American Standard 2664 User Manual

Size:
2.39 Mb
Download

INSTALLATION AND

OPERATION MANUAL

MODEL 2664

MODEL 2934

MODEL 3572

MODEL 2709

MODEL 2935

MODEL 3573

MODEL 2711

MODEL 2938

MODEL 3574

MODEL 2742

MODEL 2939

MODEL 3575

MODEL 2748

MODEL 2940

MODEL 3581

MODEL 2806

MODEL 2941

MODEL 3582

MODEL 2903

MODEL 2942

MODEL 3583

MODEL 2908

MODEL 2943

MODEL 3584

MODEL 2932

MODEL 2944

MODEL 6060

MODEL 2933

MODEL 2945

MODEL 7236

 

MODEL 3571

 

BATHTUBS, WHIRLPOOLS, AIR BATHS AND COMBINATION TUBS WITH OPTIONAL CHROMATHERAPY

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool and air bath versions are completely assembled with pump/blower and system piping. All you need to finish the installation are your selected fittings and electrical connections.

To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.

For questions or service issues, please call Technical Support 1-(800)-442-1902.

Please do not contact or return product to the store.

© AS America, Inc. 2010

All product names listed herein are trademarks of AS America, Inc. unless otherwise noted.

1

754532-100Rev. A

TABLE OF CONTENTS:

Cover................................................................................................

Page 1

Table of Contents..............................................................................

Page 2

Safety Instructions Notice.................................................................

Page 3

Installation, Framing and Post Installation

 

Clean-UpInstructions.......................................................................

Page 4

Roughing-inReferences for Recess Type Installations.....................

Page 5

Roughing-inReferences for Pier Type Installations...........................

Page 6

Under Deck Mounting Instructions....................................................

Page 6

Roughing-inReferences for All Model Series...................................

Pages 7 - 26

Electrical Installation Instructions.....................................................

Pages 27 - 32

Whirlpool Heater Operation................................................................

Page 32

Remote Air Blower Location Option..................................................

Pages 33 - 34

Operation: Single Speed Whirlpool...................................................

Page 35

Operation: EcoSilent Whirlpool with Lights.......................................

Page 36

Operation: Air Bath............................................................................

Page 37

Operation: Air Bath with Lights..........................................................

Pages 38 - 39

Operation: Combination Tub with Lights...........................................

Pages 40 - 41

Cleaning and Maintenence...............................................................

Page 42

Warranty...........................................................................................

Page 43

754532-100Rev. A

2

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS!

! WARNING: Risk of personal injury. Do not permit children to use this bathtub without adult supervision. Never drop or insert any object into any opening. Do not operate this unit without the guard over the suction fitting.

!WARNING: Risk of electric shock. Do not permit electrical appliances near any bathtub when bathtub contains water.

!WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse medical

history should consult a physician before using this product.

! WARNING: Risk of personal injury. Do not overfill bathtub before entering. Entering tub when filled more than 2/3 can cause overflow and slippery conditions. Exercise caution when entering and exiting.

! WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning.

! WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.

Use this unit only for its intended use as described in this manual.

Do not use any attachments not recommended by American Standard.

The unit must be connected only to a supply circuit that is properly protected by a ground-faultcircuit-interrupter(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this air bath. Disconnect the air bath and have the problem corrected by a licensed electrician before using.

SAVE THESE INSTRUCTIONS

3

754532-100Rev. A

Installation and Framing Instructions

Each bath arrives ready for installation, completely equipped with the pump/blower electronics and plumbing necessary for operation. However, a drain/overflow kit is required for each bath and it is not included.

The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required. Ensure roughing-indimensions are proper, plumb, and square.

!Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift the bath by the plumbing at any time; handle by the shell only.

!All bath units are factory tested for proper operation and watertight connections prior to shipping. Prior to installation, the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling.

!The sumps of these baths are supported by feet and no additional sump support is required. Once the bath is in place, the feet should be shimmed and secured accordingly so that the rim of the bath contacts the stringer or pier but supports no weight.

!Provisions must be made in all installations for an access opening for servicing the bath pump/blower. Unless an access opening of at least 12" x 24" (305mm x 610mm) is provided, warranty service will not be performed. It is strongly recommended that an additional opening be provided for access to drain components.

!Each bath has a nominal length (L), width (W), and Height (H) along with a rim height. Unless otherwise noted in the following rough-inreferences, assume that the nominal tolerances are as much as+/-1/4inch (6mm). Therefore, it is strongly recommended that the installer build the surrounding structure after receiving the actual bath. Structural measurements should be verified against the actual bath received to ensure proper fit.

POST INSTALLATION CLEAN-UP

Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.

Do not use wire brushes or any other metal implement on bath surface.

Post installation clean-upgenerally can be completed using warm water and liquid dishwashing detergent.

Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.

Painter's naphtha can be used to remove excess adhesives and/or wet oil-basepaint.

754532-100Rev. A

4

ROUGH-INREFERENCES FOR RECESS TYPE INSTALLATIONS

C

E

NOTE:

FRONT EDGE

OF BATH MUST

BE SUPPORTED

BY STUD WALL OR AMERICAN STANDARD APRON KIT

D

12"

 

W

(305 mm)

LEVELING STRINGERS

mm)

ACCESS PANEL MUST BE LOCATED

ON THE SAME SIDE AS THE MOTOR.

ALLOW OPEN FRAMING ON

PUMP/MOTOR END FOR SERVICE.

ACCESS PANELS NOT

REQUIRED FOR BATH TUBS

UNLESS AN ACCESS OPENING OF AT LEAST 12" x 24" (305 x 610mm) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

TYPICAL TILE FLANGE INSTALLATION

WOOD

STUD

STUDS

 

WATERPROOF DRYWALL

OR CEMENT BOARD

 

TILE

 

ROOFING NAIL

 

SEALANT

 

TUB

 

1" x 3" (25 x 76mm) WOOD

 

STRINGER FULL LENGTH

STEEL

STEEL

 

STUDS

STUD

 

WATERPROOF DRYWALL

WASHER

 

OR CEMENT BOARD

 

 

TILE

 

 

SEALANT

 

 

 

4" (102mm)

 

 

DRYWALL

 

TUB

SCREW

 

 

1" x 3" (25 x 76mm) WOOD

STRINGER FULL LENGTH

SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION.

TYPICAL TILE BEAD INSTALLATION

 

TILE

 

WALLBOARD

 

SEALANT

TILE

 

BEAD

BATH

STRIP

 

 

ADHESIVE

 

LEVELING STRINGER

 

1" x 4" (25mm x 102mm) not for support

NOTE: Tile bead kit not included and must be purchased separately.

5

754532-100Rev. A

ROUGH-INREFERENCES FOR PIER TYPE INSTALLATIONS

AS DESIRED

F

CUTOUT

G

CUTOUT

C

AS DESIRED

MOUNTING

SURFACE

WATERPROOF SEALANT

BATH

12" (305 mm)

24" (610 mm)

ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR.

ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE.

ACCESS PANELS NOT REQUIRED FOR BATH TUBS

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

UNDER DECK MOUNTING INSTRUCTIONS

Please note that care must be taken to protect the surface of the tub during all aspects of the installation. Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.

1.Install the tub per the installation instructions provided with the unit.

2.Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.

3.Cut bath deck to your specifications.

4.Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.

5.Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.

6.Replace the bath deck and secure it into place.

7.Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.

8.Remove excess sealant per the manufacturer's instructions.

Finished bath deck surface material must be self-supportingand secured per local codes

Waterproof Sealant

Bathtub

Bath deck support material

Tub support structure per installation instructions provided with the tub

754532-100Rev. A

6

SPECIFICATIONS:

 

L

 

 

 

W

 

 

J

 

 

 

 

 

H

 

 

C

 

A

 

 

 

 

 

 

 

 

 

 

 

 

SIDE VIEW

 

 

END VIEW

 

 

B

DRAIN / OVERFLOW

 

 

 

 

 

 

 

 

 

 

GENERAL SPECIFICATIONS FOR WHIRLPOOLS AND BATH TUBS

 

 

 

Description

Dimensions

Drain /

Height to

Cut Out

Rough-In

Tub Edge to

Weight with

Product

Gallon to

Whirlpool

 

L-W-H

Overflow

Underside

Pier

Recess

Centerline

Water / Floor

Weight

Overflow

Operating

 

 

 

of Deck: C

G x F

E x D

Overflow: J

Loading

 

 

Volume

2664

L 83-1/2"(2121mm)

A 16"

C 18-1/4"

Template

N/A

6-3/8"

781 lb. (351 kg)/

94 lb.

80 gal.

58 gal.

Scala

W 63-3/4"(1619mm)

(406mm)

(464mm)

Provided

 

(162mm)

37 lb./sq.ft.

(43 kg.)

(303 l.)

(220 l.)

Corner

H 19-3/4"(502mm)

B 13-1/4"

 

 

 

 

(182 kg/sq.m)

 

 

 

 

 

(337mm)

 

 

 

 

 

 

 

 

2709

L 69-1/4"(1759mm)

A 15"

C 18-1/4"

Template

As

3"

640 lb. (291 kg)/

107 lb.

64 gal.

53 gal.

Ellisse Oval

W 38-1/2"(978mm)

(381mm)

(464mm)

Provided

Desired

(76mm)

35 lb./sq.ft.

(49 kg.)

(242 l.)

(200 l.)

6'

H 19-3/4"(502mm)

B 9-7/8"

 

 

 

 

(171 kg/sq.m)

 

 

 

 

 

(251mm)

 

 

 

 

 

 

 

 

2711

L 72" (1829mm)

A 16-5/8"

C 19-1/2"

70-1/2"

72-3/16"

4"

950 lb. (431 kg)/

133 lb.

95 gal.

74 gal.

Ellisse

W 48" (1219mm)

(422mm)

(495mm)

(1791mm)

(1833mm)

(102mm)

40 lb./sq.ft.

(60 kg.)

(359 l.)

(280 l.)

6' x 48"

H 21-1/2"(546mm)

B 12"

 

x 46-1/2"

x 46-1/2"

 

(196 kg/sq.m)

 

 

 

 

 

(305mm)

 

(1181mm)

(1181mm)

 

 

 

 

 

2742

L 71-1/2"(1816mm)

A 16-1/4"

C 20"

70"

71-11/16"

4"

690 lb. (313 kg)/

115 lb.

69 gal.

60 gal.

Town Square

W 41-3/4"(1060mm)

(413mm)

(508mm)

(1778mm)

(1821mm)

(102mm)

33 lb./sq.ft.

(52 kg.)

(261 l.)

(227 l.)

6' x 42"

H 22" (559mm)

B 13-1/4"

 

x 40-1/4"

x 40-1/4"

 

(161 kg/sq.m)

 

 

 

 

 

(337mm)

 

(1022mm)

(1022mm)

 

 

 

 

 

2748

L 59-1/2"(1511mm)

A 14-1/2"

C 21"

58"

59-11/16"

5-1/4"

611 lb. (277 kg)/

110 lb.

60 gal.

55 gal.

Town Square

W 41-5/8"(1057mm)

(368mm)

(533mm)

(1473mm)

(1517mm)

(133mm)

40 lb./sq.ft.

(50 kg.)

(227 l.)

(208 l.)

5' x 42"

H 23" (584mm)

B 14-1/2"

 

x 40-1/8"

x 40-1/8"

 

(196 kg/sq.m)

 

 

 

 

 

(368mm)

 

(1019mm)

(1019mm)

 

 

 

 

 

2806

L 72" (1829mm)

A 17"

C 19-1/2"

Template

As

5-1/2"

744 lb. (338 kg)/

135 lb.

73 gal.

44 gal.

Heritage Oval

W 35-3/4"(908mm)

(432mm)

(495mm)

Provided

Desired

(140mm)

41 lb./sq.ft.

(61 kg.)

(276 l.)

(166 l.)

6' x 36"

H 21-1/2"(546mm)

B 11"

 

 

 

 

(200 kg/sq.m)

 

 

 

 

 

(279mm)

 

 

 

 

 

 

 

 

2903

L 60" (1524mm)

A 17"

C 19-1/4"

Template

As

3"

640 lb. (291 kg)/

107 lb.

64 gal.

53 gal.

Savona Oval

W 42-1/4"(1073mm)

(432mm)

(489mm)

Provided

Desired

(76mm)

35 lb./sq.ft.

(49 kg.)

(242 l.)

(200 l.)

5' x 42"

H 21-1/4"(540mm)

B 9-1/2"

 

 

 

 

(171 kg/sq.m)

 

 

 

 

 

(241mm)

 

 

 

 

 

 

 

 

2908

L 66" (1676mm)

A 17"

C 18-1/4"

Template

As

6"

659 lb. (299 kg)/

95 lb.

68 gal.

55 gal.

Reminiscence

W 36" (914mm)

(432mm)

(464mm)

Provided

Desired

(152mm)

40 lb./sq.ft.

(43 kg.)

(257 l.)

(208 l.)

Oval

H 24-1/4"(616mm)

B 13"

 

 

 

 

(191 kg/sq.m)

 

 

 

 

 

(330mm)

 

 

 

 

 

 

 

 

6060

L 76-3/4"(1949mm)

A 17"

C 19-1/2"

Template

N/A

5-5/8"

824 lb. (374 kg)/

108 lb.

86 gal.

71 gal.

Cadenza

W 65-3/8"(1661mm)

(432mm)

(495mm)

Provided

 

(130mm)

25 lb./sq.ft.

(49 kg.)

(352 l.)

(269 l.)

Corner

H 21-1/2"(546mm)

B 13-3/4"

 

751680-100

 

 

(117 kg/sq.m)

 

 

 

 

 

(349mm)

 

 

 

 

 

 

 

 

7236

L 72" (1829mm)

A 17-3/4"

C 19-1/4"

70-1/2"

72-3/16"

4"

751 lb. (338 kg)/

101 lb.

78 gal.

69 gal.

Virtuoso

W 36" (914mm)

(451mm)

(489mm)

(1791mm)

(1833mm)

(102mm)

42 lb./sq.ft.

(45 kg.)

(296 l.)

(262 l.)

6' x 36"

H 21-1/4"(540mm)

B 11"

 

x 34-1/2"

x 34-1/2"

 

(204 kg/sq.m)

 

 

 

 

 

(279mm)

 

(876mm)

(876mm)

 

 

 

 

 

TABLE 1

7

754532-100Rev. A

ROUGH-INREFERENCES

MODEL SERIES 2664

 

64-1/4"

3/4"

(1619mm)

-

 

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

AT

IO

 

 

 

 

 

 

 

 

 

 

 

 

OC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

TTING

L

 

 

(1632mm) 1/2"-63(1600mm)

 

60"

 

505mm

 

 

)

 

 

 

 

279mm)

 

1/2"-42(1080mm)

 

524mm)

(1

 

 

 

FI

 

 

 

 

 

 

-1/4"

 

 

 

 

 

(724mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1

RECOMMENDED

x

 

 

 

 

 

 

 

 

 

59

 

 

 

(64

 

 

 

 

 

 

 

 

 

 

 

 

 

1"

-1/2"

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

-1/2"

x

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

10" x 10" (254mm x 254mm) DRAIN OUTLET CUTOUT

21-3/4"

 

 

(552mm)

8-1/2"

 

 

(216mm)

 

3/4"(19mm)

 

CUTOUT DIMENSION

16"

 

 

C

 

(406mm)

LOF DRAIN OUTLET

 

41"

(1041mm)

-3/8"

)

53

356mm

(1

 

 

1" (25mm) INTEGRAL TILE FLANGE (2) SIDES

PROVIDE ACCESS TO PUMP SERVING ON

ALL INSTALLATIONS

1/2" 30(775mm)-

MODEL SERIES 2709

69-1/4"(1759mm)

9-7/16"

(240mm) OUTLINE OF CUTOUT

12" (305mm) x 9" (229mm) CUTOUT IN FLOOR FOR DRAIN

38-1/2"(978mm)

19-1/4"(489mm)

3"

(76mm)

CL OF DRAIN

OUTLET

PROVIDE ACCESS TO PUMP SERVING ON

ALL INSTALLATIONS

754532-100Rev. A

8

 

ROUGH-INREFERENCES

 

 

MODEL SERIES 2711

 

 

 

72"

 

 

 

(1829mm)

 

 

36-1/2"

OUTLINE OF CUTOUT

4"

 

70-1/2"X46-1/2"

 

(102mm)

 

(927mm)

(1791 X 1181mm)

 

 

12"

 

 

 

(305mm)

 

 

 

 

 

 

C/L OF

 

 

 

DRAIN

 

 

9" x 14"

 

48"

 

(229 x 356mm)

 

 

FLOOR

 

(1219mm)

 

 

 

CUTOUT

 

 

 

 

 

 

 

PROVIDE ACCESS

 

 

 

TO PUMP

 

 

 

SERVING ON

 

 

 

ALL INSTALLATIONS

RECOMMENDED

GRAB BAR

OPTIONAL

 

FITTING AREA

 

DECK FITTING

 

FITTING

 

 

 

AREA

 

LOCATION

 

 

 

 

 

2-1/2"X 11"

 

 

 

MODEL SERIES 2908

13"

 

 

66"

 

 

(1676mm)

(330mm)

 

 

 

18"

 

9" X 12"

(457mm)

 

 

(229 x 305mm)

 

 

 

 

FLOOR

36"

 

CUTOUT

(914mm)

 

 

 

INTEGRAL

 

 

2-1/2"REF.

FITTING

 

 

(64mm)

DECK

 

 

 

6"

OVERFLOW

OUTLINE OF

(152mm)

C/L OF

 

CUTOUT

 

 

DRAIN

OUTLET

PROVIDE ACCESS TO PUMP SERVING ON

ALL INSTALLATIONS

9

754532-100Rev. A

ROUGH-INREFERENCES

MODEL SERIES 2806

72"

11" (1829mm) (279mm)

18"

(457mm) 9" x 13"

(229 x 330mm)

35-3/4" FLOOR CUTOUT (908mm)

INTEGRAL

 

 

 

FITTING

 

 

 

DECK

 

 

 

 

 

 

PROVIDE ACCESS

 

 

 

TO PUMP

 

 

 

SERVING ON

5-1/2"

C/L OF DRAIN

OUTLINE

ALL INSTALLATIONS

(140mm)

OVERFLOW

OF CUTOUT

 

 

 

 

MODEL SERIES 2903

 

60"

 

 

(1524mm)

 

 

9-1/2"

OUTLINE OF

 

(241mm)

 

CUTOUT - USE

 

 

 

 

TEMPLATE

4-1/4"

12" (305mm) X 9"(229mm)

 

(1073mm)

 

CUTOUT IN FLOOR FOR DRAIN

 

 

 

21-1/8"

 

PROVIDE ACCESS

(537mm)

 

 

 

TO PUMP

 

 

SERVING ON

3"

 

ALL INSTALLATIONS

 

 

(76mm)

 

 

C

OF DRAIN

 

L

OUTLET

 

754532-100Rev. A

10