Operation

Display Interface

Using the display interface

Use the display interface on the front of the G5BLK to configure and operate the unit.

Power. Push to apply power to the unit or to shut off power to the unit.

Status. Push to display the current status of the unit, including the current input/output voltage.

Setup. Push to scroll through the setup menus.

Up/Down. Push to change values (Setup menu) and browse menu pages (Status menu).

Display interface LEDs

There are eleven LEDs on the display interface.

LED

Illuminated

Not Illuminated

 

 

 

POWERON

The unit is supplied with utility

There is no input utility power.

 

power.

 

 

 

 

LINEOK

The utility power is within

The input voltage from utility power is outside the

 

acceptable range, 92 V to 140 V.

acceptable range and the unit has disconnected from

 

 

utility power to protect the connected equipment.

 

 

 

PROTECTION

The unit is protecting all connected

The unit is not providing power protection. See

WORKING

equipment.

Troubleshooting and contact APC Technical Support

 

 

immediately.

 

 

 

WIRINGOK

The unit is functioning properly.

There is a problem with the building wiring. Contact a

 

 

certified electrician.

 

 

 

OVERLOAD

The unit is overloaded. Disconnect

The unit is functioning properly.

 

some connected components.

 

 

Contact APC Technical Support.

 

 

 

 

DELAY1

Power is being supplied to DELAY1.

Power is not being supplied to DELAY1.

 

 

 

DELAY2

Power is being supplied to DELAY2.

Power is not being supplied to DELAY2.

 

 

 

DELAY3

Power is being supplied to DELAY3.

Power is not being supplied to DELAY3.

 

 

 

DELAY4

Power is being supplied to DELAY4.

Power is not being supplied to DELAY4.

 

 

 

SWITCHED

Power is being supplied to the

Power is not being supplied to the SWITCHED outlet.

 

SWITCHEDoutlet.

 

 

 

 

ALWAYSON

Power is being supplied to the

Power is not being supplied to the ALWAYS ON outlets.

 

ALWAYSONoutlets.

See “Troubleshooting” on page 10 and contact APC

 

 

Technical Support immediately.

 

 

 

APC A/V G-TypeRack Power Filter: Operation

5

Status menu

Note: The menus shown in this manual are for reference only. Information displayed on the unit may be different than shown here.

Utility Source, Voltage and Frequency.

UTILITY SOURCE 120V 60Hz

Current and Percentage.

TOTAL OUTPUT 12A 80%

Contact Information.

1-888-8827228WWW.APCAV.COM

Model and Serial Number.

G5 POWER FILTER

SN: AB1234567890

Firmware version.

FW REVISION: 860.M1.D

Recent Faults.

NO FAULT

FAULT CONDITION

Description

Setup menu

Note: The menus shown in this manual are for reference only. Information displayed on the unit may be different than shown here.

Use the Setup menus to configure the unit. There are nine setup menus. Push SETUP to scroll to the next menu.

LCD dimmer. Set the brightness of the display.

DISPLAY DIMMER:

NORMAL

6

APC A/V G-TypeRack Power Filter: Operation

LED dimmer. Set the brightness of the LED.

LED DIMMER:

DIM1

Delay1. Select the number of seconds for the delay.

DELAY 1: 4SEC (1-60)

Delay2. Select the number of seconds for the delay.

DELAY 2: 4SEC (1-60)

Delay3. Select the number of seconds for the delay.

DELAY 3: 4SEC (1-60)

Delay4. Select the number of seconds for the delay.

DELAY 4: 4SEC (1-60)

Cut-Off Voltage. Select the maximum and minimum voltage. The unit will protect connected equipment from high and low voltages that are not safe for operation.

MAX UPPER VOLT: 140V (132-140)

MIN LOWER VOLT: 92V (92-100)

Language. Select the language for the display: English, French, or Spanish. PushSETUP to go to the

next screen, RESET TODEFAULT.

MENU LANGUAGE:

ENGLISH

Restore default settings. SelectYES orNO to restore the default settings.

RESET TO DEFAULT

YES

Lock the unit

The unit can be locked to prevent unwanted access. To lock or unlock the unit, push STATUS andDOWN for three seconds.

G5BLK LOCKED

APC A/V G-TypeRack Power Filter: Operation

7

Save screen as default

To save a screen as the default, push STATUS for three seconds.

THIS SCREEN IS

SAVED AS DEFAULT

Shut down the unit

Push and hold the POWER button.

POWERING DOWN

8

APC A/V G-TypeRack Power Filter: Operation