Alto-Shaam 6.10ESG, 10.20ESG, 10.10ESG User Manual

Size:
2.22 Mb
Download

 

 

 

 

 

 

Co mb in ati o n

 

 

 

 

 

Ov e n / St eame

r

 

 

 

 

 

 

ES GAS

 

 

 

 

 

 

 

SERIES

 

 

 

 

 

 

 

6•10ESG

 

 

 

 

 

 

 

10•10ESG

 

 

 

 

 

 

 

7•14ESG

 

 

 

 

 

 

 

10•20ESG

 

 

 

 

 

 

 

12•18ESG

 

 

 

 

 

 

 

20•20ESG

 

 

 

 

 

 

INST ALLATI ON

 

W16 4 N9 221

Wate r Stre e t • P.O. Box

450

• Men omon ee Fal ls, Wi sco nsin 53052-0450US A

 

PHONE:

262.251.3800 • 800.558.8744

USA/CANADA

 

FAX:

262.251.7067 • 800.329.8744 U.S.A.ONLY

 

 

 

 

WEBSITE: www.alto-shaam.com

 

 

P RINT ED IN U .S.A.

 

 

 

 

 

#MN -28676

• 08/08

 

General Infor mation

 

 

 

Deliver y / Unpacki ng . . . . . . . . . . . . . . . . .

.1.

 

Safety Procedur es and Preca utions . . . . . . . .

.2.

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifi cat ions

 

 

 

Opti ons . . . . . . . . . . . . . . . . . . . . . . . . . .

.3.

 

6•10esG . . . . . . . . . . . . . . . . . . . . . . . . . .

.4.

 

10•10esG . . . . . . . . . . . . . . . . . . . . . . . . .

.5.

 

7•14esG . . . . . . . . . . . . . . . . . . . . . . . . . .

.6.

 

10•20esG . . . . . . . . . . . . . . . . . . . . . . . . .

.7.

 

12•18esG . . . . . . . . . . . . . . . . . . . . . . . . .

.8.

 

20•20esG . . . . . . . . . . . . . . . . . . . . . . . . .

.9.

 

 

 

 

 

 

 

 

 

 

 

Installatio n Requi re men ts

 

 

 

Installa tion Code s & Sta nda rds . . . . . . . . . . .

10.

 

Vent ila tion Genera l Requi remen ts . . . . . . . . .

11.

 

Positioni ng on Sit e . . . . . . . . . . . . . . . . . . .

11.

 

Minimum Cle aran ce Requir ement s . . . . . . . .

11.

 

Positioni ng Requi rement s . . . . . . . . . . . . . .

12.

 

Vent ila tion Speci fic Requi rements . . . . . . . . .

13.

 

Electr ical Require men ts . . . . . . . . . . . . . . . .

14.

 

Drip Tray Inst alla tion . . . . . . . . . . . . . . . . .

15.

 

Mobile Equ ipment Restra int . . . . . . . . . . . . .

15.

 

Gas Supply Spe cificati ons . . . . . . . . . . . . . .

16.

 

Gas Pressure s . . . . . . . . . . . . . . . . . . . . . .

16.

 

Gas Conne cti on . . . . . . . . . . . . . . . . . . . . .

17.

 

Gas Leak Testin g . . . . . . . . . . . . . . . . . . . .

19.

 

Gas Exhaust . . . . . . . . . . . . . . . . . . . . . . .

19.

 

Water Qua lity Requi rements . . . . . . . . . . . . .

20.

 

Water Conne cti on . . . . . . . . . . . . . . . . . . .

21.

 

Water Filtra tion Sys tem . . . . . . . . . . . . . . . .

22.

 

Water Draina ge . . . . . . . . . . . . . . . . . . . . .

23.

 

 

 

 

 

 

 

 

 

Installatio n Checkl ist . . . . . . . . . . . . . . . . .

24.

 

 

 

 

 

 

 

 

 

Err or Code s

 

 

 

Contr ol Reset . . . . . . . . . . . . . . . . . . . . . .

25.

 

Error Code s . . . . . . . . . . . . . . . . . . . . . . .

25.

 

Emerg ency Operati on . . . . . . . . . . . . . . . . .

28.

 

 

 

 

 

 

 

Equipm ent Limit ed Warran ty . . . . . . . . . . .

29.

 

 

 

 

 

 

 

Transporta tion Damage and Claims . . . . . .

30.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

®

DELI VERY

This Alto-Shaam applian ce has been

thorou ghly tested and ins pect ed to insur e only the

highest quality

unit is prov ided. Upo n receipt,

check for any possible shippin g dama ge and repo rt

it at once to the delivering carrier. See

Trans porta tion Damage and Claims sec tion

located in this manual .

 

This appliance, complete with unattac hed

items and acc essories, may have been delivered in

one or more packages . Chec k to ensure that all

stan dard ite ms and options

have been received

with each mod el as ordered.

 

Sav e all the inf orm ation

and instruct ions

pack ed with the appliance.

Complete and return

the warranty card to the factory as soo n as

possib le to assure prompt serv ice in the event of a

warranty parts

and lab or claim.

This manual must be read and understo od by

all peop le using

or installin g the equipment

model . Contact

the Alto-Shaam service

depa rtment if you have any quest ions con cer ning

insta llation, operation, or mainte nance.

NOTE: All claims for war ranty must include the ful l mod el number and seria l number of the unit.

UNPACK I NG

1.Carefull y remov e the applia nce from the carto n or crate.

NOTE : Do not disca rd the

®

carton and other

 

packa ging material

 

until you have

 

inspected the unit

 

for hidde n damage

 

and tested it for

 

prope r operation.

 

2.Read all instru ctions in this manual carefu lly before initiating the installation of this appliance.

DO NOT DISCARD THIS MANUAL.

This manual is conside red to be part of the applia nce and is to be provided to the owner or manager of the busin ess or to the person responsib le for training ope rators. Addition al

manual s are available from the Alto-Shaam service department.

3.Rem ove all protecti ve plastic film, packaging materi als, and access orie s from the appli anc e before connecting electric al pow er. Store any acces sori es in a convenient place for futu re use.

CAU TIO N

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

THE INFOR MAT IO N CO NTAINED

IN THIS

LES IN FORM ATION S CO NTENU ES DA NS CE

MAN UAL IS IMPOR TANT

FO R TH E PR OP ER

MANU EL SO NT IMPO RTANTES

POUR

INS TALLATI ON OF TH IS

OVEN .

PLE ASE

L'INS TALLATI ON L'UTI LISATI ON ET

READ CARE FULLY AND RETAIN FO R

L'ENTR ETIEND DE CE FOU R.

S'IL VOUS

FUTUR E REFER ENC E.

 

 

 

PLAIT LISEZ -LETRES ATTENTIVEMEN T ET

 

 

 

 

CON SERVEZ -LE.

 

IM PR OPE R CONN EC TIO N OF THIS

AP PLIAN CE

 

WILL NU LLIFY ALL WARR ANTIES .

 

LA NON -APPLICATIO N DE CES

CONSIGN ES

 

 

 

 

ANNU LE TOUTES GAR ANTIES .

 

 

 

GAS

C OMB ITH ERM

INS TA LLA TI O N M AN UAL#MN-28676

 

PG. 1

SAFETY PROC EDURES

AND PRECA UTI ONS

Knowl edg e of prop er proc edu res is essen tial to the safe opera tion of elec trically and/or gas energize d equi pment. In accorda nce with gen erally accepte d produ ct safety labeling guideline s for poten tial hazards, the following sign al wor ds and symbo ls may be used throughout this manual.

DAN GER

Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.

WA RNING

Used to indicate the presence of a hazard that CAN cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.

C AU TI ON

Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.

C AU TI ON

Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.

NOTE: Used to noti fy per sonnel of installation, oper ation, or

mai ntena nce inform ation that is import ant but not hazard rela ted .

1.This appliance is intended to coo k, hold or proce ss food s for the purpose of human consumption . No other use for this applianc e is authori zed or recom mended.

2.This appliance is intended for use in comme rcial establishments where all operators are fami liar with the purpose, limitations, and ass ociated hazards of this appliance. Operati ng

instruct ion s and warnings must be read and understoo d by all operators and users.

3.Any troubleshoot ing guides , component views, and parts lists included in this manual are for general reference only and are inte nded for use by qualif ied technica l person nel.

4.This manual should be con sid ere d a permanent part of this appliance. This manual and all supplied instr uct ions, diagra ms, sche matics , parts list s, notices, and labels must remain with the appliance if the item is sold or moved to another location.

N O TE

For equipment delivered for use in any location regulated by the following directive:

DO NOT DISPOSE OF ELECTRICAL

OR ELECTRONIC EQUIPMENT WITH

OTHER MUNICIPAL WASTE.

CAU TION

WHEN WELDING ANY STAINLESS

STEEL COMPONENTS ON THIS

APPLIANCE,THE ELECTRONIC

CONTROL BOARDS MUST BE

ISOLATED FROM THE APPLIANCE.

GAS CO MBI TH ERM I NSTA LLATI ON M A N UAL#MN-28676

PG. 2

®

COMBITHERM

COMMON SPECIFICATIONS

COMBIG UAR D™ TRIPL E-GUARD WATE R

 

 

 

FILTRATION SYSTE M

 

 

 

 

(INCLUDES1 CARTRIDGE)

 

 

FI-23014

COMBIG UARD

REPL ACEMENT FIL TER

 

FI26356

FRY BASKET, 12"

X 20" (325mm x 530m m)

 

BS-26730

GRILL ING GRATE,

 

 

 

 

12" X 20" (325mm x 530m m)

 

 

SH267 31

OVE N CLEANER

 

 

CE-24750

 

SPECIALL Y FORMULA TED FOR COM BIT HERM OVENS

 

 

 

TWELVE (12) CONTAINE RS/CASE, 1

QUAR T (C. 1 LITER) EACH

QUICK DISCONNEC T KI T

 

 

CR-33543

SCA LE FREE

 

 

 

CE-27889

 

(CITRUS

BASE D, NON-CORROSIVE DELIMI NG PRODUC T)

 

 

CASE =

FOUR 4-LBBOT TLE S; 4 -LBBOTTL E MAKES10

GALLONS

SERVICE START-UPCHEC K

SPECIFY AS REQUIRED

 

AVAILABL E THROUGH AN ALTO -SHAAMFASTE AM CEN TER

 

 

■ Comp uter S oftw are Op tion s

 

 

5005 676

 

Not available on S-ControlModels.

 

 

 

 

REFER TO HACC P SPECI FICATIO N SHE ET

#9015

 

 

FOR APPL ICABLE PART NUMB ERS

■ HACCP Documentati on

■ HACCP Documentati on w ith Kitchen Mana gement

Wire less HACCP Doc umentatio n wi th Kitchen Management

Six (6) Chi cken Roa sti ng R ack

(PAN NOT INCLUD ED)

SH-23000

Ten (10) Chic ken Roas ting Rack SH-22634

Fry Ba sket BS-26730

IEEE 80 2.11b S TANDARDS

Gril ling Grate SH-26731

GAS C OMB ITH ERM INS TA LLA TI O N M AN UAL#MN-28676

PG. 3

6•10E S G SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMBITHERM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(60mm)3/8"-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Drain

 

 

 

 

(1018mm)

 

 

 

 

1/16"-3(76mm)

 

 

 

 

(92mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(871mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11-1/2"(292mm)

 

 

 

 

 

 

42-1/16"(1068mm)

 

 

 

 

 

 

 

 

 

 

 

37" (939mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-1/2"(140mm)

15-5/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-5/8"

 

 

 

 

 

 

(396mm)

 

 

 

 

40-1/8"

 

 

 

 

 

 

 

 

 

 

 

 

34-5/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Treated Water Intake (Bottom)

 

(Side Back)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19-3/8"

(492mm)

Untreated Water Intake (Bottom)

(1478mm)

1/4"-6(159mm)

27-3/4"(704mm) (863mm)34"

5"(125mm)

 

 

" 5/8 - 10 (270mm)

Vent

 

 

 

 

 

 

 

Steam

 

 

 

 

 

 

 

(Top)

 

 

 

Water Drain

 

 

 

 

 

 

 

(Bottom)

 

Gas Connection

Electrical

 

 

 

 

 

 

(Bottom)

Connection (Bottom)

 

 

 

 

 

 

 

 

3/16"

25"

7-1/2"

5-1/2"

21-11/16"

 

 

 

-

(635mm)

(191mm)

(140mm)

(550mm)

 

 

2" (50mm)

58

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIME NSIONS : H x W x D

 

 

 

 

47-5/16"(1201mm)

EXTERIOR:

34" x 42-1/16" x 37" (8 63mm x 1068mm x 939mm )

 

 

 

EXTERIOR WITH RETRACTABLE DOOR:

 

 

 

 

 

INTERIOR:

34" x 46-1/16" x 37" (8 63mm x 1170m m x 939mm)

 

 

 

17-3/4" x 17-3/8"x26-13/16"

(450mm x 4 40mm x 680mm)

LEF T: 6" (152mm)

PLUS SERVICE ACCESS : 18" (457mm) RECOM MENDED

CONNECTED ENERGY LOAD :

45,000 Btu /hr

CLEARA NCE REQUIREMENTS

 

 

GAS RE QUI REME NT S

 

 

 

 

 

20" (508mm)

FRO M HEA T PR OD UC ING

EQUI PM ENT

 

 

 

HOOK -UP:

3/4" NPT

RIGHT

: 4" (102mm)

 

TOP : 20" (5 08mm) FOR AIR MOVEMENT

MINIMUM CONNECTED PRESSURE:

5.5" W.C.

(Natural Ga s)

BAC K

: 4" (102mm)

BOTTO M: 5- 1/ 8"

(130 mm )

FOR LEGS

MAXIMUM CONNECTED PRESSURE :

9" W.C. (Propane)

COUNT ER -TOPINS TALLATIONS MUST MAINT AIN 4" (102mm)

14" W.C.

 

GAS TYPE MUST BE SPECIFIED ON ORDER.

 

 

MINIM UM CLEA RANCE FROM THE COUNT ER SURFACE.

 

 

 

 

 

 

 

 

WAT ER Q UALI TY M IN IM UM S TA ND AR DS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WATER

 

R EQUI REMENTS

 

 

 

 

 

 

 

 

 

 

 

ONE (1) TREATED WATER INLET:

3/4" NPT*

 

 

WARRANTY. It is the responsibility of the purchaser to ensure

ONE (1) UNTREATED WATER INLET:

3/4" NPT*

2.8 to 6.2 bar

that incoming water supply is compliant with the specifications

LINE PRESSURE:

 

30 to 90 psi

listed through adequate treatment measures. Installation of the

 

 

WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP

CombiGuard™ Water Filtration System is recommended, but this

* Can manifold off of one 3/4" line.

 

 

system may not address all water quality issues present.

 

 

 

 

 

 

 

 

Contaminant

 

Inlet Water Requirements (untreated water)

INS TAL LAT ION REQUIREMENTS

 

 

Free Chlorine

 

Less than 0.1 ppm (mg/L)

 

 

 

 

 

 

 

 

 

Hardness

 

Less than 3 gpg (52 ppm)

 

Oven must b e in stalled l evel. Hood ins tallati on. Wa ter supp ly

 

Chloride

 

Less than 30 ppm (mg/L)

 

shut-off v alv e a nd back-flow pr event er. Alt ern ate burner orifi ce

pH

 

7.0 to 8.5

 

 

 

is requi red f or installation s ites at elevati ons of 3,000 fee t (9 14m)

Alkalinity

 

Less than 50 ppm (mg/L)

 

Silica

 

Less than 12 ppm (mg/L)

 

abo ve sea

lev el.

 

 

 

 

 

Total Dissolved

 

Less than 60 ppm

 

 

 

 

 

 

 

 

 

Solids (tds)

 

 

ELECTR

IC AL

 

 

 

 

 

 

 

6•1 0E S G

 

6• 10E S G/s k

VOLTAGE

PHASE

CYCLE/HZ

AWG

 

 

AMPS

kW

 

AMPS

kW

110 - 120

1

50/60

 

2 Wire plus ground, AWG 12

 

5.7

0.68

 

9.5

1.14

 

OTH ER VOLTAGE S AVAILA BLE : Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WEIGHT

 

 

 

CA PA CIT Y

 

 

 

 

 

 

 

 

NET

 

377 lb EST .

(171 kg) EST .

 

FULL-SIZEPANS: 20" x 12" x2-1/2"

 

Six (6)

 

Four (4)

 

 

 

GN 1/1: 530 x 325 x 65mm

 

Six (6)

 

Four (4)

 

 

 

 

 

 

 

 

 

SHI P

 

442 lb EST .

(200 kg) EST .

HALF-SIZESHEET PANS:*

18" x 13" x 1"

 

Six (6)

 

Five (5)

 

 

 

 

 

 

ON WIRE SHELVES ONLY

 

 

 

 

 

 

 

CRATE

 

40" X 45"X 40"EST .

 

 

 

 

 

 

 

 

 

 

 

 

72 lb (33 k g) MAX IM UM

 

 

 

DIME NSI ONS: (1016 x 1143 x 1016mm )

 

 

 

 

 

 

 

 

VOL UM E MAXIM UM : 45

QUA RTS

(57 LITE RS)

 

 

 

 

 

 

GAS

CO MBI TH ERM

I NSTA LLATI ON

M A N UAL #MN-28676

 

 

 

 

 

 

PG. 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

®

 

 

 

 

 

 

 

10•10E S G SPECIFICATIONS

 

COMBITHERM

 

 

 

 

 

 

 

 

 

1/16"-3(76mm)

 

 

 

 

(60mm)

 

11-1/2"(292mm)

 

 

 

42-1/16"(1068mm)

 

 

 

37" (939mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40-1/8"

 

 

 

 

34-5/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-3/8"

 

5-1/2"(140mm)

 

15-5/8"

 

(1018mm)

 

 

 

 

(871mm)

 

3-5/8"

 

 

(396mm)

 

 

 

 

 

 

 

 

 

19-3/8"(492mm)

(92mm)

 

 

Water Drain

 

 

1/4"-6(159mm)3/8"-37(949mm)5/8"-43(1108mm)

(125mm)5"

 

 

 

 

 

 

 

 

 

(1478mm)

 

 

 

 

 

" 5/8 - 10 (270mm)

Treated Water Intake (Bottom)

(Side Back)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent

 

 

 

 

 

 

 

Water Drain

 

 

 

Untreated Water

 

(Top)

 

 

 

 

 

 

 

 

 

 

Intake (Bottom)

 

 

 

 

 

 

 

 

 

(Bottom)

Gas Connection

Electrical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Bottom)

Connection (Bottom)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/16"

25"

 

7-1/2"

 

5-1/2"

 

21-11/16"

 

 

 

 

 

 

 

 

-

(635mm)

(191mm)

 

(140mm)

 

(550mm)

 

 

2" (50mm)

 

 

 

 

58

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIM ENS IONS : H x W x D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERIOR:

 

 

 

 

 

 

 

 

 

47-5/16"(1201mm)

 

 

 

 

43-5/8"x42-1/16"x 37"

(1108mm x 1068mm x 939mm )

 

 

 

 

 

 

 

 

 

EXTERIOR WITH RETRACTABLE DOOR:

 

 

 

 

 

 

 

 

 

 

 

 

 

43-5/8" x46-1/16" x 37"

(1108mm x 1170mm x 939mm)

 

 

 

 

 

 

 

 

 

INTERIOR:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27-3/8" x17-3/8" x26-13 /16"

(695mm x 440 mm x 68 0mm)

LEF T: 6" ( 152mm)

PLUS SERVICE ACCE SS : 18" (457mm) RECOMMENDED

 

CONNECTED ENERGY LOAD :

68,00 0 Btu/ hr

CLEARANCE

REQUIREM

EN TS

 

 

 

GAS RE QU IR EM ENT S

 

 

 

 

20" ( 508mm)

F ROM HEAT

PRO DUCI NG

EQU IPM ENT

 

 

 

HOOK-UP : 3/4 " NPT

RIG HT : 4" ( 102mm)

 

TOP : 20" (508mm)

FOR AIR MOVEMENT

MINIMUM CONNECTED PRESS URE:

5.5" W.C. (Natural Gas)

BA CK

: 4" ( 102mm)

BO TTOM : 5-1/ 8"

(1 30mm ) FOR LEGS

MAXIMUM CONNECTED PRESSURE:

9" W.C.

(Propane)

COUNTER -TOPINS TALLATI ONS MUST MAINT AIN4" (102mm)

14" W.C.

 

GAS TYPE MUST BE SPECIFIED ON ORDER .

 

MINIMUM CLE ARANCE FROM THE COUNT ER SURFAC E.

WATER QU AL IT Y M INI MU M S TAND ARDS

 

 

 

 

 

 

 

 

 

 

TWO (2) COLD WATER INLETS - DRINKING QUALITY

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WATER

RE QUIREMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

ONE (1) TREATED WATER INLET:

3/4" NPT*

 

 

WARRANTY. It is the responsibility of the purchaser to ensure

ONE (1) UNTREATED WATER INLET:

3/4" NPT*

 

2.8 to 6.2 bar

that incoming water supply is compliant with the specifications

LINE PRESSURE:

 

 

30 to 90 psi

 

listed through adequate treatment measures. Installation of the

 

WATER DRAIN: 1-1/2"

CONNECTION WITH AIR GAP

CombiGuard™ Water Filtration System is recommended, but this

* Can manifold off of one 3/4" line.

 

 

 

 

 

system may not address all water quality issues present.

 

 

 

 

 

 

 

 

 

 

Contaminant

Inlet Water Requirements (untreated water)

INS TALL ATION REQ UIREMENTS

 

 

Free Chlorine

Less than 0.1 ppm (mg/L)

 

Oven must be installed

leve l. H ood ins tall ati on. Wat er suppl y

 

Hardness

Less than 3 gpg (52 ppm)

 

 

Chloride

Less than 30 ppm (mg/L)

 

shut-off va lve and back-flow preventer. Alternat

e bur ner orifi ce

 

pH

7.0 to 8.5

 

 

 

is requir ed for install ation s ites at elevati ons of 3,000 fe et (9 14m)

 

Alkalinity

Less than 50 ppm (mg/L)

 

 

Silica

Less than 12 ppm (mg/L)

 

abo ve se a level.

 

 

 

 

 

 

 

Total Dissolved

Less than 60 ppm

 

 

 

 

 

 

 

 

 

 

 

 

Solids (tds)

 

 

ELECT RICA L

 

 

 

 

 

 

 

 

 

10• 10 ES G

 

10• 10 E S G/sk

VOLTAGE

 

PHASE

 

 

CYCLE/HZ

AWG

 

 

AMPS

kW

 

AMPS

kW

110 - 120

 

1

 

 

 

50/60

 

2 Wire plus ground, AWG 12

5.7

.68

 

9.5

1.14

 

OT HER VO LTAG ES AVAILA BLE : Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz

 

 

 

 

 

 

WEIGHT

 

 

 

 

 

CAPA CIT Y

 

 

 

 

 

 

 

NET

490 lb EST .

(222 kg )

EST.

 

FULL-SIZEPANS: 20" x 12" x2-1/2"

 

Ten (10)

 

 

Eight (8)

 

 

GN 1/1: 530 x 325 x 65mm

 

Ten (10)

 

 

Eight (8)

 

 

 

 

 

 

 

 

 

 

 

 

SHI P

530 lb EST .

(240 kg )

EST.

HALF-SIZESHEET PANS:*

18" x 13" x 1"

 

Ten (10)

 

 

Nine (9)

 

ON WIRE SHELVES ONLY

 

 

 

 

 

 

 

CRATE

 

50" X 45" X 40" EST .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 lb ( 54 k g) MAXI MU M

 

 

 

DIMENSIO NS:

(1270 x 1143 x 1016 mm)

 

 

 

 

 

 

 

 

VO LUME MAXI MUM: 75 QUARTS (95 LITE RS )

 

 

 

 

 

 

 

 

 

*ADD IT IONAL WIRE SH ELVES REQ UIRE D FO R MAX IMUM

CAPAC ITY

 

 

 

 

 

 

 

 

 

 

GAS

C OMB ITH ERM INS TA LLA TI O N

M AN UAL

#MN-28676

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PG. 5

7•14E S G SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMBITHERM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27-9/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44-7/16"(1128mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41-3/4"(1060mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(700mm)

 

 

 

 

 

49-13/16"(1265mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-3/8"(110mm)

 

 

 

 

 

 

 

 

Water Drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-13/16"

 

22-11/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47-7/8"(1215mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-9/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(325mm)

 

 

(575mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(89mm)

(Side Back)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26-3/4" (678mm) 19-3/8" (491mm) 17-3/8" (441mm) 6” (151mm)

Electrical

 

 

1/16"-30(763mm)(954mm)5/8”-37

(1066mm)42"

13/16"-4(121mm)

 

Treated Water Intake (Bottom)

Connection (Bottom)

(1865mm)

 

 

 

Steam Vent (Top)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Drain

 

Gas Connection

 

 

 

 

 

 

(Bottom)

Untreated Water Intake (Bottom)

 

 

 

 

 

 

 

(Bottom)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/16"

31-3/4"

7-9/16"

 

9/16"

25-5/8"

 

 

 

(650mm)

2" (50mm)

 

(805mm)

(192mm)

 

(13mm)

 

-

 

 

8-1/2"(216mm)

 

73

33-1/8"

7-3/16"

 

 

 

 

4-5/8"(116mm)

 

 

 

 

 

 

 

 

 

 

 

 

(840mm)

(181mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIME NSI ONS:

H x W x D

 

 

 

 

 

55-1/16"(1398mm)

 

EXTERIOR:

 

 

(10 66mm x 1265mm x 1128mm)

 

 

42" x 49-13 /16"x44-7/16"

 

 

 

 

 

 

 

 

 

 

 

 

EXTERIOR WITH RETRACTABLE DOOR:

 

 

 

 

 

 

42" x 53-13 /16"x44-7/16"

 

(10 66mm x 1367mm x 1128mm)

 

 

 

INTERIOR:

 

 

 

 

 

 

 

 

23-5/8" x25-1/4" x 33-7 /8"

(600mm x 640mm x 86 0mm)

LEF T: 6" (152mm)

PLUS SERVICE ACCESS

: 18" (457mm)RECOMMENDE D

 

CONNECTED ENERGY LOAD:

91,000 Btu/ hr

CLEA RA NCE REQUIREM

ENTS

 

 

 

 

 

GAS RE QU IR EM EN TS

 

 

 

 

20" (508mm)

FROM HEAT PR ODU CI NG

EQUIPM

EN T

 

 

 

 

HOOK-UP :

3/4" NPT

RI GHT : 4" (102mm)

 

TOP : 20" (508mm)

FOR AIR MOVEMENT

 

MINIMUM CONNECTED PRESSURE:

5.5" W.C.

(Natural Ga s)

BA CK : 4" (102mm)

BO TTOM : 5- 1/8 " (130 mm ) FOR LEGS

 

MAXIMUM CONNECTED PRESSURE :

9" W.C. (Propane)

COUNTER -TOPINS TALL ATIONS MUST MAIN TAIN 4" (102mm)

 

14" W.C.

 

 

GAS TYPE MUST BE SPECIFIED ON ORDER.

 

MINIMUM CLEARANC E FROM THE COUN TER SURFAC E.

 

 

 

 

 

 

 

 

 

WAT ER Q UALI TY M IN IM UM S TA ND AR DS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

 

 

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WATER RE

QUIREMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ONE (1) TREATED WATER INLET:

3/4" NPT*

 

 

 

 

WARRANTY. It is the responsibility of the purchaser to ensure

ONE (1) UNTREATED WATER INLET:

3/4" NPT*

 

2.8 to 6.2 bar

 

that incoming water supply is compliant with the specifications

LINE PRESSURE:

 

 

30 to 90 psi

 

 

listed through adequate treatment measures. Installation of the

WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP

 

CombiGuard™ Water Filtration System is recommended, but this

* Can manifold off of one 3/4" line.

 

 

 

 

 

 

 

system may not address all water quality issues present.

 

 

 

 

 

 

 

 

 

 

 

Contaminant

 

Inlet Water Requirements (untreated water)

IN STALL ATION REQUIREMENTS

 

 

 

 

 

Free Chlorine

 

Less than 0.1 ppm (mg/L)

 

 

 

 

 

 

 

 

 

 

 

 

Hardness

 

Less than 3 gpg (52 ppm)

 

Oven must be installe d le vel. Hoo d i nst allat ion . Water s upply

 

 

 

 

Chloride

 

Less than 30 ppm (mg/L)

 

shut-off valve a nd back-flow p reven ter. Al ternate burne

r orific e

 

pH

 

7.0 to 8.5

 

 

 

 

is req uired for install ation si tes at el evation s o f 3,000 f

eet (914m )

Alkalinity

 

Less than 50 ppm (mg/L)

 

Silica

 

Less than 12 ppm (mg/L)

 

abo ve se a level.

 

 

 

 

 

 

 

 

 

Total Dissolved

 

Less than 60 ppm

 

 

 

 

 

 

 

 

 

 

 

 

Solids (tds)

 

 

ELEC TR IC AL

 

 

 

 

 

 

 

 

 

 

 

7•14 E S G

 

7• 14 E S G/s k

VOLTAGE

 

PHASE

 

CYCLE/HZ

 

AWG

 

 

AMPS

kW

 

AMPS

kW

110 - 120

 

1

 

50/60

 

2 Wire plus ground, AWG 12

 

5.7

0.68

 

9.5

1.14

OTHE R VO LTAG ES AVAILA BLE : Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WEI GHT

 

 

 

 

 

CAP ACI TY

 

 

 

 

 

 

 

 

 

NET

NOT YET AVAILAB LE

 

 

 

FULL-SIZEPANS:

20" x 12" x 2-1/2"

 

Fourteen (14)

 

Twelve (12)

 

 

 

 

 

GN 1/1:

530 x 325 x 65mm

 

Fourteen (14)

 

Twelve (12)

 

 

 

 

 

 

 

 

 

 

 

SHI P

NOT YET AVAILAB LE

 

 

 

 

 

GN 2/1:

650 x 530 x 65mm

 

Seven (7)

 

 

Five (5)

 

 

FULL-SIZESHEET PANS:*

 

18" x 26" x 1"

 

Seven (7)

 

 

Six (6)

CRATE

48" X 56"X 50"EST .

 

 

 

 

 

 

 

 

 

ON WIRE SHELVES ONLY

 

 

 

 

 

 

 

 

DIMENSIO NS:

(1219 x 1422 x 1473m

m)

 

 

 

 

 

 

168 l b (76 k g) MAXI MU M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL UM E MAXI MUM : 105

QU ARTS (133 LITE RS)

 

 

 

 

 

 

 

*AD DIT IONAL WIR E SH ELVES RE QUIR ED FOR MAXIM UM CAPAC ITY

 

 

 

 

 

 

 

 

 

 

GAS

CO MBI TH ERM I NSTA LLATI

ON

M A N UAL #MN-28676

 

 

 

 

 

 

PG. 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

®

 

 

 

 

10•20E S G SPECIFICATIONS

 

 

COMBITHERM

 

 

 

 

 

 

 

 

 

 

(151mm)

4-3/8"(110mm)

20-5/16"

 

 

 

45-3/16"

 

 

 

 

 

 

42-9/16"

 

 

 

 

 

 

 

 

 

 

 

(1148mm)

 

 

 

6"

3-9/16"

 

(515mm)

49-13/16"(1265mm)

 

 

(1080mm)

 

 

 

 

Water Drain

 

 

 

 

 

 

 

 

 

 

 

 

12-13/16"22-11/16"

 

 

 

 

(89mm)

 

(Side Back)

47-7/8"(1215mm)

 

 

 

 

(678mm)

3/8"-19(491mm)3/8"-17(441mm)

 

 

 

(325mm) (575mm)

 

3/4"-26

Electrical Connection (Bottom)

 

(1875mm)13/16"

 

(226mm)15/16"-8(1111mm)13/16"-43(1337mm)11/16"-52

(157mm)1/4"-6

 

 

 

 

 

Steam Vent

 

 

 

 

 

 

 

 

(Top)

 

 

 

 

 

 

 

 

 

 

Untreated Water

 

 

 

 

 

 

 

 

 

 

Intake (Bottom)

 

 

 

 

 

 

 

 

Gas Connection

Treated Water

 

 

 

 

 

Water Drain

 

 

Intake (Bottom)

 

 

 

 

 

 

 

 

(Bottom)

 

 

 

 

 

(Bottom)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-5/8"(116mm)

 

-

 

 

 

 

 

 

 

 

 

73

 

 

 

 

 

 

 

 

 

 

 

31-3/4"

 

 

 

 

 

 

 

2" (50mm)

 

 

 

 

30-1/2"

 

 

 

 

 

 

(805mm)

 

 

 

 

 

 

 

 

 

 

(775mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44" (1118mm)

2" (50mm)

 

2-3/16"(56mm)

 

 

 

55-7/16"

 

DIM EN SI ON S: H x W x D

 

 

 

 

 

 

(1407mm)

 

 

 

 

 

 

 

 

EXTERIOR:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52-11/16"x49-13 /16" x 45-3 /16"

(1337mm x 1 265mm x 1148mm)

 

 

 

 

 

 

EXTERIOR WITH RETRACTABLE DOOR:

 

 

 

 

 

 

 

 

 

52-11/16"x53-13 /16" x 45-3 /16"

(1337mm x 1 367mm x 1148mm)

 

 

 

 

 

 

INTERIOR:

 

 

 

 

 

 

 

 

 

 

 

33-7/8" x25-1/4" x 33-7 /8"

(860mm x 640mm x 8 60mm)

CL EAR AN CE RE QUIREMENTS

 

 

 

CONNECTED ENERGY LOAD :

105,000 Btu/ hr

 

 

 

GA S R EQ UI REM EN TS

 

LEFT

: 6" ( 152mm)

PLUS SERVICE ACCESS :

18" (457mm)

RECOM MENDED

 

 

HOOK-UP:

3/4" NPT

 

 

20" (508mm)

FR OM HEAT PR OD UC ING

EQUI PMEN T

MINIMUM CONNECTED PRESS URE:

5.5" W.C. (Natural Gas)

RIG HT : 4" ( 102mm)

TOP : 20" (5 08mm) FOR AIR MOVEMENT

MAXIMUM CONNECTED PRESSURE:

9" W.C. (Propane)

14" W.C.

BA CK : 4" ( 102mm)

BO TTOM : 5- 1/ 8" (1 30mm)

FOR LEGS

GAS TYPE MUST BE SPECIFIED ON ORDER.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAT ER Q UALI TY M IN IM UM S TA ND AR DS

TWO (2) COLD WATER INLETS - DRINKING QUALITY

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WATER R EQUI REMENTS

 

 

 

 

 

 

 

 

ONE (1) TREATED WATER INLET:

3/4" NPT*

 

 

WARRANTY. It is the responsibility of the purchaser to ensure

ONE (1) UNTREATED WATER INLET:

3/4" NPT*

2.8 to 6.2 bar

that incoming water supply is compliant with the specifications

LINE PRESSURE:

 

30 to 90 psi

listed through adequate treatment measures. Installation of the

 

 

WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP

CombiGuard™ Water Filtration System is recommended, but this

* Can manifold off of one 3/4" line.

 

 

 

system may not address all water quality issues present.

 

 

 

 

 

 

 

 

Contaminant

 

Inlet Water Requirements (untreated water)

IN STAL LAT ION R EQUIREMENTS

 

 

 

Free Chlorine

 

Less than 0.1 ppm (mg/L)

Ove n must b e in stalled l evel. Hood in stallati on. Wa ter supply

Hardness

 

Less than 3 gpg (52 ppm)

Chloride

 

Less than 30 ppm (mg/L)

shut-off v alve and backflo w p revent er. Alt ernate bu rner o rific e

pH

 

7.0 to 8.5

 

is req uired f or in stallation sit es at elevat ions of 3,00 0 feet (91 4m)

Alkalinity

 

Less than 50 ppm (mg/L)

Silica

 

Less than 12 ppm (mg/L)

abo ve sea lev el.

 

 

 

 

 

Total Dissolved

 

Less than 60 ppm

 

 

 

 

 

 

 

 

Solids (tds)

 

ELEC TR IC AL

 

 

 

 

 

 

 

 

 

 

VOLTAGE

PHASE

CYCLE/HZ

AWG

 

 

AMPS

kW

110 - 120

1

50/60

 

2 Wire plus ground, AWG 12

 

7.8

.936

 

 

 

OT HER VOLTAG ES AVAILABL E: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz

 

WEIGHT

 

CAPA CIT Y

 

 

 

 

NET

 

573 lb EST .

(260 kg) EST.

 

FULL-SIZEPANS:

20" x 12" x 2-1/2"

Twenty (20)

 

 

 

GN 1/1:

530 x 325 x 65mm

Twenty (20)

SHI P

 

875 lb EST .

(397 kg) EST.

 

 

GN 2/1:

650 x 530 x 65mm

Ten (10)

 

FULL-SIZESHEET PANS:*

18" x 26" x 1"

 

Ten (10)

CRATE

 

59" X

55" X 48"

EST .

 

ON WIRE SHELVES ONLY

240 l b ( 109 k g) MAXI MUM

 

DIME NSI ONS: (1499 x 1397 x 1219mm )

 

 

VO LUME MAXI MUM: 150

QUARTS (190 LITE RS)

 

 

 

 

*AD DIT IONAL

WIR E SHE LVES RE QUIRE D FOR MAXIM UM CAPAC IT Y

 

 

 

 

 

GAS

C OMB ITH ERM INS TA LLA TI O N

M AN UAL #MN-28676

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PG. 7

12•18E S G SPECIFICATIONS

 

 

 

 

®

 

 

 

 

 

 

 

 

 

 

COMBITHERM

 

 

 

(151mm)

4-3/8"(110mm)

20-5/16"

 

 

 

 

45-3/16"

 

 

 

 

 

 

 

42-9/16"

 

 

 

 

 

 

 

 

 

 

(1148mm)

 

 

 

6"

3-9/16"

(515mm)

49-13/16"(1265mm)

 

 

 

(1080mm)

 

 

 

Water Drain

 

 

 

 

 

 

 

 

 

 

 

 

12-13/16"22-11/16"

 

 

 

 

(89mm)

(Side Back)

47-7/8"(1215mm)

 

 

 

(678mm)

3/8"-19(491mm)3/8"-17

(441mm)

 

 

(325mm)

(575mm)

3/4"-26

Electrical Connection (Bottom)

(1875mm)13/16"

(184mm)5/16"-7

(1111mm)13/16"-43(1296mm)1/16"-51

(114mm)1/2"-4

 

 

 

 

 

Steam Vent

 

 

 

 

 

 

(Top)

 

 

 

 

 

 

 

 

 

 

Untreated Water

 

 

 

 

 

 

 

 

 

 

Intake (Bottom)

 

 

 

 

 

 

 

Gas Connection

Treated Water

 

 

 

 

Water Drain

 

Intake (Bottom)

 

 

 

 

(Bottom)

 

 

(Bottom)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-5/8"(116mm)

-

 

 

 

 

 

 

 

 

 

73

 

 

 

 

 

 

 

 

 

 

31-3/4"

 

 

 

 

 

 

 

 

2" (50mm)

 

 

 

 

25-5/8"

 

 

 

 

 

(805mm)

 

 

 

(650mm)

 

 

 

 

 

 

33-1/8"

7-3/16"

 

 

8-1/2"(216mm)

 

 

 

 

 

 

(840mm)

(181mm)

 

 

 

 

 

 

 

55-7/16"

 

DIME NSI ONS: H x W x D

 

 

 

 

 

 

 

(1407mm)

 

 

 

 

 

 

 

 

 

 

EXTERIOR:

 

 

 

 

 

 

 

 

 

 

51-1/16"x49-13/16" x45-3/16"

(1 296mm x 1265mm x 1148mm)

 

 

 

 

 

 

EXTERIOR WITH RETRACTABLE DOOR:

 

 

 

 

 

 

 

 

51-1/16"x53-13/16" x45-3/16"

(1 296mm x 1367mm x 1148mm)

 

 

 

 

 

 

INTERIOR:

 

 

 

 

 

 

 

 

 

 

33-7/8" x25-1/4" x 33-7 /8"

(860mm x 640mm x 86 0mm)

CLEARA NCE REQUI REM ENTS

 

 

 

 

CONNECTED ENERGY LOAD: 105,000 Btu /hr

 

 

 

 

GAS RE QU IR EM EN TS

 

LEF T: 6" (152mm)

PLUS SERVICE ACCESS : 18" (457mm)

RECOMMENDED

 

HOOK-UP:

3/4" NPT

 

20" (508mm)

FR OM

HE AT PRO DUCING

EQUIP MEN T

MINIMUM CONNECTED PRESSURE:

5.5" W.C. (Natural Ga s)

RIGHT : 4" (102mm)

 

TOP : 20" (5 08mm) FOR AIR MOVEMENT

MAXIMUM CONNECTED PRESSURE :

9" W.C. (Propane)

 

14" W.C.

BAC K: 4" (102mm)

BOTT OM :5-1/8"

(1 30 mm ) FOR LEGS

GAS TYPE MUST BE SPECIFIED ON ORDER.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WAT ER Q UALI TY M IN IM UM S TA ND AR DS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WATER REQUIREMENTS

 

 

 

 

 

 

 

 

 

 

ONE (1) TREATED WATER INLET:

 

3/4" NPT*

 

 

WARRANTY. It is the responsibility of the purchaser to ensure

ONE (1)

UNTREATED WATER INLET:

3/4" NPT*

2.8 to 6.2 bar

that incoming water supply is compliant with the specifications

LINE PRESSURE:

 

 

30 to 90 psi

listed through adequate treatment measures. Installation of the

 

WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP

CombiGuard™ Water Filtration System is recommended, but this

* Can manifold off of one 3/4" line.

 

 

 

 

 

system may not address all water quality issues present.

 

 

 

 

 

 

 

 

 

 

Contaminant

Inlet Water Requirements (untreated water)

INS TALL AT ION REQUIREMENTS

 

 

 

 

Free Chlorine

Less than 0.1 ppm (mg/L)

 

 

 

 

 

 

 

 

 

 

Hardness

Less than 3 gpg (52 ppm)

Oven must b e installe d l evel. Hood ins tal lati on. Water su pply

Chloride

Less than 30 ppm (mg/L)

shut-off valv e a nd back-flowpr event er. Alt ern ate bu rner or ifice

pH

7.0 to 8.5

 

is required for install atio n s ites at elevati ons of 3,000 fe et (91 4m)

Alkalinity

Less than 50 ppm (mg/L)

Silica

Less than 12 ppm (mg/L)

abo ve s ea level.

 

 

 

 

 

 

 

 

Total Dissolved

Less than 60 ppm

 

 

 

 

 

 

 

 

 

 

Solids (tds)

ELEC TRICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

PHASE

 

 

CYCLE/HZ

AWG

 

AMPS

kW

110 - 120

1

 

 

 

50/60

 

2 Wire plus ground, AWG 12

7.8

.936

 

 

 

OT HER VOLTAG ES AVAILA BLE : Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

WEI GHT

 

 

 

 

 

CAPA CITY

 

 

 

NET

666 lb EST .

(302 kg ) EST .

 

 

FULL-SIZEPANS:

20" x 12" x 2-1/2"

Twenty-four(24)

 

 

 

GN 1/1:

530 x 325 x 65mm

Twenty-four(24)

SHIP

865 lb EST .

(392 kg ) EST .

 

 

 

GN 2/1:

650 x 530 x 65mm

Twelve (12)

 

FULL-SIZESHEET PANS:*

18" x 26" x 1"

 

Twelve (12)

CRATE

56" X

55" X

50"

EST .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON WIRE SHELVES ONLY

288 l b ( 131 kg) MAXI MUM

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIO NS: (1422 x 1397 x 1270m m)

 

 

 

 

 

 

 

 

VOL UM E MAXI MUM : 180 QU ARTS(228 LIT ERS)

 

 

 

 

 

 

 

*AD DIT IONAL

WIR E SH ELVES RE QUIR ED FOR MAXIM UM CAPAC ITY

 

 

 

 

 

 

 

 

GAS

CO MBI TH ERM I NSTA LLATI ON

M A N UAL #MN-28676

 

 

PG. 8