AMX AXB-TM5 User Manual
Size:
256.33 Kb
Download

Programming

Programming

You can program the AXB-TM5to perform a wide variety of operations using Axcess Send_Commands. This section describes channel settings, IR functions, and system Send_Commands. Refer to theAXCESS Programming Guide for additional programming information.

Channel Setting Commands

The AXB-TM5use the channel setting commands listed in the following table.

AXB-TM5Channel Settings

Channel

Function

 

 

1

Generates IR/Serial functions 1, else Off

 

 

2 - 127

Channels the generate IR code for the corresponding functions

 

 

128 - 247

Push and release channels for received IR code

 

 

248

A push on this channel indicates a power failure error

 

 

249

Response LED blinks when channels 249 and 250 are On

 

 

250

Response LED lights when channel is On

 

 

251

I/O is On (switch to GND) when channel is On

 

 

252

I/O 2 is On (switch to GND) when channel is On

 

 

253

I/O 3 is On (switch to GND) when channel is On

 

 

254

I/O 4 is On (switch to GND) when channel is On

 

 

255

Channel is On if the TV Power Sensor detects a horizontal scan frequency

 

 

Turning a channel (IR/Serial function) on while another one is currently on will automatically turn the current one off first. Contact closure inputs on I/O 1 through I/O 4 will also generate PUSHes and RELEASEs on channels 251 through 254, respectively.

Device Assignment

The device assignment must be the same as the device number set on the Device DIP switches

(FIG. 2 on page 3).

AXB-TM5Television Manager

9