American Standard 0478.001, 0478.403, 0478.803 User Manual

0 (0)
American Standard 0478.001, 0478.403, 0478.803 User Manual

BARRIER FREE

PIAZZA™ COUNTERTOP SINK

VITREOUS CHINA

PIAZZA™ COUNTERTOP SINK

Made from vitreous china

Self-rimming with cutout template supplied

Large faucet deck and generous bowl

Front overflow

0478.403 Faucet holes on 4" (203mm) centers

0478.803 Faucet holes on 8" (102mm) centers (illustrated)

0478.001 center hole only

Nominal Dimensions:

23-1/2" x 18-3/8"

(597 x 467mm)

Bowl sizes:

 

 

 

 

18-1/2" (470mm) wide

FINISHED WALL

(203mm)

(70mm)

 

11-3/4" (299mm) front to back

 

 

 

OR SPLASHBACK

8"

2-3/4"

OPTIONAL

6-1/2" (165mm) deep

Compliance Certifications - Meets or Exceeds the Following Specifications:

ASME A112.19.2M for Vitreous China Fixtures

CAN/CSA B45 series

To Be Specified:

 

Color: White

Bone

Linen

Silver

Fawn Beige Black

Faucet*:

Faucet Finish:

Supplies:

1-1/4" Trap:

7"

(178mm)

18-3/8" (467mm)

SEALING

23-1/2"

 

COMPOUND

3/4"

COUNTERTOP

(597mm)

(19mm)

 

(BY OTHERS)

 

 

 

 

7-3/4"

*10-3/4"

 

(197mm)

 

 

(273mm)

 

 

*12-7/8"

 

 

(327mm)

 

SUPPLIES

 

 

AS REQ'D

 

8"

31"

 

(787mm)

 

(203mm)

 

SUGGESTED

 

 

 

 

1-1/4" O.D. WASTE

 

 

33-1/4"

 

 

1-1/4" O.D. TAILPIECE (845mm)

FINISHED FLOOR

 

 

51mm

(2)

845mm (33-1/4)

686mm

(27)

MIN.

610mm

(24)

203mm

 

 

 

DRAWING FOR

(8)

 

 

 

DIMENSIONAL

 

 

 

 

 

 

PURPOSES ONLY.

MIN.

 

 

 

IT IS NOT AN EXACT

REPRESENTATION.

152mm

(6)

MAX.

BARRIER FREE

CLEARANCE 229mm

(9)

MIN.

* See faucet section for additional models available

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES

AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES - CHECK LOCAL CODES.

Install lavatory 864mm (34") from finished floor. Lavatory installed 51mm (2") minimum from front edge of countertop provides 686mm (27") knee clearance.

NOTES:

* DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP ARE SUGGESTED.

FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE TEMPLATE SUPPLIED WITH SINK.

FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY.

SEALING COMPOUND SUPPLIED BY OTHERS.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.

 