American Standard 2703.XXXW Series User Manual

Size:
87.21 Kb
Download

ELLISSE BUILT-IN™2703.XXXW

2705.XXXW

SERIES WHIRLPOOL

HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS

INSTALLATION INSTRUCTIONS

 

 

 

 

 

1524mm

 

 

 

 

 

 

229mm

(60)

 

 

WATER RETENTION

SEE FITTING

 

 

 

 

(9)

 

 

 

 

 

 

 

 

 

 

FLANGE (3) SIDES

SPECS FOR

 

 

 

 

 

 

19mm

 

FINISHED

 

 

 

 

DIMENSION

 

 

 

 

 

 

WALL LINE

 

 

 

 

(3/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

387mm

 

 

 

 

 

 

 

 

 

(15-1/4)

 

 

 

 

 

 

PUMP

 

 

 

 

 

 

 

 

 

813mm

 

 

 

 

 

 

 

 

 

(32)

 

 

 

229x305mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/L OF

 

(9x12) FLOOR

 

 

 

 

 

 

 

CUTOUT

 

 

 

 

 

SUPPLIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51mm

 

 

 

 

 

ON/OFF SWITCH

 

 

 

 

ALT. PUMP

 

 

 

PROVIDE ACCESS

 

 

 

(2)

 

 

 

 

 

 

 

C/L OF DRAIN

 

LOCATION

 

 

TO PUMP FOR SERVICING

 

 

 

OUTLET

 

 

 

 

 

ON ALL INSTALLATIONS

 

 

 

C/L OF

 

 

 

FINISHED WALL

 

 

 

SHOWER ARM

 

C/L OF

 

 

 

 

1651-1981mm

 

 

 

 

 

 

 

 

 

 

 

SAFE-T-HEATER

 

VALVES

 

 

 

 

(65-78)

 

 

REMOVABLE BLANK

 

 

 

 

 

 

OPTIONAL

 

102mm

 

 

C/L OF

 

WATER

 

 

 

 

 

305mm

(4)

 

 

 

SPOUT

 

RETENTION

38mm

(12) OPT.

 

 

 

 

 

 

FLANGE

(1-1/2)

TOP

 

 

 

 

 

LEVELING

 

OF

 

51mm

 

 

 

 

STRINGER

UNDERSIDE

DECK

 

 

 

 

 

 

95mm (2)

C/L OF

 

 

 

NOT FOR

OF DECK

 

(3-3/4)

OVERFLOW

 

 

 

SUPPORT

 

546mm

 

 

 

 

 

ROUGH

533mm

 

(21-1/2)

 

 

 

 

 

FLOOR

 

 

 

 

INTEGRAL

 

 

 

(21)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEET

 

 

 

 

 

 

 

 

ROUGH

1-1/2N.P.T.

 

 

 

 

 

 

 

 

FLOOR

 

38mm

 

 

83mm

 

 

 

 

THREADS

 

 

 

 

 

 

 

 

(1-1/2)

 

 

(3-1/4)

 

 

 

 

1-1/2O.D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.

To insure maximum performance and pleasure from this product, please follow the instructions and cautions.

List of Optional Components (not included):

Apron Kit*

Safe-T-Heater9075.120*

* see your American Standard Distributor

List of Required Components (not included):

Drain 1583.470*

• Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools

Supplies

Level

Nails

Tape Measure

Putty

Pipe Wrench

Caulking (waterproof)

Slip Joint Pliers

1 x 3 or 2 x 2

Screw Driver

 

Stringers

Standard

Drop Cloth

 

Woodworking Tools

15 or 20 amp GFCI

Personal Safety

 

Outlet

 

Equipment

Cement, Plaster,

Caulking Gun

 

Grout

GENERAL INSTALLATION INFORMATION

TAILPIECE

GENERAL SPECIFICATIONS FOR 2703/5 WHIRLPOOL

INSTALLED SIZE

 

 

 

 

 

 

 

 

60 x 32 x 21-1/2In. (1524 x 813 x 546mm)

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

141 Lbs. (63 Kg.)

WEIGHT w/WATER

 

 

 

 

 

 

 

 

643 Lbs. (292 Kg.)

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

60 Gal. (277 L)

WHIRLPOOL MIN. OPERATING VOL.

 

 

 

 

 

 

 

 

50 Gal. (189 L)

 

 

 

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

44-1/2X 20 In. (1130 mm X 508 mm)

BATHING WELL AT RIM

 

 

 

58 X 26-1/4In. (1473 mm X 667 mm)

WATER DEPTH TO OVERFLOW

 

 

 

 

 

 

14-1/2In. (368 mm)

 

 

 

 

 

 

FLOOR LOADING

 

 

 

 

 

48 Lbs./Sq.Ft. (231 Kgs./Sq.m)

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

 

20.8

CUBE (FT3)

 

 

 

 

35.3

 

 

 

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

 

 

 

 

 

 

1.6 HP, 9.7 AMPS, 120V.

 

 

 

 

 

SYSTEM II PUMP

 

 

 

 

 

 

2.1 HP, 15.6 AMPS, 120V.

 

 

 

 

 

 

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.

If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

FOR AFTER-SALESSERVICE CALL 1 (800)442-1902WEEKDAYS.

© American Standard Inc. 2003

752352-100 REV. H All product names listed herein are trademarks

of American Standard Inc. unless otherwise noted.

FRAMING AND INSTALLATION

BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION, AS SHOWN IN RECESS INSTALLATION DIAGRAM.

THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED. THE SUMP OF THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS REQUIRED. ONCE THE BATH IS IN PLACE, THE FEET SHOULD BE SHIMMED ACCORDINGLY, SO THATTHE RIM OF THE BATH CONTACTS THE STRINGER OR PIER BUT SUPPORTS NO WEIGHT. ANY FINISH MATERIAL, SUCH AS TILE OR WALL BOARD, MUST BESELF-SUPPORTINGIF IT CONTACTS THE RIM OF THE BATH.

LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR REAR MOTOR

MOUNT WHIRLPOOLS, PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.

TYPICAL RECESS INSTALLATION

1 X 3 LEVELING STRINGER

2 X 4 STRINGER SUPPORT

533mm

 

 

 

 

m

 

 

 

 

 

 

m

 

 

(21)

 

5

 

 

 

7

 

 

)

 

 

7

 

 

 

 

 

 

 

 

 

0

 

m

 

 

 

3

 

 

 

 

(

 

 

m

 

 

 

 

 

 

3

 

 

 

 

 

 

1

)

 

 

 

 

 

8

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

3

 

 

 

 

 

 

(

WIDTH

 

 

 

 

 

 

 

 

 

 

 

 

TUB

 

 

1527mm

 

 

 

1 X 3 X 8

WALL

(60-1/8)

 

 

 

LEVELING

 

 

 

 

STRINGER

BOARD

 

 

 

 

 

 

 

TILE

305mm

(12)

610mm

(24)

ADHESIVE

SEALANT

 

 

WHIRLPOOL ONLY:

 

 

 

BATH

UNLESS AN ACCESS OPENING OF AT LEAST

 

 

305mm X 610mm(12" X 24") IS PROVIDED,

 

LEVELING

WARRANTY SERVICE WILL NOT BE PERFORMED.

 

 

 

STRINGER

 

STUD FLANGE BRACKET INSTALLATION

BATH

FLANGE DRYWALL

SCREW

STUD

FLANGE

BRACKET

STUD

BATH

SECURE THE BATH TO THE STUDS AS SHOWN USING THE SCREWS AND BRACKETS PROVIDED -

SEE STUD FLANGE BRACKET INSTALLATION

STUD FLANGE BRACKET INSTALLATION

PROVIDED WITH THE BATH IS A PACKAGE OF (4) FOUR STUD FLANGE BRACKETS AND (8) EIGHT SCREWS. INSTALL BRACKETS AND SCREWS AS SHOWN IN WALL BRACKET INSTALLATION DETAIL. TWO BRACKETS SHOULD BE LOCATED EVENLY ACROSS THE BACK TILE FLANGE AND INSTALL ONE BRACKET ON EACH END OF THE BATH, TOWARDS THE FRONT END OF THE TILE FLANGE. THIS WILL ALLOW TILE FLANGE TO BE HELD SECURELY AGAINST STUDWALL OF RECESS INSTALLATION.

752352-100REV. H

(2)

SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE

ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-faultcircuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

1.6 HORSEPOWER MODELS:

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wiredfrom the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential.ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE

15 AMP MAXIMUM GFCI CIRCUIT.

2.1 HORSEPOWER MODELS:

The whirlpool should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be hard-wiredfrom the electrical power supply panel. The circuit must be a three (3) wire circuit fron the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential.ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE

15 AMP MAXIMUM GFCI CIRCUIT.

ELECTRICAL INSTALLATION

SEPARATE 15 AMP GFCI

or

SEPARATE 20 AMP GFCI

FOR 1.6HP MODELS

FOR 2.1HP MODELS

 

 

120 VAC

 

WHIRLPOOL MOUNTED

 

AIR or ELECTRONIC SWITCH

 

or

 

WALL TIMER-(1.6HPMODELS ONLY)

WHITE

BLACK

 

PUMP/MOTOR

 

GND.

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

752352-100REV. h

(3)

WIRE SELECTION GUIDE

 

 

 

 

 

 

 

 

 

 

Motor

Maximum distance from

The sizes shown on this

 

fusebox to motor

 

Hi-Performance

 

 

 

 

 

chart are recommendations

Rating

50'

100'

150'

 

200'

 

for copper conductors

 

 

 

 

 

 

 

 

only. Always follow

 

 

120V Power Line

 

 

 

 

local and national

1.6

12

12

10

 

8

electrical codes

 

 

2.1

 

 

 

 

 

 

12

10

8

 

8

 

 

 

 

 

 

 

 

DRAIN CONNECTION AND SYSTEM TEST

Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight.Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool is running.

POST INSTALLATION CLEAN-UP

Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface.

Post installation clean-upgenerally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.

Painter's naphtha can be used to remove excess adhesives and/or wet oil-basepaint.

HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.

Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing with a white automotive-typepolishing compound and waxing with a liquid wax.

752352-100REV. F

(4)

SPIC AND SPAN

®