American Dryer Corp ID-170 User Manual

Size:
464.07 Kb
Download

SECTION VIII

DATA LABEL INFORMATION

A. DATA LABEL

When contacting American Dryer Corporation, certain information is required to insure proper service/parts information fromADC. This information is on the data label that is affixed to the left side panel area behind the top control (access) door. When contactingADC please have themodel numberas well as theserial number readily available.

47

THE DATA LABEL

1.MODEL NUMBER

The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam).

2.SERIAL NUMBER

The serial number allows ADC to gather information on your particular dryer.

3.MANUFACTURING CODE NUMBER

The manufacturing code number is a number issued by ADC, which describesALL possible options on your particular model.

4.TYPE OF HEAT

This describes the type of heat for your particular dryer: gas (either natural gas or liquid propane [L.P.] gas) or steam.

5.HEAT INPUT (for GAS DRYERS)

This describes the heat input in British Thermal Units per Hour (BTUH).

6.ORIFICE SIZE (for GAS DRYERS) Gives the number drill size used.

7.ELECTRIC SERVICE

This describes the electric service for your particular model.

8.GAS MANIFOLD PRESSURE (for GAS DRYERS)

This describes the manifold pressure taken at the gas valve tap.

9.APPLICABLE APPROVAL SEAL(S)

I.E., Canadian Standards Association International.

48

SECTION IX

PROCEDURE FOR FUNCTIONAL CHECK

OF REPLACEMENT COMPONENTS

1.For Models With Hot Surface Ignition (HSI) Module (CE Version)

a.Upon completing installation of the replacement HSI module, reestablish power to the dryer.

b.The HSI module’s “red” indicator light will

light for up to approximately 5-seconds(self check routine). If the HSI module’s “red” indicator light stays on or flashes continuously, then the HSI module is wired incorrectly or has failed.

c. Start the drying cycle.

d. The HSI will turn on, and after approximately 4-seconds,the ignitor will shut off and the gas valvewill be energized. Ignition (flame)should now be established.

e.With the burner flame on, remove the flame sensor wire from the S2 terminal of the HSI module. The burner flame must shut off immediately.

f.Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

g.The HSI will turn on, and after a few seconds later, the gas valve will be energized and the HSI will shut off. Ignition (flame)should be evident for approximately7-secondsand then shut off.

h.The HSI module will attempt to light burner only “once.” If flame is not reestablished the HSI module will lockout and the “red” indicator light will flash continuously.

i.Functional check of the HSI module is complete.

1)Replace the flame sensor wire from the S2 terminal to the HSI module.

49

SECTION X

BURNER AND BASKET (TUMBLER)/LINT CHAMBER MANUAL RESET HI-LIMITINSTRUCTIONS

I M P O RTA N T

MANUAL RESET HI-LIMITINSTRUCTIONS

FOR PHASE 7 MODELS (GAS MODELS ONLY)

This dryer was manufactured with a burner manual reset hi-limitand basket (tumbler)/lint chamberhi-limitthermostat, which is monitored by the Phase 6 computer. If either manual reset thermostat is open prior to start of the drying cycle, the dryer will start momentarily and then shutdown, the Phase 6 computer will display an error code with an audio indication. If the basket (tumbler)/lint chamberhi-limitthermostat is open, the display will read “dRUM SAFETY FAIL.” If the burnerhi-limitthermostat is open, the display will read “bURNER SAFETY FAIL.”

If either manual reset hi-limitthermostat opens during a drying cycle, the display will show the applicable error code described above along with an audio indication. If the drum temperature is above 100º F (38º C), the dryer will continue to run with no heat for 3 minutes or until the drum temperature has flattened below 100º F (38º C). The clear/stop button on the Phase 6 keyboard (touch pad)must be pressed to clear the error condition. The open manual resethi-limitthermostatmust be reset “manually” prior to the start of the next cycle.

This hi-temperaturecondition may be caused due to a restricted exhaust, poor airflow, or improper burner operation.

The location of the burner hi-limitis on the right side of the burner box and the basket (tumbler)hi-limitis located in the lint chamber area.

WARNING: Discontinue power to dryer before attempting to resethi-limit.

IMPORTANT

This dryer is equipped with a burner hi-limitand tumbler/lint chamberhi-limitthermostat which must be reset manually.

WARNING: Discontinue power to dryer before attempting to resethi-limit.

ADC P/N: 114093