1 |
CONTENTS |
|
2 |
CONNECT BATTERY CARTRIDGE |
|
|
|
||||
www.apc.com |
|
|
|
RJ-11 |
RJ-11 |
|
|
|
|
|
|
|
|
|
|
|
|
USB |
RJ-45 |
|
Back-UPS® HT1000 |
|
|
Back-UPS HT |
RJ-45 |
RJ-45 |
|
and HT 1500 |
|
|
|
|
|
|
|
|
|
|
|
||
User’s Manual |
|
|
Pedestal |
Coaxial Cable |
|
|
|
|
® |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Software CD-ROM |
User’s Manual |
|
|
|
|
|
|
|
3 OPERATING ENVIRONMENT |
32 - 104oF (0 - 40oC) |
4 CONNECT EQUIPMENT AND POWER |
|
5 |
CHECK BUILDING |
6a CONNECT PHONE, |
|
7 |
CONNECT COAXIAL CABLES |
||||
HT 1000 Rear Panel |
|
HT 1500 Rear Panel |
|
WIRING FAULT |
|
MODEM, FAX |
|
|
(PHONE, INTERNET, and/or |
||
|
Note: All outlets on the HT1500 provide |
|
|
INDICATOR |
|
|
|
|
CATV or DSS) |
||
|
battery backup and surge protection. |
|
If |
the rear panel |
Building Wiring |
Outlet |
|
|
|
From Cable Provider |
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
Wall |
Phone |
|
|
|
|
|
|
Fault (red) indicator is lit, a potential |
|
|
|
(Phone, Internet, |
||||
SURGEONLY |
|
|
shock hazard exists due to one of the |
|
Jack |
|
|
and/or CATV, or |
|||
|
|
following conditions: |
|
|
|
|
CABLE IN |
DSS) |
|||
|
|
|
|
|
|
|
|
||||
BATTERYBACKUP |
|
|
• |
Open or high resistance ground |
|
|
|
|
|
||
|
DVR or |
|
• |
Hot or neutral polarity reversed |
10/100 Base-T/VOIP |
|
|
|
To Cable Modem, |
||
|
CD / DVD Drive |
|
• |
Overloaded neutral circuit |
|
Modem/Phone/Fax |
|
|
|
VCR, DSS or TV |
|
|
|
|
Computer |
|
|
|
|||||
|
|
|
Improper building wiring should be |
Modem Port |
|
|
CABLE OUT |
Cable Box |
|||
|
|
|
corrected by a qualified electrician. |
OR |
|
|
|
|
|||
|
|
|
Do not use the Back-UPS until the |
|
|
|
|
||||
|
|
|
condition that caused the fault is |
6b CONNECT 10/100 Base-T |
8 |
CONNECT INTERFACE CABLE |
|||||
|
|
|
corrected. |
|
|
||||||
Circuit Breaker |
Media PC |
Circuit Breaker |
Note: Improper building wiring will |
or VOIP |
|
|
|
For connection of APC’s optional |
|||
Push to Reset |
|
Push to Reset |
not |
prevent the |
Back-UPS |
from |
|
|
|
|
external 24-volt battery pack |
|
|
|
operating, but it |
will limit |
its |
|
|
|
|
||
|
|
|
|
Wall |
|
|
(BR24BP) to the Back-UPS HT 1500. |
||||
|
|
|
protection capability. |
|
|
|
|
||||
|
|
|
|
|
Outlet |
|
|
|
|
|
|
|
Network Jack |
To Computer USB |
|
|
|
|
|
|
|
|
|
|
||
Input: 120V~ |
Plasma/ |
Input: 120V~ |
|
|
|
Port |
|
|
12A, 60Hz |
12A, 60Hz |
|
|
USB |
RJ-45 |
Data Port |
BR24BP Battery Pack |
|
|
High Definition TV |
Building Wiring |
|
|
|
|
||
|
|
|
|
|
|
|
||
|
|
Fault Indicator |
Building |
Computer |
10/100 Base-T/VOIP |
|
|
|
|
|
|
Modem/Phone/Fax |
|
|
|
||
|
|
|
Wiring Fault |
Network Port |
|
|
|
|
|
To AC Utility |
|
|
|
Computer |
|
|
|
|
|
|
|
|
|
|
|
|
|
Power |
|
|
|
|
|
|
|
9 SWITCH ON THE BACK-UPS
Note: Allow the Back-UPS to charge for a full eight
(8) hours prior to use.
Press the front panel Power ON/OFF switch and observe that the following events occur after pressing and releasing the switch:
•The green On Line indicator flashes.
•The yellow On Battery indicator lights while a Self-Test is being performed.
•When Self-Test has successfully completed, only the green On Line indicator will be lit.
•If the internal battery cartridge is not connected (see Step 2 above), the green On Line indicator and red Replace Battery indicators will light. The Back-UPS will also emit a chirping sound.
10INSTALL SOFTWARE ON COMPUTER
Follow the on-screen instructions.
If Autoplay is enabled on your computer, the software on the CD-ROM will automatically start the installation program.
If Autoplay is not enabled on the computer, proceed as follows:
1.On the computer desktop of the display, doubleclick on My Computer.
2.Double-click on the CD-ROM drive icon and follow the on-screen instructions.
11 FINAL ORIENTATION |
STATUS INDICATORS AND ALARMS |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
There are four status indicators (lights) on the front |
On Battery (yellow) - is lit whenever the battery of |
Overload (red) - is lit whenever power demand has |
Replace Battery (red) - is lit whenever the |
|||||||||
|
|
|
panel of the Back-UPS (On Line, On Battery, |
the Back-UPS is powering equipment connected to |
exceeded the capacity of the Back-UPS. |
|
|
battery is near the end of its useful life, or if the |
|||||||
|
|
|
Overload, and Replace Battery). |
the Battery Backup Outlets. |
|
|
|
|
|
|
|
|
battery is not connected (see above). A battery |
||
|
|
|
|
|
|
|
|
|
Continuous Tone - this alarm |
|
|
that is near the end of its useful life has |
|||
|
|
|
|
Four Beeps Every 30 Seconds - this alarm is |
is sounded |
insufficient run-time and should be replaced. |
|||||||||
|
|
|
|
whenever |
the |
Battery |
Backup |
outlets |
are |
|
|||||
|
|
|
|
sounded whenever the Back-UPS is running |
|
||||||||||
|
|
|
|
overloaded. |
|
|
|
|
|
Chirps for 1 Minute Every 5 Hours - |
|||||
|
|
|
On Line |
On |
Battery. |
Consider |
saving |
work-in- |
|
|
|
|
|
||
|
|
|
progress. |
|
|
|
|
|
|
|
|
|
this alarm is sounded whenever the |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
On Battery |
|
|
|
|
|
Circuit Breaker - the circuit breaker button |
battery has failed the automatic |
|||||
|
|
|
Continuous Beeping - this alarm is sounded |
diagnostic test. |
|||||||||||
|
|
|
Overload |
located on the rear panel of the Back-UPS will |
|
||||||||||
|
|
|
whenever a low battery condition is reached. |
stick out if an overload condition forces the |
|
||||||||||
|
|
|
Replace Battery |
Battery run-time is very low. Promptly save |
Back-UPS |
to |
disconnect itself |
from utility |
|
||||||
|
|
|
any work in progress and exit all open appli- |
power. If the button sticks out, disconnect non- |
|
||||||||||
|
|
||||||||||||||
|
cations. Shutdown the operating system, |
essential equipment. Reset the circuit breaker |
|
||||||||||||
|
|
|
|
computer and the Back-UPS. |
|
by pushing the button inward. |
|
|
|
||||||
|
|
|
On Line (green) - is lit whenever utility power is |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
powering the Battery Backup outlets. |
|
|
|
|
|
|
|
|
|
|
|
|