Allied Telesis Converteon AT-CV5000- User Manual
Size:
5.66 Mb
Download

Chapter 2: Installation

Powering On an AC Powered Chassis

This section describes how to power on an AC powered AT-CV5000chassis. If your chassis is DC powered, see“Powering On a DC Powered Chassis” on page 64.

Note

The AT-CV5000chassis is shipped without any power supplies installed. You must install at least one power supply in order to power on the chassis. For information about installing an AC power supply, refer to“Installing an AT-PWR14 AC Power Supply” on page 82.

Caution

The AT-CV5000Media Converter chassis can contain two power supplies of the same type (AC or DC) or a combination of the two versions with the same power ratings. Make sure not to mix power supplies with different power ratings in the same chassis.

For information on the power supply module, refer to the documentation that is shipped with the module.

Note

The AT-PWR14AC power supply is shipped with four power cords, one each for North America, the UK, Europe, and Australia. Locate the correct power cord for your location before beginning this procedure.

To power on an AC powered chassis, perform the following procedure:

1.Make sure that the ON/OFF power switch is in the OFF position, as shown in Figure 36.

A CVFAN-AT

 

A

100-240

VAC~

 

inrWARNINGTehpdisuutcusenbtitehfmeorirgieshksteohrvfaveiceleinmcgtoruircensitthh. oacnko, ndeispcoownneercint paulltp. Toower

 

POWER

 

FAULT

277

PWR A

 

 

B

 

 

AT-

PWR1

100-

240VAC~

B

POWER

 

4

 

 

 

 

FAULT

 

 

 

CV5FAN-AT

 

 

 

 

 

 

 

1131

 

PWR B

Figure 36. ON/OFF Power Switch in OFF Position

60

AT-CV5000Media Converter Chassis Installation Guide

2.Position the power cord retaining clip in the up position, as shown in Figure 37.

A CVFAN-AT

 

 

A

 

B

 

 

 

 

 

PWR14

 

 

100-

 

inrWARNINGTehpdisuutcuentithme rigishkt have m

POWER

 

 

240VAC

~

 

AT-

100-

240VAC~

B

 

 

s before seorvf eicleincgtoruircensitthh. oacnko, ndeispcoownneercint paulltp. Toower

FAULT

 

 

CV5FAN-AT

 

P

OWER

 

 

 

 

FAULT

 

 

 

 

 

 

 

 

 

1132

 

278

PWR A

PWR B

Figure 37. Power Cord Retaining Clip in the Up Position

3.Select the power plug that is correct for your region: North America, UK, Europe, or Australia.

4.Plug the power cord into the AC power connector on the rear of the chassis, as shown in Figure 38.

A CVFAN-AT

 

A

 

 

B

 

 

 

 

 

 

100-240

inrWARNINGTehpdisuutcusenbtitehfmeorirgieshksteohrvfaveiceleinmcgtoruircensitthh. oacnko, ndeispcoownneercint paulltp. Toower

POWER

AT-PWR14

100-240VAC~

B

 

VAC~

 

 

 

 

 

 

FAULT

 

 

-AT

 

 

 

 

 

 

FAULT

 

 

 

CV5FAN

 

POWER

 

 

 

 

 

279

 

 

1133

 

PWR A

PWR B

Figure 38. Connecting the AC Power Cord

5.Secure the cord by lowering the power cord retaining clip, as shown in Figure 39.

A CVFAN-AT

 

A

 

 

 

100-240

 

 

 

 

VAC~

WARNING

 

 

 

 

This unit

 

 

 

 

reduce themight have

more than

 

 

inputs beforerisk of

 

one po

 

se

electric

 

 

rvicing unit.shock,

wer

 

 

 

 

disconnectinput. To

 

 

 

 

all power

 

POWER

 

 

 

 

F

 

 

 

 

AULT

 

 

 

POWER FAULT

 

B

AT-PW

100-240VAC~

 

R14

B AT-CV5FAN

280 1134

PWR A PWR B

Figure 39. Securing the Power Cord with the Retaining Clip

61

Chapter 2: Installation

6.Turn the ON/OFF power switch of the installed power supply module to the ON position, as shown in Figure 40.

100-

 

240

VAC~

A

WARNINGThis unit reduce themight h inputs bef risk o ore se

Power Switches

to ON

Position

 

 

 

 

 

B

NG

 

 

 

 

might

have

 

e

 

 

m

 

risk of

 

fore

 

 

elec

 

 

servicin

~

POWER F

PWR A

1135 PWR B

Figure 40. ON/OFF Power Switch in ON Position

7.Plug the other end of the power adapter to a power outlet.

If you purchased a second AT-PWR14AC power module, repeat this procedure to install the additional module.

Refer to “Technical Specifications” on page 101 for power requirements.

Caution

To further protect the AT-CV5000chassis, connect each AC power cord to power sources that are operating on different power circuits. This arrangement protects the chassis from a power loss if one of the power circuits fails.

Warning

This unit might have more than one power source. To reduce the risk of electric shock, disconnect all power cords before servicing the unit. E30

Warning

Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. E4

8.Check that the POWER LED on the AT-PWR14AC power module is green. If the POWER LED is OFF or the FAULT LED is ON, refer to“Troubleshooting” on page 95 for instructions.

The chassis is now ready for network operations.

No further installation steps are required if you do not need to change the

62

AT-CV5000Media Converter Chassis Installation Guide

default parameter settings of the chassis, which are listed in the AT-S70 Management Software User’s Guide. However, if you want to manage the chassis or review the settings, refer to“Starting a Local Management Session” on page 67 and“Starting a Remote Management Session” on page 70.

63