AT-CV5000Media Converter Chassis Installation Guide

LED Interface Card

The LED interface card, as shown in Figure 5, is preinstalled in theAT-CV5000chassis and is notfield-replaceable.The LED interface card features the following components:

One RS-232terminal port with aDB-9connector

One recessed RESET LINE/EXP button

Seven system status LEDs

RS-232Terminal Port

Recessed RESET LINE/EXP Button

PS-A

PS-B

 

LOTSSREAR.

OLESCON

FAN-A

F

 

AN-B

Status LEDs

251

RS-232Terminal

Port

Figure 5. LED Interface Card Components

You can use the RS-232terminal port on the LED interface card to establish a local connection to any module present in the expansion slot located in the rear of the chassis.

Note

This terminal port does not connect to any AT-CV5M01Management Card in the chassis. EachAT-CV5M01Management Card contains its ownRS-232terminal port, as shown inFigure 6 on page 24.

The RS-232terminal port on the LED interface card has aDB-9female connector and uses astraight-throughRS-232cable (not provided). The default settings for theRS-232terminal port are:

Baud rate: 115200 (range 2400 to 115200 bps)

21

Chapter 1: Overview

Interface Card

LEDs

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

These default settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulation program.

Table 1 lists the system status LEDs located on the LED interface card.

Table 1. Status LEDs on the LED Interface Card

LED

State

Description

 

 

 

 

 

 

RDY

Green

The module installed in the rear

(For future use)

 

expansion slot has passed

 

 

diagnostics and is ready.

 

 

 

 

OFF

The module installed in the rear

 

 

expansion slot has failed diagnostics

 

 

and is not ready, or is not installed.

 

 

 

MSTR

Green

This AT-CV5000chassis is acting as

(For future use)

 

a Stacking Master (via a module

 

 

installed in the rear expansion slot.)

 

 

 

 

OFF

This AT-CV5000chassis is not a

 

 

Stacking Master.

 

 

 

FLT

Green

The module installed in the rear

(For future use)

 

expansion slot has a fault condition, or

 

 

is not installed.

 

 

 

 

OFF

The module installed in the rear

 

 

expansion slot has not reported a fault

 

 

condition.

 

 

 

PS-A

Green

The power supply in slot A is

 

 

operating normally.

 

 

 

 

OFF

The power supply in slot A is OFF, not

 

 

present, or has failed.

 

 

 

PS-B

Green

The power supply in slot B is

 

 

operating normally.

 

 

 

 

OFF

The power supply in slot B is OFF, not

 

 

present, or has failed.

 

 

 

22

RESET LINE/

EXP Button

AT-CV5000Media Converter Chassis Installation Guide

Table 1. Status LEDs on the LED Interface Card (Continued)

LED

State

Description

 

 

 

 

 

 

FAN-A

Green

The fan module in fan tray slot A is

 

 

operating normally.

 

 

 

 

OFF

The fan module in fan tray slot A is

 

 

OFF, not present, or has failed.

 

 

 

FAN-B

Green

The fan module in fan tray slot B is

 

 

operating normally.

 

 

 

 

OFF

The fan module in fan tray slot B is

 

 

OFF, not present, or has failed.

 

 

 

You can use the recessed RESET LINE/EXP button to reset the line cards and/or the module currently present in the expansion slot in the rear of the chassis.

Note

This reset button does not allow you to reset any management cards in the chassis.

23