NetLinx® Integrated Controller

Controllers

Initial Release: / Last Revised: 1/8/2009

AMX Limited Warranty and Disclaimer

AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are warranted for a period of one (1) year.

Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.

Software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer.

AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of

liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX

Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full

determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.

 

Table of Contents

Table of Contents

 

Product Information ...........................................................................................

1

Front and Rear Panel Components ...........................................................................

1

Specifications............................................................................................................

2

Connections and Wiring .....................................................................................

5

Installing the Master or Hub Card.............................................................................

5

Preparing/connecting captive wires................................................................................

5

RS-232/422/485 Wiring Specifications......................................................................

5

Relay Connections and Wiring ..................................................................................

5

IR/Serial Connections and Wiring..............................................................................

6

Input/Output (I/O) Connections and Wiring..............................................................

6

Programming ......................................................................................................

7

Using the ID Button ..................................................................................................

7

Device:Port:System (D:P:S)..............................................................................................

7

Program Port Commands .........................................................................................

8

ESC Pass Codes ......................................................................................................

10

Notes on Specific Telnet/Terminal Clients ..............................................................

11

WindowsTM client programs.........................................................................................

11

Linux Telnet client .........................................................................................................

11

LED Disable/Enable Send_Commands ....................................................................

11

RS232/422/485 Ports Channels ..............................................................................

11

RS-232/422/485 Send_Commands .........................................................................

12

RS-232/422/485 Send_String Escape Sequences....................................................

15

IR / Serial Ports (8 - 15) Channels............................................................................

16

IR/Serial Send_Commands ......................................................................................

16

Input/Output Send_Commands ..............................................................................

21

NXI NetLinx Integrated Controller

i

 

 

Table of Contents

ii

NXI NetLinx Integrated Controller

 

 

Product Information

Product Information

The NXI NetLinx Integrated Controller represents the new generation of AMX multi-portcentral controllers. The NXI can be programmed to controlRS-232/422/485,Relay, IR/Serial, and Input/Output devices using the NetLinx programming language and NetLinx Studio program. Depending on your specific control needs, the NXI can be equipped with either a Master or Hub Card. For use as a master controller, the NXI accepts theNXC-ME260NetLinx Master Card.

Front and Rear Panel Components

Remove the faceplate to see the front panel (FIG. 1) containing groups of colored LED indicators that light when their corresponding control ports receive/ transmit data. These LEDs are grouped by control type, and are numbered according to their corresponding port (connector) numbers on the rear panel. The rear panel contains all of theRS-232/422/485,Relay, IR/Serial and I/O connectors, plus the ID pushbutton and ICSP LED. Figure 1 shows the front and rear panels of the NXI.

I/O LEDs (yellow)

IR/Serial LEDs (red)

Relay LEDs (red)

RS-232/422/485TX/RX LEDs

Master/Hub Card Slot

 

 

front

ICSP LED (green)

RS-232/422/485(ports1-6)

Relays (port 7)

 

Master/Hub Card Slot

IR/Serial (ports 8-15)

rear

 

I/O (port 16)

 

ID Pushbutton

 

FIG. 1 NXI front and rear panel components

 

NXI NetLinx Integrated Controller

1

 

 

Product Information

Specifications

NXI Specifications

Power requirements

1.09 A @ 12 VDC (NXI only/no card)

 

 

Memory

64K of IR memory:·

 

• 32K IR memory for IR ports 8-11

 

• 32K IR memory for IR ports 12-15

 

 

Ports:

 

RS-232/422/485ports(#1-6)

Six RS-232/422/485control ports with XON/XOFF (transmit on/transmit off),

 

and CTS/RTS (clear to send/ready to send), 300-230,400baud.

 

Channel range = 1-255

 

• Channels 1-254provide feedback only.

 

• Channel 255 (CTS Push channel): Reflects the state of the CTS Input if a

 

'CTSPSH' command was sent to the port.

Relay port (#7)

12-channelrelay port.

 

Channel range = 1-12

IR/Serial ports (#8-15)

8 IR/Serial control ports that support high-frequencycarriers up to 1.14 MHz.

 

Channel range = 1-32,767

 

• Channels 1-253(output): IR commands.

 

• Channel 254 (feedback): Power Fail (used with 'PON' and 'POF'

 

commands).

 

• Channel 255 (feedback): Power status (when IOLink is set).

I/O port (#16)

8-channelI/O port for contact closure,0-5VDC voltage sensing, or interac-

 

tive power sensing for IR ports.

 

Channel range = 1-8

 

 

Front panel components:

 

Card slot

Accepts NXC-ME260NetLinx Master or Hub card.

 

Hub Cards:

 

NXC-NH- Hub Card

 

NXC-HS- Hub Server Card

 

NXC-HE- Hub Expander Card

RS-232/422/485LEDs

6 sets of red and yellow LEDs light to indicate ports 1-6are transmitting or

 

receiving RS-232,422, or 485 data:

 

• TX LEDs (red) blink when transmitting data.·

 

• RX LEDs (yellow) blink when receiving data.

Relay LEDs

12 red LEDs light to indicate relay channels 1-12are active (closed).

IR/Serial LEDs

8 red LEDs light to indicate IR/Serial channels 1-8are transmitting control

 

data.

I/O LEDs

 

8 yellow LEDs light when I/O channels 1-8are active.

 

 

2

NXI NetLinx Integrated Controller

Product Information

NXI Specifications (Cont.)

Rear Panel Components:

 

RS-232/422/485(ports1-6)

Six 10-pin(male) connectors that supportbi-directionalRS-232/422/485

 

communication (XON/XOFF, CTS/RTS, 300-230,400baud).

 

• Channel range = 1-255

 

• Channels 1-254provide feedback only.·

 

• Channel 255 (CTS Push channel): Reflects the state of the CTS input if a

 

'CTSPSH' command was sent to the port.

Relay (port 7)

Three 8-pin(male) relay connectors (normally open) that support up to 12

 

independent external relay devices. Each relay can switch up to 24 VDC or

 

28 VAC @ 1 A.

 

• Channel range = 1-12

IR/Serial (ports 8-15)

Two 8-pin(male) connectors that support IR or serial (wired) IR control.

 

The eight IR/Serial control ports support high-frequencycarriers up to

 

1.14 MHz.

 

• Channel range = 1-32,767

 

• Channels 1-253:= IR commands

 

• Channel 254: = PowerFail (used with 'PON' and 'POF' commands)

 

• Channel 255: = Power status (when IOLink is set)

I/O (port 16)

8-channelI/O port for contact closure,0-5VDC voltage sensing, or interac-

 

tive power sensing for IR ports.

 

• The 10-pin(male) connector has inputs that detect0-1.5VDC (low) as a

 

Push, and 3.5-5VDC (high) as a Release.

 

• When used as an input, each of the eight I/O ports act as a switch to

 

ground and are rated at 200 mA @ 12 VDC.

 

• Channel range = 1-8

ICSP LED (green)

Blinks in unison with the Master card's NetLinx LED indicating the ICSP bus

 

is synchronized.

ID pushbutton

Sets the NetLinx ID (D:P:S) assignment for the NXI.

 

 

Enclosure

Metal with black matte finish

 

 

Front faceplate

Plastic gray faceplate with translucent viewing window

 

 

Weight

4.10 lbs (1.85 kg)

 

 

Dimensions (HWD)

1.72" x 17.0" x 8.80" (43.68 mm x 431.80 mm x 223.52 mm)

 

 

Included accessories

4 CC-NIRCIR Emitter cables

 

 

Optional accessories

• 12 VDC power supply

 

CC-N232RS-232/422cables

 

CC-NIRCIR cables

 

CC-NRELRelay cables

 

CC-NSERIR/Serial cables

 

 

NXI NetLinx Integrated Controller

3

 

 

Product Information

4