations.
Safety
This Safety Guide contains important instructions that should be followed during installation and maintenance of the APC equipment and batteries. It is intended for APC customers who setup, install, relocate, or maintain APC equipment.
Only trained service personnel should install and maintain the power supply enclosure.
Changes and modifications to this unit not expressly approved by APC could void the warranty.
Failure to observe these warnings may result in serious injury, death or damage to the equipment.
Electrical
Warnings
Battery
Warnings
Overhead
Warnings
Do not work alone under hazardous conditions.
Do not handle any metallic connector before the power has been disconnected.
Servicing this equipment may require working with protective covers removed and utility power connected. Use extreme caution during these procedures.
High current through conductive materials could cause severe burns.
When grounding cannot be verified, disconnect the equipment from the utility power outlet before installing or connecting to other equipment. Reconnect the power cord only after all connections are made.
Check that the power cord(s), plug(s), and sockets are in good condition.
Replacement of fuses or other parts must be with identical types and ratings. Substitution of nonidentical parts may cause safety and fire hazards.
Always replace batteries with same or equivalent type recommended by the manufacturer.
Danger of explosion if battery is incorrectly connected or replaced.
Batteries present a risk of electrical shock and burns from high current in the event of a
Batteries must be recycled. Deliver the battery to an appropriate recycling facility or ship it to the supplier in the new battery packing material.
Never stand underneath a unit while it is hoisted. Always wear a hard hat.
Lifting Warnings Modules are heavy. Use proper lifting techniques and equipment to avoid injury.
1
Chapter 2 Installation
Prior to installing the power supply enclosure, a utility breaker box must be installed on the pole. Utility line voltage must be routed to the enclosure. Local, state, federal and/or National Electric Code (NEC) regulations regarding location, permits and electrical wiring must be adhered to.
Do not operate the power supply where the temperature and humidity are outside the specified limits. See Specifications in this manual.
Models Supported
Model Number | Description |
Encl, Pole 0 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Pole 3 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Pole 3 Batt 20 A, 120 Vac, 60 Hz with Generator Interface | |
|
|
Encl, Pole 3 Batt 20 A, 240 Vac, 60 Hz | |
|
|
Encl, Pole 4 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Pole 4 Batt 20 A, 120 Vac, 60 Hz with Generator Interface | |
|
|
Encl, Pole 4 Batt 20 A, 240 Vac, 60 Hz | |
|
|
Encl, Pole 4 Batt 20 A, 240 Vac, 60 Hz with Generator Interface | |
|
|
Encl, Pole 6 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Pole 6 Batt, 20 A, 120 Vac, 60 Hz with Generator Interface | |
|
|
Encl, Pole 8 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Pole 8 Batt, 20 A, 120 Vac, 60 Hz with Generator Interface | |
|
|
Encl, Pole 8 Batt 20 A, 240 Vac, 60 Hz | |
|
|
Encl, Pole 8 Batt, 20 A, 240 Vac, 60 Hz with Generator Interface | |
|
|
Encl, Ground 0 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Ground 3 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Ground 3 Batt 20 A, 240 Vac, 60 Hz | |
|
|
Encl, Ground 6 Batt 20 A, 120 Vac, 60 Hz | |
|
|
Encl, Ground 6 Batt, 20 A, 120 Vac, 60 Hz with Generator Interface | |
|
|
2
Specifications
Environmental Specifications
Operating Temperature | |
|
|
Humidity | 5% to 95% noncondensing within enclosure |
|
|
Physical Specifications
Characteristic | Specification |
Height X Width X Depth | 14” x 24” x 16” (36 x 61 x 41 cm) |
CTEP0 | |
CTEP3 | 30” x 24” x 16” (76 x 61 x 41 cm) |
CTEP4 | 27” x 29” x 18” (67 x 72 x 45 cm) |
CTEP6 | 39” x 24” x 16” (99 x 61 x 41 cm) |
CTEP8 | 38” x 29” x 18” (96 x 72. x 45 cm) |
Height X Width X Depth |
|
CTEG0 | 22” x 24” x 16” (56 x 61 x 41 cm) |
CTEG3 | 38” x 24” x 16” (97 x 61 x 41 cm) |
CTEG6 | 47” x 24” x 16” (119 x 61 x 41 cm) |
Weight |
|
CTEP/G0 | 23 lbs (10 kg) |
CTEP/G3 | 50 lbs (23 kg) |
CTEP4 | 78 lbs (34.5 kg) |
CTEP/G6 | 77 lbs (35 kg) |
CTEP8 | 140 lbs (63.6 kg) |
Unpacking
Inspect the unit upon receipt. Notify the carrier if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly.
Check the package contents. The package contains the enclosure, battery cables, connectors and associated hardware, and product documentation.
CTEP/G3: (5 cables) | 15” black battery jumpers (2), 24” black (1), 27” red (2), 34” red (1) |
CTEP/G6: (9 cables) | 15” black battery jumpers (4), 25” black (1), 40” black (1), 60” black (1), |
| 27” red (1), 34” red (1) |
|
|
CTEP4: (6 cables) | 15” black battery jumpers (3), 30” black (1), 27” red (2), 40” red (1) |
|
|
CTEP8: (11 cables) | 15” black battery jumpers (6), 30” black (1), 40” black (1), 27” red (1), |
| 40” red (1) |
|
|
3

Installing the Enclosure
Models may vary in appearance from those depicted below.
Install the Mounting Bracket on a Pole
CTEP0/CTEP4 models | CTEP3/CTEP6/CTEP8 models |
Install the Enclosure on the Mounting Bracket
CTEP0/CTEP4 models
Secure the bolts, nuts, and washers on the mounted bracket prior to installing the enclosure.
CTEP3/CTEP6/CTEP8 models
Secure the bolts, nuts, and washers on the mounted bracket prior to installing the enclosure.
4

Ground Mount Installation
1.Install an APC approved concrete pad. Contact your dealer or refer to the APC Web site, www.apc.com for more information.
2.Secure the enclosure to the pad. Refer to the diagrams below.
0 Battery Enclosure:
Attach the ground skirt to the concrete pad.
3 Battery, 6 Battery Enclosures:
Place the enclosure on the pad. The holes on the enclosure must be aligned with the anchor hooks on the pad, (hardware not included).
This is a general representation of an enclosure mounted on a pad. Configurations may vary.
Attach the enclosure to the ground skirt.
| Service Entrance/ |
Meter Base | Load Center |
Coax Housing | Coax Housing |
|
5

Wiring
Grounding
1.Install and interconnect ground rods appropriate for proper grounding according to local electrical code requirements.
2.Route ground wires from the ground system into the bus bar located on the enclosure.
Connecting Utility Power to the Enclosure |
|
|
|
CTEP/G3 | CTEP/G0 | ||
(CTEP/G6&CTEP8 have additional battery tray) |
|
|
|
Tamper Switch |
|
|
|
Present on all Models |
| Status Monitoring Lamp | |
|
| ||
Site for Power Supply |
|
| Present on all Models |
|
|
| |
Battery Tray |
|
|
|
| Grounding Wire | ||
Electrical Input Output Box | Output Connection to Coax | ||
|
|
| |
| Optional External AC | ||
| Generator Interface | ||
Maintenance Bypass Switch | To CTSP Utility | ||
| |||
Auxiliary Power | Output Terminals | ||
|
|
| |
Supply Connection | Output Voltage Sensor |
1.Unlock and open the door of the enclosure.
2.Ensure that the utility power switch is OFF.
3.Install a high magnetic circuit breaker box
4.Using appropriate conduit connectors, run wires from the utility breaker box to the receptacle box inside the enclosure.
5.Connect the wires to the receptacle and install it in the enclosure.
6.Refer to the
6

Options
An optional External AC Generator Interface is available for the following models:
For available options see your dealer or the APC Web site, www.apc.com.
Connecting the Batteries
The battery circuit breaker must OFF prior to battery installation.
Use normal precautionary measures when wiring and connecting the batteries.
Tape one end of each jumper cable prior to installation.
CTEP/G3
Bottom Shelf
Top Shelf
7

CTEP/G6
Bottom Shelf
Middle Shelf
Top Shelf
8