PRINCETON™ RECESS BATH W/ LUXURY
LEDGE AND INTEGRAL OVERFLOW
BARRIER FREE |
AMERICAST® BRAND ENGINEERED MATERIAL |
|
|
|
|
PRINCETON™ RECESS BATH W/ LUXURY
LEDGE AND INTEGRAL OVERFLOW
Americast® brand engineered material
2394.202 ICH (Chrome Trim) Left Hand Outlet2394.202 ICHTC Same as above with Tub Cover2395.202 ICH (Chrome Trim) Right Hand Outlet2395.202 ICHTC Same as above with Tub Cover
2394.202 IPB (Polished Brass Trim) Left Hand Outlet
2394.202 IPBTC Same as above with Tub Cover
2395.202 IPB (Polished Brass Trim) Right Hand Outlet
2395.202 IPBTC Same as above with Tub Cover
2394.202 IBS (Brushed Satin Trim) Left Hand Outlet
2394.202 IBSTC Same as above with Tub Cover
2395.202 IBS (Brushed Satin Trim) Right Hand Outlet
2395.202 IBSTC Same as above with Tub Cover
• Lift and turn drain stopper assembly included with bath
• Escutcheon included and installed on bath |
|
|
|
Photograph details integral overflow and drain |
|
• Acid resistant porcelain finish |
|
|
|
||
|
|
|
assembly. Drain assembly included with bath. |
||
• Recess bath with integral apron and |
|
|
|
||
|
|
|
|
||
tiling flange |
|
|
|
|
|
• Integral lumbar support |
|
To Be Specified: |
|||
• Beveled headrest |
|
||||
|
Color: |
||||
• Extra wide ledge for placement of toiletries |
|
||||
|
Bath Filler: (specify finish) |
||||
• Full slip-resistant coverage |
|
||||
|
Bath Drain: 1583.470 (specify finish) |
||||
• End drain outlet |
|
|
|
|
|
|
|
To Be Specified - Optional: |
|||
Nominal Dimensions: |
|
Pressure Test Kit†: 791363-0070A |
|||
1524 x 864 x 356mm |
|
|
|
|
|
|
*See faucet section for additional models available |
||||
(60" x 34" x 14") |
|
||||
|
† Pressure Test Kit is necessary to seal overflow and perform |
||||
|
|
||||
|
|
system pressure test. |
|||
Bathing Well Dimensions: |
|
|
|
|
|
1423 x 635 x 337mm |
|
Americast® brand engineered material is a composition of porcelain bonded |
|||
(56" x 25" x 13-1/4") |
|
to enameling grade metal, bonded to a patented structural composite. |
|||
|
|
|
|
||
Compliance Certifications - |
|
|
|
|
|
Meets or Exceeds the Following Specifications: |
|
|
|
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES |
|
• ASME A112.19.4 for Americast Plumbing Fixtures |
|
|
|
||
|
|
|
|||
|
|
|
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND |
||
• ASTM F-462 for Slip-resistant Bathing Facilities |
|
|
|
USEABLE BUILDING FACILITIES-CHECK LOCAL CODES. |
|
|
|
|
|||
• ANSI Z124.1 Ignition Test |
|
|
|
INSTALL WITH SEAT AT HEAD END. |
|
|
|
|
|
||
• ASTM E162 for Flammability |
|
SEE REVERSE FOR PRODUCT DIMENSIONS |
|||
• NFPA 258 for Smoke Density |
|
AND SPECIFICATIONS |
|||
|
H119 |
|
|||
© 2008 AS America Inc. |
Revised 2/08 |
||||
|
|
|