Phase 7 / Gas Only

WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building or area of all occupants.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

AVERTISSEMENT: Assurez-vousde bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

Ne pas tenter d’allumer d’appareils.

Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment.

Évacuez la pièce, le bâtiment ou la zone.

Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.

L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.

For replacement parts, contact the reseller from which the dryer was purchased or

American Dryer Corporation

88 Currant Road

Fall River, MA 02720-4781

Telephone: (508) 678-9000 /Fax: (508)678-9447E-mail:techsupport@amdry.com www.amdry.com

103100GS/tcosta

ADC Part No. 113049

Retain This Manual In A Safe Place For Future Reference

American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, andtrouble-freeoperation.

ONLY qualified technicians should service this equipment.

OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.

The following “FOR YOUR SAFETY” cautionmust be posted near the dryer in a prominent location.

FOR YOUR SAFETY

POUR VOTRE SÉCURITÉ

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.

We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models. The illustrations included in this manual may not depict your particular dryerexactly.

Important

For your convenience, log the following information:

AD-670Phase 7

DATE OF PURCHASE _______________________________ MODEL NO. __________________________________________

RESELLER’S NAME _______________________________________________________________________________________

Serial Number(s) ________________________________________________________________________________________

________________________________________________________________________________________

________________________________________________________________________________________

Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order toADC at (508)678-9447or telephone your order directly to theADC Parts Department at (508)678-9000.Please specify the dryermodel number andserial number in addition to thedescription andpart number, so that your order is processed accurately and promptly.

“IMPORTANT NOTE TO PURCHASER”

Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructionsmust be posted in a prominent location near the dryer.

IMPORTANT

YOUMUST DISCONTINUEAND LOCKOUTTHE ELECTRIC SUPPLYANDTHE GAS SUPPLY BEFORE ANY COVERS, GUARDS, OR DOORS ARE REMOVED OR OPENED TO ALLOWACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.

“Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper operation.”

«Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de câblage peuvent entraîner un fonctionnement inadéquat et dangereux.»

CAUTION

DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.

WARNING

CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYERS.

CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.

FOR YOUR SAFETY

DO NOT DRY MOP HEADS IN THE DRYER.

DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.

WARNING

UNDER NO CIRCUMSTANCES should the dryer door switches, lint drawer switch, heat safety circuit, or tilt switches ever be disabled.

WARNING

The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT.

WARNING

DRYER MUST NEVER BE OPERATED WITHOUT THE LINT DRAWERS IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.

IMPORTANT

PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.

Dryers must not be installed or stored in an area where itwill be exposed to water or weather.

The wiring diagram for the dryer is located in the left front electrical control cabinet.

 

Table of Contents

 

SECTION I

 

IMPORTANT INFORMATION ............................................................................

3

A. Receiving and Handling ...........................................................................................................

3

B.

Safety Precautions ..................................................................................................................

4

SECTION II

 

SPECIFICATIONS AND DIMENSIONS .............................................................

6

A. Specifications .........................................................................................................................

6

B. Dimensions ............................................................................................................................

7

SECTION III

 

INSTALLATION PROCEDURES .........................................................................

8

A. Location Requirements ...........................................................................................................

8

B. Fresh Air Supply Requirements ...............................................................................................

9

C. Exhaust Requirements...........................................................................................................

10

D. Electrical Requirements.........................................................................................................

13

E.

Gas Requirements ................................................................................................................

15

F.

Compressed Air Requirements ..............................................................................................

18

G.

Preoperational Tests .............................................................................................................

19

H. Preparation For Operation/Start-Up ......................................................................................

21

I.

Shut Down Instructions .........................................................................................................

22

SECTION IV

 

ROUTINE MAINTENANCE ...............................................................................

23

A. Cleaning ..............................................................................................................................

23

B. Adjustments.........................................................................................................................

25

C. Lubrication ..........................................................................................................................

25

SECTION V

 

SERVICE/PARTS INFORMATION....................................................................

26

A. Service ................................................................................................................................

26

B. Parts ...................................................................................................................................

26

SECTION VI

 

WARRANTY INFORMATION ............................................................................

27

A.

Returning Warranty Cards .....................................................................................................

27

B.

Warranty .............................................................................................................................

27

C.

Returning Warranty Parts ......................................................................................................

27

SECTION VII

 

DATA LABEL INFORMATION ..........................................................................

29

A. Data Label...........................................................................................................................

29

SECTION VIII

 

GAS TRAIN AND BURNER DESCRIPTION AND OPERATION .................

31

A. Pilot Gas Supply Line ...........................................................................................................

31

B. Main Gas Supply Line ..........................................................................................................

33

C. Lo-FireGas Supply Line Loop .............................................................................................

34

SECTION IX

 

COMPONENT SYSTEM DESCRIPTIONS ......................................................

35

A. Basket (Tumbler) Drive System .............................................................................................

35

B.

Basket (Tumbler) .................................................................................................................

36

C.

Blower System.....................................................................................................................

36

D.

Air Jet System .....................................................................................................................

36

E.

Safety Devices .....................................................................................................................

36

SECTION X

 

PHASE 7 OPL SYSTEM DIAGNOSTICS..........................................................

38

A. Diagnostic (L.E.D. Display) Fault Messages ...........................................................................

38

B. I/O Board Input and Output L.E.D. Indicators........................................................................

40

SECTION XI

 

TROUBLESHOOTING ........................................................................................

45

SECTION XII

 

OPTIONAL SPRINKLER SYSTEM COMPONENTS .....................................

52

SECTION I

IMPORTANT INFORMATION

A. RECEIVING AND HANDLING

The dryer is shipped in three (3) pieces with protective stretch wrap, protective cardboard corners, and top covers as a means of preventing damage in transit. Upon delivery, the individual pieces and/or packaging, and wooden skids should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves.

Dryers damaged in shipment:

1.ALL dryersshould be inspected upon receipt and before they are signed for.

2.If there is suspected damage or actual damage, the trucker’s receipt should be so noted.

3.If the dryer is damaged beyond repair, it should be refused. Those dryers, which were not damaged in a damaged shipment,should be accepted, but the number received and the number refusedmust be noted on the receipt.

4.If you determine that the dryer was damaged after the trucker has left your location, you should call the delivering carrier’s freight terminal immediately and file a claim. The freight company considers this concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult when more than a day or two passes after the freight was delivered. It is your responsibility to file freight claims. Dryer/parts damaged in transit cannot be claimed under warranty.

5.Freight claims are the responsibility of the consignee, and ALL claimsmust be filed at the receiving end.ADC assumes no responsibility for freight claims or damages.

6.If you need assistance in handling the situation, please contact the ADC Traffic Manager at (508)678-9000.

IMPORTANT: The dryermust be transported and handled in an upright position atALL times.

3

B. SAFETY PRECAUTIONS

WARNING: For your safety, the information in this manualmust be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life.

WARNING: The dryer must never be operated with any of the safety guards, service panels, or service doors removed or open. PERSONAL INJURY OR FIRE COULD RESULT.

1.DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

2.Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location.

3.WHAT TO DO IF YOU SMELL GAS...

a.DO NOT try to light any appliance.

b.DO NOT touch any electrical switch.

c.DO NOT use any phone in your building.

d.Clear the room, building, or area of ALL occupants.

e.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

f.If you cannot reach your gas supplier, call the fire department.

4.Installation and service must be performed by a qualified installer, service agency, or gas supplier.

5.Dryer(s) must be exhausted to the outdoors.

6.Although ADC produces a very versatile dryer, there are some articles that, due to fabric composition or cleaning method,should not be dried in it.

WARNING: Dry only water washed fabrics.DO NOT dry articles spotted or washed in dry cleaning solvents, a combustible detergent, or “all purpose” cleaner.

EXPLOSION COULD RESULT.

WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint, or wax.

EXPLOSION COULD RESULT.

WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard.

4

WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubberlike materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.

7.A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.

WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard.

8.For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the National Electrical Code ANSI/NFPA NO.70-LATESTEDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSAC22.1-1990or LATEST EDITION.

NOTE: Failure to do so willVOID THE WARRANTY.

9.UNDER NO CIRCUMSTANCES should the dryer door switches, lint drawer switch, heat safety circuit, or tilt switches ever be disabled.

WARNING: PERSONAL INJURY OR FIRE COULD RESULT.

10.This dryer is not to be used in the presence of dry cleaning solvents or fumes.

11.Remove articles from the dryer as soon as the drying cycle has been completed.

WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can create a fire hazard.

12.READ AND FOLLOWALL CAUTION AND DIRECTION LABELSATTACHED TO THE DRYER.

13.For safety, proper operation, and optimum performance, the dryer must not be operated with a load less thansixty-sixpercent (66%) 442 lbs (200 kg) of its rated capacity.

WARNING: YOU MUST DISCONTINUE AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY BEFORE ANY COVERS, GUARDS, OR DOORS ARE REMOVED OR OPENED TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS.

5

SECTION II

SPECIFICATIONS AND DIMENSIONS

A. SPECIFICATIONS

Maximum Capacity (Dry Weight)

670 lb

303.9 kg

Basket Diameter

78-1/4"

198.8 cm

Basket Depth

92"

233.7 cm

Basket Volume

256 cu ft

7.25 cu m

Blower Motor

2 x 5 hp

2 x 3.73 kW

Basket Motor

25 hp

18.7 kW

Door Sill Height, Level

52"

132.1 cm

Compressed Air Volume (1-way / 2-way tilt)

15/19 cfh

0.42/0.54 cmh

Compressed Air Connection

1/2" F.N.P.T.

S.A.F.E. Water Connection*

1" F.N.P.T.

 

Voltage Available

208-480v /3Ø / 3,4w / 50/60 Hz

Gas

Heat Input

2,200,000 Btu/hr

554,400 kcal/hr

Approx. Shipping Weight

9,200 lb

4,173 kg

 

 

Airflow

13,000 cfm

368 cmm

 

Inlet Pipe Connection**

2" F.N.P.T.

061103

*Water supply must be 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) for S.A.F.E. system to operate properly .

**Size of piping to dryer varies with installation conditions. Contact factory for assistance.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6