American Standard 0475.020, 0475.920, 0476.037, 4801.862, 0476.028 User Manual

0 (0)
BARRIER FREE
FINI SHED
WALL
OR
441m m
(17- 3/8)
518mm (20-3/8)
175m m (6-7 /8)
71mm
(2-1 3/16)
203mm
(8)
OPTIONAL
C/L
FINI SHED
FLOO R
1-1/ 4 O.D .
TAIL PIECE
1-1/ 4 O.D .
WAST E
203m m
(8)
178m m
(7)
279m m
(11)
*
COUNTERTOP (BY OTHERS)
178m m
(7)
10mm
(3/8)
SEALING COMPOUND
SUPPLIES AS REQ'D.
324m m
(12- 3/4)
*
787mm (3 1)
854mm (3 3-5/8)
854mm (33-5/8)
51mm
(2)
610mm
(24)
152mm
(6)
MAX.
BARRIE R FREE
CLEARA NCE
686mm
(27)
MIN.
203mm
(8)
MIN.
229mm
(9)
MIN.
DRAWING FOR DIMENSIONAL
PURPOSES ONLY. IT IS NOT AN EXACT REPRESENTATION.
AQUALYN™ COUNTERTOP SINK
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES - CHECK LOCAL CODES.
Install lavatory 864mm (34") from finished floor. Lavatory installed 51mm (2") minimum from front edge of countertop provides 686mm (27") knee clearance area.
• Made from vitreous china
• Self-rimming with cutout template supplied
• Front overow
• Faucet ledge Shown with 4801.862 Amarilis/Heritage faucet with Triune cross handles (not included)
0475.020 Faucet holes on 8" (203mm) centers
(illustrated)
0475.920 Faucet holes on 8" (203mm) centers
• Less overow
0476.028 Faucet holes on 4" (102mm) centers ❏ 0476.037 Faucet holes on 4" (102mm) centers
• Extra right-hand hole
0475.035 Faucet holes on 4" (102mm) centers
• Extra left-hand hole
0476.928 Faucet holes on 4" (102mm) centers
• Less overow
0475.047 Center hole only
Nominal Dimensions:
518 x 441mm (20-3/8" x 17-3/8")
AQUALYN™
COUNTERTOP SINK
VITREOUS CHINA
SEE REVERSE FOR ADDITIONAL ROUGHING-IN DIMENSIONS
Bowl sizes:
406mm (16") wide 254mm (10") front to back 143mm (5-5/8") deep
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.2M for Vitreous China Fixtures
To Be Specied:
Color: White Bone Linen Silver Fawn Beige Black
Faucet*: Faucet Finish: ❏ Supplies: 1-1/4" Trap:
* See faucet section for additional models available
© 2008 AS America Inc.
NOTES:
DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TR AP ARE
*
SUGGESTED. FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE TEMPLATE SUPPLIED WITH SINK. FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. SEALING COMPOUND SUPPLIED BY OTHERS.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to c hange or cancellation. No responsibility is assumed for use of superseded or voided pages.