Alliance Laundry Systems Dishwasher User Manual

Size:
1.47 Mb
Download

Installation Instructions

for Stacked Washers and Dryers

Inside......................................

 

Dimensions........................................................................

3

Before You Start................................................................

4

Installation.........................................................................

5

Installer Checklist ............................................

Back Cover

Date Purchased _____________________________

Model Number _____________________________

Serial Number ______________________________

Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com.

Keep these instructions for future reference.

(If this machine changes ownership, this manual must accompany machine.)

 

 

 

www.comlaundry.com

Part No. 802715R3

 

 

 

 

 

 

May 2011

WARNING

FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.

W033

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building or area of all occupants.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

W052

IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the unit user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the unit for customer use.

WARNING

Installation of unit must be performed by a qualified installer.

Install clothes dryer according to manufacturer’s instructions and local codes.

DO NOT install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Refer to section on connecting exhaust system. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.

W729R1

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

W053

The following information applies to the state of Massachusetts, USA.

This appliance can only be installed by a Massachusetts licensed plumber or gas fitter.

This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.

A “T-Handle”type gasshut-offvalve must be installed in the gas supply line to this appliance.

This appliance must not be installed in a bedroom or bathroom.

©Copyright 2011, Alliance Laundry Systems LLC

All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.

2

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

802715

Dimensions

 

 

 

 

 

 

 

 

 

 

*63 in. (160 cm)

 

 

 

 

in.(137.2 cm)

 

 

 

*54

 

 

 

 

 

 

 

 

 

 

23.5 in.

 

 

 

 

 

(59.7 cm)

 

 

 

 

 

 

8.0 in.

 

 

 

 

 

(20.3 cm)

 

 

15.4 in.

 

 

 

 

 

 

 

 

(39.1 cm)

5.25 in.

 

 

 

 

 

(13.3 cm)

 

 

 

 

 

24 in.

cm)

 

 

 

 

(61 cm)

 

 

 

 

 

 

 

 

*37.44in. (95.1 cm)

(33.3 cm)

*75.25in. (191.1

*44.1in. (112 cm)

(75.1in.*29.6cm)

*

*13.1 in.

 

 

 

31.1cm)(79in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*14.6 in.

 

 

 

 

 

 

28 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26.875 in.

 

 

 

 

 

 

 

 

 

 

(71.1 cm)

 

 

 

2.0 in.

 

(68.3 cm)

 

 

 

 

(37.08 cm)

1.5 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5.1 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3.81 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC DRYERS

SWD897N

* With leveling legs turned into base.

NOTE: Exhaust openings are 4 inch (10.2 cm) metal ducting.

 

 

 

 

 

 

 

 

*63 in. (160 cm)

 

 

(137.2 cm)

 

 

*54 in.

 

 

 

 

 

 

 

 

 

 

23.5 in.

(59.7 cm)

5.25 in.

(13.3 cm)

24 in.

(61 cm)

*13.1 in.

(33.3 cm)

1.5 in.

(3.81 cm)

8.0 in.

 

(20.3 cm)

15.4 in.

 

(39.1 cm)

 

 

1

 

cm)

 

2.3 in.

 

*75.25 in. (191.1

*44.1 in. (112 cm)

(6 cm)

 

*29.6 in. (75.1 cm) *31.1 in. (79 cm) *42.4 in. (107.7 cm)

*37.44 in. (95.1 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*14.6 in.

28 in.

 

 

 

 

 

 

 

 

 

26.875 in.

 

 

 

 

(71.1 cm)

 

 

 

 

 

2.0 in.

 

 

 

(68.3 cm)

 

 

 

 

 

 

(37.08 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5.1 cm)

 

 

 

 

 

 

 

 

 

 

 

 

GAS DRYERS

SWD898N

*With leveling legs turned into base.

NOTE: Exhaust openings are 4 inch (10.2 cm) metal ducting. 1 3/8 in. NPT Gas Connection

802715

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

3

Before You Start

Supplies

For most installations, the basic supplies you will need are:

1

2

3

 

5

 

 

6

 

4

 

7

 

1

 

9/

 

 

6

 

 

"

 

8

9

DRY2023N

1Safety Glasses

2Wood Block

3Power Cord (Electric Models)

4Wrench

5Screwdriver

6Level

75/16 Inch Socket Wrench

8Duct Tape

9Teflon Tape (Gas Models)

Figure 1

WARNING

Any disassembly requiring the use of tools must be performed by a suitably qualified service person.

W299

NOTE: If the unit is delivered on a cold day (below freezing), or is stored in an unheated room or area during the cold months, do not attempt to operate it until the unit has had a chance to warm up.

NOTE: Some moisture in the wash drum is normal. Water is used during testing at the manufacturer.

4

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

802715

Installation

Step 1: Position Unit Near Installation Area

Move unit as close to the desired area of installation as possible.

NOTE: For best performance and to minimize vibration or movement, install washer on a solid, sturdy and level floor. Some floors may need to be reinforced, especially on a second floor or over a basement. Do not install the washer on carpeting, soft tile, a platform or other weakly supported structures.

WARNING

Washer and dryer are not designed to be operated as separated, side-by-sideunits.

W187

Step 2: Position and Level the Unit

Position unit so it has sufficient clearance for installation and servicing. Refer to Figure 2.

C

D

E

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

B

SWD795N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dryer and Exhaust Duct Clearances

 

 

 

 

 

 

 

 

Area

 

 

 

 

 

 

Description

Minimum Clearance

 

 

 

 

 

A

 

 

Left Dryer Side

0 in. (0 cm)

 

 

 

 

 

B

 

 

Right Dryer Side

1 in. (2.54 cm)

 

 

 

 

 

C

 

 

Dryer Top

6 in. (15.24 cm)

 

 

 

 

 

D

 

 

Dryer Rear

4 in. (10.2 cm)

 

 

 

 

 

E

 

 

Exhaust Duct Clearance to Combustible Materials

2 in. (5.1 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Shaded areas indicate adjacent structure.

SWD795N

Figure 2

802715

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5

NOTE: Use of the dispenser drawer or unit doors as a handle in the transportation of the unit may cause damage to the dispenser or doors.

Place unit in position on a solid, sturdy and level floor. Installing the unit on any type of carpeting, soft tile, a platform or other weakly supported structures is not recommended.

Place a level on the cabinet top and check if the unit is level from side to side and front to back.

NOTE: Level must rest on raised portion of top panel. Refer to Figure 3.

1

5

4

3

2

SWD833N

1Level

2Rubber Foot

3Leveling Leg

4Locknut

5Unit Base

Figure 3

If unit is not level, tilt unit to access the front and rear leveling legs. For easier access to leveling legs, prop up unit with a wooden block. Refer to Figure 4.

Loosen the locknuts and adjust legs by screwing into or out of unit base.

1

SWD832N

1 Wood Block

Figure 4

Make sure that the unit does not rock. When unit is level and does not rock, tighten locknuts securely against bottom of unit base. If these locknuts are not tight, unit will move out of position during operation.

Leveling legs can be adjusted from inside the unit with a 7/8 inch deep well socket. All four legs must rest firmly on the floor so the weight of the unit is evenly distributed. The unit must not rock and must be level from side-to-sideandfront-to-back.

NOTE: Do not slide unit across floor once the leveling legs have been extended. Legs and base could become damaged.

Place rubber feet (supplied in accessories bag) on all four leveling legs. Refer to Figure 3.

Verify that unit does not rock.

6

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

802715

Step 3: Connect Fill Hoses

WARNING

Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period and before using the washer, turn on all hot water faucets and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. The gas is flammable. Do not smoke or use an open flame during this time.

W029

Water Supply

Water supply faucets must fit standard 3/4 inch (19.1 mm) female garden hose couplings. DO NOT USE SLIP-ONORCLAMP-ONCONNECTIONS.

Water supply faucets should be readily accessible to permit turning them off when washer is not being used.

Recommended cold water temperature is 60o to 80o Fahrenheit (16o to 27o Celsius). Recommended maximum hot water temperature is 125° Fahrenheit

(51o Celsius). Warm water is a mixture of hot and cold water. Warm water temperature is dependent upon water temperature and pressure of both the hot and cold water supply lines.

WARNING

To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit (51° Celsius) and hot surfaces.

W748

Water pressure must be a minimum of 20 to a maximum of 120 pounds per square inch (138 to 827 kPa) static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per square inch (138 kPa) will cause an extended fill time in the washer and may not properly flush out the detergent dispenser.

Turn on the water faucets and flush the lines for approximately two minutes to remove any foreign material that could clog the screens in the water mixing valve.

NOTE: When installing in newly constructed or renovated buildings, it is very important to flush the lines since build-upmay have occurred during construction.

Connecting Hoses

Remove the two plain rubber washers and two filter screens from the accessories bag. Install them into each end of the fill hoses as shown in Figure 5. The screen must be facing outward.

Screw hose couplings with the filter screens onto the water faucets until they are finger-tight.Then, using a pliers, screw approximately 1/4 turn.

Screw hose couplings from other end of hoses onto the water mixing valve until they are finger-tight.Then, using a pliers, screw approximately 1/4 turn. Refer to

Figure 6.

IMPORTANT: Do not cross thread or overtighten couplings. This will cause them to leak.

Turn water on and check for leaks. If leaks are found, turn off the water, unscrew hoses and reinstall them until there are no leaks.

IMPORTANT: Turn off water supply whenever there will be an extended period of non-use.

1

COLD

HOT

2 3

5

4

TLW1976N

1Water Faucet

2Fill Hose

3Plain Rubber Washer

4Hose Coupling

5Filter Screens

Figure 5

802715

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

7

IMPORTANT: Hoses and other natural rubber parts deteriorate after extended use. Hoses may develop cracks, blisters or material wear from the temperature and constant high pressure they are subject to.

All hoses should be checked on a monthly basis for any visible signs of deterioration. Any hose showing the signs of deterioration listed above should be replaced immediately. All hoses should be replaced every five years.

1

 

2

 

 

 

 

WATER

 

 

MIXING VALVE

 

4

3

 

 

 

 

SWD596N

 

 

SWD596N

1

 

Water Faucets

2

 

Cold Water Connection

3

 

Hot Water Connection

4

 

Water Fill Hoses

Figure 6

IMPORTANT: Turn off water supply faucets after check-outand demonstration. Owner should turn off water supply whenever there will be an extended period ofnon-use.

NOTE: Longer fill hoses are available (as optional equipment at extra cost) if the hoses supplied with the washer are not long enough for the installation. Order hoses as follows:

No. 20617 Fill Hose (8 feet) (2.44 m) No. 20618 Fill Hose (10 feet) (3.05 m)

Risers

Risers (or air cushions) may have to be installed if the pipes knock or pound when flow of water stops. The risers are more efficient when installed as close as possible to the water supply faucets (refer to Figure 7).

2

1

W005I

W005I

1Water Supply Faucets

2Risers (Air Cushions)

Figure 7

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

802715

Step 4: Connect Drain Hose to Drain Receptacle

Remove the drain hose from its shipping position on the rear of the washer by unhooking the hose from the retainer clamp and by removing the shipping tape.

Install the drain hose into the drain receptacle (standpipe, wall or laundry tub) following the instructions below.

IMPORTANT: Drain receptacle must be capable of handling a minimum of 1-1/4inch (32 cm) outside diameter drain hose.

Standpipe Installation:

Place the drain hose into the standpipe.

Remove the beaded strap from accessories bag and place around standpipe and drain hose and tighten strap to hold hose to standpipe. Refer to Figure 8. This will prevent the drain hose from dislodging from drain receptacle during use.

1

 

 

24 in. to 36 in.

 

 

(61 to 91.44 cm)

 

Recommended

 

 

Height

 

 

 

2

 

 

3

SWD598N

 

 

SWD598N

1

Drain Hose

 

2

Beaded Tie-DownStrap

 

3

Standpipe 2 in. (5.08 cm) or 1-1/2in. (4 cm)

Figure 8

Wall Installation:

For installations of this type, the drain hose MUST be secured to one of the fill hoses using the beaded strap from accessories bag. Refer to Figure 9.

NOTE: End of drain hose must not be below 24 in. (61 cm).

1 2

3

H023I

1Drain Hose

2Beaded Strap (tape if necessary)

3Fill Hoses

Figure 9

Laundry Tub Installation:

For this type of installation, the drain hose MUST be secured to the stationary tub to prevent hose from dislodging during use. Refer to Figure 10. Use the beaded strap (supplied in accessories bag) to secure hose.

1

2

SWD600N

SWD600N

1Drain Hose

2Tie-DownStrap (tape if necessary)

Figure 10

802715

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9

Step 5: (Gas Dryer Only) Connect Gas

Supply Pipe

WARNING

To reduce the risk of gas leaks, fire or explosion:

The dryer must be connected to the type of gas as shown on nameplate located in the door recess.

Use a new flexible stainless steel connector.

Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads.

Purge air and sediment from gas supply line before connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent gas valve contamination.

Do not use an open flame to check for gas leaks. Use a non-corrosiveleak detection fluid.

Any disassembly requiring the use of tools must be performed by a suitably qualified service person.

W316

1.Make certain your dryer is equipped for use with the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8 inch NPT gas connection.

NOTE: The gas service to a gas dryer must conform with the local codes and ordinances, or in the absence of local codes and ordinances, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CSA-B149.1Natural Gas and Propane Installation Code.

Natural Gas, 1000 Btu/ft3 (37.3 MJ/m3) service must be supplied at minimum 5.0 inch water column pressure to maximum 10.5 inch water column pressure.

For proper operation at altitudes above 3000 feet (915 m) the natural gas valve spud orifice size must be reduced to ensure complete combustion. Refer to

Table 1.

Natural Gas Altitude Adjustments

Altitude

 

Orifice Size

 

Part No.

 

 

 

 

 

 

 

feet

m

No.

 

inches

 

mm

 

 

 

 

 

 

 

 

 

 

 

3000

915

43

 

0.0890

 

2.26

503778

 

 

 

 

 

 

 

 

6000

1830

44

 

0.0860

 

2.18

58719

 

 

 

 

 

 

 

 

8000

2440

45

 

0.0820

 

2.08

503779

 

 

 

 

 

 

 

 

9000

2740

46

 

0.0810

 

2.06

503780

 

 

 

 

 

 

 

 

10,000

3050

47

 

0.0785

 

1.99

503781

 

 

 

 

 

 

 

 

Table 1

2.Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap.

3.Connect to gas supply pipe.

NOTE: When connecting to a gas line, an equipment shut-offvalve must be installed within 6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer toFigure 11.

1

5

2

3

4

D434I

1New stainless steel flexible connector - (Use design CSA certified connector) Use only if allowed by local codes

21/8 in. NPT Pipe Plug

3Equipment Shut-OffValve

4Black Iron Pipe

Shorter than 20 ft. (6.1 m) - Use 3/8 in. (9.5 mm) pipe Longer than 20 ft. (6.1 m) - Use 1/2 in. (12.7 mm) pipe

53/8 in. NPT Gas Connection

Figure 11

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT