AMX Dimmer Enclosures w-Breakers RDA-ENC6B User Manual

Size:
225.67 Kb
Download

Installation Guide

RDA-ENC6B and ENC12B Dimmer Enclosures w/Breakers

The RDA-ENC6B(FG606-13)andRDA-ENC12B(FG606-14)enclosures provide secure mounting for all AMX Lighting and ProLink controllers, and lighting modules. These enclosures contain circuit breakers.

TOP VIEW

 

 

 

0.75"

 

 

 

 

 

 

(19.05 mm)

 

 

 

 

 

 

 

 

 

6.0"

(152.4 mm)

These enclosures are CE, UL, and C-ULapproved. They include circuit breakers and terminals formulti-phasewiring.

They also provide 18 knockouts for 1/2", 3/4", and 1" conduits.

RDA-ENC6BConfigurations:

-ENC6B/120 20 A Breakers

-ENC6B/240 10 A Breakers

 

 

RDA-ENC12BConfigurations:

SIDE VIEW

 

- ENC12B/120 20 A Breakers

 

- ENC12B/240 10 A Breakers

 

 

 

 

 

 

 

 

 

 

 

 

RDK Configurations:

 

 

 

 

 

 

 

 

 

 

- RDK-ENC6Bwith 1RDC-PDC

 

 

 

 

 

 

 

 

 

 

- RDK-ENC12B/2402RDC-PDC

 

 

 

 

 

 

 

 

 

 

 

24.0"

 

 

24.0"

 

 

(610 mm)

(610 mm)

 

 

 

RDA-ENC6B

 

 

 

 

 

 

 

RDA-ENC12B

Sample RDK-ENC12Bkit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shown with 2 RDC-PDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18.0" (457.2 mm)

Top, side, and bottom views are the same for both enclosures.

BOTTOM VIEW

Note:

LINE INPUTS: 120 A MAX PER TERMINAL Use 75° C copper conductors only.

Torque terminals to 44 in-lbs.

FIG. 1 Top, front, bottom, and side views of theRDA-ENC6BandRDA-ENC12Benclosures

Installation Instructions:

For indoor use only.

Mount on vertical surface only.

Maintain 12" (304.88 mm) minimum clearance above and below the enclosure.

Route class 1 conductors through upper conduit knockouts.

Route class 2 conductors through lower conduit knockouts.

Use 75°C (167°F) copper conductors only.

Install filler plate #28-10500(RDA-EFP)in all unused openings.

Install only UL approved modules (see the UL Number Cross Reference to AMX Lighting ID table on page 2).

Enclosure Weights:

RDA-ENC6B:16.5 lbs. (7.48 kg)

RDA-ENC12B:17.5 lbs. (7.94 kg)

Dimensions between center lines (from FIG. 2):

RDA-ENC6B:

A to B = 16.0" (406.4 mm)

B to C = 22.88" (581.2 mm)

RDA-ENC12B:

A to B = 16.0" (406.4 mm)

B to C = 22.88" (581.2 mm)

Radia enclosures must be mounted on a vertical surface with a minimum of 12" (304.8 mm) clearance above and below the enclosure.

Configuration for

 

right and left

A to B

mounting brackets

 

for all Radia

Top slot

enclosures.

 

 

B to C

Maximum mounting

 

screw size: #12

 

 

Bottom slot

FIG. 2 Bracket configuration

Specifications

Maximum input wire #1/0 AWG (50mm²)

Maximum line input is 120 A (per terminal)

Torque input wire to 44 in-lbs.(5.0 N/m)

Wire stripping length: 0.67 inches (17 mm)

Input 1 feeds channels 1, 4, 7, and 10

Input 2a feeds channels 5 and 11

Input 2b feeds channels 2 and 8

Input 3 feeds channels 3, 6, 9, and 12

Breakers are UL 489 listed 10,000 AIC, 100% Switching Duty, Hydraulic-Magnetic

The following section cross references the UL ID module numbers and AMX Lighting module IDs.

The modules identified are the only ones that can be used in the RDA-ENC6BandRDA-ENC12Benclosures.

UL Number Cross Reference to AMX Lighting ID

UL ID

AMX ID

UL ID

AMX ID

UL ID

AMX ID

 

 

 

 

 

 

28-10100

RDC-DC/120

28-10200

RDM-INC

28-10300

RDM-MR60

 

 

 

 

 

 

28-10110

RDC-DC/240

28-10210

RDM-2INC

28-10310

RDM-MDM

 

 

 

 

 

 

28-10120

RDC-DC/277

28-10220

RDM-INC50

28-10340

RDA-CHK

 

 

 

 

 

 

28-10130

RDC-PDC/120

28-10230

RDM-ZC,

28-10350

RDM-FDB

 

 

 

RDM-2ZC

 

RDM-2FDB

 

 

 

 

 

RDM-3FDB

 

 

 

 

 

RDM-HFDB

 

 

 

 

 

 

28-10133

RDC-PDC/240

28-10240

RDM-ZC50

28-10360

RDM-DPSM

 

 

 

 

 

 

UL Number Cross Reference to AMX Lighting ID (Cont.)

UL ID

AMX ID

UL ID

AMX ID

UL ID

AMX ID

 

 

 

 

 

28-10140

RDD-DM6/120

28-10260

RDM-SWM,

28-10370RDM-DC,

 

 

 

RDM-2SWM,

 

RDM-2DC,

 

 

 

RDM-3SWM

 

RDM-3DC

 

 

 

 

 

RDM-HDC

 

 

 

 

 

 

28-10150

RDD-DM6/240

28-10270

RDM-HSW,

 

 

 

 

 

RDM-2HSW,

 

 

 

 

 

RDM-3HSW

 

 

 

 

 

 

 

 

28-10160

RDD-DM6/277

 

 

 

 

 

 

 

 

 

 

28-10170

RDA-PSM/120

 

 

 

 

 

 

 

 

 

 

Lighting Application Drawings

Note:

LINE INPUTS: 120 A MAX PER TERMINAL

Use 75° C copper conductors only.

Torque terminals to 44 in-lbs.

FIG. 3 ENC6B and ENC12B Power Distribution

FIG. 4 ENC6B and ENC12B Input Terminal Block Wiring