combitouch® checklist

Use this list as a final check of oven installation conformance.

Damage directly attributed to improper set up, installation, or cleaning can invalidate warranty claims.

CLEARANCES:

Left:

6" (152mm) — Service access of 18" (457mm) recommended.

 

20" (508mm) from heat producing equipment.

Right:

4" (102mm)

Back:

4" (102mm) for plumbing

Top:

20" (508mm) for air movement

are all CLEARANCE

 

 

requirements met?

YES

NO

if no, explain:________________________

________________________________________

water supply and drains:

Verify hook-uptotwo (2) separatecold water supply lines with a3/4" (19mm) water connection supply line. Verify inlet water pressure is at a minimum of 30 PSI (2.8 bar). Maximum water pressure is not to exceed 90 PSI (6 bar). Verify drain diameter of1-1/2"(41mm) with a positive descending slope, and with a 2" (51mm) air gap which is free of obstructions before connection to the site drain. Verify 1/8" (3.2mm) pitch to 10' (305cm) of drain line.

important: Alto-Shaamhas listed Water Quality Requirements in the installation manual for this equipment. It is the responsibility of the end user to have the water connected to this appliance tested to ensure these standards are met before putting the oven into use. Failure to meet these standards will void the warranty if damage to the oven is found to be related to water quality.

are both water supply lines

properly connected?

YES

NO

if no, explain:___________________________

is a filter system installed

 

on this unit?

YES

NO

store has seen this

 

 

recommendation:

YES

NO

Signature of Store Representative:

___________________________________________

ELECTRICAL CONNECTIONS:

Verify electrical power requirements for oven. Verify voltage at terminal block.

Check all terminals for tightness.

VOLTAGE: ______________

PHASE: ______________

LINE VOLTAGE AT TERMINAL BLOCK (to ground):

 LINE 1: _________ LINE 2:_________ LINE 3: _________

LINE VOLTAGE (phase to phase): LINE 1 to 2: __________

LINE 2 to 3: __________

LINE 3 to 1: __________

ELECTRICAL SUPPLY LINE SIZE: ______________

 

breaker size: ______________

ALL ELECTRICAL TERMINALS TIGHT:

YES

NO

 

 

 

 

 

 

 

 

 

 

control board connections & operation:

ALL BOARD CONNECTIONS TIGHT:

YES

NO

 

 

 

 

 

With the Power on,press the Set-Up Key to access software version, and record.

YES

NO

 

 

 

ALL FUNCTIONS ARE DISPLAYED:

 

 

SOFTWARE VERSION:

ALL FUNCTIONS on control OPERATE:

YES

NO

 

 

unit OPERATEs in all modes:

YES

NO

 

 

RB_____________ DB_____________

if no, explain:_________________________________________

 

 

 

 

 

 

 

 

PHYSICAL CONDITION: *reference installation instructions for complete information

 

4

 

 

Bottom of oven has been checked for damage due to improper positioning on site....................................................

 

 

 

 

Verify all gaskets, hoses, and carts* are in place and function properly......................................................................

 

 

 

 

If oven includes a cart, verify proper installation of the rack guide on companion warmer or chiller*.....................

 

 

 

 

Verify the installation of drip pans*, racks, shelves, drain screen, spray hose* ..........................................................

 

 

 

 

Verify the oven is level and installed on a solid, water resistant floor.........................................................................

 

 

 

 

 

 

 

 

 

 

 

service agency:

 

start-update:

 

 

 

 

 

 

installation name:

 

 

 

 

model no.:

 

serial no.:

 

 

 

 

tech signature:

 

customer signature:

 

 

 

 

 

 

 

 

 

 

Combitouch® ES series • electric INSTALLATION MANUAL • 29..

i n s t a l l a t i o n

error codes

this section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel. if your alto-shaam® unit is not operating properly, check the following before calling your authorized alto-shaam service agent:

check that unit is receiving power. circuit breaker turned on?

do not attempt to repair or service the oven beyond this point. contact alto-shaamfor the nearest authorized service agent. repairs made by any other service agents without prior authorization byalto-shaamwill void the warranty on the unit.

when the oven malfunctions, an error code will appear in the display.

PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.

The icons that begin to flash represent operational modes that are still usable. when the oven fault is corrected, the combitherm will return to normal operation.

error

error call out in display

description of error

possible cause

 

code

 

 

 

 

 

 

 

 

 

e01

Low Water boiler

Low water level in boiler

— Water supply is shut off .

 

 

 

 

— Low water pressure .

 

 

 

 

— Generator drain cap missing or loose .

 

 

 

 

— Generator drain pump is not sealing .

 

 

 

 

— Generator drain pump elbow leaking .

 

 

 

 

— Faulty or scaled water level probe .

 

 

 

 

— Faulty or plugged dual solenoid valve assembly .

 

 

 

 

— Wiring or connection issue .

 

 

 

 

— No output to dual solenoid from relay board.

 

 

 

 

— Relay board, high voltage is not operating .

 

 

 

 

 

 

e02

Control Temperature high

Relay board surface

— Wiring or connection issue .

 

 

 

temperature too high

— Cooling fan on Relay board assembly is

 

 

 

 

not operating .

 

 

 

 

— Cooling Fan on display board is not operating .

 

 

 

 

— Main Cooling fan is not operating .

 

 

 

 

— Cooling Fan on motor drive is not operating .

 

 

 

 

— Unit is less than 20” from a heat producing source

 

 

 

 

on its left hand side .

 

 

 

 

 

 

e03

Fan Motor Error

Fan motor does not work

— Exhaust hood is not operating properly .

 

 

 

 

— Check LED fl ashes on the Motor Control .

 

 

 

 

see motor control error code list.

 

 

 

 

— Connection Issue on hall Effect sensor .

 

 

 

 

— Fan whel is not operating .

 

 

 

 

— hall sensor does not detect motor rotation .

 

 

 

 

 

 

e04

Fan Motor 2 Error

Lower fan motor on 20•20

— Exhaust hood is not operating properly .

 

 

 

does not work

— Check LED fl ashes on the Motor Control .

 

 

 

 

see motor control error code list.

 

 

 

 

— Connection Issue on hall Effect sensor .

 

 

 

 

— Fan wheel is not operating .

 

 

 

 

— hall sensor does not detect motor rotation .

 

 

 

 

 

 

e11

Convection Temperature

Excess oven temperature

Convection Mode & Combi Mode:

 

 

high

 

— Convection Oven contactor(s) stuck closed .

 

 

 

 

— N6 Oven Cavity Temperature probe defective.

 

 

 

 

— N6 Cavity Probe connection problem.

 

 

 

 

— Relay board, high voltage is not operating .

 

 

 

 

— Wiring or connection issue .

 

 

 

 

Combi Mode Only:

 

 

 

 

— Insuffi cient water supply into oven for

 

 

 

 

steam production .

 

 

 

 

 

 

 

 

 

continued on next page

Combitouch® ES series • electric INSTALLATION MANUAL • 30.

i n s t a l l a t i o n

error codes

error

error call out in display

description of error

 

possible cause

code

 

 

 

 

 

 

 

 

e13

boiler Temperature high

boiler temperature overheats

— Scale build up inside steam generator .

 

 

 

— Scale build up on water level probe .

 

 

 

— b4 Probe connection problem .

 

 

 

— b4 probe faulty .

 

 

 

 

e15

Condensor Temperature high

Excess condensor

— Untreated water supply line is shut off .

 

 

temperature

— Untreated water supply line is connected to

 

 

 

 

warm water .

 

 

 

— b3 probe connection problem .

 

 

 

— b3 probe is faulty .

 

 

 

— Single solenoid valve Y2 obstructed or faulty .

 

 

 

— Wiring or connection problem .

 

 

 

— Relay board, high voltage is not operating .

 

 

 

 

e20

hACCP Only - b11 Core

Single point core temperature

— Clean Probe Receptacle Pins with sand paper .

 

Temperature Probe Single

probe defect or disconnected.

— b11 Single Point Core Temperature probe with

 

Point Fault

 

 

quick connect, defective .

 

 

 

— b11 Single Point Core Temperature probe wires

 

Error E20 is not shown in display.

 

 

with quick connect, disconnected .

 

 

— b11 Single Point Core Temperature probe

 

Instead a probe sign with “?” is

 

 

 

 

receptacle, defective .

 

shown as popup window. In case

 

 

 

 

— b11 Single Point Core Temperature probe

 

the customer cooks in time mode

 

 

 

 

receptacle wires disconnected .

 

during fi rst step and during second

 

 

 

 

 

 

 

step switches to probe mode but has

 

 

 

 

no probe in place, the error E20 will

 

 

 

 

be shown in the error code list and

 

 

 

 

HACCP list.

 

 

 

 

 

 

 

e21

N6 Cavity Probe Fault

Cavity temperature probe

— N6 Oven Cavity Temperature probe defective.

 

 

defect or disconnected

— N6 Oven Cavity Temperature connection problem.

 

 

 

 

e22

B10 Core Temperature Probe

Multipoint core temperature

— B10 Multipoint Core Temperature probe defective.

 

Multipoint Fault

probe defect or disconnected

— B10 Multipoint Core Temperature probe connection

 

 

 

 

problem .

 

 

 

 

 

e23

b4 boiler Probe Fault

boiler temperature probe

b4 boiler temperature probe defective .

 

 

defect or disconnected

b4 probe wires connection problem .

 

 

 

 

e24

b5 bypass Probe Fault

bypass steam temperature

— b5 bypass steam temperature probe defective .

 

 

probe defect or disconnected

b5 bypass steam temperature connection problem .

 

 

 

 

e25

b3 Condensor Probe Fault

Condensor water

— b3 Condensor temperature probe defective .

 

 

temperature probe defect or

— b3 Condensor probe connection problem .

 

 

disconnected

 

 

 

 

 

 

 

e26

N8 Boiler Safety

Steam generator heating

N8 Boiler temperature probe defective.

 

Temperature Probe Fault

element protection probe

— N8 probe connection problem.

 

 

defect or disconnected

 

 

 

 

 

 

e27

boiler Element

Excess steam generator

— Scale build up inside steam generator .

 

Temperature high

safety probe

— Scale build up on water level probe .

 

 

 

— Water level probe connection failure .

 

 

 

— N8 boiler temperature probe defective.

 

 

 

— N8 probe connection problem.

 

 

 

— Steam element contactor(s) stuck closed .

 

 

 

— Wiring or connection problem .

 

 

 

 

 

continued on next page

Combitouch® ES series • electric INSTALLATION MANUAL • 31..

i n s t a l l a t i o n

error codes

error

error call out in display

description of error

possible cause

code

 

 

 

 

 

 

 

e34

Steam Generator Drain

Water level in steam

— Scale build up inside the steam generator

 

Pump Fault

generator does not drop

drain pump .

 

 

during cleaning program

— Scale build up inside the steam generator affecting

 

 

 

water level probes .

 

 

 

— Generator drain pump is faulty .

 

 

 

— Connection issue at drain pump .

 

 

 

— No output to pump from relay board.

 

 

 

 

e36

Steam Temperature high

Oven cavity temperature is

— Water supply is shut off .

 

 

too high when operating in

— Low water pressure .

 

 

a steam mode or cleaning

— Wiring or connection issue .

 

 

program

— Water injection pipe obstructed .

 

 

 

— Water fl ow control valve plugged or defective .

 

 

 

— Dual solenoid valve Y-1obstructed or defective .

 

 

 

— No output to solenoid valve form relay board.

 

 

 

 

e51

No Water In Boiler

Water inside steam generator

— Water supply is shut off .

 

 

does not reach low water

— Low water pressure .

 

 

level

— Generator drain cap missing or loose .

 

 

 

— Generator drain pump is not sealing .

 

 

 

— Generator drain pump elbow leaking .

 

 

 

— Faulty or scaled water level probe .

 

 

 

— Faulty or plugged dual solenoid valve assembly .

 

 

 

— Wiring or connection issue .

 

 

 

— No output to dual solenoid from relay board.

 

 

 

 

e53

Fan Motor high

Fan motor too hot

— Exhaust hood is not operating properly .

 

Temperature

 

— Check LED fl ashes on the Motor Control .

 

 

 

see motor control error code list.

 

 

 

— Connection Issue on hall Effect sensor .

 

 

 

— Fan wheel is not operating .

 

 

 

— hall sensor does not detect motor rotation .

 

 

 

 

e54

Fan Motor 2 high

20•20 lower fan motor too hot

— Exhaust hood is not operating properly .

 

Temperature

 

— Check LED fl ashes on the Motor Control .

 

 

 

see motor control error code list.

 

 

 

— Connection Issue on hall Effect sensor .

 

 

 

— Fan wheel is not operating .

 

 

 

— hall sensor does not detect motor rotation .

 

 

 

 

e55

Vent Not Open

browning valve does not open

— Alignment issue between motor cam and vent

 

 

 

motor safety switch (micro switch) .

 

 

 

— Fault vent valve (motor) .

 

 

 

— Fault vent valve safety switch (micro switch) .

 

 

 

— Wiring or connection problem .

 

 

 

 

continued on next page

Combitouch® ES series • electric INSTALLATION MANUAL • 32..

i n s t a l l a t i o n

error codes

error

error call out in display

description of error

possible cause

code

 

 

 

 

 

 

 

e57

No Rinse Water

During rinse no water

— Water supply is shut off .

 

 

fl ow is detected through

— Low water pressure .

 

 

solenoid valve

— Check wiring to all components mentioned below .

 

 

 

— Flow switch is dirty or defective .

 

 

 

— Dual water solenoid valve obstructed or faulty (Y3 .)

 

 

 

— Relay board, high voltage, defective .

 

 

 

 

e93

Communication Error,

Communication error

— Check ribbon cable connections mentioned below .

 

FROM Display board

between display board and

— Ribbon cable defective .

 

 

low voltage relay board

— Relay board, low voltage, connector defective .

 

 

 

— Display board connector defective .

 

 

 

 

e94

Communication Error,

Communication error

— Check ribbon cable connections mentioned below .

 

TO Display board

between display board and

— Ribbon cable defective .

 

 

low voltage relay board

— Relay board, low voltage, connector defective .

 

 

 

— Display board connector defective .

 

 

 

 

e98

Rb is in Cesius and Db is in

Confl ict of unit confi guration

— Relay board and Data board do not match, use

 

Fahrenheit

in the setup menu

setup menu to change format .

 

 

 

 

e99

Rb is in Fahrenheit and Db

Confl ict of unit confi guration

— Relay board and Data board do not match, use

 

is in Cesius

in the setup menu

setup menu to change format .

 

 

 

 

e100

Db is not equal to Rb

Software update may have

— Check ribbon cable connections .

 

version . Error generated

failed .

— Ribbon cable defective .

 

by Db .

 

— Relay board, low voltage, connector defective .

 

 

— Display board connector defective .

 

 

 

 

 

 

— Software may need to be updated again .

 

 

 

 

e101

Db is not equal to Rb

Software update may have

— Check ribbon cable connections .

 

version . Error generated

failed .

— Ribbon cable defective .

 

by Rb .

 

— Relay board, low voltage, connector defective .

 

 

— Display board connector defective .

 

 

 

 

 

 

— Software may need to be updated again .

 

 

 

 

Combitouch® ES series • electric INSTALLATION MANUAL • 33..

i n s t a l l a t i o n

combitouch motor control error codes

type of error

indication

release of error

 

 

 

Undervoltage

LED fl ashing sequence, with 1 fl ash per period.

Voltage of intermediate circuit is less than 250V

 

 

 

Overvoltage

LED fl ashing sequence, with 2 fl ashes per period.

Voltage of intermediate circuit exceeds 445V

 

 

 

Excess

LED fl ashing sequence, with 3 fl ashes per period.

Temperature sensor in the power unit is more than 93°C

Temperature

 

 

 

 

 

Overcurrent

LED fl ashing sequence, with 4 fl ashes per period.

Blocked motor, detected by current peak monitoring from

900 rpm rotating fi eld

 

 

 

Overcurrent

LED fl ashing sequence, with 5 fl ashes per period.

Intermediate circuit current exceeds 4.0A

 

 

 

Short-circuit

LED fl ashing sequence, with 6 fl ashes per period.

Release of interrupt at intermediate circuit current larger

 

 

than 53A

 

 

 

Power on

LED fl ashing sequence, with 7 fl ashes per period.

Effective mains voltage does not correspond to jumper

setting 115V/230V

 

 

 

Watchdog

LED fl ashing sequence, with 8 fl ashes per period.

Watchdog of the microcontroller released, program crash

 

 

 

CombiTouch® ES series • electric INSTALLATION MANUAL • 34..

i n s t a l l a t i o n

error codes

when the oven malfunctions, an error code will appear in the display.

PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.

The icons that begin to flash represent operational modes that are still usable. when the oven fault is corrected, the combitherm will return to normal operation.

error

 

model

 

mode

 

display shows

 

 

 

 

 

 

es

esg

steam

combination

convection

retherm

code

 

 

esi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e01

Low Water Boiler

Yes

No

No

No

To 365°F/185°C

No

 

 

 

 

 

 

 

 

e02

Control Temp High

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

e03

Fan Motor Error

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

e04

Fan Motor 2 Error

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

e11

Convection Temperature High

Yes

Yes

BOILER UNITS

No

No

No

 

 

 

 

ONLY

 

 

 

e13

Boiler Temperature High

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

e15

Condenser Temperature High

Yes

Yes

No

No

To 356°F/180°C

No

 

 

 

 

 

 

 

 

e20

B11 Core Temperature Probe Single Point

Yes

Yes

No

No

No

No

 

Fault - HACCP only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e21

N6 Cavity Probe Fault

Yes

Yes

BOILER UNITS

No

No

No

 

 

 

 

ONLY

 

 

 

e22

B10 Core Temp Probe Fault

Yes

Yes

BY TIME ONLY

BY TIME ONLY

BY TIME ONLY

BY TIME ONLY

 

 

 

 

 

 

 

 

e23

B4 Boiler Probe Fault

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

e24

B5 Bypass Probe Fault

Yes

Yes

No

No

Yes

No

 

 

 

 

 

 

 

 

e25

B3 Condenser Probe Fault

Yes

Yes

Yes

No

To 356°F/180°C

No

 

 

 

 

 

 

 

 

e26

N8 Boiler Safety Temperature Probe Fault

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

e27

Boiler Element Temperature High

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

e34

Steam Generator Drain Pump Fault

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

e36

Steam Temperature High

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

e51

No Water in Boiler

Yes

No

No

No

Yes

No

 

 

 

 

 

 

 

 

e53

Fan Motor High Temperature

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

e54

Fan Motor 2 High Temperature

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

e55

Vent Not Open

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

(NO BROWNING)

(NO BROWNING)

(NO BROWNING)

(NO BROWNING)

 

 

 

 

 

 

 

 

e57

No Rinse Water

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

e93

Communication Error FROM Display Board

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

e94

Communication Error TO Display Board

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

Combitouch® ES series • electric INSTALLATION MANUAL • 35..

i n s t a l l a t i o n

ventless hood option

The Ventless Hood option is factory installed directly on the top of the Alto-ShaamCombitherm oven. The hood is designed to vent clean air back into the kitchen, filtering vapors and grease. Ahigh-powerfan draws steam and fumes into the hood intake and out the top surface exhaust vent. Fumes and vapors are circulated through filters draining the condensation through a drain at the rear of the hood. An activated charcoal filter cleans the air before venting it out the top of the hood.

condensate drain

A ventless hood condensate drain line to the floor drain must be installed. The 3/4" NPT thread connection is found at the back of the hood. The drain line must always be a positive gradient away from the Combitherm.

filter door latch

Using a coin or screwdriver, turn to open; reverse procedure to close and latch.

Hood and oven will not operate unless this is closed properly.

Combitouch® ES series • electric INSTALLATION MANUAL • 36..

i n s t a l l a t i o n

ventless hood option

top exhaust vent

1

2

3

4

5

6

7

 

 

 

 

operation

1Turn the ventless hood power knob “ON”.

2Wait five seconds, then press the “combi reset” button.

3Turn the Combitherm oven power “ON”.

1 Ventless Hood Power Knob

2 Emergency Latch Release: This release is to be usedONLY if the timed latch mechanism is not working or in the event of a power outage. Repeated use of the emergency release may damage the switching mechanism.

3 Indicator Lights: If the indicator lights do not illuminate, the filters may be missing or not properly aligned. Check them for proper positioning. Ventless hood and oven will not operate unless the hood is closed properly.

4 Combi Reset Button: The reset has to be used if the Combitherm oven is turned on before the hood or if the hood was opened. It resets the pressure switch circuit and provides power to the Combi control circuit. This switch must also be used to reset hood controls after any problem with the filters, or the improper latching of the ventless hood door.

5 Charcoal Filter: The charcoal filter should be inspected for contaminant's on a regular basis. Replacement must be made at a minimum of three month intervals — more often if heavy contaminant's are visible or if the filter no longer controls odors.

To remove the filter, pull and slide out while holding the bottom housing. When replacing the filter, make certain the air flow arrow(s)

point toward the hood fan, and that the filter is replaced in the three-sidedmetal frame provided with the hood.

FI-24114(VHes-5);FI-24102(VHes-10)

6 Timed Latching Mechanism:In order to evacuate steam and grease-laden air from the oven interior, this mechanism prevents the operator from fully opening the oven door for 25 seconds to one minute. The mechanism automatically disengages at the end of a pre-set time allowing full door extension.

7 Grease Filter: Cleaning frequency should be based on oven usage with a maximum of two weeks between cleaning if the oven is used fornon-greaseladen products or steam applications only. Grease laden products require cleaning frequency of at least once a week.

Remove the grease filter by pulling it straight out of the housing. Place the filter in the dishwasher or wash separately by placing in hot, soapy water until all grease and particles have been removed. Rinse thoroughly. Allow the filter to air dry before reinstalling.

To replace the grease filter, the air flow arrow on the filter casing should be pointing toward the hood fan.

FI-24113(VHes-5);FI-23062(VHes-10)

Combitouch® ES series • electric INSTALLATION MANUAL • 37..

original equipment limited warranty

Alto-Shaam,Inc. warrants to the original purchaser that any original part that is found to be defective in material or workmanship will, atAlto-Shaam’soption, subject to provisions hereinafter stated, be replaced with a new or rebuilt part.

The labor warranty remains in effect one (1) year from installation or fifteen (15) months from the shipping date, whichever occurs first. Alto-Shaamwill bear normal labor charges performed by an authorizedAlto-Shaamservice agent during standard business hours, and excluding overtime, holiday rates or any additional fees.

The parts warranty remains in effect for one (1) year from installation or fifteen (15) months from the shipping date, whichever occurs first.

THIS WARRANTY DOES NOT APPLY TO:

1.Replacement of light bulbs, door gaskets, and/or the replacement of glass due to damage of any kind.

2.Equipment damage caused by accident, shipping, improper installation or alteration.

3.Steam generator or steam generating system damage as a result of inadequate routine maintenance and cleaning. Required maintenance and cleaning of steam generating equipment is the responsibility of the owner/operator.

4.Equipment used under conditions of abuse, misuse, carelessness or abnormal conditions including, but not limited to, equipment subjected to harsh or inappropriate chemicals including, but not limited to, compounds containing chlorine, chlorides or quaternary salts, or equipment with missing or altered serial numbers.

5.Equipment that uses water must meet Alto-Shaam’sminimum water quality standards as shown below. USE OF WATER NOT MEETINGALTO-SHAAM’SMINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY.

Water quality and required maintenance of steam generating equipment is the responsibility of the owner/operator. The installation and use of Alto-Shaam’sCombiGuard™ Water Filtration System is highly recommended.

ALTO-SHAAMCOMBITHERM WATER QUALITY MINIMUM STANDARDS

CONTAMINANT

INLET WATER REQUIREMENTS (UNTREATED WATER)

 

 

Free Chlorine

Less than 0.1 ppm (mg\L)

 

 

Hardness

Less than 3 gpg (52 ppm)

 

 

Chloride

Less than 30 ppm (mg\L)

 

 

pH

7.0 to 8.5

 

 

Alkalinity

Less than 50 ppm (mg\L)

 

 

Silica

Less than 12 ppm (mg\L)

 

 

Total Dissolved Solids (tds)

Less than 60 ppm

6.Damage caused by use of any cleaning agent other than Alto-Shaam’sCombitherm® Oven Cleaner including, but not limited to, damage due to chlorine, bleach, quaternary salts, scouring powders or other harmful chemicals. Use ofAlto-Shaam’sCombitherm Cleaner on Combitherm ovens is highly recommended.

7.Any losses or damage resulting from malfunction, including loss of product, food product, revenue, or other consequential or incidental damages of any kind.

8.Equipment modified in any manner from original model, substitution of parts other than factory authorized parts, removal of any parts including legs, or addition of any parts.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ALTO-SHAAMBE LIABLE FOR LOSS OF USE, LOSS OF REVENUE OR PROFIT, OR LOSS OF PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

No person except an officer of Alto-Shaam,Inc. is authorized to modify this warranty or to incur on behalf ofAlto-Shaamany other obligation or liability in connection withAlto-Shaamequipment.

Warranty effective November 1, 2011

Combitouch® ES series • electric INSTALLATION MANUAL • 38..